Laserfiche WebLink
DOOR JAMB (REFER iX4 1/2" DRYWALL <br />DOOR JAMB (REFER 1 X 4 1/2" DRYWALL <br />DOOR JAMB (REFER <br />TO SHT. SDW2-K1 <br />1 X 4 1/2" DRYWALL <br />TO SHT. SDW2-K1 <br />P.T. <br />TO SHT. SDW2-K1 <br />FOR CONN. DETAILS <br />FOR CONN. DETAILS <br />FOR CONN. DETAILS <br />1 X 4 <br />1 X 4 <br />3-1/4" LONG X 3/16" 0 <br />1 X 4 <br />FURRING <br />3/16"0 X 3" LONG FURRING <br />TAPCONS <br />3/16"0 X 3-1/2" LONG <br />FURRING <br />TAPCON. INTO <br />STAGGERED @ 16" <br />TAPCONS STAGGERED <br />2X8 <br />BLOCK@ SPACING „ <br />1 <br />DETAIL <br />1X8 P.T. <br />O.C. 2-ROWS INTO <br />STAGGERED @ 16 O.C. <br />2-ROWS INTO <br />1X8 <br />PER MANUFACTURE <br />MASONRYTHROUGH 11 <br />1-1 /2 DETAIL <br />MASONRY THROUGH <br />3" DETAIL <br />ix4 P.T. & 1x8 P.T. <br />1x8 P.T. & 2x8 P.T. <br />3/16" x 3 -1/2" <br />TAPCON @ 16" <br />O.C. & 4" FROM <br />1X4 P.T. 3/16" x 3 -1/2" <br />DOOR JAMB (REFER <br />1 X 4 1/2" DRYWALL <br />DOOR JAMB (REFER <br />EACH END W/ MIN <br />DOOR JAMB (REFER TAPCON <br />TO SHT. SDW2-K1 FOR <br />TO SHT. SDW2-K1 <br />2" EDGE DIST. <br />TO SHT. SDW2-Kl <br />CONN. DETAILS <br />FOR CONN. DETAILS <br />FOR CONN. DETAILS <br />10d @ 12' O.C. <br />1 X 4 <br />FURRING <br />2X8 P.T. WITH 3/16"0 X 3" <br />2x P.T. AS REQ'D <br />2X8 P.T. <br />LONG TAPCONS <br />STAGGERED @ 16" O.C. <br />2X8 <br />2x DETAIL <br />2 1/4" DETAIL <br />2-ROWS INTO MASONRY <br />3-1 /4" DETAIL <br />BUILDOUT @ OVER SIZE DOOR -WINDOW ROUGH OPENINGS rc <br />SCALE: N.T.S. SS <br />2x8 P.T. BUCK -CONNECT TO BLOCK <br />W/ 1/4" x 3 1/4" TAPCON ( 1 1/4" MIN. <br />EMBEDMENT INTO BLK.) <br />1 X 4 FURRING <br />BLOCK HEADER <br />1/2" DRYWALL <br />8d NAILS AT 8" O.C. AT BUCK <br />2 x 8 45" DIAGONAL (4) 10d NAILS INTO <br />BRACE(S) 2 x 8 BRACE/ BLKG. <br />7/16" OSB <br />BUILT UP PLWD. BUCK ARCH PANEL CUT HOLE IN O.S.B. FOR <br />SCRIBE (NOTCH) POLY -CELL IN THIS AREA <br />BACKSIDE TO FIT ARCH (4) 10d NAILS INTO 2 x 8 <br />CONNECT W/ 8d NAILS BRACE/ BLKG. <br />INSTALL WDW. SCREW ANCHOR 2 x 4 SOLID BLKG. (FULL WIDTH OF WALL) BTWN. OSB <br />INTO ARCH BLKG. PER ARCH FACES W (4) 10d NAILS THRU OSB INTO 2 x 8 <br />INSTALLATION DETAILS A -A PROVIDE TAPCON PER WDW. INSTALLATION DETAILS OR THRU --\ <br />1-1/2" THK. OR MORE BUCK WITHIN 6" MIN. OF START OF ARCH <br />ARCH DETAIL J <br />SCALE: N.T.S. SS <br />BLOCK HEADER <br />1 X4 FURRING <br />8d NAILS @ 8" O.C. AT BUCK <br />PROVIDE 2 x 8 DIAG. BRACE BT <br />VERT. BRACES WHEN HGT. OF <br />BRACE EXCEEDS 24" <br />2 x 8 VERT. BRACE(S) <br />BUILT UP PLWD. BUCK - <br />SCRIBE (NOTCH) BACKSIDE <br />TO FIT ARCH CONNECT W/ <br />8d NAILS <br />INSTALL WDW, SCREW <br />ANCHOR INTO ARCH BLKG. <br />PER INSTALLATION DETAILS <br />1/4" MAX <br />it 2'-0" <br />SOLID BLKG. AT TOP BTWN. <br />ARCH BLKG. & BUCK —� <br />- SECTION <br />A -A <br />81, <br />1/4" x 3 1/4" TAPCONS <br />—LEAVE A CUT OUT IN O.S.B. ON THE <br />INSIDE TO ALLOW FOR INSULATION <br />TO BE INSTALLED <br />�2 x 8 45 DIAGONAL BRACE AT EA. <br />FACE OF ARCH W/ (3) 10d NAILS <br />AT EA. END <br />PROVIDE TAPCON WITHIN <br />4" MIN. OF BRACE <br />START OF ARC <br />4' MAX. RAD. <br />2 <br />x 8 BUCK - CONNECT TO BLOCK SECTION <br />SE <br />WITH <br />1/4" x 31/4" TAPCON (1 1/4" MIN. <br />11/4" MAX EMBEDMENT INTO K.) <br />4 2,41 8" <br />SOLID BLKG. AT TOP BTWN. ARCH <br />BLKG. & BUCK <br />2 x 8 VERT. W/ (2) 10d <br />NAILS AT EA. END <br />PROVIDE (2) MIN. <br />TAPCON AT EA. SIDE <br />BUCK - (1) WITHIN 4" <br />LEAVE A CUT OUT IN O.S.B. ON T <br />MIN. OF START OF <br />INSIDE TO ALLOW FOR INSULATION <br />ARCH <br />TO BE INSTALLED <br />7/16" OSB ARCH PANEL <br />x 4 SOLID BLKG. (FULL WIDTH OF WALLS) <br />START OF ARC <br />7fq"`2 <br />BTWN. OSB ARCH FACES W/ (4) 10d NAILS EQUAL EQUAL <br />THRU OSB INTO 2 x 8 <br />4' MAX. RAD. <br />ARCH DETAIL rK <br />B_B <br />SCALE: N.T.S. SS <br />GLASS BLOCK INSTALLATION NOTES <br />A) COVER SILL AREA WITH A HEAVY COAT OF ASPHALT EMULSION. ALLOW EMULSION TO DRY <br />AT LEAST 2 HOURS BEFORE PLACING MORTAR. <br />B) ADHERE EXPANSION STRIPS TO JAMBS AND HEAD. MAKE CERTAIN EXPANSION STRIP <br />EXTENDS TO SILL. <br />C) SET A FULL MORTAR BED JOINT, APPLIED TO SILL. <br />D) SET LOWER COURSE OF BLOCK. MAINTAIN A UNIFORM JOINT WIDTH OF 3/8" PLUS OR MINUS <br />1/8". ALL MORTAR JOINTS MUST BE FULL AND NOT FURROWED. ALL MORTAR SHALL BE <br />TYPE "S" OR "N". STEEL TOOLS MUST NOT BE USED TO TAP BLOCKS INTO POSITION. (PLACE <br />A RUBBER CRUTCH TIP ON END OF TROWEL TO TAP BLOCK INTO POSITION.) DO NOT <br />REALIGN, TAP, OR OTHERWISE MOVE BLOCK AFTER INITIAL PLACEMENT. FOR SOLID GLASS <br />BLOCK IT MAY BE NECESSARY TO USE WEDGES IN THE MORTAR JOINTS OF THE LOWER <br />COURSES TO PREVENT THE MORTAR FROM BEING "SQUEEZED" OUT. <br />E) INSTALL PANEL REINFORCING IN EVERY OTHER MORTAR BED HORIZONTALLY AND IN JOINTS <br />IMMEDIATELY ABOVE AND BELOW ALL OPENINGS WITHIN PANELS. (THE SAME SPACING <br />SHALL APPLY TO PANEL ANCHORS WHEN USED AT JAMBS AND HEADS IN LIEU OF CHANNEL <br />OR CHASE SURROUNDS.) RUN REINFORCING CONTINUOUSLY FROM END TO END OF PANELS. <br />LAP REINFORCING NOT LESS THAN 6 INCHES WHENEVER IT IS NECESSARY TO USE MORE <br />THAN ONE LENGTH. DO NOT BRIDGE EXPANSION JOINTS WITH REINFORCING. INSTALL <br />REINFORCING AS FOLLOWS: <br />* PLACE LOWER HALF OF MORTAR IN BED JOINT. DO NOT FURROW. <br />* PRESS PANEL REINFORCING INTO PLACE. <br />* COVER PANEL REINFORCING WITH UPPER HALF OF MORTAR BED AND TROWEL <br />SMOOTH. DO NO FURROW. <br />F) PLACE FULL MORTAR