GENERAL STRUCTURAL NOTES: <br />1. ALL WORK SHALL CONFORM TO THE 2023 ft EDITION OF THE FLORIDA (INTERNATIONAL) <br />RESIDENTIAL CODE AND APPLICABLE COUNTY CODE AMENDMENTS. STANDARDS LISTED IN <br />STRUCTURAL NOTE SECTIONS REFER TO THE VERSION AND EFFECTIVE DATE IDENTIFIED IN THE <br />REFERENCED STANDARDS CHAPTER IN THE GOVERNING BUILDING CODE NOTED ABOVE. <br />2. THE STRUCTURAL NOTES ARE INTENDED TO AUGMENT THE DRAWINGS. SHOULD CONFLICTS <br />EXIST BETWEEN THE DRAWINGS AND THE STRUCTURAL NOTES, THE STRICTEST PROVISION <br />SHALL GOVERN. <br />3. THE STRUCTURAL DRAWINGS FORM AN INTEGRAL PART OF CONTRACT DOCUMENTS, WHICH <br />INCLUDE ARCHITECTURAL. STRUCTURAL. MECHANICAL, ELECTRICAL, AND CIVIL/SITE DRAWINGS. <br />COORDINATE THE STRUCTURAL DRAWINGS WITH THE REQUIREMENTS SHOWN IN THE OTHER <br />COMPONENTS OF THE CONTRACT DOCUMENTS. <br />4. TYPICAL DETAILS AND OTHER SECTIONS/DETAILS APPLY TO CONDITIONS THAT ARE SIMILAR TO <br />THE CONDITIONS DESCRIBED IN THE SECTIONS/DETAILS, EVEN IF THEY ARE NOT SPECIFICALLY <br />REFERENCED ON THE PLANS. <br />5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MEANS, METHODS SEQUENCES AND <br />PROCEDURES OF CONSTRUCTION, INCLUDING BUT NOT LIMITED TO TEMPORARY SHORING AND <br />BRACING. <br />6. DO NOT SCALE STRUCTURAL DRAWINGS. IF DIMENSIONS ARE OMITTED OR NOT CLEAR, <br />CONTACT THE ENGINEER. <br />7. CONSTRUCTION SHALL COMPLY FULLY WITH THE APPLICABLE PROVISIONS OF OSHA AND THE <br />LOCAL GOVERNING CODES, CURRENT EDITION, AND ALL REQUIREMENTS SPECIFIED IN THE <br />CODES SHALL BE ADHERED TO AS IF THEY WERE CALLED FOR OR SHOWN ON THE DRAWINGS. <br />THIS SHALL NOT BE CONSTRUED TO MEAN THAT REQUIREMENTS SET FORTH ON THE DRAWING <br />MAY BE MODIFIED BECAUSE THEY ARE MORE STRINGENT THAN THE CODE REQUIREMENTS OR <br />BECAUSE THEY ARE NOT SPECIFICALLY REQUIRED BY CODE. <br />S. THE ENGINEER'S SEAL APPLIES ONLY TO THE STRUCTURAL COMPONENTS ON THIS DOCUMENT. <br />ALL DIMENSIONS ARE TO BE VERIFIED WITH THE ARCHITECTURAL DRAWINGS. ANY DEVIATIONS <br />OR DISCREPANCIES ON THESE PLANS MUST BE BROUGHT TO THE IMMEDIATE ATTENTION OF <br />THE ENGINEER OF RECORD. BACK CHARGES WILL NOT BE ACCEPTED, REGARDLESS OF FAULT, <br />WITHOUT PRIOR NOTIFICATION BY BUILDER WITHIN 48-HOURS AND INVESTIGATION BY <br />FIELDSTONE. <br />9. THE TERMS 'CONCRETE SCREW AND ?MASONRY SCREW SHALL BE USED INTERCHANGEABLY <br />WITHIN THESE DRAWINGS. CONCRETEUASONRY SCREWS AS GENERICALLY SPECIFIED WITHIN <br />THESE DRAWINGS SWELL REFER TO ONE OF THE FOLLOWING