My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3258 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3258 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 4:11:22 AM
Creation date
2/19/2025 9:00:35 AM
Metadata
Fields
Template:
Building Plans
Street #
3258
Location
Moulden Hollow Dr
Contractor
Lennar Homes
Building Plans - Permit #
19518
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
12 <br />5� <br />12 <br />;Z�5 <br />REAR ELEVATION - B1 <br />SCALE: 1 /4"=1'-0" <br />28'-0" RIDGE VENT <br />T.O.M. _ — — <br />HDR HGT. <br />1'-0" 2'-6" <br />TEXTURED <br />o CEMENTICIOUS <br />00 00 FINISH ON C.M.U. <br />zo (TYP.) <br />12 <br />�5 <br />TEXTURED 2,-O„ <br />CEMENTICIOUS01 <br />FINISH ON C.M.U. <br />(TYP. ) <br />35 F.FL.-----��--------------------------------------I------------------------- -- — — —-----------I-------- <br />RIGHT ELEVATION - B1. <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />.G.C. VERIFY ROOF PITCH" <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />"ELECTRICAL SPECIFICATION NOTES" <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.6 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.6.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.6.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.6.3 Water-Resisitive Barriers. <br />Water-resisitive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paperbacked <br />stucco lath) over an approved synthetic house wrap. <br />R703.8 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry contructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 5th Edition <br />(2014) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated.Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />-CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN — <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SO. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SO. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. <br />• O'HAGIN WEATHERMASTER (Shingle Roof) - 72 SQ. IN. OF NET FREE AREA/ FT. <br />" (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 72 = Amount of O'Hagin Vents Needed <br />• LOMANCO DECK -AIR (Shingle Roof) - 9 SQ. IN. OF NET FREE AREA/ FT. <br />Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In, Needed) / 9 = Linear Ft. of Deck -Air Needed) <br />• O'HAGIN (Tile Roof) - 86.25 SQ. IN. OF NET FREE AREA / VENT <br />-Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 86.25 = Amount of O'Hagin Vents Needed <br />(D1� <br />Z M <br />o <br />_ CD <br />Z � <br />Z <br />Q <br />a. <br />co z <br />cn c� <br />Q) N <br />4—J w <br />0 <br />U <br />Ow <br />~ <br />In <br />ru <br />0 <br />0 0 <br />U <br />a W E <br />w <br />aM CO <br />: fO M <br />Ooo <br />—i3 <br />U (A <br />L u. w <br />oYT- <br />Y <br />Q m <br />t0 O q <br />0) <br />N C B D C <br />;$oo�j <br />A <br />-0 Z <br />Z per,( q <br />ii ri7 LL i <br />2 <br />N <br />21 ••,Q <br />�\ <br />S S <br />z H &41011111111 <br />LIL <br />W 04 <br />N Q <br />OCD 0 <br />U <br />❑❑ <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code Sth Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />0 <br />0 <br />z cV <br />0 0) N <br />r> -IU-)MCO <br />M <br />Q <br />'�t• <br />i2 cn •� <br />CO <br />Ce V CL 00 <br />Q <br />z <br />E U <br />� z� <br />W J� <br />0z <br />w� <br />za <br />f t- <br />z <br />w Z 0 <br />UOp <br />_O <br />zwwof <br />2A Z <br />dz� <br />2 <br />0o <br />W <br />Lu <br />"quo <br />s... <br />J <br />Z Z <br />0 <br />4 U <br />` <br />1� <br />z Z <br />z <br />N <br />M <br />/Q'^ <br />VJ <br />z <br />O <br />U <br />= <br />< <br />�z <br />z <br />O <br />mow•• <br />LL <br />U>186 <br />a a <br />N <br />a <br />zaoJ <br />w it Q <br />z <br />^� <br />w CY <br /><<017) <br />W <br />J <br />r;l <br />W <br />LU <br />Z <br />o Z o0 <br />.ate <br />N <br />kof <br />z <br />tj <br />Z <br />Z <br />O <br />r <br />^ <br />Z <br />g <br />lJJ <br />= <br />� o <br />` w <br />rn <br />,-i <br />a <br />to <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: MJAMES <br />VERSION NO. 2mO <br />SHEET NO. <br />3.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.