.GENERAL STRUCTURAL NOTES:
<br />1. ALL WORK SHALL CONFORM TO THE 2023 8th EDITION OF THE FLORIDA QNTERNATIONAL)
<br />RESIDENTIAL CODE AND APPLICABLE COUNTY CODE AMENDMENTS. STANDARDS LISTED IN
<br />STRUCTURAL NOTE SECTIONS REFER TO THE VERSION AND EFFECTIVE DATE IDENTIFIED IN THE
<br />REFERENCED STANDARDS CHAPTER N THE GOVERNING BUILDING CODE NOTED ABOVE.
<br />2. THE STRUCTURAL NOTES ARE INTENDED TO AUGMENT THE DRAWINGS. SHOULD CONFLICTS
<br />EXIST BETWEEN THE DRAWINGS AND THE STRUCTURAL NOTES, THE STRICTEST PROVISION
<br />SHALL GOVERN.
<br />3. THE STRUCTURAL DRAWINGS FORM AN INTEGRAL PART OF CONTRACT DOCUMENTS, WHICH
<br />INCLUDE ARCHITECTURAL, STRUCTURAL. MECHANICAL, ELECTRICAL, AND CMLJSITE DRAWINGS.
<br />COORDINATE THE STRUCTURAL DRAWINGS WITH THE REQUIREMENTS SHOWN IN THE OTHER
<br />COMPONENTS OF THE CONTRACT DOCUMENTS.
<br />4. TYPICAL DETAILS AND OTHER SECTIONSIDETAILS APPLY TO CONDITIONS THAT ARE SIMILAR TO
<br />THE CONDITIONS DESCRIBED IN THE SECTIONSIDETAILS, EVEN IF THEY ARE NOT SPECIFICALLY
<br />REFERENCED ON THE PLANS.
<br />5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MEANS, METHODS SEQUENCES AND
<br />PROCEDURES OF CONSTRUCTION, INCLUDING BUT NOT LIMITED TO TEMPORARY SHORING AND
<br />BRACING.
<br />6. DO NOT SCALE STRUCTURAL DRAWINGS. IF DIMENSIONS ARE OMITTED OR NOT CLEAR,
<br />CONTACT THE ENGINEER,
<br />7. CONSTRUCTION SWILL COMPLY FULLY WITH THE APPLICABLE PROVISIONS OF OSHA AND THE
<br />LOCAL GOVERNING CODES, CURRENT EDITION, AND ALL REQUIREMENTS SPECIFIED N THE
<br />CODES SIULLL BE ADHERED TO AS IF THEY WERE CALLED FOR OR SHOWN ON THE DRAWINGS.
<br />THIS SHALL HOT BE CONSTRUED TO MEAN THAT REQUIREMENTS SET FORTH ON THE DRAWING
<br />MAY BE MODIFIED BECAUSE THEY ARE MORE STRINGENT THAN THE CODE REQUIREMENTS OR
<br />BECAUSE THEY ARE NOT SPECIFICALLY REQUIRED BY CODE.
<br />8. THE ENGINEER'S SEAL APPLIES ONLY TO THE STRUCTURAL COMPONENTS ON THIS DOCUMENT.
<br />ALL DIMENSIONS ARE TO BE VERIFIED WITH THE ARCHITECTURAL DRAWINGS. ANY DEVIATIONS
<br />OR DISCREPANCIES ON THESE PLANS MUST BE BROUGHT TO THE IMMEDIATE ATTENTION OF
<br />THE ENGINEER OF RECORD. BACK CHARGES WILL NOT BE ACCEPTED, REGARDLESS OF FAULT,
<br />WITHOUT PRIOR NOTIFICATION BY BUILDER WITHIN 4841OURS AND INVESTIGATION BY
<br />FIELDSTONE.
<br />9. THE TERMS'CONCRETE SCREW AND UASONRY SCREW SHALL BE USED INTERCHANGEABLY
<br />WITHIN THESE DRAWINGS. CONCRETEIMASONRY SCREWS AS GENERICALLY SPECIFIED WITHIN
<br />THESE DRAWINGS SHALL REFER TO ONE OF THE FOLLOWING ACCEPTED MANUFACTURER
<br />PRODUCTS: SIMPSON STRONG TIE TTEN TURBO, GENUINE TAPCON, OR HILTI KWIK-CON II.
<br />10. CONTENT LINKED WITHIN OR CODES THAT MAY BE SHOWN WITH THE DRAWING SET ARE FOR
<br />INFORMATIONAL PURPOSES ONLY AND THE PROFESSIONAL SEAL ON THIS DRAWING DOES NOT
<br />APPLY TO CONTENT CONTAINED WITHIN ANY OR CODES.
