My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3256 Kresterbrooke Ln
Zephyrhills
>
Building Department
>
Building Plans
>
3256 Kresterbrooke Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 7:20:56 AM
Creation date
2/19/2025 9:00:20 AM
Metadata
Fields
Template:
Building Plans
Street #
3256
Location
Kresterbrooke Ln
Contractor
Lennar Homes
Building Plans - Permit #
20292
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br />0 <br />v <br />Q <br />ab <br />00 <br />J <br />N <br />ao <br />2 <br />E <br />-91 <br />00 <br />A D <br />S3 19) <br />H.B.+ <br />U) <br />O <br />OP <br />'- <br />I <br />■ <br />00 <br />17-O8„l <br />a <br />O <br />OWNER'S SUITE �BT � <br />8'-0" CLG. 00 <br />CARPET <br />a <br />36 <br />5-SH <br />- - - - R&S - - - - <br />( <br />I <br />i <br />I <br />I <br />I <br />_ BUILDER TO <br />N PROVIDE <br />W.H. APPLIANCE <br />O PROTECTION <br />REQUIRED <br />7-6" PER <br />PERFBC <br />2 CAR GARAGE <br />$'-0°CLG. <br />20'O„� <br />1-----_----- <br />F <br />I <br />I <br />I <br />I <br />I <br />I <br />I I <br />6" DP-- <br />W.I.C. <br />8'-0" CLG. r" <br />CARPET r <br />rI <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />,J <br />I <br />I <br />I <br />I <br />I <br />I <br />INE <br />y <br />- <br />TIDE <br />L <br />� <br />� <br />+ <br />i� <br />icy <br />`6w <br />I <br />00 <br />5'-4" "I <br />o <br />N <br />(4) 2x4 #2 SYP STUDS FIBERGLASS <br />W/ USP HTT4 @ BASE SURROUND <br />4'-0" <br />I <br />I <br />to <br />I <br />I FAMILY R M <br />I 9'-4" CLG. <br />I CARPET <br />23'-O$" in <br />2668 <br />HANSON <br />BOX @ 36" <br />A.F.F. <br />DRYER VENT <br />HRU ROO <br />I <br />EDGE OF SLAB 2" <br />BEYOND WALL e <br />S3tw60"x36" <br />I l 1 1 <br />I/ 1 I <br />�I <br />I/X NI <br />Ih Q QII <br />J <br />K (4) 2x4 #2 SYP <br />STUDS W/ USP <br />HTT4 @ BASE <br />0I <br />I 0 <br />I p <br />I I 0 <br />Q <br />1 O= <br />I <br />> <br />to <br />I <br />I <br />NOTE: FINISHED <br />ICE WALLS TO BE <br />I FLUSH. VERIFY IN <br />I I FIELD. <br />- - - - - ----- <br />CC D <br />S3 S3 <br />I <br />l <br />I <br />I <br />III <br />I <br />I <br />I <br />I <br />I <br />I <br />l <br />I <br />I <br />III <br />I <br />I <br />I <br />I <br />I <br />o <br />m <br />IT <br />rn <br />TYP @ 1 STORY <br />A <br />S3 <br />O <br />N <br />SHOWER <br />M <br />- <br />T <br />AHU <br />-TILE <br />�� <br />R.A.G. <br />&S <br />-- -- <br />PT. W OPT. D <br />HI <br />0 <br />' <br />2:12 VAULTED CLG. _ <br />� <br />IN <br />- <br />o0 <br />, <br />T <br />_ <br />2868 <br />T <br />3'-10" <br />T-8" <br />co <br />10'-10$„ <br />3A68 <br />7 „ , 4„ <br />I <br />- <br />ENTRY <br />o. 8 -0 CLG. <br />� <br />io <br />I T <br />- <br />T <br />- <br />6„ <br />! <br />10 <br />" 11'-7$" <br />i_ <br />6'-10" i� <br />If <br />HDR AT T-4" <br />------- <br />R&S - <br />--------------- - 2668 mac? <br />4'-7" 8'-8" i:1 5'4 <br />_ I <br />! I I <br />Tq <br />_ �'�° R&S <br />2668 r r------------ <br />14'-6" 64" `o I c" 7-6" <br />4'-0" <br />0o <br />I <br />PATIO CAFE <br />c� 8'-0" CLG. <br />v) CARPET <br />/ I <br />u�> <br />5068 B.F. <br />OPT. <br />RE rt BEDROOM <br />I .. 