My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3234 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3234 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 2:40:08 AM
Creation date
2/19/2025 8:59:44 AM
Metadata
Fields
Template:
Building Plans
Street #
3234
Location
Moulden Hollow Dr
Contractor
Lennar Homes
Building Plans - Permit #
19307
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217, <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />PqF <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />q)4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />Q EXHAUST FAN <br />;Q� EXHAUST FAN/LIGHT COMBINATION <br />® D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />O PUSHBUTTON SWITCH (OPTIONAL) <br />SD SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />©2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD, HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />D]M <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 08, 250.94 <br />200A <br />INDOOR PANEL <br />CENTER <br />10 #14 copper to lights 8 outlets <br />NEMA 1 <br />200 AMP <br />01 #12 copper to 20 amp ckts <br />00 #10-2 copper to WH <br />#10-3 copper to Dryer <br />METER <br />MAIN <br />O2/0 <br />or <br />4/0 SER Alu <br />200 amp <br />tr <br />150 amp <br />4 Bare Cu Ground <br />WITH CODE APPROVED <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2011 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />FC...._ ...... <br />SYSTEM <br />I I <br />L <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />r—� <br />I I <br />L _ J <br />® SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />C/> CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR UPPER ELECTRICAL PLAN <br />G J OPT. CEILING FAN <br />0�31 (1) PHONE LINE, (1) DATA PORT SCALE: %4'=1'-0" <br />(D LO <br />Z M <br />O <br />— O <br />Z � <br />z� <br />4 <br />O <br />+� Z <br />V) 0 <br />n <br />W U-) <br />(DI70 <br />LL, <br />— <br />O <br />o <br />co <br />V� <br />0 0 <br />U <br />W <br />a)M <br />c W co <br />H <br />— U <br />t9 'O M <br />O O NO <br />r-F00 <br />0 <br />Y <br />r 0 O <br />Qrn <br />rnQo <br />A 1 <br />B <br />NCBDC <br />, <br />c- <br />O <br />N <br />CC) N <br />.w o 4 m p <br />°Ci <br />O 000 <br />04 <br />�Z W 2-'-. � C p <br />J <br />ILL. Z <br />tL <br />ii Cl) LL N <br />W ° <br />N �� 0 <br />UL <br />d <br />W � Q O.� � <br />Z <br />Z v U rn = <br />0 <br />0 <br />00 <br />@ Boa <br />o^o <br />m m <br />QaQM <br />W <br />N U <br />Jo <br />< <br />U <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />A <br />O <br />O <br />Z cV <br />O n <br />��o <br />tom+ M O <br />M <br />Q U) fo U) <br />CL u7 •� d' <br />Q a L.L. Ln <br />ro <br />Z CL p�U fu� <br />Q � <br />E <br />� � <br />Z <br />WJ C:) <br />0z <br />�o <br />Lu <br />Za <br />f a <br />F- <br />z <br />Q <br />W z a- <br />rz�° <br />�.. <br />�2z� <br />MUM <br />Z <br />Q <br />n �y�g <br />OLuu <br />U <br />N <br />o <br />FuJ <br />oZ <br />zo <br />U <br />Zz <br />ryo, <br />Ln <br />w <br />J <br />.0 <br />N <br />LU <br />o <br />� <br />CC�Z <br />O <br />U <br />= <br />N <br />O <br />�Lu <br />O <br />o� <br />ao0 <br />TMR <br />z <br />U- <br />U a m p <br />(V� <br /><za�a <br />a <br />G <br />cpaQ <br />Q <br />Z <br />o <br />�o <br />LL <br />Z <br />W <br />�_q <br />Lr) <br />di=aao <br />a <br />�W� <br />J <br />ri <br />z U <br />Q <br />Z <br />oz <br />1,0 <br />Z <br />Z <br />� <br />ajj <br />0� <br />O <br />� <br />W <br />Jo <br />W <br />,--I <br />a <br />to <br />I II <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: M)AM ES <br />VERSION NO- 10 <br />0 <br />SHEET NO. <br />4.1 <br />