<br />11. POST INSTALLED EPDXY ANCHORAGE GENERICALLY NOTED WITHIN THESE DRAWINGS SHALL BE
<br />EITHER SIMPSON STRONG TIE SET-3G, OR HILTI HIT-HY-150
<br />DESIGN CRITERIA:
<br />1. BUILDING RISK CATEGORY =11
<br />2. VERTICAL LOADING:
<br />ROOF TOP CHORD LIVE LOAD =20 PSF (REDUCIBLE)
<br />ROOF TOP CHORD DEAD LOAD =7 PSF
<br />ROOF TOP CHORD DEAD LOAD (TILE) =15 PSF
<br />ROOF BOTTOM CHORD LIVE LOAD (W/ STORAGE) =20 PSF
<br />ROOF BOTTOM CHORD LIVE LOAD (W/o STORAGE) =10 PSF
<br />ROOF BOTTOM CHORD DEAD LOAD =10 PSF
<br />FLOOR LINE LOAD =40 PSF
<br />FLOOR LIVE LOAD (SLEEPING ROOMS) =30 PSF
<br />FLOOR DEAD LOAD =15 PSF
<br />DECKBALCONY LIVE LOAD -40 PSF
<br />NOTE TO TRUSS 8 IJOIST MANUFACTURERS - ROOF 6 FLOOR SYSTEM DELEGATED DESIGN
<br />SHALL CONFORM TO THE FOLLOWING DESIGN STANDARDS:
<br />LOCATION
<br />TOTAL LOAD
<br />WE LOAD
<br />MAX TOOT AL
<br />ON
<br />ROOF TRUSSES
<br />U240
<br />L240
<br />1'
<br />FLOOR JOISTS/TRUSS
<br />LIM
<br />LJ480
<br />112'
<br />NOTES:
<br />1. MAXIMUM TOTAL LOAD DIFFERENTIAL DEFLECTION BETWEEN ADJACENT PARALLEL
<br />MEMBERS SHALL BE 5/6'
<br />2. ANY MEMBER SUPPORTING BRICK/MASONRY SHALL BE LIMITED TO A TOTAL LOAD
<br />DEFLECTION OF LJ600
<br />3. FIELDSTONE AE CANNOT BE HELD RESPONSIBLE FOR ANY STRUCTURAL ISSUES RELATED
<br />TO ANY BUILDING COMPONENT IF COMPONENT SHOP DRAWINGS ARE NOT SUBMITTED TO
<br />FARE FOR REVIEW PRIOR TO FABRICATION, DELIVERY, OR INSTALLATION
<br />3. LATERAL LOADING
<br />WIND CRITERIA: TORNADO WIND SPEED _, _ _-NIA
<br />BASIC WIND SPEED =140 MPH
<br />EXPOSURE CATEGORY =C
<br />INTERNAL PRESSURE COEFFICIENT = +/- 0.18 (ENCLOSED)
<br />SEISMIC CRITERIA
<br />SITE CLASS =D
<br />SEISMIC DESIGN CATEGORY =A
<br />4. EARTH PRESSURE LOADING:
<br />ALLOWABLE SOIL BEARING CAPACITY
<br />TOTAL LOADS (INCLUDING WIND 6 SEISMIC) =2000 PSF
<br />LATERAL EARTH EOUNALENT FLUID PRESSURE
<br />WALLS UNBRACED AT TOP =40 PCF
<br />WALL BRACED AT TOP =55 PCF
<br />5. GUARDRAILHANDRAIL LOADING:
<br />ALL GUARDRAILMANDRAILS SHALL MEET 200 LIDS (MINIMUM) CONCENTRATED FORCE APPLIED
<br />IN ANY DIRECTION. IN -FILL COMPONENTS OF GUARDRAIL SHALL MEET 50 PSF. THESE LOADS
<br />ARE TO BE EVALUATED INDEPENDENTLY AND ARE NOT TO ACT CONCURRENTLY WTH ANY
<br />OTHER LIVE LOAD. DEFLECTION OF GUARDRAIL SHALL MEET THE CRITERIA SET FORTH BY THE
<br />INTERNATIONAL CODE COUNCIL EVALUATION SERVICES QCC-ES) AC 273 -'ACCEPTANCE
<br />CRITERIA FOR HANDRAILS AND GUARDS'
<br />CONCRETE NOTES:
<br />1. STRUCTURAL CONCRETE HAS BEEN DESIGNED IN ACCORDANCE PER ACI 332'RESIDENTIAL
<br />CODE REQUIREMENTS FOR STRUCTURAL CONCRETE'.
<br />2. CONCRETE PRODUCTION AND PLACEMENT SHALL CONFORM TO THE REOUREMENTS OF ACI 332
<br />'RESIDENTIAL CODE REQUIREMENTS FOR STRUCTURAL CONCRETE' EXCEPT AS MODIFIED BY
<br />STRUCTURAL REQUIREMENTS NOTED ON THE DRAWINGS.
<br />3. CEMENT SHALL CONFORM TO ASTM C750'SPECIFICATION FOR PORTLAND CEMENT.' CONCRETE
<br />SHALL BE NORMAL WEIGHT, UNLESS INDICATED OTHERWISE.
<br />4. CONCRETE AGGREGATES SHALL CONFORM TO ASTM C33'SPECIFICATION FOR CONCRETE
<br />AGGREGATES.'
<br />5. REINFORCING SHALL L CONFORM TO ASTM A-615 GRADE 60.
<br />6. REINFORCEMENT SHALL BE FABRICATED AND ERECTED ACCORDING TO THE ACI STANDARDS:
<br />'DETAILS AND DETAILING OF CONCRETE REINFORCEMENT, ACI 315 - AND "MANUAL OF
<br />ENGINEERING AND PLACING DRAWINGS FOR REINFORCED CONCRETE STRUCTURES%ACI 315R.
<br />7. REINFORCING STEEL AND WELDED WIRE FABRIC SHALL BE PLACED WITH MINIMUM CONCRETE
<br />COVER AND TOLERANCES AS FOLLOWS:
<br />SLABON43R1ADC: WITHIN UPPER 213 OF SLAB AND 3/4" MINIMUM COVER AT INTERIOR
<br />CONDITIONS; 1-12' MINIMUM COVER AT EXTERIOR CONDITIONS
<br />OONC EIE V OUNDATM AGAINST- EARnt 3'
<br />FOAM® CONCRETE: 1-12- (#5 REBAR OR SMALLER) 2- (#6 REBAR OR LARGER)
<br />TOLERANCE: +/- 318"
<br />8. REINFORCING STEEL SHALL NOT BE CUT, BENT OR STRAIGHTENED IN THE FIELD UNLESS
<br />APPROVED BY THE STRUCTURAL ENGINEER OR AS INDICATED ON THE DRAWINGS.
<br />9. WELDING OF REINFORCING STEEL IS PROHIBITED UNLESS SPECIFICALLY DETAILED. WELDING
<br />WHERE DETAILED SHALL CONFORM TO AWS D1 A SPECIFICATION.
<br />CONCRETE NOTES (CONTINUED):
<br />10. CONCRETE SHALL HAVE A MINIMUM 28-DAY COMPRESSIVE STRENGTH AS FOLLOWS:
<br />FOUNDATIONS 6 FOUNDATION WALLS: 25W PSI
<br />SLAB -ON -GRADE 8 CONCRETE BEAMS: 2500 PSI
<br />11. CONTRACTOR SHALL TIE REINFORCING STEEL SECURELY IN PLACE PRIOR TO PLACING
<br />CONCRETE AND PROVIDE SUFFICIENT SUPPORTS TO MAINTAIN THEIR POSITION WITHIN
<br />SPECIFIED TOLERANCES DURING ALL CONSTRUCTION ACTIVITIES. INSERTING DOWELS INTO
<br />WET CONCRETE IS NOT PERMITTED. ANCHOR RODS AND STEEL INSERTS SHALL BE SET BY
<br />TEMPLATE TO WITIAN A 1/O' TOLERANCE IN ANY DIRECTION WITH MINIMUM EMBEDMENT AND
<br />EXACT PROJECTION INDICATED ON THE DRAWINGS, PRIOR TO PLACING CONCRETE.