ACCEPTED MANUFACTURER <br />PRODUCTS: SIMPSON STRONG TIE TITEN TURBO, GENUINE TAPCON, OR HILT MARK -CON I. <br />10. CONTENT LINKED WITHIN OR CODES THAT MAY BE SHOWN WITH THE DRAWING SET ARE FOR <br />INFORMATIONAL PURPOSES ONLY AND THE PROFESSIONAL SEAL ON THIS DRAWING DOES NOT <br />APPLY TO CONTENT CONTAINED WITHIN ANY OR CODES. <br />11. POST INSTALLED EPDXY ANCHORAGE GENERICALLY NOTED WITHIN THESE DRAWINGS SHALL BE <br />EITHER SIMPSON STRONG TIE SET3G, OR HILT HIT4HY-150 <br />DESIGN CRITERIA: <br />1. BUILDING RISK CATEGORY =11 <br />2. VERTICAL LOADING: <br />ROOF TOP CHORD LIVE LOAD =2D PSF (REDUCIBLE) <br />ROOF TOP CHORD DEAD LOAD =7 PSF <br />ROOF TOP CHORD DEAD LOAD (TILE) =15 PSF <br />ROOF BOTTOM CHORD LIVE LOAD (w/ STORAGE) 20 PSF <br />ROOF BOTTOM CHORD LIVE LOAD (w/o STORAGE) =10 PSF <br />ROOF BOTTOM CHORD DEAD LOAD =10 PSF <br />FLOOR LIVE LOAD =40 PSF <br />FLOOR LIVE LOAD (SLEEPING ROOMS) =30 PSF <br />FLOOR DEAD LOAD =15 PSF <br />DECK/BALCONY LIVE LOAD =40 PSF <br />NOTE TO TRUSS 6 HOIST MANUFACTURERS - ROOF 6 FLOOR SYSTEM DELEGATED DESIGN <br />SHALL CONFORM TO THE FOLLOWING DESIGN STANDARDS: <br />LOCATION <br />TOTAL LOAD <br />LIVE LOAD <br />D�TOECTALLJ <br />ROOF TRUSSES <br />I L240 <br />I L240 <br />1 1" <br />FLOOR JOISTS/TRUSS <br />I L/360 <br />1 1 490 <br />1 112, <br />NOTES: <br />1. MAXIMUM TOTAL LOAD DIFFERENTIAL DEFLECTION BETWEEN ADJACENT PARALLEL <br />MEMBERS SHALL BE 5/8• <br />2. ANY MEMBER SUPPORTING BRICK/MASONRY SHALL BE LIMITED TO A TOTAL LOAD <br />DEFLECTION OF L/600 <br />3. FIELDSTONE AE CANNOT BE HELD RESPONSIBLE FOR ANY STRUCTURAL ISSUES RELATED <br />TO ANY BUILDING COMPONENT IF COMPONENT SHOP DRAWINGS ARE NOT SUBMITTED TO <br />FAE FOR REVIEW PRIOR TO FABRICATION, DELIVERY, OR INSTALLATION <br />3. LATERAL LOADING <br />WIND CRITERIA: TORNADO WIND SPEED -WA <br />BASIC WIND SPEED =140 MPH <br />EXPOSURE CATEGORY =C <br />INTERNAL PRESSURE COEFFKAENT = +/- 0.18 (ENCLOSED) <br />SEISMIC CRITERIA <br />SITE CUSS =D <br />SEISMIC DESIGN CATEGORY =A <br />4. EARTH PRESSURE LOADING: <br />ALLOWABLE SOIL BEARING CAPACITY <br />TOTAL LOADS (INCLUDING WIND 8 SEISMAL:) =2000 PSF <br />LATERAL EARTH EQUIVALENT FLUID PRESSURE <br />WALLS UNBRACED AT TOP =40 PCF <br />WALL BRACED AT TOP =55 PCF <br />5. GUARDRAILIHANDRAIL LOADING: <br />ALL GUAFOMR41-MDRAILS SHALL MEET 200 LBS (MINIMUM) CONCENTRATED FORCE APPLIED <br />IN ANY DIRECTION. IN -FILL COMPONENTS OF GUARDRAIL SHALL MEET 50 PSF. THESE LOADS <br />ARE TO BE EVALUATED