My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
37703 Dusty Saddle Ln
Zephyrhills
>
Building Department
>
Building Plans
>
37703 Dusty Saddle Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 10:27:57 AM
Creation date
2/19/2025 8:43:47 AM
Metadata
Fields
Template:
Building Plans
Street #
37703
Location
Dusty Saddle Ln
Contractor
AMH NB Development FL LLC
Building Plans - Permit #
8075
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
660 - FILLMORE <br />Garage Right - Elevation - K3 <br />SHEETINDEX <br />NUMBER: <br />SHEET NAME: <br />NUMBER: <br />SHEET NAME: <br />C5 <br />COVER SHEET <br />C5-3 <br />SQUARE FOOTAGE CALCULATIONS <br />E-I.0 <br />ELECTRICAL PLANS - FIRST FLOOR <br />F-IID <br />FOUNDATION - SLAB PLAN <br />A-32 <br />M15C DETAILS <br />A-3.4 <br />MISC DETAILS <br />A-IID <br />FIRST FLOOR PLAN <br />A-330 <br />FRONT/REAR ELEVATIONS K/ROOF PLAN <br />A-331 <br />SIDE ELEVATIONS K <br />GENERAL NOTES <br />THE STANDARD GENERAL SPECIFICATIONS FOR AMERICAN HOMES 4 RENT I AMH <br />DEVELOPMENT SHALL GOVERN EXCEPT AS MODIFIED s SUPPLEMENTED BY THESE <br />PLANS. <br />THESE PLANS HAVE BEEN DESIGNED TO MEET THE REQUIREMENTS OF: <br />2023 FLORIDA BUILDING CODE, RESIDENTIAL, BTH EDITION <br />OCCUPANCY: SINGLE FAMILY RESIDENTIAL <br />CEIL hJGa CONSTRUCTION: <br />I. THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS AT71C AREA <br />BY NOT LE55 THAN 1/2 INCH (121 —) GYPSUM BOARD APPLIED TO THE GARAGE <br />SIDE. GARAGES BENEATH HABITABLE ROOMS SHALL BE SEPARATED FROM ALL <br />HABITABLE ROOMS ABOVE BY NOT LESS THAN 5/8 INCH (I5:3 mm) TYPE "X" GYPSUM <br />BOARD OR EQUIVALENT. WHERE THE SEPARATION IS A FLOOR -CEILING ASSEMBLY, <br />THE STRUCTURE SUPPORTING THE SEPARATION SHALL ALSO BE PROTECTED BY NOT <br />LESS THAN 1/2 INCH (121 —) GYPSUM BOARD OR EQUIVALENT. <br />EX <br />TERIOR FINISHES: <br />THICKNESS OF TEXTURED FINISH OVER FRAME APPLICATION SHALL BE PER THE <br />CURRENT APPROVED BUILDING CODE AND ASTM CS26. INSTALLATION OF EXTERIOR <br />LATHING AND FRAMING APPLICATION REQUIREMENTS TO BE PER THE CURRENT <br />APPROVED BUILDING CODE AND A57M C 1063, <br />EGRESS. <br />I. EACH BEDROOM MUST HAVE ONE WINDOW THAT COMPLIES WITH EGRESS CODES, IF <br />THERE 15 NO ACCESS TO EXTERIOR THROUGH A DOOR THE WINDOW MUST HAVE A <br />MAXMU-I OPENING HEIGHT OF 44" ABOVE FINISH FLOOR LINE OF THAT PARTICULAR <br />ROOM. <br />2. IN DWELLING UNITS WHERE THE OPENING OF AN OPERABLE WINDOW 15 LOCATED <br />MORE THAN 12 INCHES ABOVE THE FINISHED GRADE OR SURFACE BELOW, THE <br />LOWEST PART OF THE CLEAR OPENING OF THE WINDOW SHALL BE A MNIMUM OF 24 <br />NCHES ABOVE THE FINISHED FLOOR OPERABLE SECTIONS OF WINDOWS SHALL NOT <br />PERMIT OPENINGS THAT ALLOW PASSAGE OF A 4" SPHERE WHERE SUCH OPENINGS <br />ARE LOCATED WITHIN 24 INCHES OF THE FINISHED FLOOR PER THE CURRENT <br />APPROVED BUILDING CODE <br />FLASHING: <br />1. FLASHING SHALL BE INSTALLED AT WALL AND ROOF INTERSECTIONS, DECK AND <br />WALL INTERSECTIONS, AT GUTTERS, AT ALL CHANGES IN ROOF SLOPE OR DIRECTION, <br />AND AROUND ROOF OPENINGS, <br />2. APPROVED CORROSION. RESISTANT FLASHING SHALL BE APPLIED SHINGLE <br />FASHION N SUCH A MANNER AS TO PREVENT ENTRY OF WATER INTO THE WALL <br />CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRA-IING <br />COMPONENTS. THE FLASHING SHALL EXTEND TO THE SURFACE OF THE EXTERIOR <br />WALL FINISH. APPROVED