BED FOR JOINTS NOT REQUIRING PANEL REINFORCING -DO NOT <br />FURROW. MAINTAIN UNIFORM JOINT WIDTH. <br />G) SET SUCCEEDING COURSE OF BLOCKS. SPACE AT HEAD OF PANEL AND JAMBS MUST <br />REMAIN FREE OF MORTAR. <br />H) STRIKE JOINTS SMOOTH WHILE MORTAR IS STILL PLASTIC AND BEFORE FINAL SET. AT THIS <br />TIME RAKE OUT ALL SPACES REQUIRING SEALANT TO A DEPTH EQUAL TO THE WIDTH OF THE <br />SPACES. REMOVE SURPLUS MORTAR FROM FACES OF GLASS BLOCKS AND WIPE DRY. <br />TOOL JOINTS SMOOTH AND CONCAVE, BEFORE MORTAR TAKES FINAL SET. (REMOVE <br />WEDGES FROM LOWER COURSES OF SOLID BLOCKS AND POINT THE VOIDS WITH MORTAR.) <br />1) AFTER FINAL MORTAR SET (APPROX. 24 HOURS), INSTALL PACKING TIGHTLY BETWEEN <br />GLASS BLOCK PANEL AND JAMB AND HEAD CONSTRUCTION. LEAVE SPACE FOR SEALING. <br />J) APPLY SEALANT EVENLY TO THE FULL DEPTH OF RECESSES IN ACCORDANCE WITH THE <br />MANUFACTURER'S APPLICATION MANUAL AND INSTRUCTIONS. <br />K) A MAXIMUM OF 60 SQUARE FEET OF GLASS BLOCK MAY BE INSTALLED IN ANY OPENING. <br />FOR WIND SPEEDS UP TO 110 MPH*, PER PITTSBURG CORNING RECOMMENDATIONS FOR <br />INSTALLATION OF GLASS BLOCK. <br />20 ga. PANEL <br />ANCHOR -\ <br />9 ga. PANEL <br />REINFORCING <br />(EVERY OTHER <br />COURSE) <br />170 MAE <br />'Mr. <br />EXPANSION STRIP <br />PROVIDE 2x <br />CONT. W/ (3) <br />12d NAILS <br />1/4" EXPANSION BOLT (2 <br />PER ANCHOR) <br />EXPANSION STRIP <br />-SEALANT <br />6" MIN. LAP SPLICE W/ <br />REINFORCING PANEL <br />PROPER INSTALLATION MAx.B <br />FILL SOLID <br />BOTH CELLS <br />#5 REB, <br />(T1'P,) <br />STD. 90' <br />HOOK (1 <br />31L <br />EJ/iZ <br />1 <br />7/ <br />5" <br />FIRST 2 COURSEJ <br />LNOTCH WEB AT <br />CAPACITY = 945 # FOR 1 STRAP <br />= 1890 # FOR 2 STRAPS <br />I -PLY PRE-ENGINEERED TRUSS <br />USP RT16M W/ (8) NA11 NAILS & (6) 4' x 21" <br />TAPCONS <br />(IF TRUSS IS 2 PLY INSTALL USP HTWM16 W/ (6) <br />10d NAILS x 12' NAILS AND <br />(4) 4" X 1 2" WEDGE BOLTS [ (1) STRAP = 1225 # , <br />(2) STRAPS 2450#]) <br />BOND BEAM OR CAST <br />IN PLACE BEAM <br />RETROFIT TRUSS DETAIL <br />N.T.S. <br />2X6 SYP #2 CONT. (MATCH TRUSS DEPTH <br />IF TRUSSES USED) W/ (3) #6 X 4%' WOOD <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY <br />WALL USE (3) 1/4" X 3 112" TAPCONS AT 16" <br />O.C. <br />JACK TRUSS PROVIDED BY <br />TRUSS COMPANY OR <br />2x6 #2 SYP @ 24" O.C. <br />ROOF SHEATHING ATTACHED <br />PER NAILING SCHEDULE <br />(5) -12d NAILS <br />2X6 TO 2X4 , <br />NOTE: <br />SEE GLASS BLOCK INSTALLATION NOTES. <br />SEALANT <br />GLASS BLOCK DETAIL <br />GLASS BLOCK SHALL BE INSTALLED PER THE FLORIDA BUILDING CODE RESIDENTIAL SECTION R160 <br />12 <br />2X4 SYP #2 CONT. (MATCH TRUSS DEPTH <br />IF TRUSSES USED) W/ (2) #6 X 4%" WOOD <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY <br />WALL USE (2) 1/4" X 3 1/2" TAPCONS AT 16" <br />O.C. <br />SECTION @ ENTRY L <br />SCALE: 3/4" = V-0" SS <br />(1) #5 BARS CONT. <br />TOP WITH MIN. 3" <br />COVER <br />GRADE <br />M <br />r� <br />6'-0" <br />MASONRY WALL. SEE PLAN FOR <br />REINFORCING. PROVIDE LOWER <br />HOOKED DOWEL <br />W.W.M. AT PERIMETER <br />WHERE THIS CONDITION <br />OCCURS <br />�i F.F. <br />(2) #5 REBAR. MIN. 3" <br />COVER EA. WAY <br />SECTION AT DEEP MONO FOUNDATION <br />SCALE: 3/4" = V-0" <br />FILLED CELL PER <br />FOUNDATION PLAN <br />�R <br />YP.) <br />THE <br />S <br />x0 <br />TRUSS <br />2X4 SYP <br />EACH TRUSS <br />CONNECTOR <br />SEE LINTEL- <br />SCHED. <br />PRECAST LINTEL <br />I IAIAr'r`CDTADI C IAICTAI I TInAI <br />FILLED CELL INSTALLATION H <br />SCALE: N.T.S. Ste+ <br />2 X 4 #2 SYP SCAB TO SIDE OF <br />TRUSS AS SHOWN FOR O.H. UP TO 2'-6" <br />* DOUBLE 2x4 SCAB FOR 2'-6" TO 4'-0" O.H. <br />(2) 10d NAILS @ 8" O.C. <br />TO TRUSS TOP CHORD <br />aTy PLYWOOD SHEATHING <br />SEE ELEVATION <br />FOR OVER HANG <br />(MAX. 4'-0") <br />BLOCKING AS <br />REQUIRED <br />TO SUPPORT <br />SOFFIT <br />SECTION @ ROOF EXTENSION rm <br />SCALE: 3/4" = V-0" SS <br />--,PP cuPFT n2 AND <br />FOR <br />HTT16 W/ (18) -16d NAILS TO <br />STUDS & (1) - 5/8" DIA. ALL <br />THREAD ROD EPDXIED W/ <br />SIMPSON "SET" EPDXY MIN. <br />5" EMBEDMENT & 3" MIN. <br />EDGE DISTANCE <br />RETROFIT FOR MISSING MSTAM STRAP <br />SCALE: 3/4" = V-0" <br />2"x BOT. PLATE W/ (2) 1 Od @ 6" O.C. <br />3/4" PLYWOOD DECKING GLUED ATTACHED WALL SHEATHING TO <br />6" O.C. AND IDGES AND LED W1 8d OMpMONFIE <br />O. <br />LD� �BOTTOM PLATE W/ 8d 4" <br />O. <br />2 ROWS STAGGERED <br />Y2x BAND JOIST W/ FACE NAIL 10d <br />@ TOP & BTTM CHORD, AND (8) <br />FACE NAILS 10d @ TRUSS VERT. <br />WEB <br />B <br />TTE: <br />P SHEATHING TO <br />TTOM OF BAND <br />P HGAM10 @ 12" O.C. w/4-SDS <br />1/4x1 1/2" SCREWS INTO BAND <br />JOIST & (4) 3/16"x1-3/4" WEDGE <br />BOLTS INTO K.O. BLOCK <br />RETROFIT FOR MISSING EMBEDDED STRAP <br />SEE TYP. 2-STORY WALL SECTION FOR ADDL. INFO <br />FILL 1st4 COURSES <br />SOLID W/GROUT <br />a <br />FOR OVERHANGS BETWEEN OVER 1 1/2" <br />CONTACT ENGINEER OF RECORD FOR <br />FURTHER INSTRUCTIONS. -' <br />OVERHAN <br />RETROFIT WALL OVERHANG DETAIL (NTS <br />FOR OVERHANGS BETWEEN 3/4" TO 1 1/2" <br />NOTE: FOR OVERHANGS LESS THAN 3/4"- NO REPAIR REQ'D. <br />1'-0" 5'-0" <br />NISH <br />SCALE: N.T.S. <br />41 Y <br />> D D <br />° ° D #5 BAR <br />DD D' 10 o D Q ° 4 CENTERED W/ <br />9T H D IN TOP o <br />KNOCKOUT/ N <br />° CHAIR BLOCK <br />MONO FOOTINGI'4 D <br />SIZE AND REINF. PER PLAN <br />AND SECTION DETAILS -I ° <br />_I ° <br />CLEAN FILL D °. D <br />DIRT 6 z <br />° STANDARD o <br />0 99 HOOK �+ <br />#5 BAR IN <br />FILLED CELL -, - <br />�,- ° e °•° ° v� - ,or <br />STEMWALL FOOTING SIZE AND <br />MONO TO STEMWALL FOOTING REINF. AND STEMWALL <br />SECTIONN DETAILS <br />SCALE: 3/4" = V-0" <br />NOTE: IF RETROFIT FILLED CELL CONDITIONS <br />EXCEED (3) PER PROJECT, CONTACT ENGINEER OF RECORD <br />FOR ADDITIONAL INSTRUCTION. <br />EXISTING BOND BEAM. <br />�- DRILL 3/4"X6" MIN. HOLE <br />SET BAR IN EPDXY <br />CAP TO PREVENT LEAKAGE <br />#5X6' EMBEDDED INTO <br />EXISTING BOND BEAM <br />0 <br />co <br />a <br />2 <br />FILL CELL FULL HEIGHT W/ <br />o <br />v <br />NON SHRINK GROUT. <br />w <br />J <br />a-u- <br />A <br />1 <br />13 <br />g <br />v <br />5X6' EMBEDDED INTO <br />z <br />EXISTING FOOTING <br />N <br />DRILL 3/4"X6" MIN. HOLE <br />/ SET BAR IN EPDXY <br />-1 11CV/" IAI /1/'lA il" <br />-1 SAW CUT <br />-�— EXISTING FOOTING A SECTION <br />1 SCALE: N.T.S. �j <br />RETROFIT FILLED CELL DETAIL <br />SCALE: N.T.S. <br />U) <br />ly <br />=w <br />w <br />LL <br />w¢ <br />3r, <br />a <br />= <br />0 <br />aa <br />~ <br />N <br />N <br />Ill �OUp <br />Ow <br />Q <br />_. <br />`o <br />J <br />i Z LL -.J <br />w <br />TUi <br />000 <br />�a <br />;z <br />— O v Z <br /><, <br />rY: <br />W. <br />>-z <br />0 Lij <br />0 <br />w 0 F- 0 <br />Z <br />U Z U-) U <br />y Q=(D <br />wz�z <br />(D❑ <br />J_ <br />❑a <br />❑ <br />U) <br />w <br />2wF= <br />—❑�m <br />LU <br />I <br />�F <br />z <br />Q <br />0 4) h E <br />-0 <br />W L 0 <br />m N W <br />f�♦♦ G <br />N V 1 <br />-� 10 <br />L L O <br />2 o <br />u- O o R ¢Q <br />t ��� <br />}� <br />"(A w Q v <br />W L �M 0) <br />w <br />WQ <br />�W vi w0� <br />0�zl-Q <br />Zp��U0��0(D <br /><<<OxJZ��OZ�pf-QW0 <br />Q U <br />�w�nQ 000mz <br />Z0w <br />Q <br />U <br />o <br />�OZ <br />�(w j�nLu zLL�Qp <br />Q~Wp�1a-�Zwz <br />� <br />il <br />2L) <br />o D�Q� <br />OLL <br />Y Z Q <br />Q <br />O <br />N <br />Z W <br />0� <br />(n O <br />�F-MO <br />Q c M <br />U) LL ti <br />QWQL? <br />- w 0- M <br />Q >- Q co <br />Z 0 H <br />W <br />W <br />JC) <br />(o <br />0 <br />N <br />1 <br />d7 <br />N <br />4 <br />0 <br />c <br />L <br />O <br />0 <br />> <br />Lo <br />O <br />z z <br />aO <br />cu <br />co <br />C <br />V5E2o <br />❑ a <br />>_ <br />UJ <br />Oa-=Q <br />♦♦ ^^ <br />vJ <br />1--1 <br />Z <br />W F- � <br />~mOa <br />H = Z <br />� <br />`=�1�"11 <br />v <br />Z > J <br />r <br />2 <br />V <br />i-�z <br />�JoZ <br />Z ILL <br />w 00 <br />O <br /><�Z <br />O <br />Q (� <br />V <br />13- `nzLu <br />z <br />z N <br />Sao <br />Z <br />U <br />U <br />J <br />MO <br />W <br />z <br />z <br />J <br />v <br />M <br />(Y� <br />LAST PLOT DATE <br />May. 24, 17 <br />f+ <br />O <br />STRUCTURAL <br />J <br />l <br />DETAILS-RETRO <br />FIT <br />