My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3253 Kresterbrooke Ln
Zephyrhills
>
Building Department
>
Building Plans
>
3253 Kresterbrooke Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 3:19:54 AM
Creation date
2/19/2025 9:00:04 AM
Metadata
Fields
Template:
Building Plans
Street #
3253
Location
Kresterbrooke Ln
Contractor
Lennar Homes
Building Plans - Permit #
20294
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
v <br />v <br />S <br />cp <br />C'V <br />O <br />co <br />m <br />x <br />ca <br />cV <br />N <br />00 <br />a� <br />E <br />s <br />00 <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />10 ✓«14 copper to lights &. outlets <br />NEMA 1 <br />200 AMP <br />10 #12 copper to 20 amp ckts <br />10 k10-2 copper to WH <br />01 #10-3 copper to Dryer <br />METER <br />n <br />2/0 or <br />4/0 SER Alu <br />200 amp <br />IT <br />150 amp <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. in new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.1. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />. <br />24 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />;Q+ <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />Pl3 <br />PUSH BUTTON SWITCH (OPTIONAL) <br />H9 <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />N <br />TELEVISION (OPTIONAL) <br />02 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />M <br />ELECTRIC METER <br />NMI <br />PANEL <br />_ _� <br />DISCONNECT SWITCH <br />® <br />SPEAKER (OPTIONAL) <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />< <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />WP DISC. <br />GFI H. <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />unnn mCo 00C 10 <br />RECEPT. <br />FOR ALARM <br />SYSTEM <br />VCMIr T IVIC I CM <br />LOCATION WITH <br />BUILDER <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: j4"=1'-0" <br />r ;,_ <br />co <br />O <br />O <br />C: <br />W cs3 <br />�w <br />® <br />�V — <br />0 ICI <br />F <br />o <br />CD <br />E <br />F= 8 <br />N <br />CO <br />t11 co <br />_ <br />,-@a <br />O o N <br />0 <br />(�wau <br />o <br />00 <br />0 Co <br />M <br />n.o <br />Lo �v <br />M Q o <br />BIDN <br />C C YV <br />_ N N <br />O M CD <br />to 00U) <br />Z W M N 02 z w z <br />�. �LLo � [Ll w <br />Lu <br />W L <br />10Z <br />a <br />O N., 9 � O <br />N o"� <br />LLZ <br />W a CD <br />U o <br />WWW.FDSENG.COM ❑ ❑ <br />w <br />0 <br />CV <br />0 <br />CV <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />AL <br />4600 W. Cypress St, Suite 200 i Tampa, FL 33607 <br />www.LennarTampa.com <br />z <br />W� <br />Z� <br /><� <br />Z <br />¢ <br />J <br />w = <br />ICi <br />Z Lu <br />Z S Z <br />�o <br />Uzi z <br />�aE—r <br />Q <br />a - m <br />O o <br />U <br />W�W <br />V m N <br />o <br />I <br />1..V <br />� <br />Z <br />z <br />g <br />Z <br />J <br />= 3 <br />LJJ <br />0 <br />V <br />a <br />Jw <br />= <br />O <br />9 z <br />¢o5 <br />o <br />J <br />L_ <br />2:o <br />Z <br />S782 <br />a <br />!'V <br />Q <br />rag <br />z¢a�� <br />Q <br />o1;_U <br />w <br />Z <br />T-j <br />uj ?y0� <br />LU <br />J <br />Ln <br />W <br />W <br />Q <br />ci z o <br />u'�¢ <br />g~o <br />00 <br />�Q <br />Z <br />Z <br />�9�Z <br />azo <br />Z <br />J� <br />0 <br />06 <br />g <br />= <br />,--1 <br />a <br />U0 <br />o <br />SCALE : AS NOTED <br />DATE : 3/7/2018 <br />TECH: J M UROSKI <br />VERSION NO. 4mO <br />SHEET NO. <br />4.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.