ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />Fff <br />K51W.P, <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />7,111 DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ WALL SWITCH <br />$3 THREE-WAY SWITCH <br />?4 FOUR-WAY SWITCH <br />$R RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />P.C. <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />lO EXHAUSTFAN <br />;Q EXHAUST FAN/LIGHT COMBINATION <br />® D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />PB PUSH BUTTON SWITCH (OPTIONAL) <br />k[jBD PUSH BUTTON SWITCH - DOOR BELL <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB TELEPHONE/USB (OPTIONAL) <br />TV TELEVISION (OPTIONAL) <br />TV 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />ELECTRIC METER <br />I ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />G!�J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G ' J OPT. CEILING FAN <br />W (1) PHONE LINE, (1) DATA PORT <br />3" VTR <br />AIL <br />I <br />I <br />i <br />I <br />I I <br />I I <br />I ( <br />LAV 1\ <br />_I I <br />ti TUB/ <br />W/C SHOWER <br />LAV <br />3" <br />3" VTR <br />AIL <br />I <br />i <br />I <br />I <br />I <br />I OPT. <br />LAV <br />INi LAV <br />U W/C <br />SHOWER <br />„ � \2naF FCR <br />STU DOR <br />VENTQ � DBL SINK <br />L W/ DISP. <br />W/C <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC <br />TO BE VERIFIED WITH PLUMBER <br />LOAD CALCULATIONS <br />UNIT -A 1532 (1532) <br />SQ. FT. AT 3 WATTS / SQ. F.T. <br />1533 S.F. <br />4599 <br />SMALL APPLIANCE CIRCUITS AT 1500 WATTS <br />3 <br />4500 <br />LAUNDRY CIRCUITS AT 1500 WATTS <br />1 <br />1500 <br />SUBTOTAL: 10599 <br />DISHWASHER AT 1200 WATTS <br />1 <br />1200 <br />DISPOSAL AT 960 WATTS <br />1 <br />960 <br />WATER HEATER AT 5500 WATTS <br />1 <br />5500 <br />DRYER OUTLET AT 5000 WATTS <br />1 <br />5000 <br />AIR HANDLER UNIT AT 1200 WATTS <br />1 <br />1200 <br />RANGE AT 8000 WATTS <br />1 <br />8000 <br />MICROWAVE AT 1200 WATTS <br />1 <br />1200 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />SUBTOTAL: 23060 <br />TOTAL: 33659 <br />1st 10 KW at 100% <br />10000 <br />BALANCE OF WATTS AT 40% <br />9464 <br />AIR CONDITIONER WATTS AT 100% <br />1 <br />7104 <br />HEAT PUMP WATTS AT 100% <br />0 <br />HEAT PUMP & SUP. HEAT WATTS AT 65% <br />1 <br />1 5200 <br />TOTAL: 31768 <br />LOAD WATTS --- 240 VOLTS <br />AMPS: 133 <br />PROVIDE 150 AMP SERVICE <br />Optional Overhead Service <br />Same As Underground <br />150 Or 200 Amp Service <br />0 <br />Power Co. Feed <br />200A <br />Indoor Panel <br />Center <br />NEMA 1 <br />R MA N <br />200 AM P <br />3R <br />Cable <br />#4 Solid COPPER Ground <br />3" <br />C.O. <br />Intersystem Bonding <br />Termination Per <br />NEC 17, 250.94 5/8" Galvanized Driven Ground <br />Rods at least 6' apart <br />Typical 150-200 Amp Electrical Riser Diagram <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF <br />THE NFPA 70 - 17, LOCAL CODES AND THE LOCAL POWER CO. <br />------------------------- <br />OUTDOOR LIVING <br />INSTALL LIGHT <br />ROUGH -IN <br />FOR OPT. <br />FAN/LIGHT i WP <br />GFI <br />.n. <br />— — — —, <br />I <br />DINING <br />I KITCHEN 1 <br />GFI <br />SWITCH FOR <br />DISPOSAL IN CAB <br />UNDER SINK <br />\ <br />GREAT ROOM <br />/,,>ROUGH -IN\ <br />FOR OPT <br />I <br />1 / <br />C.M <br />j UPSTAIRS t <br />DISCONNECT <br />I <br />FOYER <br />G <br />\ <br />GFI <br />@ 44" <br />W.H. <br />A.F.F. <br />1 \ 0 <br />I I <br />DB <br />ENtRY I <br />I GARAG E <br />WP <br />LIGHT AS GFI <br />PER SPECSb <br />DB&GFI TO <br />BE ALIGNED <br />GARAGE <br />VERTICALLY <br />LIGHT AS <br />PER SPECS <br />GARAGE <br />DOOR <br />I <br />GFI <br />--------------- <br />I <br />1 <br />I <br />I � <br />I <br />I <br />bZ <br />f=a <br />I <br />I <br />LLJ <br />Q <br />U <br />I <br />00 <br />IL <br />I <br />I <br />twILL <br />o <br />W <br />irV=� <br />\ j�p=p <br />©W <br />I <br />I <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER <br />SPECS <br />1ST ELECTRICAL <br />- UNIT -A 1532 <br />SCALE: Y"=1'-0" <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />F— -- -- —1 <br />I <br />2ND ELECTRICAL - UNIT -A 1532 <br />SCALE: Y4"=1'-0" <br />ew <br />0 <br />d <br />UJ <br />o� <br />C f0 C, N <br />d <br />CL = <br />o+ c <br />E c <br />��rv0 <br />v d <br />E <br />C'7 <br />CV <br />0 <br />CV <br />2 <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions <br />of the drawing pages bearing <br />Engineer's signature and seal. <br />o Eoo <br />8 N <br />W7 <br />0 <br />u7 00 N u- <br />M <br />H <br />fn r n � - u, L1! <br />co v a c- <br />Q <br />w <br />C J a- Y V." <br />LL <br />co LL Z <br />Z <br />_ V 0 0 <br />M� <br />Y <br />fON � m Lij Q <br />i <br />og�� ¢ M <br />Wrn <br />J Z <br />ILW <br />O <br />Z <br />N C.O. U <br />L) <br />Z <br />000 <br />W <br />V M <br />Z N M <br />o g <br />z <br />z <br />J <br />C1. N <br />W <br />N <br />' <br />z <br />C <br />uJ <br />J <br />2 <br />L` <br />4 <br />fC5 <br />cry <br />2 <br />w26 <br />o� <br />N <br />U. <br />UWA <br />itS <br />w <br />®® <br />c � <br />Q <br />o <br />�W <br />M <br />J <br />a � <br />Z <br />ri E <br />cd <br />C>- 0 <br />E v <br />Zo <br />O <br />o <br />z <br />}N <br />Q N <br />Z <br />oa <br />F� r6S <br />:z a <br />00 <br />O E <br />a Q <br />Cc)C� Z <br />a��i ru <br />wa <br />ww <br />�J <br />no <br />Cn C <br />�om� <br />q <br />o�Z <br />o¢ <br />ZM= <br />m J <br />agz <br />o p <br />z 0 <br />a <br />W <br />CD S <br />a 3 <br />w <br />n w <br />a= <br />J <br />� <br />o <br />v <br /><a <br />0Ia <br />;0 <br />° 3 <br />0 O <br />in <br />> 00 <br />T <br />U <br />M <br />rn <br />@ <br />0 <br />O <br />� <br />H <br />M <br />co <br />LL <br />r <br />In <br />T <br />=3N <br />E <br />014 <br />T <br />Cr V <br />O <br />W <br />(0 <br />U <br />O <br />00 <br />m <br />00co <br />CV <br />00 <br />C"i <br />Q <br />CD <br />lin <br />c'M <br />N <br />N <br />N <br />Cu.-,) <br />LO <br />CO <br />r <br />M r <br />r <br />o <br />co <br />o <br />Z <br />M <br />Z <br />E 0 <br />N <br />m <br />a. <br />E <br />0 <br />o <br />JOB <br />NO: 23-05735-05740 <br />SCALE: <br />AS NOTED <br />SHEET NO, <br />■ <br />