8-0CLG. <br />I CARPET <br />I <br />19 <br />2,_ " 10'-4" '- <br />2 " <br />BEDROOM 3 <br />as CLG. <br />CARPET <br />10'-42' <br />I <br />c coo W <br />r�`° _ <br />�' <br />1 8r <br />I ILE_ <br />2'-4' I 6-3 <br />Mao <br />4068 B.F. <br />BEDROOM 4 <br />I 8-0 CLG. <br />~ CARPET <br />C7 <br />in <br />a <br />14 <br />_ <br />- <br />- - - - - - <br />o <br />_ <br />-�- <br />_� <br />U)W <br />MC�7 O <br />w <br />/ o==_; <br />T Q= <br />N <br />20'-6$' <br />J <br />U <br />--------� <br />I 1 0 0 <br />I D.W. oo <br />3L _ s4 _ 8 3 <br />0 <br />SI Kwl <br />ISP <br />! <br />i <br />2' <br />/ ��� <br />/ I� <br />/ <br />AC PAD / I <br />_ ,�w <br />PANTY o- <br />r=W <br />oF,I <br />FLAT L . ,n� <br />5-SH T <br />II 16" DEEP <br />M� <br />ti <br />I <br />2" <br />I <br />I <br />00 <br />TYP @ 1 <br />STORY <br />rA <br />S3 <br />V <br />TIE <br />ULT: <br />_ <br />i I <br />I FIBERGLASS MIS <br />I SURROUND © N <br />3s W <br />- - - - - . ---i�' <br />O <br />H.B. <br />29'-8" <br />25-SH <br />EGRESS <br />O <br />15'-10" <br />25-SH <br />EGRESS <br />O <br />19'-6" <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />P(2) <br />- 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />e(2) <br />- 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2600 PSI <br />H6 <br />(2) - 1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2600 PSI <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2600 PSI <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2600 PSI <br />(2) - 2X4 #2 SYP W/ 1/2" Follow Q/S4. See Plan for <br />R.A.G. FLITCH PLATE Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20X26 <br />184X25� <br />S.H. <br />13 <br />20X38j <br />184X37J <br />S.H. <br />14 <br />20X50j <br />184X50 <br />S.H. <br />15 <br />20 X 63 <br />18 4 X 62 j <br />S.H. <br />16 <br />20 X 72 <br />18 4 X 714 <br />S.H. <br />432 <br />27 1/4 X 26 <br />26 X25 4 <br />S.H. <br />433 <br />27 1/4 X 38 j <br />N/A <br />S.H. <br />434 <br />27 4 X 50 1 <br />N/A <br />S.H. <br />433 <br />N/A <br />26 x 37 <br />S.H. <br />434 <br />N/A <br />26 x 50 <br />S.H. <br />J 35 <br />27 4 X 63 <br />26 X 62 1/2 <br />S.H. <br />436 <br />27 4 X 72 <br />26 X 71 1/2 <br />S.H. <br />22 <br />37 J X 26 <br />36 4 X 25 1/2 <br />S.H. <br />23 <br />37 J X 38 i <br />36 j X 37 3/4 <br />S.H. <br />24 <br />37JX50j <br />364X50 <br />S.H. <br />25 <br />37 j X 63 <br />36 4 X 62 1/2 <br />S.H. <br />26 <br />37�X72 <br />364X711/2 <br />S.H. <br />DOUBLE 2 <br />WIDE <br />75" TALL <br />73 } WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 4 X25 4 <br />S.H. <br />33 <br />54 X 38 j <br />52 4 X 37 j <br />S.H. <br />34 <br />54 X 501 <br />524 X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 4 X 62 � <br />S.H. <br />36 <br />54 X 72 <br />52 4 X 71 j <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection. <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection. Openings from a private garage <br />directly into a room used for sleeping purposes shall not be <br />permitted. Door between garage and residence shall be equipped <br />with solid doors not less than 1 3/8" in thickness, solid or <br />honeycomb -core steel doors not less than 1 3/8" thick, or <br />20-minute fire -rated doors. <br />R302.5.2 Duct Penetration. Ducts in the garage and ducts <br />penetrating the wails or ceilings separating the dwelling from the <br />garage shall be constructed of a minimum No. 26 gage (0.48 mm) <br />sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl <br />duct board, or other approved material and shall have no openings <br />into the garage. <br />R302.5.3 Other Penetrations. Penetrations through the separation <br />required in Section R302.6 shall be protected as required by <br />section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated from the dwelling as per