<br />12. HOOKED BARS SHALL BE STANDARD 90 DEGREE HOOKS PER ACI UNLESS NOTED OTHERWISE ON
<br />THE DRAWINGS. MINIMUM LAP SPLICE SHALL BE CLASS B PER AG 318. LOCATION OF LAP
<br />SPLICES SHALL BE AS INDICATED ON CONSTRUCTION DOCUMENTS.
<br />13. DOWELS INTO FOUNDATION SHALL MATCH SIZE AND SPACING OF VERTICAL REINFORCEMENT AT
<br />ALL COLUMNS, PIERS AND WALLS, UNLESS OTHERWISE NOTED.
<br />14. CONTRACTOR SHALL OBTAIN APPROVAL PRIOR TO PLACING OPENINGS OR SLEEVES NOT SHOWN
<br />ON THE DRAWINGS, THROUGH ANY STRUCTURAL MEMBER.
<br />15. ONE OF THE FOLLOWING CONCRETE SLAB ON GRADE CRACK CONTROL METHODS SHALL BE
<br />USED (CONTRACTOR PREFERENCE):
<br />• CONTROL JOINTS: SHALL BE FORMED, SAWED, OR TOOLED TO A 1' MINIMUM DEPTH WITHIN
<br />24 HOURS OF CONCRETE PLACEMENT. MAXIMUM JOINT SPACING FOR UNREINFORCED SLAB
<br />IS AS FOLLOWS:
<br />3-12' SLAB: 8 FEET O.C. EACH DIRECTION
<br />4' SLAB: 10 FEET O.C. EACH DIRECTION
<br />• WELDED WARE FABRIC (W.W.F.) 6X6-W1.4XW1.4. WELDED WIRE FABRIC SHALL BE FURNISHED IN
<br />FLAT SHEETS (ROLLS NOT PERMITTED) AND SHALL CONFORM TO ASTM A-1064 AND HAVE A
<br />MINIMUM SIDE AND END LAP OF 8INCHES.
<br />• MICRO- OR MACRO- SYNTHETIC FIBER REINFORCEMENT
<br />FIBER LENGTHS SHALL BE 12' TO 2-1/4' IN LENGTH. DOSAGE AMOUNT SHALL BE FROM 3/4 TO
<br />3.0 POUNDS N ACCORDANCE WTH MANUFACTURERS RECOMMENDATIONS. SYNTHETIC
<br />FIBERS SHALL COMPLY WITH ASTM C1116. THE MANUFACTURER/SUPPLIER SHALL PROVIDE
<br />CERTIFICATION OF COMPLIANCE WITH ASTM C1116 WHEN REOUESTED BY THE BUILDING
<br />OFFICIAL
<br />16. CONTROL JOINTS SHALL BE FURNISHED WITH A FULL-LENGTH KEYWAY CENTERED ON MEMBERS.
<br />WHERE THE SIZE OF KEY IS NOT SHOWN ON THE DRAWINGS, THE KEY SHALL BE 25% OF THE
<br />CROSS-SECTION DIMENSION OF THE MEMBER AND MINIMUM 1-1/2 INCHES INTO THE FIRST POUR
<br />OF CONCRETE.
<br />17. PROVIDE POCKETS OR RECESSES IN CONCRETE WORK FOR COLUMNS AND BEAMS AS REQUIRED
<br />EVEN IF NOT SHOWN ON THE DRAWINGS. PROVIDE CONCRETE FILL AFTER BEAM ERECTION.
<br />1 S. CURING OF CONCRETE SURFACES SHALL CONFORM TO ACI 308.1 'STANDARD SPECIFICATION
<br />FOR CONCRETE CURING' AND ACI WSR "GUIDE TO CURING CONCRETE".
<br />FOUNDATION NOTES:
<br />1. CONTRACTOR SHALL VERIFY ALL CONDITIONS, INCLUDING UNDERGROUND UTILITIES AND FIELD
<br />MEASUREMENTS AT JOB SITE AND REPORT ANY DISCREPANCIES TO OWNERS REPRESENTATIVE.
<br />2. TOP OF SPREAD FOOTING ELEVATIONS NOTED ON PLAN ARE MINIMUM ELEVATIONS. IN ALL CASES
<br />FOOTINGS ARE TO BEAR ON UNDISTURBED NATURAL SOILS OR ENGINEERED FILL HAVING A
<br />MINIMUM NET ALLOWABLE BEARING CAPACITY OF 2000 PSF.
<br />3. SIDES OF FOUNDATIONS SHALL BE FORMED UNLESS CONDITIONS PERMIT EARTH FORMING.
<br />FOUNDATIONS POURED AGAINST THE EARTH REQUIRED THE FOLLOWING PRECAUTIONS: SLOPE
<br />SIDES OF EXCAVATIONS AS APPROVED BY GEOTECHNICAL ENGINEER AND CLEAN UP SLOUGHING
<br />BEFORE AND DURING CONCRETE PLACEMENT. PROVIDE POLYETHYLENE VAPOR RETARDER
<br />COMPLYING WITH GOVERNING BUILDING CODE LISTED ON THIS SHEET AGAINST SOILS WHERE
<br />CONCRETE IS TO BE PLACED; LAP ALL EDGES 6 NCH (MINIMUM) AND SEAL WITH ADHESIVE.
<br />4. WHERE FOOTING STEPS ARE NECESSARY, THEY SHALL BE NO STEEPER THAN ONE VERTICAL TO
<br />TWO HORIZONTAL U.N.O.
<br />5. FOOTINGS SHALL BE CENTERED UNDER COLUMNS AND WAILS UNLESS SPECIFICALLY DETAILED
<br />OTHERWISE ON THE DRAWINGS.
