340-MADISON IV CMU
<br />Garage Right - Elevation -I3
<br />SBUT MEX
<br />NUMBER:
<br />5HEE7 NAME:
<br />NUMBER:
<br />SHEET NAME:
<br />CS
<br />COVER SHEET
<br />CS-3
<br />SCUARE FOOTAGE CALCULATIONS
<br />E-I.0
<br />ELECTRICAL PLANS - FIRST FLOOR
<br />F-10
<br />FOUNDATION - SLAB PLAN
<br />E-22
<br />ELECTRICAL PLANS - SECOND FLOOR
<br />A-I.0
<br />FIRST FLOOR PLAN
<br />A-32
<br />MISC DETAILS
<br />A-2.0
<br />SECOND FLOOR PLAN
<br />A-33
<br />MISC DETAILS
<br />A-3.4
<br />MISC DETAILS
<br />A-320
<br />FRONT/REAR ELEVATIONS I OPTION 3/ROOF PLAN
<br />A-321
<br />SIDE ELEVATIONS I OPTION 3
<br />A-40
<br />BUILDING SECTIONS
<br />ENE%Y REQUIREMENT SCHEDULE
<br />EXTERIOR WALLS (FRATE)
<br />R-13
<br />EXTERIOR WALLS (BLOCK)
<br />41 FOIL
<br />ATTIC CEILRIG
<br />R-30
<br />GENERAL NOTES
<br />THE STANDARD GENERAL SPECIFICATIONS FOR AMERICAN HOMES 4 RENT 4 AMH
<br />DEVELOPMENT SHALL GOVERN EXCEPT AS MODIFIED r SUPPLEMENTED BY THESE
<br />WINDOW INSTALLATION:
<br />PLANS.
<br />1. WNDOW9 SHALL BE INSTALLED AND FLASHED IN ACCORDANCE WI7W THE
<br />MANUFACTURERS WRITTEN INSTALLATION INSTRUCTIONS. WRITTEN INSTALLATION
<br />3. DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS
<br />THESE PLANS HAVE BEEN DESIGNED TO MEET THE REQUIREMENTS OF:
<br />INSTRUCTIONS SHALL BE PROVIDED BY THE MANUFACTURER FOR EACH WINDOW.
<br />SEPARATING THE DLELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MIN.
<br />2023 FLOE IDA BUILDING CODE, (RESIDENTIAL, STH EDITION
<br />-26 GAUGE (0.40 —) SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL
<br />OCCUPANCY: SINGLE FAMILY RESIDENTIAL
<br />FLOOD ZONE REQUIREMENTS:
<br />HAVE NO OPENINGS INTO THE GARAGE.
<br />I. PLAN MEETS OR EXCEEDS FEMA FLOOD FINISHED GARAGE FLOOR ELEVATION.
<br />GEILINY CONSTRUCTION:
<br />4. FOUNDATIONS AND SUPPORTS FOR OUTDOOR MECHANICAL SYSTEMS SHALL BE
<br />I. THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC AREA
<br />BATH AREAS:
<br />INSTALLED ABOVE THE BASE FLOOD ELEVATION AND SHALL ALSO CONFOp"I TO THE
<br />BY NOT LESS THAN 1/2 INCH (12.1 —) GYPSUM BOARD APPLIED EDT THE GARAGE
<br />I. IN97ALL 2x4 BLOCKING TOILET PAPER AND TOLLEL BAR LOCATIONS, SEE
<br />MANUFACTURER'S N9TALLATION INSTRUCTIONS.
<br />SIDE. GARAGES BENEATH WABITABLE ROOMS SHALL BE SEPARATED FROM ALL
<br />DETAILS.
<br />WABITABLE ROOMS ABOVE BY NOT LESS THAN 5/8 INCH (59 mm) TYPE "X" GYPSUM
<br />5. AUXILIARY DRAM PAN. CATEGORY Iv CONDENSING APPLIANCES SHALL BE
<br />BOARD OR EQUIVALENT. WHERE THE SEPARATION 19 A FLOOR -CEILING ASSEMBLY,
<br />KITCWENS:
<br />PROVIDED WITH AN AUXILIARY DRAIN PAN WHERE DAMAGE TO ANY BUILDNG
<br />THE STRUCTURE SUPPORTING THE SEPARATION SHALL AL50 BE PROTECTED BY NOT
<br />I. INSTALL 2X6 BLOCKING AT 89" AFF, ON CENTER FOR UPPER CABINET
<br />COMPONENT WILL OCCUR AS A RESULT OF STOPPAGE N THE CONDENSATE DRAIN
<br />LESS THAN 1/2 INCH (121 —) GYP5Ul-1 BOARD OR EQUIVALENT.
<br />INSTALLATION.
<br />PIPING SYSTEM. 7HE5E PANS SHALL BE INSTALLED IN ACCORDANCE WITH THE
<br />APPLICABLE PROVISIONS OF SECTIONS M14113.
