Laserfiche WebLink
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />NEMA 1 <br />200 AMP <br />MAIN <br />O <br />200 amp <br />150 amp <br />copper to lights & outlets <br />copper to 20 amp ckts <br />2 copper to WH <br />3 copper to Dryer <br />or 4/0 SER Alu <br />POWER CO. FEEDS j <br />INTERSYSTEM �ILfll <br />4 Bare Cu Ground <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 14, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: <br />unless otherwise noted, <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />� <br />'q^� WEATHERPROOF DUPLEX OUTLET <br />E <br />S.D <br />y <br />P W.P. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />00 <br />o <br />® SPECIAL PURPOSE OUTLET <br />G <br />DUPLEX OUTLET IN FLOOR <br />' <br />220 VOLT OUTLET <br />N <br />WALL SWITCH <br />tb <br />3 THREE-WAY SWITCH <br />¢4 <br />FOUR-WAY SWITCH <br />a'R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED LED CEILING MOUNTED LIGHT FIXTURE <br />00 <br />00 <br />0 <br />WALL MOUNTED LIGHT FIXTURE <br />J <br />0 RECESSED LIGHT FIXTURE <br />O <br />N <br />I <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />F-- I <br />a <br />00 <br />OWNER'S S Y ITE <br />1 <br />ROUGH -IN FOR / <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />U <br />MEN <br />I \ <br />FAMILY RM <br />I G � <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />I U.C. OUTLET <br />FOR DW <br />U.C. OUTLET <br />I <br />GFI <br />r GFI -� ----- -- GFI <br />� I D.W. I <br />L---J <br />1 INK / DIS <br />_ CH _ CHIMES (OPTIONAL) — — <br />PENDANT AS11-1 <br />PB PUSH BUTTON SWITCH (OPTIONAL) / PER SPECS <br />0 <br />�2 PUSH BUTTON SWITCH - DOOR BELLCn <br />r <br />E SD SMOKE DETECTOR to \ <br />= AC PAD <br />`v CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />FLUORESCENT LIGHT FIXTURE <br />O EXHAUST FAN PA 0 CAFE <br />EXHAUST FAN/LIGHT COMBINATION <br />®D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />TELEPHONE (OPTIONAL) <br />© TELEVISION (OPTIONAL) <br />o <br />o <br />® 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />H.B. <br />GF DISC. <br />O THERMOSTAT <br />.o <br />VI] ELECTRIC METER <br />ELECTRIC PANEL <br />ri <br />t DISCONNECT SWITCH <br />°J <br />® SPEAKER (OPTIONAL) <br />N <br />^ ^ <br />M( <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />N <br />G J OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />RECEPT. <br />FOR ALARM <br />SYSTEM <br />JIB <br />u <br />VERIFY METER <br />LOCATION WITH <br />BUILDER <br />IRRIGATION <br />VERIFY LOCATION L GFI @ 44" A.F.F. <br />Dw <br />ELECTRICAL PANEL <br />O I <br />I <br />I <br />I <br />2 CAR GARAGE <br />I <br />I <br />GFI FOR <br />GAR. DOOR <br />GFI <br />GFI @ 44" <br />A.F.F. <br />I <br />� I <br />_ I <br />I <br />L------------ <br />GFI @ 44" <br />A.F.F. <br />' II► � �/IIIIIIIIIIi1111111111111111111111111 <br />r <br />M <br />II (I 111 <br />•' _ _ 111 <br />Ll��ll�i� <br />I�• •- �� • O.- <br />• <br />;��IGHT PRE -WIRE <br />I. •- G <br />ROUGH -IN FOR <br />LIGHT PRE -WIRE <br />MAIN FLOOR ELECTRICAL PLANT <br />SCALE: %4"=1'-0" <br />(D <br />z M <br />0 <br />— o <br />z� <br />Q <br />a <br />U) z <br />w <br />ru <br />�V — <br />O w <br />In CL, <br />0 <br />o <br />i� � H- <br />U <br />r- <br />m <br />NW <br />w <br />� M <br />M <br />� aj <br />T 'O <br />O o N <br />0 <br />U <br />t�00 <br />o -00 <br />Q rn <br />W <br />rn g <br />rn Q o <br />B D. <br />N <br />N �O <br />O p N � � � <br />Z W �� � Z"C�"jmZ <br />� c <br />�U_o.� rsi w <br />LN N N p w <br />UA � E a <br />�.�4�' <br />Zma <br />�0@o0 <br />ya <br />Z 'IT - <br />LL IJ N m ¢ a <br />0 0 v O <br />WVM FDSENG.COM 11 I] <br />0 <br />rn <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />L NAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />�o <br />Lu <br />Z <br />t,,a�ir <br />J <br />Q— <br />zw�O <br />= w Z <br />J&Z� <br />Q <br />rL au <br />�' . <br />O <br />� <br />U <br />m o <br />L <br />Q <br />Lu <br />> <br />a <br />U <br />¢Z <br />fZ <br />Z <br />rl <br />W <br />O <br />a <br />J <br />U <br />O <br />ono <br />o <br />LL <br />¢8 <br />N <br />Q <br />a¢ <br />Q <br />d' <br />—0,0 <br />o <br />Z <br />Z <br />,--I <br />g" & <br />J <br />r-1 <br />w <br />Q <br />LJJ <br />X <br />¢ Z 0 <br />ga~ <br />N <br />l0 <br />Z <br />Z <br />�¢Z <br />aay Z S <br />co00 <br />Z <br />2 <br />7� O <br />In <br />0 <br />SCALE : AS NOTED <br />DATE : 3/15/2018 <br />TECH: MJAM ES <br />VERSION NO- 4n0 <br />SHEET NO. <br />4.0 <br />