<br />6. NO FOOTINGS OR SLABS SHALL BE PLACED ON OR AGAINST SUB -GRADE CONTAINING FREE
<br />WATER, FROST OR ICE. SHOULD WATER OR FROST, HOWEVER SLIGHT, ENTER A FOOTING
<br />EXCAVATION AFTER SUB -GRADE APPROVAL, THE SUB -GRADE SHALL BE RE INSPECTED BY THE
<br />GEOTECHNICAL ENGINEER/ TESTING LABORATORY AFTER REMOVAL OF WATER OR FROST.
<br />7. CONTRACTOR SHALL FURNISH ALL REQUIRED DE WATERING EQUIPMENT TO MAINTAIN A DRY
<br />EXCAVATION UNTIL BACKFILL IS COMPLETE.
<br />8. A GEOTECHNICAL ENGINEER REGISTERED IN THE STATE OF WORK PERFORMED SHALL INSPECT
<br />THE CONDITION AND ASSURE THE ADEQUACY OF ALL SITE PREPARATION, SUBGRADES, FILLS,
<br />BACKFILLS BEFORE PLACEMENT OF FOUNDATIONS, FOOTINGS, SLABS AND WALLS. HE SHALL
<br />SUBMIT REPORT TO THE ARCHITECT/ENGINEER DESCRIBING HIS INVESTIGATIONS OF ANY
<br />NON -CONFORMING WORK
<br />BACKFILLING:
<br />1. DO NOT PLACE SAC FILL AGAINST FOUNDATION WALLS - DESIGNED AS SUPPORTED AT TOP AND
<br />BOTTOM - UNTIL BASEMENT LEVEL AND FIRST FLOOR SYSTEM ARE IN PLACE SHORE AND/OR
<br />BRACE WAILS AS REQUIRED IF BACKFILLING OPERATIONS ARE TO BE CARRIED OUT PRIOR TO
<br />PLACEMENT OF FLOOR SYSTEM.
<br />2. WHERE BACKFILL IS TO BE PLACED ON BOTH SIDES OF FOUNDATION WALLS, PROVIDE A
<br />BALANCED SACKFLL AGAINST FOUNDATION WAITS TO ELIMINATE LATERAL LOAD EFFECTS, OR
<br />PROVIDE NECESSARY TEMPORARY LATERAL SUPPORT TO THE TOP OF THE WALL UNTIL
<br />PERMANENT SUPPORT IS INSTALLED.
<br />3. BACKFILL MATERIAL SHALL CONSIST OF CLEAN, WELL GRADE GRANULAR SOILS, FREE OF
<br />ORGANIC MATERIAL AND BE COMPACTED TO 95% OF MAXIMUM DENSITY, AS DETERMINED BY
<br />THE MODIFIED PROCTOR METHOD (ASTM D1557), IN LIFTS NOT EXCEEDING 8 INCHES.
<br />MASONRY NOTES:
<br />1. CONCRETE MASONRY HAS BEEN DESIGNED IN ACCORDANCE WITH ACI 530. -BUILDING CODE
<br />REQUIREMENTS FOR MASONRY STRUCTURES' AND SHALL BE CONSTRUCTED IN ACCORDANCE
<br />WITH ACI 530.1. "SPECIFICATIONS FOR MASONRY STRUCTURES.'
<br />2. CONCRETE MASONRY SHALL CONFORM TO ASTM C90 AND HAVE A MINIMUM COMPRESSIVE
<br />STRENGTH Pm - 1,5W PSI U.O.N. MASONRY SHALL HAVE A TEXTURE SUITABLE FOR STUCCO
<br />APPLICATIONS WHERE ARCHITECTURAL DRAWINGS INDICATE STUCCO APPLICATION.
<br />3. CONCRETE MASONRY UNITS SHALL BE LAID IN RUNNING BOW.
<br />4. MORTAR FOR ALL MASONRY SHALL CONFORM TO ASTM C270 WITH MINIMUM COMPRESSIVE
<br />STRENGTH OF 2,000 PSI. MORTAR BELOW GRADE SHALL BE TYPE M. ELSEWHERE MORTAR MAY
<br />BE EITHER TYPE M OR S UNLESS SPECIFICALLY INDICATED OTHERWISE. USE EITHER PORTLAND
<br />CEMENTNME OR MASONRY CEMENT FOR MORTAR.
<br />S. GROUT SHALL CONFORM TO ASTM C476 WITH MINIMUM 28-DAY COMPRESSIVE STRENGTH OF
<br />2,500 PSI.
<br />6. STEEL BAR REINFORCEMENT SHALL CONFORM TO ASTM A61 S. GRADE 60.
<br />7. VERTICAL CELLS CONTAINING REINFORCING AND GROUT SHALL FORM A CONTINUOUS CAVITY,
<br />FREE OF MORTAR DROPPINGS.
<br />8. VERTICAL CMU WALL REINFORCING SHALL BE AS NOTED ON THE DRAWINGS. DOWELS TO
<br />CONCRETE FOUNDATION TO MATCH SIZE AND SPACING OF VERTICAL REINFORCING UNLESS
<br />NOTED OTHERWISE REINFORCE CMU CORE AT CORNERS, EACH SIDE OF CONTROL JOINTS AND
<br />EACH SIDE OF WALL OPENINGS WITH (1)-*5 CONTINUOUS VERTICAL REINFORCING BARS..
<br />9. HORIZONTAL BOND BEAM AND VERTICAL REINFORCING SHALL BE CONTINUOUS U.O.N. LAP
<br />SPLICE REINFORCING PER THE SCHEDULE OR USE MECHANICAL SPLICES ADEQUATE FOR 125%
<br />OF SPECIFIED YIELD STRENGTH OF THE BAR. LAP VERTICAL REINFORCEMENT WITH MINIMUM
<br />DOWELS OF SAME SIZE AND SPACING THAT HAVE BEEN PREVIOUSLY INSTALLED IN THE
<br />FOUNDATIONS. DOWEL EMBEDMENT IN CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF
<br />THE CONCRETE NOTES.
<br />BAR SIZE
<br />LAP SPLICE LENGTH
<br />BEND DIAMETER
<br />ACI HOOK
<br />#4
<br />20"
<br />3'
<br />10'
<br />#5
<br />25'
<br />3.3/4-
<br />10'
<br />#6
<br />34'
<br />4-1/2'
<br />11"
<br />MASONRY NOTES (CONTINUED):
<br />10. REINFORCING BARS SHALL BE HELD IN POSITION BY WIRE TIES OR OTHER APPROVED MEANS TO
<br />ENSURE DESIGN LOCATION AND LAP. PLACE BARS AND LAP PRIOR TO GROUTING.