<br />EXTERIOR FINISHES:
<br />TUB AND SHOLLER ARE45:
<br />THICKNESS OF TENURED FIN15W OVER FRAME APPLICATION SHALL BE PER THE
<br />I. CEMENT, FIBER -CEMENT, OR GLASS MAT GYPSUM BOARD (NO GREEN BOARD
<br />EXHAUST FANS AND VENTING:
<br />CURRENT APPROVED BUILDING CODE AND ASTM C526. INSTALLATION OF EXTERIOR
<br />ALLOWED) N COMPLIANCE WITH ASTM C12BB, C1325, OR CIi18 ,AND INSTALLED WITH '8
<br />I. OUTDOOR 0151 THE AIR REMOVED BY EVERY MECHANICAL EXHAUST
<br />LATWING AND FRAMING APPLICATION REQUIREMENTS TO BE PER THE CURRENT
<br />x I-I/IA" DAGGERZ PHILIPS WAFER HEAD CEMENT BOARD SELF DRILL SCREWS W/
<br />SYSTEM SHALL BE DISCHARGED TO THE OUTDOORS. AIR SHALL NOT BE EXHAUSTED
<br />APPROVED BUILDING CODE AND ASTM C 1063.
<br />COATING SHALL BE USED A9 BACKERS FOR WALL TILE IN TUB AND SHOWER AREAS,
<br />INTO AN ATTIC, SOFFIT, RIDGE VENT OR CRAWL SPACE.
<br />AND WALL PANELS IN SHOVER AREAS.
<br />EGRESS:
<br />2, EXHAUST AIR FROM ATH AN TOILET ROOMS 9H NOT
<br />B ROOMS D O LE ALL O BE
<br />I. EACH BEDROOM MUST WAVE ONE WINDOW THAT COMPLIES WITH EGRESS CODES, IF
<br />TERMITE TREATMENT:
<br />RECIRCULATED WITHIN A RESIDENCE OR TO ANOTHER DWELLING UNIT AND SHALL BE
<br />THERE IS NO ACCESS TO EXTERIOR THROUGH A DOOR THE WINDOW MUST WAVE A
<br />TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES,
<br />EXHAUSTED DIRECTLY TO THE OUTDOORS. EXHAUST AIR FROM BATHROOMS AND
<br />MAXIMUM OPENING HEIGHT OF 44' ABOVE FINISH FLOOR LINE OF THAT PARTICULAR
<br />INCLUDING SOIL APPLIED PESTICIDES, BAITING 5YBTEMS, AND PESTICIDES APPLIED
<br />TOILET ROOMS SHALL NOT DISCHARGE INTO AN ATTIC, CRAWL SPACE, OR OTHER
<br />ROOM.
<br />70 WOOD, OR OTHER APPROVED METHODS OF TERMITE PROTECTION LABELED FOR
<br />AREAS INSIDE THE BUILDING.
<br />U5E AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION, UPON COMPLETION OF
<br />2. IN DWELLING UNITS (WERE THE OPENING OF AN OPERABLE WINDOW IS LOCATED
<br />THE APPLICATION OF THE TERMITE PROTECTIVE TREATMENT, A CERTIFICATE OF
<br />3. DUCT LENGTH. THE MAXIMUM ALLOWABLE EXHAUST DUCT LENGTH SHALL BE
<br />MORE THAN 12 INCHES ABOVE THE FINISHED GRADE OR SURFACE BELOW, THE
<br />COMPLIANCE SHALL BE 156UED 70 THE BUILDING DEPARTMENT BY THE LICENSED
<br />DETERMINED BY ONE OF THE METHODS SPECIFIED N SECTIONS M1502 a51 THROUGH
<br />LOWEST PART OF THE CLEAR OPENING OF THE WINDOW SHALL BE A MINIMUM OF 24
<br />PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: "THE
<br />M502.453. THE MAXIMUM LENGTH OF THE EXHAUST DUCT SHALL BE 35 FEET FROM
<br />INCHES ABOVE THE FIN1544ED FLOOR OPERABLE SECTIONS OF: WINDOWS SHALL NOT
<br />BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF
<br />THE CONNECTION TO THE TRANSITION DUCT FROM THE DRYER TO THE OUTLET
<br />PERMIT OPENINGS, THAT ALLOW PASSAGE OF A 4" SPHERE LLHERE SUCW OPENINGS
<br />SUBTERRANEAN TERMITES. TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS
<br />TERMINAL, THE MAXIMUM LENGTH OF THE DUCT SHALL BE REDUCED 25 FEET (162 mm)
<br />ARE LOCATED WITHIN 24 INCHES OF THE FINISHED FLOOR PER THE CURRENT
<br />ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER
<br />FOR EACH 45 DEGREE (0.19 RAD) BEND AND 5 FEET (1524 —n FOR EACH 90
<br />APPROVED BUILDING CODE.
<br />SERVICES."