the <br />following: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd, or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 518" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills. <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools, Section R4501.17.1.9 <br />All doors and windows providing direct access from the home to <br />the pool shall be equipped with an exit alarm complying with UL <br />2017 that has a minimum sound pressure rating of 85 db at 10 <br />feet. Any deactivation switch shall be located at least 54 inches <br />above the threshold of the access. Separate alarms are not <br />required for each door or window if sensors wired to a central <br />alarm sound when contact is broken at any opening. <br />M1507.2 Recirculation of Air. <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />recirculated within a residence or to another dwelling unit and shall <br />be exhausted directly to the outdoors. Exhaust air from bathrooms <br />and toilet rooms shall not discharge into an attic, crawl space or <br />other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />OPENING PRESSURES <br />ENCLOSED-EXPOSURE"C" <br />OA <br />+29.7 / -30.8 <br />© <br />+29.7 / -39.2 <br />© <br />+28.3 / -30.8 <br />OD <br />+28.3 / -36.4 <br />OE <br />+26.6 / -28.0 <br />O <br />+26.6 / -32.2 <br />GG <br />SEE SN SHEET OH SEE SN SHEET <br />NWED�0 <br />MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />1 +34.0 / -44.8 <br />WALL LEGEND <br />TYP. 2x FRAME WALL <br />1 1 1 1 BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR BEARING <br />ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND <br />REQUIRES NO UPLIFT CONNECTORS TO FLOOR <br />SYSTEM <br />AREA TABULATION "A1" <br />1ST FLOOR LIVING AREA 1936 <br />LIVING TOTAL 1936 <br />GARAGE 416 <br />FRONT ENTRY 20 <br />TOTAL AREA 2372 <br />INSULATION REQ. <br />EXT CONC WALL <br />R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 <br />R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 <br />R-19 KRAFT FACED <br />CONDITIONED CEILING <br />R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION <br />R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />0 V <br />(M <br />0 <br />® m <br />Z N <br />E3J <br />U) <br />N 0 <br />� w <br />C6 <br />°O w <br />G <br />Oa <br />1 <br />CO <br />m N <br />1E <br />U <br />N M <br />0) M <br />C.3L. <br />O o N <br />" cc <br /><t <br />MEN=o <br />o <br />roo-o <br />0) <br />v a v <br />rn Q ci <br />A1 <br />h-C�e.n.0 <br />Z W MN�Z �2 <br />ui N !r a W <br />W �c�a <br />4 <br />�§ <br />a cn Q'rng <br />Z <br />m c N O <br />m n <br />Z`N <br />LLo <br />i <br />° V <br />_ °ems <br />��zO <br />4 <br />To the best of the Engineer"s knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />oz <br /><F <br />wa°d� <br />1=Z�U <br />z <br />0WUJ <br />• ` <br />VOL <br />Q <br />zo <br />L <br />^ <br />li <br />Cr <br />}f 8 <br />z <br />g <br />O <br />L.L_ <br />~ <br />(%� <br />�< <br />� <br />31 <br />adz <br />µµ,I �o <br />rYYV� <br />1-0- <br />U <br />U 0 C <br />0 <br />z za <br />Uj�Qw� <br />a <br />s aQ� <br />z <br />LL p <br />F O <br />w <br />_jT--I <br />to <br />w <br />Q <br />w <br />z <br />� t 5 <br />F W o <br />oda <br />~g <br />�a <br />N <br />co <br />O <br />(6 <br />G� <br />:5 <br />= <br />J <br />of <br />rn <br />V-4 <br />a <br />to <br />o <br />SCALE : AS NOTED <br />DATE : 3/15/2018 <br />TECH: MJAM ES <br />VERSION NOa 4mO <br />SHEET NO. <br />1.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.