<br />11. GROUTING OF MASONRY WALLS SHALL CONFORM TO RECOMMENDED PROCEDURE FOR 'LOW
<br />LIFT GROUTING' OR'HNGI LIFT GROUTING' AS OUTLINED IN THE NCMA-TEK 3-2A -GROUTING
<br />FOR CONCRETE MASONRY WALLS AND ACI 5WASCE 5 SPECIFICATION FOR MASONRY
<br />STRUCTURES. GROUT LIFTS SHALL NOT EXCEED 5 FEET WITHOUT MECHANICALLY
<br />CONSOLIDATED (VIBRATED) GROUT POURS.
<br />12. LIFTS OF GROUT SHALL BE KEYED 41NCHES INTO THE PREVIOUS COURSE OF MASONRY BELOW.
<br />13. MASONRY BELOW GRADE SHALL BE GROUTED SOLID.
<br />14. CONTRACTOR SHALL BRACE MASONRY WALLS TO RESIST WIND LOADS UNTIL FLOORS AND
<br />ROOFS ARE IN PLACE, AND THE MASONRY HAS REACHED 75% OF THE REQUIRED STRENGTH PM.
<br />BRACING SHALL BE PROVIDED IN ACCORDANCE WITH OSHA - CONSTRUCTION SAFETY
<br />STANDARDS FOR MASONRY WALL BRACING AND NOMA TEK 3-48 -'BRACING CONCRETE
<br />MASONRY WALLS DURING CONSTRUCTION.'
<br />WOOD FRAMING NOTES:
<br />1. STRUCTURAL SAWN LUMBER, STRUCTURAL COMPOSITE LUMBER, AND CONNECTIONS HAVE
<br />BEEN DESIGNED IN ACCORDANCE WITH THE 'NATIONAL DESIGN SPECIFICATION FOR WOOD
<br />CONSTRUCTION.- (NDS)
<br />2. PLYWOOD HAS BEEN DESIGNED IN ACCORDANCE WITH 'PANEL DESIGN SPECIFICATION.- AND
<br />SHALL CONFORM TO -VOLUNTARY PRODUCT STANDARD PSI CONSTRUCTION AND INDUSTRIAL
<br />PLYWOOD.'
<br />3. ORIENTED STRAND BOARD (OSS) SHALL CONFORM TO -VOLUNTARY PRODUCT STANDARD PS2
<br />PERFORMANCE STANDARD FOR WOOD -BASED STRUCTURAL -USE PADS'.
<br />4. ALL BEAMS AND HEADERS SHALL BE (2)-PLY U.N.O.
<br />5. WOOD SILL PLATES AND WOOD WALLS SUPPORTED ON CONTINUOUS CONCRETE OR MASONRY
<br />SHALL BE ANCHORED WITH 12' DIAMETER CAST -IN -PLACE ANCHOR BOLTS WITH 7" EMBEDMENT,
<br />4' (MINIMUM) AND 12' (MAXIMUM) FROM END OF SILL PLATE(S), LOCATED WITHIN THE MIDDLE
<br />THIRD OF THE SILL PLATE, WITH NUT AND 3'x3'4229- WASHERS AT THE ANCHOR SPACING
<br />BELOW:
<br />MAXIMUM ANCHOR BOLT SPACING = 7-0' O.C.
<br />REFER TO 'PRE -APPROVED FIELD REPAIR NOTES' SECTION FOR ALTERNATE ANCHORAGE
<br />APPROVALS. FOR OTHER ANCHORS NOT LISTED, SUBMIT TO ENGINEER OR RECORD FOR
<br />REVIEW.
<br />6, ALL LUMBER N CONTACT WITH EARTH, CONCRETE, OR MASONRY - AND WOOD BEAMS
<br />POCKETING INTO CONCRETE OR MASONRY WALLS HAVING CLEARANCES LESS THAN 12' ON
<br />TOP, SIDES, AND END(S) SHALL BE PRESSURE TREATED OR SEPARATED WITH AN IMPERVIOUS
<br />MOISTURE BARRIER.
<br />7. STRUCTURAL SAWN LUMBER SHALL BE SPRUCE -PINE -FIR NO.1 11402 OR BETTER U.N.O. WITH
<br />BASE DESIGN VALUES:
<br />Fx= 875 PSI FG = 425 PSI FT = 450 PSI Fo= 1150 PSI Fv= 136 PSI E= 1400 KSI
<br />WITH THE MOISTURE CONTENT OF THE WOOD IN SERVICE WILL NOT EXCEED 19%.
<br />S. BEARING AND EXTERIOR WALL STUDS SHALL BE CAPPED WITH DOUBLE (2X) TOP PLATES
<br />INSTALLED TO PROVIDE OVERLAPPING AT CORNERS AND AT INTERSECTIONS. END JOINTS IN
<br />DOUBLE (2X) TOP PLATES SHALL BE OFFSET AT LEAST 24 INCHES AND SWILL BE NAILED WITH
<br />NOT LESS THAN (8)-0.162-x2-1 /2- FACE NAILS ON EACH SIDE THE JOINT. DOUBLE (2X) TOP PLATES
<br />OF On WALLS AND INTERIOR LOAD BEARING WALLS SHOWN ON DRAWINGS SHALL BE
<br />SOUTHERN YELLOW PINE NO2 OR BETTER WITH BASE DESIGN VALUES:
<br />Fa= 1100 PSI FG- 565 PSI FT- 675 PSI Fo- 1450 PSI Fv= 175 PSI E= 1400 KSI
<br />WITH THE MOISTURE CONTENT OF THE WOOD IN SERVICE WILL NOT EXCEED 19%.
