Search
37691 Dusty Saddle Ln
Zephyrhills
>
Building Department
>
Building Plans
>
37691 Dusty Saddle Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 8:33:22 PM
Creation date
2/19/2025 8:42:57 AM
Metadata
Fields
Template:
Building Plans
Street #
37691
Location
Dusty Saddle Ln
Contractor
AMH NB Dev FL
Building Plans - Permit #
8147
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL LEGEND <br />--+GA9 <br />GAS LIE <br />RECESSED CAN <br />LIGHT <br />Oy <br />COLD WATER <br />[} <br />FLU54 MOUNT LED <br />0 <br />ELECTRICAL PANEL <br />Q <br />WALL MOUNTED LIGHT <br />ELECTRICAL METER <br />WALL SCONCE <br />d' <br />DISCONNECT SWITCH <br />FLUORESCENT LIGHT <br />di BULB <br />$ <br />50TCW <br />O <br />FLUORESCENT LGHT <br />R/ 2 BULBS <br />$r <br />3-WAY 5WTCH <br />® <br />VAPOR PROTECTED <br />LIGHT <br />4 <br />$ <br />4-WAY SWITCH <br />C <br />EXHAUST FAN <br />$ <br />DMTMER SWITCH <br />EXHAUSTLIG FAN W/ <br />LIGHT <br />4 <br />BUTTON <br />EXHAUST FAN R/ <br />EAT 4 LIGHT <br />6 <br />DUPLEX OUTLET <br />c <br />SMOKE DETECTOR <br />0 <br />QUADPLEX OUTLET <br />® <br />CARBON OXIDE <br />DETECM <br />m <br />SWITCHED DUPLEX <br />1 <br />THERMOSTAT <br />CUTLET <br />F- <br />FLOOR OUTLET <br />DIRECT LURE <br />C-FI <br />GFI OUTLET <br />T <br />PHONE JACK <br />v �Grl <br />WATER PROOF GFI <br />LU <br />OUTLET <br />T <br />MEDIA JACK <br />c� G <br />CEILING MOUNTED <br />(nip <br />0 <br />OUTLET <br />Y <br />CABLE Tv OUTLET <br />220v <br />® <br />220V OUTLET <br />DOOR CHIMES <br />CEILING MONIED <br />® <br />SECURITY PANEL <br />4 <br />LIGHT <br />HANGING CEILING <br />FLOOD LIGHT <br />MOUNTED LIGHT <br />n <br />n <br />C-#_'D <br />CEILING FAN <br />r--D <br />CEILING FAN w/LIGHT <br />u <br />u <br />ELECTRICAL GENERAL NOTE5 <br />SWITCHES TO BE 45' AFF. <br />RECEPTS TO BE 12' AFF. - 42" F OVER A COUNTER <br />ALL WRING TO BE N ACCORDANCE WITH NEC <br />ARC FAULT CIRCUIT INTERRUPTER PROTECTION SHALL BE PROVIDED AS REQUIRED <br />N NEC 210.12(A) ARID SHALL BE INSTALLED IN A READILY ACCESSIBLE LOCATION. <br />ALL SMOKE DETECTORS SHALL BE HARDWIRED INTO AN ELECTRICAL P'OLER <br />SOURCE AND SHALL BE EQUIPPED WITH A MONITORED BATTERY BACKUP. PROVIDE <br />AND INSTALL LOCALLY CERTIFIED 91OKE DETECTORS. <br />GROUND FAULT CIRCUIT INTERRUPTER SHALL BE PROVIDED AS REQUIRED N NEC <br />2108(A) MID INSTALLED IN A READILY ACCESSIBLE LOCATION <br />IT IS THE RESPONSIBILITY OF THE LICENSED ELECTRICIAN TO N5URE THAT ALL <br />ELECTRICAL WOW IS N FULL COMIPLIANCE WITH NFPA ICA - NEC AND ALL <br />APPLICABLE LOCAL STANDARDS, CODES. AND ORDINANCES. <br />PROVIDE INTERSYSTEM BONDING TREMINATION AT SERVICE LOCATION PER NEC <br />25054 <br />LL91NIAIRES N CLOTHES CLOSETS SHALL BE INSTALLED PER THE PROVISIONS OF <br />NEC 410.16l AU A (B) <br />RECESSED LIGHTING TO BE AIR TIGHT AND IC RATED <br />003 OF THE LAf1P5 N PERMANENTLY INSTALLED FIXTURES SHALL BE <br />HIGH -EFFICIENCY LAMPS <br />REFER TO ENERGY CALCULATIONS FOR ADDITIONAL INFORMATION, <br />PROVIDE THE REQUIRED CLEARANCES AROUND PANELS AND DISCONNECTS IN <br />COMPLIANCE WITH NEC 11015. <br />ALL RECEPTACLES SHALL BE TAMPER RESISTANT PER NEC 40612. <br />THE BRANCH CIFICUIT SUPPLYING THE RECEPTACLE(S) IN A GARAGE SHALL NOT <br />SUPPLY OUTLETS OUTSIDE O THE GARAGE AND NOT LE55 THAN ONE RECEPTACLE <br />OUTLET SHALL BE INSTALLED FOR EACH MOTOR VEHICLE SPACE. <br />AFO PROTECTION - 21032 (B) DLLELLNG UNITS. ALL 20 VOLT. SINGLE PHASE. 