<br />DEGREE (lb RAO) BEND. THE MAXIMUM LENGTH OF THE EXHAUST DUCT DOES N07
<br />INCLUDE THE TRANSITION DUCT. EXCEPTION - WHERE A CLOTHES DRYER BOOSTER
<br />FLASHING:
<br />MECHANICAL AND HVAC:
<br />FAN 15 INSTALLED AND LISTED AND LABELED FOR THE APPLICATION, THE MAXIMUM
<br />I. FLASHNG SHALL BE INSTALLED AT WALL AND ROOF INTERSECTIONS, DECK AND
<br />I. ENERGY CALCULATIONS FOR HEATING AND COOLING CAPACITIES 5WALL BE
<br />LENGTH OF THE EXHAUST DUCT, NCLUDINIG ANY TRANSITION DUCT, SHALL BE
<br />WALL INTERSECTIONS, AT GUTTERS. AT ALL CHANGES IN ROOF SLOPE OR DIRECTION,
<br />FURNISHED BY THE MECHANICAL ENGINEER AS AN ATTACHMENT TO THIS PLAN SET
<br />PERMITTED TO BE IN ACCORDANCE WITH THE BOOSTER FAN MANUFACTURER'S
<br />AND AROUND ROOF OPENNb5,
<br />AT THE TIME OF APPLICATION FOR PERMIT.
<br />INSTALLATION INSTRUCTIONS. WHERE A CLOTHES DRYER BOOSTER FAN 15 INSTALLED
<br />AND NOT READILY ACCESSIBLE FROM THE ROOM IN WHICH THE DRYER 15 LOCATED,
<br />2. APPROVED CORROSION -RESISTANT FLASHING SHALL BE APPLIED SHINGLE
<br />2. MECHANICAL APPLIANCES SHALL BE ACCESSIBLE FOR INSPECTION, SERVICE,
<br />A PERMANENT IDENTIFYING LABEL SHALL BE PLACED ADJACENT TO W-IERE THE
<br />FASHION N SUCH A MANNER AS TO PREVENT ENTRY OF WATER INTO THE WALL
<br />REPAIR, AND REPLACEMENT WITHOUT REMOVING PERMANENT CONSTRUCTION, OTHER
<br />EXHAUST DUCT ENTERS THE WALL. THE LABEL SHALL BEAR TWE WORDS "THIS DRYER
<br />CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING
<br />APPLIANCES, OR ANY OTHER PIPING OR DUCTS NOT CONNECTED TO THE APPLIANCE
<br />EXHAUST SYSTEM 15 EQUIPPED WITH A REMOTELY LOCATED BOOSTER FAN."
<br />COMPONENTS. THE FLASHING 544ALL EXTEND TO THE SURFACE OF 744E EXTERIOR
<br />BEING INSPECTED, SERVICED, REPAIRED, OR REPLACED. A LEVEL WORKING SPACE
<br />WALL FINISH. APPROVED CORROSION -RESISTANT FLASHING SHALL BE INSTALLED AT
<br />AT LEAST 30 INCHES (162 —) DEEP AND 30 INCHES (162 —) WIDE 544ALL BE
<br />4. PROVIDE BACK DRAFT DAMPERS A7 INTAKE AND EXHAUST LOCATIONS AS
<br />ALL REQUIRED LOCATIONS PER THE CURRENT APPROVED BUILDING CODE.
<br />PROVIDED IN FRONT OF THE CONTROL SIDE TO SERVICE AN APPLIANCE.
<br />REQUIRED BY THE CURRENT APPROVED BUILDING CODE.
<br />ISSUED: 1 /8/2024
<br />VERSION: 5.0
<br />SQUARE FOOTAGE
<br />ALL WORK SHALL CCMPL'r WITH PREVAILING
<br />CODES FLORIDA BUILDING CODE.
<br />NATIONAL ELECTRIC CODE,
<br />AND THE CITY OF ZEPHYRHILLS
<br />ORDINANC-FS
<br />R�-1t�
<br />,7
<br />C, �Y�41�����R
<br />AFAR A88ET MANA�if 80. FT.
<br />HEATED AREA
<br />Sq. Ft
<br />MAIN LEVEL
<br />843
<br />SECOND LEVEL
<br />1134
<br />TOTAL MIIR80 Ff.(SYhC�wq
<br />IonMETHODOLOGY,
<br />ANSI Z1962009
<br />The total area ealeulated from the outside-toaNeida of fuming. Yxijdig opUorul Rrlished baement options a
<br />shown. The meaxduda atanvel at Hghest b.el above grade, garage, covered paEo/pardros.
<br />M
<br />M
<br />H
<br />O�
<br />�
<br />�
<br />Q
<br />O��
<br />�
<br />U
<br />C
<br />x
<br />wyx
<br />W
<br />O
<br />0
<br />A
<br />L_ J
<br />VERSION: 5.0
<br />R!!
<br />COVE11SHEET
<br />R!1