<br />9. STRUCTURAL COMPOSITE LUMBER SHALL CONFORM TO ASTM D 5466 WITH THE FOLLOWING
<br />ALLOWABLE DESIGN STRESSES
<br />MIGFK L M LVL PARMIM PSL ('1 TV BERSTPA D LK
<br />E - 2000 KSI E - 1800 KSI E = 13DO KSI
<br />FIG - 2800 PSI Fs = 2400 PSI F,, = 1700 PSI
<br />C) -BOOZER BEAM 2.1 E' ARE AN ACCEPTED ALTERNATE TO PSL COLUMNS SPECIFIED
<br />ON PLANS PROVIDED THE BOOZER BEAM 2.1 PIS OF EQUAL OR GREATER SECTION
<br />DIMENSION TO THE PSL COLUMN AND OF EQUAL OR LESSER HEIGHT
<br />10. FLOOR SHEATHING SHALL BE 23132 INCH, APA RATED SHEATHING 48124 MIN., EXPOSURE 1.
<br />INSTALL WITH THE LONG DIMENSION OR STRENGTH AXIS OF THE PANEL ACROSS SUPPORTS
<br />AND WITH PANEL CONTINUOUS OVER TWO OR MORE SPANS. PANEL EDGES SHALL BE
<br />TONGUE -AND -GROOVE. FLOOR SHEATHING SHALL BE GLUED AND NAILED TO SUPPORTING
<br />MEMBERS. ADHESIVE SHALL MEET APA SPECIFICATION AFG.01, APPLIED IN ACCORDANCE WITH
<br />THE MANUFACTURERS RECOMMENDATIONS. PROVIDE 0.1 31N2-1/2" COMMON NAILS AT 6 INCH
<br />O.0 ALONG SUPPORTED PANEL EDGES AND 12 INCH O.0 AT INTERMEDIATE SUPPORTS.
<br />11. FOR INTERIOR WALL HEADERS PROVIDE (1)-2X JACK STUD AND (1)-2X KING STUD U.N.O. ON
<br />DRAWINGS.
<br />12. FOR EXTERIOR WALL HEADERS PROVIDE (1)-2x JACK STUD AND (1)-2x KING STUD, MINIMUM,
<br />REFER TO CHART BELOW U.N.O ON DRAWINGS:
<br />WINDSPEED OF
<br /><= 140 EXP. C
<br />WAIL HEIGHT
<br />OFT
<br />9FT
<br />10FT
<br />STUD
<br />SIZE
<br />HEADER SPAN
<br />(FT)
<br />4
<br />1J/lK
<br />1J/IK
<br />1J/1K
<br />6
<br />1J/1K
<br />1J/1K
<br />1J/2K
<br />8
<br />1J/1K
<br />1J/2K
<br />1J/3K
<br />10
<br />1J/2K
<br />1J/2K
<br />1J/4K
<br />2x4
<br />12
<br />1J/2K
<br />1J/3K
<br />1J/4K
<br />14
<br />1J/2K
<br />iJ/4K
<br />ENG
<br />16
<br />1J/3K
<br />1J/4K
<br />ENG
<br />18
<br />1J/3K
<br />ENG
<br />ENG
<br />WINDSPEED OF
<br /><= 140 EXP. C
<br />WALL HEIGHT
<br />OFT
<br />9FT
<br />1OFT
<br />STUD
<br />SIZE
<br />HEADER SPAN
<br />(FT)
<br />4
<br />1J/1K
<br />IJ/1K
<br />1JYIK
<br />6
<br />1J/1K
<br />1J/1K
<br />INIK
<br />8
<br />1J/1K
<br />1J/1K
<br />IJ/1K
<br />10
<br />1NIK
<br />1J/iK
<br />1J/1K
<br />2x6
<br />12
<br />1J/1K
<br />1J/1K
<br />1J/1K
<br />14
<br />IJ/1K
<br />1J/1K
<br />1MK
<br />16
<br />1J/1K
<br />1J/1K
<br />1J/1K
<br />18
<br />1J/1K
<br />1J/1K
<br />iJ/1K
<br />13. WALLS SHOWN ON THE FRAMING PLANS ARE LOAD BEARING WALLS; WALLS NOT SHOWN ON
<br />STRUCTURAL FRAMING PLANS ARE INTERIOR NON -LOADING BEARING PARTITION WALLS.
<br />14. LOAD BEARING WALLS SHALL BE CONSTRUCTED WITH 2X STUDS AT 16' O.C. MAXIMUM U.N.O.
<br />NON -LOAD BEARING PARTITION WALLS SHALL BE CONSTRUCTED WITH 2X OR METAL STUDS (18
<br />GA. MIN.) @ 24' O.C. MAXIMUM.
<br />15. STUD COLUMNS UNDER LOAD BEARING POINTS OF GIRDERSBEAMS SHALL MATCH THE
<br />GIRDER/BEAM PLY COUNT WITHIN 117 TOLERANCE (2-PLY STUD COLUMN MINIMUM). SOLID
<br />BLOCK ALL GIRDERBEAMS THRU FLOOR SYSTEMS AND TO THE FOUNDATION.
<br />16. WHEN NOT SHOWN ON DRAWINGS OR DETAILS, THE RULING SCHEDULE FOR WOOD FRAMING
<br />ELEMENTS SHALL COMPLY WITH THE IRC TABLE R602.3(1),
<br />17. FLOOR SYSTEMS ARE DESIGNED BY THE TRUSS AND/OR WOOD I- JOIST MANUFACTURERS
<br />DELEGATED ENGINEER AND BE IN CONFORMANCE WITH THE LOADS d DEFLECTIONS IDENTIFIED
<br />IN THE DESIGN CRITERIA NOTES SECTION. INSTALL PER MANUFACTURERS RECOMMENDATIONS,
<br />NOTES, AND DETAILS. FLOOR FRAMING CONCEPT LAYOUTS SHOWN WITHIN THE DRAWINGS ARE
<br />FOR ILLUSTRATIVE PURPOSES ONLY TO DEPICT FLOOR SYSTEM -TO -WALL CONNECTIONS.
<br />CHANGES TO THE CONCEPTUAL FLOOR LAYOUT SHOWN IS NOT PERMITTED WITHOUT A LETTER
<br />AND REVIEW FROM THE ENGINEER OF RECORD. PREFABRICATED WOOD I -JOIST SHALL
<br />CONFORM TO ASTM D 5055.
