Laserfiche WebLink
''ll I 'I 111 111 1 11 II 1111 11 1 1 1 1 1 1'111' 11- IT 11KIM11'll 11111I II"' 1' 1 1 1 1 i II -' - . - - - - - <br />1 <br />12 <br />5 <br />1" x 4" SMOOTH I=I <br />TEXTURED U <br />TRIM / BAND <br />12 <br />�5 <br />-------- T.O.P. <br />HDR HGT. <br />RIGHT ELEVATION - B1_ <br />1. <br />ti <br />2nd FIN. <br />FLR. <br />T.O.M. <br />HDR HGT. <br />00 <br />cC? <br />o <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES, <br />Exterior Covering <br />R703.6 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.6.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.6.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.6.3 Water-Resisitive Barriers. <br />Water-resisitive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paperbacked <br />stucco lath) over an approved synthetic house wrap. <br />R703.8 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior windowldoor openings. <br />• Intersection of chimneys or other masonry contructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 5th Edition <br />(2014) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated. Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />-CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN - <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA/ UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA/ SQ. FT. <br />• O'HAGIN WEATHERMASTER (Shingle Roof) - 72 SO. IN. OF NET FREE AREA/ FT. <br />" (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 72 = Amount of O'Hagin Vents Needed <br />• LOMANCO DECK -AIR (Shingle Roof) - 9 SQ. IN. OF NET FREE AREA / FT. <br />Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) 19 = Linear Ft. of Deck -Air Needed) <br />• O'HAGIN (Tile Roof) - 86.25 SQ. IN. OF NET FREE AREA/ VENT <br />—Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed)186.25 = Amount of O'Hagin Vents Needed <br />M <br />0 <br />Z <br />Q <br />J <br />d <br />to (D <br />Q) <br />(/) <br />(DM <br />4- J w <br />r) <br />U — <br />uU <br />0 � <br />0 <br />-(D- <br />"- <br />VM � <br />r0 <br />m 04 <br />04 <br />U <br />L.L.4 <br />E <br />�M M <br />C t6 M <br />T a N <br />—8 <br />Ooo <br />a: <br />cLL00 <br />Ly Y <br />V% Q C).4 <br />0 <br />Q rn <br />`n � <br />M< o <br />A <br />Is®. <br />N C B D C <br />WV <br />�:-.41 OG <br />MLWAD, <br />11.1 <br />cj <br />g <br />ilfi to <br />LL <br />LL <br />h <br />f0 t n's) <br />-c <br />LL <br />W <br />��N v _ 0 e , ` <br />a. 4 <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />O <br />O <br />Z N <br />0 au r, <br />O <br />w M O <br />M <br />'Q Lf) t17 <br />V r\ <br />Q IL <br />Q r-� <br />try V <br />o <br />CL <br />E '­ <br />Z <br />C:) � <br />WW <br />J� <br />OZ <br />E ,CC <br />G <br />cp <br />zaa <br />z <br /><a <br />v^ J <br />' <br />rF <br />w¢� � <br />�z°0 <br />Z <br />p <br />Uz< z <br />�— <br />_ <br />0 w Z <br />J LLJJ <br />'/ <br />KaO2 n � <br />o <br />o~BOO <br />W <br />N <br />TT <br />—17 <br />J <br />OV) <br />} o <br />W <br />1 z <br />x <br />cZ <br />G <br />. Q <br />I- <br />� <br />V <br />LAr) <br />0 <br />U <br />= <br />I` _ <br />Q <br />a <br />9 W <br />o <br />F 4J4M <br />0 <br />r- <br />. <br />m <br />U c¢R. <br />1 _J <br />zaai Q¢ <br />w�Z¢ <br />tj cQ <br />Q <br />00�� <br />z <br />U-M�o <br />z <br />W <br />LP) <br />di <br />`� <br />w <br />: Q <br />_! <br />r-i <br />UJ <br />Q <br />z <br />(A0 z o <br />2wv <br />he <br />w ~ ~ Q w z <br />a� <br />V <br />z <br />&Y,;p <br />o <br />g <br />= <br />J z <br />az <br />r, <br />,-I <br />a <br />U0 <br />SCALE : AS NOTED <br />DATE: 2/24/2014 <br />TECH: MJAMES <br />VERSION N0. <br />10 <br />SHEET NO. <br />3.1 <br />