CORROSION -RESISTANT FLASHING SHALL BE INSTALLED AT <br />ALL REQUIRED LOCATIONS PER THE CURRENT APPROVED BUILDING CODE. <br />WNDOW INSTALLATION: <br />I. WINDOWS SHALL BE INSTALLED AND FLASHED IN ACCORDANCE WITH THE <br />MANUFACTURERS WRITTEN INSTALLATION INSTRUCTIONS. WRITTEN INSTALLATION <br />INSTRUCTIONS 544ALL BE PROVIDED BY THE MANUFACTURER FOR EACH WINDOW <br />FLOOD ZONE REQUIREMENTS: <br />I. PLAN MEETS OR EXCEEDS FEMA FLOOD FINISHED GARAGE FLOOR ELEVATION <br />BATH AREAS: <br />I. INSTALL 2.4 BLOCKING AT TOILET PAPER AND TOWEL BAR LOCATIONS, SEE <br />DETAILS. <br />KITCHENS: <br />I. INSTALL 2X6 BLOCKING AT Se" AFF, ON CENTER FOR UPPER CABINET <br />INSTALLATION. <br />TUB AND SHOIl1ER AREAS: <br />I. CEMENT, FIBER -CEMENT, OR GLASS MAT GYPSUM BOARD (NO GREEN BOARD <br />ALLOWED) IN COMPLIANCE WITH ASTM C1288, CI325, OR CIITS AND INSTALLED WITH -8 <br />x I-IA4" DAGGERZ PHILIPS WAFER HEAD CEMENT BOARD SELF DRILL SCREWS W/ <br />COATING SHALL BE USED AS BACKERS FOR WALL TILE IN TUB AND SHOWER AREAS, <br />AND WALL PANELS IN SHOWER AREAS. <br />TERMITE TREATMENT: <br />TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, <br />INCLUDING SOIL APPLIED PE5TICIDE5, BAITING SYSTEMS, AND PESTICIDES APPLIED <br />TO WOOD, OR OTHER APPROVED METHODS OF TERMITE PROTECTION LABELED FOR <br />USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. UPON COMPLETION OF <br />THE APPLICATION OF THE TERMITE PROTECTIVE TREATMENT, A CERTIFICATE OF <br />COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED <br />PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: 'THE <br />BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF <br />SUBTERRANEAN TERMITES, TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS <br />ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER <br />SERVICES." <br />MECHANICAL AND HI <br />I. ENERGY CALCULATIONS FOR HEATING AND COOLING CAPACITIES SHALL BE <br />FURNISHED BY THE MECHANICAL ENGINEER AS AN ATTACHMENT TO THIS PLAN SET <br />AT THE TIME OF APPLICATION FOR PERMIT. <br />2. MECHANICAL APPLIANCES SHALL BE ACCESSIBLE FOR INSPECTION, SERVICE, <br />REPAIR, AND REPLACEMENT WITHOUT REMOVING PERMANENT CONSTRUCTION, OTHER <br />APPLIANCES, OR ANY OTHER PIPING OR DIUCT5 NOT CONNECTED TO THE APPLIANCE <br />BEING INSPECTED, SERVICED, REPAIRED, OR REPLACED. A LEVEL WORKING SPACE <br />AT LEAST 30 INCHES (162 —) DEEP AND 30 INCHES (162 —) WIDE SHALL BE <br />PROVIDED IN FRONT OF THE CONTROL SIDE 70 SERVICE AN APPLIANCE. <br />ENERGY REQUIREMENT SCHEDULE <br />EXTERIOR WALLS (FRN'E) <br />R.13 <br />EXTERIOR WALLS (BLOCK) <br />4.1 FOIL <br />ATTIC CEILRG <br />R-30 <br />3. DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS <br />SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MIN <br />-26 GAUGE (0.48 —) SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL <br />HAVE NO OPENINGS INTO THE GARAGE. <br />4. FOU NDATION$ AND SUPPORTS FOR OUTDOOR MECHANICAL SYSTEMS SHALL BE <br />INSTALLED ABOVE THE BASE FLOOD ELEVATION AND SHALL ALSO CONFORI.1 TO THE <br />MANUFACTURER'S INSTALLATION INSTRUCTIONS. <br />5. AUXILIARY DRAIN PAN, CATEGORY IV CONDENSING APPLIANCES 5HALL BE <br />PROVIDED WITH AN AUXILIARY DRAIN PAN WHEN DAMAGE TO ANY BUILDING <br />COMPONENT WILL OCCUR AS A RESULT OF STOPPAGE N THE CONDENSATE DRAIN <br />PIPING SYSTEM. THESE PANS SHALL BE INSTALLED IN ACCORDANCE WITH THE <br />APPLICABLE PROVISIONS OF SECTIONS M14113. <br />EXHAUST FANS AND VENTING: <br />I. OUTDOOR DISCHARGE. THE AIR REMOVED BY EVERY MECHANICAL EXHAUST <br />SYSTEM SHALL BE DISCHARGED TO THE OUTDOORS. AIR SHALL NOT BE EXHAUSTED <br />INTO AN ATTIC, SOFFIT, RIDGE VENT OR CRAWL SPACE. <br />2. EXHAUST AIR FROM BATH ROOMS AND TOILET ROOMS SHALL NOT BE <br />RECIRCULATED WITHIN A RESIDENCE OR TO ANOTHER DWELLING WIT AND SHALL BE <br />EXHAUSTED DIRECTLY TO THE OUTDOORS. EXHAUST AIR FROM BATHROOMS AND <br />TOILET ROOMS SHALL NOT DISCHARGE INTO AN ATTIC, CRAWL SPACE, OR OTHER <br />AREAS INSIDE THE BUILDING. <br />3. DUCT LENGTH. THE MAXIMUM ALLOWABLE EXHAUST DUCT LENGTH SHALL BE <br />DETERMINED BY ONE OF THE METHODS SPECIFIED IN SECTIONS 1150245.1 THROUGH <br />11502453. THE MAXIMUM LENGTH OF THE EXHAUST DUCT SHALL BE 35 FEET FROM <br />THE CONNECTION TO THE TRANSITION DUCT FROM THE DRYER TO THE OUTLET <br />TERMINAL. THE MAXIMUM LENGTH OF THE DUCT SHALL BE REDUCED 25 FEET (162 mm) <br />FOR EACH 45 DEGREE (0.19 RAD) BEND AND 5 FEET (1524 mm) FOR EACH W <br />DEGREE (lb RAO) BEND. THE MAXIMUM LENGTH OF THE EXHAUST DUCT DOES NOT <br />INCLUDE THE TRANSITION DUCT. EXCEPTION - WHERE A CLOTHES DRYER BOOSTER <br />FAN IS INSTALLED AND LISTED AND LABELED FOR THE APPLICATION, THE MAXIMUM <br />LENGTH OF THE EXHAUST DUCT, INCLUDING ANY TRANSITION DUCT, SHALL BE <br />PERMITTED TO BE IN ACCORDANCE WITH THE BOOSTER FAN MANUFACTURER'S <br />INSTALLATION INSTRUCTIONS. WHERE A CLOTHES DRYER BOOSTER FAN 15 INSTALLED <br />AND NOT READILY ACCESSIBLE FROM THE ROOM IN WHICH THE DRYER 15 LOCATED, <br />A PERMANENT IDENTIFYING LABEL SHALL BE PLACED ADJACENT TO WHERE THE <br />EXHAUST DUCT ENTERS THE WALL. THE LABEL SHALL BEAR THE WORDS "THIS DRYER <br />EXHAUST SYSTEM 15 EQUIPPED WITH A REMOTELY LOCATED BOOSTER FAN." <br />4. PROVIDE BACK DRAFT DAMPERS AT INTAKE AND EXHAUST LOCATIONS AS <br />REQUIRED BY THE CURRENT APPROVED BUILDING CODE. <br />ISSUED: 02/ 12/2024 <br />VERSION: 5.0 <br />SQUARE FOOTAGE <br />MMR AMT MANAdEMBif SO FT. <br />HEATED AREA <br />Sq. FL <br />MAIN LEVEL <br />1100 <br />SECOND LEVEL <br />0 <br />TOTAL AIM SM FT. (SMCra * <br />17W <br />IMEIHODDLOOY: ANIN ZT85- 0.9 <br />The total area calcuWad from iM outsidtrto-outside OT framing. inckx kp opbonal firiMed basement op6are as <br />own. shThe area excludes stairwel at Nghest level above grade, garage, covered paboA ordm <br />^a�FLY vJI fF' PREVAILING <br />r li DINGC.00E. <br />-�a,EC' RIC CODE, <br />()c 7FpNYRNI;.!.5 <br />If t"INANCES <br />W iOr IC.M MUSE CRAWA <br />01" MOM 011MATIN un <br />CO MAOM AD am R." <br />YSOIE COartacTrx %m <br />DW N IYN C O <br />aPECM :C IlL 1C11 FOR <br />M <br />6m PRN- Vf SCII6 rtO F <br />HEM OF <br />a[fGlml ANY DtlCl <br />(CIIIIEN 6, dl®rtATM VC <br />rlda V <br />emmu aFAEImm"aw orT <br />eedl" &WILL 0E Im Awro 6m <br />Ia1M'A ta141 !E aeoRl® n <br />OK" TO PEST ALL <br />8116OF LOCAL IKD1 1 <br />TO (p}LY aml 6T/ <br />V� <br />Qr <br />Q <br />ZJN <br />W � <br />O T� <br />J <br />WA l <br />� <br />LL <br />A <br />Lu <br />� u <br />x <br />��a <br />I <br />;.a <br />N <br />LO <br />c <br />C7 0 <br />O <br />C� <br />G <br />U <br />W <br />x <br />W <br />LL N <br />C> LMA <br />W <br />sImmR I m <br />HERSION: 5.0 <br />COVER SHEET <br />a!/ <br />
The URL can be used to link to this page
Your browser does not support the video tag.