<br />JURISDICTION SPECIFIC NOTES:
<br />1. FOR PARTIALLY ENCLOSED AREAS, INCLUDING BUT NOT LIMITED TO LANAIS, PORCHES, AND
<br />BALCONIES A 12- (MINIMUM) EXTERIOR GRADE SOFFIT BOARD WITH A CEMENTITIOUS
<br />KNOCKDOWN FINISH IS ACCEPTABLE PROVIDED THAT IT IS PAINTED MEETING THE
<br />REQUIREMENTS OF ASTM C932 TO GIVE THE CEILING WATER RESISTANCE. THE SOFFIT BOARD
<br />PRODUCT SHALL BE ATTACHED PER MANUFACTURER SPECIFICATIONS TO BE IN COMPLIANCE
<br />WITH R703.1.
<br />2. THE SOFFIT DESIGN PRESSURE IS AS NOTED IN THESE DOCUMENTS. WITH KAYCAN VINYL SOFFIT
<br />INSTALLED IN ACCORDANCE WITH MANUFACTURERS REOURRMENTS AND ICC-ES EVALUATION
<br />REPORT ESR-1495 THE SOFFIT WALL COMPLY WITH R703.1.
<br />PRE-ENGINEERED ROOF TRUSS NOTES:
<br />1. ROOF TRUSS SHOWN ON STRUCTURAL DRAWINGS IN CONCEPTUAL ONLY TO ILLUSTRATE
<br />TRUSS -TO WALL CONNECTIONS AND DOES NOT SERVE AS A ROOF TRUSS DESIGN. ROOF
<br />TRUSSES SHALL BE DESIGNED AND MANUFACTURED N CONFORMANCE FOR THE INDICATED
<br />LOADS WITH ANSI/TPI 1 'NATIONAL DESIGN STANDARD FOR METAL PLATE CONNECTED WOOD
<br />TRUSS CONSTRUCTION.' FINAL PRE-ENGINEERED ROOF TRUSS FRAMING LAYOUT AND DESIGNS
<br />TO BE BY ROOF MANUFACTURER'S DELEGATED ENGINEER.
<br />2. ROOF TRUSSES SHALL BE DESIGNED FOR THE SUPERIMPOSED LOADS IDENTIFED N THE
<br />DESIGN CRITERIA NOTES SECTION.
<br />3. THIS PLAN IS DEVELOPED FROM THE RENEW OF MASTER TRUSS FILES. ANY LOT THAT DEVIATES
<br />FROM THE MASTER TRUSS FILE ON RECORD,OR FOR PLANS FIELDSTONE AE IS NOT
<br />CONTRACTED TO PERFORM TRUSS RENEW ON, THE CONTRACTOR IS RESPONSIBLE TO ASSURE
<br />THE DIRECT COMPLIANCE OF TRUSS MANUFACTURER LAYOUT TO THESE DRAWINGS 6 VERIFY
<br />ALL TRUSS CONNECTORS ARE SUFFICIENT TO WITHSTAND THE UPUFTMTERAL LOADS IMPOSED
<br />4. TRUSS MANUFACTURER SHALL PROVIDE HANGERS AND CONNECTIONS ADEQUATE FOR LOADS
<br />AT ALL TRUSS -TO -TRUSS, TRUSST08EAM, AND BEAM -TO -TRUSS CONNECTIONS.
<br />5. REFER TO ARCHITECTURAL DRAWINGS FOR TRUSS SHAPE, OVERHANG, DIMENSIONS, SLOPES,
<br />SPANS, DRAINAGE, BEARING WALL HEIGHTS, ETC.
<br />6. THE POSITIONS, WEIGHTS, AND METHODS OF ATTACHMENTS OF ALL MECHANICAL UNITS,
<br />ELECTRICAL FIXTURES, PLUMBING, FIRE SPRINKLERS, ETC SHALL BE INCLUDED IN THE DESIGN
<br />OF THE TRUSSES BY THE TRUSS MANUFACTURER. SEE ARCHITECTURAL DRAWINGS FOR ATTIC
<br />ACCESS SIZE AND LOCATIONS.
<br />7. SUPERIMPOSED LOADS FROM SECONDARY FRAMING Q.E. SOFFITS, PARAPETS, VALLEY FRAMING,
<br />UPPER TRUSSES, ETC) SHALL BE INCLUDED IN THE DESIGN OF SUPPORTING TRUSSES.
<br />8. CONTRACTOR TO PROVIDE TRUSS BRACING PER BCSI-W IN ADDITION TO PERMANENT BRACING
<br />SHOWN ON THE TRUSS DESIGN PROVIDED BY THE DELEGATED TRUSS ENGINEER.
<br />PRE -APPROVED FIELD REPAIR NOTES:
<br />1. MISPLACED DOWEL REPAIR: THIS NOTE DESCRIBES ALTERNATES TO MITIGATE THE CASTING OF
<br />REBAR VERTICAL REINFORCEMENT AT AN INCORRECT LOCATION.
<br />IF THE WALL HAS NOT BEEN BUILT: DRILL AND EPDXY #5 REBAR (36' LG.) INTO THE THICKENED
<br />EDGE OF SLAB AT THE CORRECT LOCATION. AS WALL IN CONSTRUCTED, LAP REBAR IN
<br />ACCORDANCE WITH MASONRY NOTES LAP SCHEDULE, PLACING A HOOKED BAR WTH 12- LAP AT
<br />THE TOP OF WALL WITH THE CONTINUOUS REBAR IN THE TIE BEAMA30ND BEAM. COMPLETE
<br />GROUTING OF WALL.
<br />IF THE WALL HAS ALREADY BEEN BUILT: PRIOR TO GROUT PLACEMENT, OPEN THE WALL AT THE
<br />CORRECT LOCATION APPROXIMATELY 10' (H) x 4' (W) AT FLOOR LEVEL. DRILL AND EPDXY #5
<br />REM (32- LG.) INTO THE THICKENED EDGE OF SLAB. LAP VERTICAL REINFORCEMENT IN
<br />ACCORDANCE WITH MASONRY NOTES LAP SCHEDULE, PLACING A HOOKED BAR WITH 12" LAP AT
<br />THE TOP OF WALL WITH THE CONTINUOUS REBAR IN THE TIE BEAM/BOND BEAM. COMPLETE
<br />GROUTING OF WALL
<br />2. MISSINGIMISPLACED ANCHOR BOLT: ALTERNATE SILL PLATE ANCHORAGE SOLUTIONS
<br />Biro CONCRETE:
<br />A 1/2'x6' TITEN HD WITH 1-3W MINIMUM EDGE DISTANCE AND 6' MINIMUM END DISTANCE IS A
<br />DIRECT 1:1 REPLACEMENT FOR A 1/2' DIAMETER ANCHOR BOLT WITH 7' EMBEDMENT INTO
<br />A 1/7 THREADED ROD SET-3G EPDXY 7' EMBEDMENT WITH 1 V4' MINIMUM EDGE DISTANCE AND
<br />7-12' MINIMUM END DISTANCE IS A DIRECT 1:1 REPLACEMENT FOR A 1/2" DIAMETER ANCHOR
<br />BOLT WITH 7" EMBEDMENT INTO CONCRETE.
