NOTES: <br />ELECTRICAL DETAIL: <br />ELEC <br />METER <br />FIRST FLOOR ELECTRICAL PLAN A <br />1 /4" = 1 '-011 <br />SECOND FLOOR ELECTRICAL PLAN A <br />1 /4" = 1'-0" <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF (GENERAL) <br />KITCHEN <br />BATHROOM <br />LAUNDRY ROOM <br />EXTERIOR WATERPROOF <br />GARAGE GENERAL PURPOSE <br />RANGE <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. ALL <br />WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR THE <br />INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY THE <br />2011 NFPA 70 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER 2011 NEC. <br />7. IN ALL AREA SPECIFIED IN NEC 2011 210.52, ALL 125 VOLT, 15 <br />AND 20 AMP RECEPTACLES SHALL BE LISTED TAMPER -RESISTANT <br />RECEPTACLES. <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER N.E.C. 210.8 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE <br />LEVEL NOT INTENDED AS HABITABLE ROOMS AND <br />LIMITED TO STORAGE AREAS, WORK AREAS, AND <br />AREAS OF SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP <br />SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPACLES ARE INSTALLED WITHIN 6 FEET <br />OF THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED IN LIVING <br />ROOMS, DINING ROOMS, SUNROOMS, FAMILY ROOMS, <br />DENS, LIBRARIES, SLEEPING ROOMS, PARLORS AND <br />SIMILAR ROOMS OR AREAS AS SPECIFIED PER N.E.C. <br />210.12 <br />3. ANY CONFLICTS BETWEEN LOCATION OF MECHANICAL <br />FIXTURES ON PLANS AND THE ABILITY TO LOCATE THEM <br />IN THE FIELD MUST BE REPORTED TO THE ARCHITECT <br />PRIOR TO INSTALLATION. <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />METER 2/0 or 410 SE Alu <br />MAIN <br />0 <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />�— 4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to Tooter steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />DOOF <br />JAMB <br />TRIM <br />BASE <br />TRIM <br />INTERCOM SPEAKER <br />ALIGNED W/ EDGE <br />OF SWITCH <br />iQ <br />-SWITCH <br />1/2" <br />DUPLEX _ <br />OUTLET I? <br />ih <br />0 <br />0 <br />0 <br />NOTE: <br />ALL DIMENSIONS ARE FROM <br />ROUGH FRAMING <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT 1HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />® FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />�} TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />QSTRUCTURED WIRE OUTLET <br />6- SWITCH AT 36" <br />6 3 WAY SWITCH AT 36" <br />-W- 4 WAY SWITCH AT 36" <br />-p PUSH BUTTON FOR GARAGE DOOR OPENER <br />-0 DIMMER SWITCH AT 36" <br />-� PUSH-BUTTON DOORBELL <br />CLG MNT LT FIXTURE <br />-�- CLG MNT PREWIRE - FIXTURE BY OWNER <br />-ECI} SURFACE MNT FIXTURE <br />-}- WALL MNT FIXTURE <br />NOTE: <br />\O 40W A 6" ROUND OPALEX - ALTERNATE <br />TUB/SHOWER CANS MAY BE <br />4 ' 50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />APPROVED BY <br />Q RECESS CAN OR LED OWNER <br />®� 50W PAR20 NFL 4" MINI ROUND RECESS <br />50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />F�- CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />v` SMOKE DETECTOR <br />O SMOKE DETECTOR <br />=U-18= UNDER CABINET 18" <br />=S-18= SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 = UNDER CABINET 36" <br />= S-36 = SINGLE 36" FLUOR STRIP <br />D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />FF24:;? 24" VANITY LIGHTING <br />36 =­:,:4 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />® EXHAUST FAN/LIGHT <br />0 EXHAUST FAN <br />dp DOUBLE FLOOD LIGHT W/ COVERS AND <br />V 150W PAR 38 FL <br />El INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />O CEILING MNT SPEAKER <br />® CHIMES (DELETE W/ INTERCOM) <br />® MASTER STATION <br />® ELEC PANEL <br />n VACUM OUTLET AT 12" <br />L/RA CEILING RETURN AIR (W/ SIZE) <br />® A/C REGISTER <br />QT THERMOSTAT <br />® SECURITY PAD <br />ELEC METER <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE <br />USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION <br />PURPOSES. <br />(D LO ^ <br />/N� <br />o <br />W <br />L <br />C' <br />0 <br />� M <br />-> <br />N <br />} <br />V <br />M <br />�� <br />� <br />c� <br />M <br />A� <br />t o <br />V/ <br />D O <br />O U: o <br />2 o <br />Q <br />.Ns <br />W�� <br />m <br />0 <br />U <br />� N <br />N <br />W <br />-aa���m <br />L <br />O ri <br />Dui ( w0� <br />W wF-¢ w5_j xgQYzw Z <br />W W it°2_jaOa�aLLUO°_jO <br />Q U D°X�zLLLLoz2_j <br />Q F 0WHOZowooMz <br />000 wwa>6wwFFDxw<0w_j <br />LL <br />oof o = o¢QOa <br />LL a O LL <br />I <br />I <br />M, <br />r <br />O <br />U <br />M_0 <br />W <br />CM <br />O <br />J 1 <br />C <br />a <br />W <br />Q <br />z <br />z <br />a <br />J <br />LU <br />1--q <br />LL <br />(Q <br />V <br />Mo <br />W <br />M <br />N <br />O <br />O <br />N <br />Z Uj <br />OF <br />�C/)oo <br />F_ M O <br />Q w c0 � <br />J <br />W LL d" <br />Q W Q Lq <br />W 0- M <br />QQao <br />U <br />Z F— <br />W <br />_I O <br />O <br />'IT <br />LAST PLOT DATE <br />May. 24, 17 <br />1 ST & 2ND FLOOR <br />ELECTRICAL PLAN <br />A <br />z�:e <br />w (n <br />H — <br />U <br />�Q <br />wa <br />HF_ <br />�Q <br />Oz <br />=z <br />�w <br />WO <br />af <br />Z w <br />Q H <br />Z <br />�w <br />zU) <br />Q Z <br />0 <br />U <br />z <br />z <br />w <br />J <br />O <br />0 U <br />