Laserfiche WebLink
WEATHER <br />RESISITIVE <br />BARRIER <br />^' ^ ' 10 WEATHER <br />✓E BARRIER & <br />IARILY SECURE <br />EXTERIOR <br />SHEATHING <br />WOOD FRAME CONSTR. <br />SELF -ADHERED FLASHIN <br />BY LAPPING DOWN -� <br />OVER RIM JOIST AND UP <br />WALL BY 6 IN. <br />WEATHER <br />RESISITIVE � <br />BARRIER SEAL TOPS OF JOISTS <br />UNDER DECKING <br />ED FLASHING (SEE DETAIL WP07) <br />HEAD FLASHING TIE-IN INSTRUXTIONS: <br />1. Cut, fold up & temporarily secure weather resistive <br />barrier above header to allow for flashing <br />installation <br />2. Self -adhered flashing plus head flashing under <br />weather resistive barrier <br />3. Fold weather resistive barrier back over head 2 <br />flashing and seal with tape <br />SELF -ADHERED FLASHING Scale: NTS <br />FLANGED WINDOW WP01 <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />S <br />DO NO- <br />BOTTOI <br />FLANGE <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />WP04 <br />E <br />AM <br />WEATHER RESISTIVE <br />BARRIER <br />DOOR ROUGH OPENING <br />3/4"-V BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />�- SELF -ADHERED FLASHING <br />SUBFLOOR <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A <br />3/4"-1" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLEE1 <br />THRESHOLD OF DOOR AP <br />UP JAMB 6". USE LIQUID t <br />OR EQUAL WEATHER PR( <br />SECTION -A (SEE DETAIL WR <br />SELF -ADHERED FLASHING <br />SEAL TOPS OF JOISTS <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />SELF-ADHER <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />r LI1J1 IIIYV rLf1J1 IIIYV <br />2 <br />SELF -ADHERED FLASHING IWPO71 SELF -ADHERED FLASHING <br />DECK JOIST OUTSIDE CORNER <br />RIM JOIST <br />2; <br />WP02 <br />STALL SELF -ADHERED <br />ASHING JAMB & HEAD <br />ASHING, SEE <br />ANGED WINDOW <br />EE DETAIL WP01) <br />__LF-ADHERED FLASHING, <br />(TEND A MINIMUM 6" <br />RTICALLY FROM <br />)TTOM OF <br />-IRESHOLD <br />WP05 <br />SELF -ADHERED FLASHING <br />PATCH <br />HERED FLASHING <br />1 <br />2 <br />4 <br />5 <br />WINDOW UNIT <br />SLOPE <br />0.3 in: 12.0 in <br />(0.6 cm : 30.5 cm) <br />SELF -ADHERED FLASHING <br />EXTERIOR <br />CEMT. FIN. <br />BUILDING PAPER <br />I- WIRE LATH <br />SELF -ADHERED FLASHING <br />CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER <br />MECHANICALLY FASTEN IF RUBBERIZE^ AODUAI -r <br />NEEDED IN CORNERS RUBBERIZED ADHESIVE <br />THROUGH SELF -ADHERED ASPHALT ADHESIVE <br />FLASHING SELF -ADHERED FLASHING <br />SCORED <br />RELEASE P/ <br />SELF -ADHERED FLASHING <br />INSIDE CORNER <br />Ground_1_7 <br />d n a. .Q 'd A <br />c .4 111 <br />d d Q ,a c 2 <br />a od <br />c <br />Foundation Wall .d <br />a. <br />G d <br />FOUNDATION WEEP SCREED <br />4) <br />WP03 <br />(BEFORE FOLDING, SCORE <br />RELEASE PAPER TO EXPOSE <br />ADHESIVE AS SHOWN) <br />z <br />s <br />4 <br />6 <br />7 <br />Water Resistant Barrier <br />Lath <br />Sheathing <br />Stucco <br />WP09 <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW <br />GENERAL FLASHING AND WATERPROOFING METHODS TO BE USED. <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS <br />TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND <br />ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2.1 <br />Detail Instructions <br />Refer to the number marked as l # l in each detail that corresponds <br />to the numbered items in theist of instructions below- <br />1 . Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water <br />shedding laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on <br />demand, embedded in the adhesive layer) - for ease of <br />installation and to minimize scoring cuts <br />5. Remove all release paper per standard installation instructions <br />and adhere to substrate using a square piece of flashing <br />material (611 x 6" Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing <br />accordingly to fit tight to corner <br />8. Mechanically fasten as necessary <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />- Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />-7/16" O.S.B. <br />sheathing <br />- Metal <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain <br />Bottom of <br />Weep Screed <br />1 1/2"to 2" <br />Above Roof <br />Sheathing <br />FLASHING REQUIREMENTS <br />R612.12 Flashing, Sealants and Weatherstripping. Flashing and sealants for exterior windows <br />shall comply with Section R703.8. <br />R703.2 Weather -resistant sheathing paper. One layer of No.15 asphalt felt, free from holes and <br />breaks, complying with ASTM D 226 for Type 1 felt or other approved water -resistive barrier <br />shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be <br />applied horizontally, with the upper layer lapped over the lower layer not less than 2 inches (51 <br />mm). Where joints occur, felt shall be lapped not less than 6 inches (152 mm). The felt or other <br />approved material shall be continuous to the top of walls and terminated at penetrations and <br />building appendages in a manner to meet the requirements of the exterior wall envelope as <br />described in Section R703.1 <br />Exception: Omission of the water -resistive barrier is permitted in the following situations: <br />1. In detached accessory buildings. <br />2. Under exterior wall finish materials as permitted in <br />R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a <br />manner to prevent entry of water into thewall cavity or penetration ofwater to the building <br />structural framing components. Self -adhered membranes used as flashing shall comply with <br />AAMA 711. The flashing shall extend to the surface of the exterior wall finish. Approved <br />corrosion -resistant flashings shall be installed at all of the following locations: <br />1. Exterior window and door openings. Flashing at exterior window and door openings shall <br />extend to the surface of he exterior wall finish or to the water -resistive barrier for subsequent <br />drainage. Flashing at exterior window and door openings shall be installed in accordance with <br />one or more of the following or other approved method: <br />1.1 The fenestration manufacturer's written flashing instructions. <br />1.2 The flashing manufacturer's written installation instructions. <br />1.3 In accordance with FMA/AAMA 100, FMA/AAMA 200, or FMA/WDMA 250. <br />1.4 In accordance with the flashing method of a registered design professional. <br />2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with <br />projecting lips on both sides under stucco copings. <br />3. Under and at the ends of masonry, wood or metal copings and sills. <br />4. Continuously above all projecting wood trim. <br />5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame <br />construction. <br />6. At wall and roof intersections. <br />7. At built-in gutters. <br />R703.15 Drained assembly wall over mass assembly wall. Where wood frame or other types of <br />drained wall assemblies are constructed above mass wall assemblies, flashing or other <br />approved drainage system shall be installed as required by R703.8. <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />_Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />N <br />C_ <br />i <br />_ <br />Ca <br />N <br />U <br />N <br />O <br />(1) <br />Q) <br />0 <br />co <br />U) <br />O <br />= <br />0 <br />O <br />Lt_ <br />(a 6-0 <br />�p <br />> <br />U) <br />.U) <br />" <br />0 <br />0_ <br />1E <br />Cc6 <br />Q <br />E <br />Z <br />Z <br />LU <br />J <br />o <br />,o$ °•a, All inside and <br />outside corner will <br />°•o.o o need to be miter <br />Cement Plaster '•° °•o•o • , o•, cut and caulked all <br />in accordance .o• a,o,, butt joints need to �a <br />with ASTMC926 • ' $•o•0 8 ,0 ' becaulked using � <br />over wood 2nd Stampede or sim. <br />floor - caulk for all Q C_ <br />CD <br />O =3 <br />0 <br />Cement 0- <br />Plaster <br />over block (1)1 st floor CZ <br />CIO <br />Lu <br />z <br />z <br />Note: ¢ <br />The building paper and metal lath must be a <br />installed over the top of the weep screed. WEEP SCREED DETAIL <br />NOT USED WP1 0 NOT USED WP1 1 NOT USED WP12 SCALE: NOT TO SCALE SHEET NO. <br />WP1.0 <br />