<br />NEO BROW F LLR) MASONRY IOPCMA:
<br />A 1/2X6- TTEN HD WITH 1-3µ" MINIMUM EDGE DISTANCE AND 8- MINIMUM END DISTANCE AT 4'-8'
<br />O.C. REPLACES A 12' DIAMETER ANCHOR BOLT WITH T EMBEDMENT AT V-O" O.C.; LIKEWISE A
<br />1/216' TTEN HD WITH 1-314' MINIMUM EDGE DISTANCE AND 8' MINIMUM END DISTANCE AT 7-0"
<br />O.C. REPLACES A 12- DIAMETER ANCHOR BOLT WITH T EMBEDMENT AT V-0" O.C..
<br />3. SIMPSON MASA SILL ANCHORS MAY BE USED AS AN ALTERNATE TO THE ANCHOR BOLTS AND
<br />SPACING NOTED HERE -IN ACCORDING TO THE FOLLOWING TABLE:
<br />BASIC WIND
<br />SPEED (MM
<br />MAXIMUM
<br />SPACING
<br /><140
<br />&-(r
<br />140
<br />1'$
<br />150
<br />V-7
<br />NOTES:
<br />1. MASA SPACING BASED ON NO MORE THAN ONE IN THREE INSTALLED WITH ONE LEG
<br />INSTALLED VERTICALLY ATTACHED TO STUD
<br />MISSING/MISPLACED TRUSS STRAP ANCHOR: REFER TO "MISSED TRUSS STRAP REPAIR" DETAIL
<br />WITHIN DRAWINGS.
<br />FOR MISLOCATED TRUSS ANCHORS WHICH ARE GREATER THAN 1/8" BUT LESS THAN 1.12" FROM
<br />THE FACE OF THE TRUSS, A SHIM SHALL BE PROVIDED AND NAIL LENGTH INCREASED TO
<br />PENETRATE THROUGH BOTH PLYS OF MATERIAL (I.E. 3- LG. NAILS). WHEN GAP IS GREATER THAN
<br />1-1/2", INSTALL NEW ANCHORS.
<br />MASONRY WALL OVERHANGING SLAB
<br />< 518" NO REPAIR REO'D
<br />5/8" < OVERHANG < 1-1/2' GROUT SOLID BOTTOM 3 COURSES OF AFFECTED WALL LENGTH
<br />> 1-12' CONTACT ENGINEER OF RECORD FOR REPAIR
<br />NOTCHED TOP PLATES 8 STUDS REQUIRING REPAIR
<br />AT SIDE STRUCTURAL REPAIR IS REQUIRED AT STUDS WHEN A STUD IS NOTCHED TO A DEPTH
<br />GREATER THAN 25% OF THE WIDTH IN BEARING WALLS, OR 40% N NON -LOAD BEARING WALLS;
<br />OR WHEN A HOLE IS DRILLEDBORED TO A DIAMETER EXCEEDING 40% OF THE STUD WIDTH IN
<br />BEARING WALLS, OR 60%OF THE STUD WIDTH IN NOWBEARING WALLS. IF THE MAXIMUM
<br />HOLE/NOTCH SPECIFICATIONS ARE EXCEEDED THEN A STUD SHOE MUST BE INSTALLED. STUD
<br />SHOE REPAIRS ARE AS FOLLOWS: FOR 2X STUD USE HSS2-SDS1.5 WITH (12)-1/4'X7-12" SDS
<br />SCREWS. FOR MULTI -PLY 2X STUDS USE HSS2--#--SDS3 WITH (12)-1/4'X3- SIDS SCREWS. WHERE
<br />'#" CORRESPONDS TO THE NUMBER OF STUDS IN THE MULTFPLY.
<br />AT TOP PLATER): A HOLE, CUT, OR NOTCH THAT IS GREATER THAN 50% OF THE PLATE WIDTH IS
<br />REMOVED FOR PIPING (EXCEPT WHEN THE SIDE OF THE WALL WITH THE NOTCH OR CUT IS
<br />COVERED BY WOOD STRUCTURAL PANEL SHEATHING), OR THE PLATES ARE CUT THROUGH. THE
<br />REQUIRED REPAIR IS A GALVANIZED 16-GAUGE METAL TIE THAT IS AT LEAST 1.12" WIDE AND
<br />MUST BE FASTENED WITH (8)-16D NAILS ON EACH SIDE OF THE OPENING.
<br />OHO Fieldstone JpMIN qlj
<br />.. �C� /,
<br />C.O.A.# ARCHITECURE: .`�..�_r%�GS/• ��
<br />AA26002802
<br />C.O.E.# ENGINEERING:
<br />29349
<br />O IBRAHEM ELAYEB, PE
<br />P.E.# 91476
<br />■ BENJAMIN NIESE, PE
<br />P.E.# 86025
<br />05/06/2024
<br />DATE
<br />No.860 _
<br />RIO/' • ����
<br />AL
<br />mwftm
<br />3400 Aubum Rd
<br />Suite 200
<br />Aubum Hills, MI 48326
<br />+1 248.622.4035
<br />F bi lde
<br />12906 Tampa Oaks Blvd.
<br />Suite 150
<br />Tampa, FL 33637
<br />+1 813.466.3310
<br />www.heidstoneae.com
<br />A
<br />L7A
<br />I I DRAWN BY: I FAE I I
<br />VERSION: 5.0
<br />SHEET NAME
<br />COVER SHEET
<br />SHEET #
<br />SO.1-140