5 MID <br />20 AMP BRANCH CIRCUITS 5UPPLTNG OUTLETS INSTALLED IN DWELLNG UNI75 <br />FAMILY ROOMS, DINING ROOMS. LIVING ROOMS, PARLORS. LIBRARIES. DENS, <br />BEDROOM 5UNR0OMIS. RECREATION ROOKS. CLOSETS, HALLWAYS, OR SIMILAR <br />ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED AFCI. CO'1BNATION TYPE. <br />INSTALLED TO PROVIDE PROTECTICN OF BRANCH CIRCUIT. <br />EXTERIOR GARAGE <br />200 AMP METER MAN COMBO <br />00 AMP MAN <br />LLG INTERIOR <br />PANEL <br />II I <br />II I <br />I I I <br />I I I <br />II I <br />G 4C AL 5ER CABLE <br />A/C <br />DISCONNECT H�dGFI <br />GROUNDING ELECTRODE w 6FiLi <br />SHALL COMPLY WITH <br />SEC 25052 <br />s <br />ELECTRICAL RISER DIAGRAM <br />N T.S. <br />4'-3%' <br />/ 24- GFI_ <br />io I I vkl€ <br />II I <br />I I G11€ <br />- <br />Ili _ <br />-� I.x <br />1 24- GFI <br />7 <br />OD Y 9F€ <br />T2^ Tl" <br />2. - O <br />�l <br />I <br />_`_-- <br />OPT_DE ATED 50 <br />AMPS (14 - N8'1A 24 D GR p <br />�F FiEQU1RED By CODE 22G, _ .-.-.-...-.: <br />A <br />ce C-+ m uTv <br />ELEC METER <br />(LOCATION BYI <br />BUILDER)F - - - - - <br />I e I <br />W L---------I --- ---� <br />HIS <br />FIRST FLOOR ELECTRICAL PLAN - ELEVATION'J' <br />1101m iIM1"o" <br />STRUCTURED <br />MEDIA CABINET TO <br />INCLUDE CATS* <br />WAX, USB WFI <br />ROUTER SPACE <br />AND POWER <br />VERIFY EXACT <br />REWAffMENT, <br />LOCATION AND <br />MOUNTING HEIGHT <br />PRICK TO <br />INSTALLATION <br />4W " DEYELOF'ENT <br />W T SCALE TIESE 0R40" <br />'RFY BNLDF4'i OREWATIpI WITH <br />CONTRACTOR AND STTE PLANE <br />BEFORE CONSTRUCTION THESE <br />DRAO" DO NOT CONMAN <br />SKCFIC KORMATION FOR dNT <br />STRYTRAL E XIW$ (TO BE <br />PRV✓DED BY ENHffR OF <br />RECORD) ANT DBCREPANCY <br />(DPO606. OIRE TATIONI, ETCI <br />BETWMN TRESE DRAAWA AND THE <br />ASSOCIATED DRALW S wa Sm <br />SWLLL BE PEPORTED TO <br />CLNTR/LTCR AT ONCE AND NU <br />CONSTRUCTION SHALL FFDCEE0 <br />IML COWCTED. TIE <br />CONTRACTOR ASBFES TIE <br />RESPONUMIn' TO FEET ALL <br />REOUIEFEWS OF LOCAL ISJRDNG <br />OFFICIALS R TO CONRT WITH STATE <br />NXI)m CODES <br />0 <br />J � <br />o Z M <br />w <br />4 O 0 <br />F-- <br />W <br />Q � a <br />U <br />Q <br />x Q° <br />r <br />111101EVE I 4WR <br />N <br />M <br />O <br />7V a <br />z �rr <br />0'-4 wV <br />V/ <br />O �L <br />ZM <br />UUga <br />N W 0 <br />a O <br />H s� <br />J <br />H � YE., 0 a:O [i <br />ry co;_ <br />'Da <br />to In N <br />I <br />L <br />OIEEIFE RE <br />VERSION: 5.0 <br />gELE <br />ELECTRICAL PLANS <br />I <br />FIRST FLOOR <br />NEaTN <br />E-1.0 J <br />