INDEPENDENTLY AND ARE NOT TO ACT CONCURRENTLY WITH ANY <br />OTHER LIVE LOAD. IO DEFLECTN OF GUARDRAIL SHALL MEET THE CRITERIA SET FORTH BY THE <br />INTERNATIONAL CODE COUNCIL EVALUATION SERVICES (ACC -ES) AC 273 -'ACCEPTANCE <br />CRITERIA FOR HANDRAILS AND GUARDS! <br />CONCRETE NOTES: <br />1. STRUCTURAL CONCRETE HAS BEEN DESIGNED IN ACCORDANCE PER ACI 332'RESIDENTIAL <br />CODE REQUIREMENTS FOR STRUCTURAL CONCRETE'. <br />2. CONCRETE PRODUCTION AND PLACEMENT SHALL CONFORM TO THE REQUIREMENTS OF ACI 332 <br />'RESIDENTIAL CODE REQUIREMENTS FOR STRUCTURAL CONCRETE' EXCEPT AS MODIFIED BY <br />STRUCTURAL REQUIREMENTS NOTED ON THE DRAWINGS. <br />3. CEMENT SHALL CONFORM TO ASTM C150'SPECIFICATION FOR PORTLAND CEMENT.' CONCRETE <br />SHALL BE NORMAL WEIGHT, UNLESS INDICATED OTHERWISE. <br />4. CONCRETE AGGREGATES SHALL CONFORM TO ASTM C33'SPECIFICATION FOR CONCRETE <br />AGGREGATES.' <br />5. REINFORCING SHALL CONFORM TO ASTM A-615 GRADE 60. <br />6. REINFORCEMENT SHALL BE FABRICATED AND ERECTED ACCORDING TO THE ACI STANDARDS: <br />"DETAILS AND DETAILING OF CONCRETE REINFORCEMENT', ACI 315 - AND'MANUAL OF <br />ENGINEERING AND PLACING DRAWINGS FOR REINFORCED CONCRETE STRUCTURES', AC1315R. <br />7. REINFORCING STEEL AND WELDED WIRE FABRIC SHALL BE PLACED WITH MINIMUM CONCRETE <br />COVER AND TOLERANCES AS FOLLOWS: <br />SLAB M4WAM WITHIN UPPER 213 OF SLAB AND 3/4' MINIMUM COVER AT INTERIOR <br />CONDITIONS; I-M' MINIMUM COVER AT EXTERIOR CONDITIONS <br />CONCRETE SIOLIDAW" AGADW EARTH! 3- <br />FOFAM OONC ETA 1.12" (I5 REBAR OR SMALLER) 2- (N6 REBAR OR LARGER) <br />TOLERANCE: +/-3/8- <br />8. REINFORCING STEEL SHALL NOT BE CUT, BENT OR STRAIGHTENED IN THE FIELD UNLESS <br />APPROVED BY THE STRUCTURAL ENGINEER OR AS INDICATED ON THE DRAWINGS. <br />9. WELDING OF REINFORCING STEEL IS PROHIBITED UNLESS SPECIFICALLY DETAILED. WELDING <br />WHERE DETAILED SHALL CONFORM TO AWS DI A SPECIFICATION. <br />CONCRETE NOTES (CONTINUED): <br />10. CONCRETE SHALL HAVE A MINIMUM 28-DAY COMPRESSIVE STRENGTH AS FOLLOWS: <br />FOUNDATIONS 6 FOUNDATION WALLS: 2500 PSI <br />SLAB -ON -GRADE 5 CONCRETE BEAMS: 25M PSI <br />11. CONTRACTOR SHALL TIE REINFORCING STEEL SECURELY IN PLACE PRIOR TO PLACING <br />CONCRETE AND PROVIDE SUFFICIENT SUPPORTS TO MAINTAIN THEIR POSITION WITHIN <br />SPECIFIED TOLERANCES DURING ALL CONSTRUCTION ACTIVITIES. INSERTING DOWELS INTO <br />WET CONCRETE IS NOT PERMITTED. ANCHOR RODS AND STEEL INSERTS SHALL BE SET BY <br />TEMPLATE TO WITHIN A 1/8• TOLERANCE IN ANY DIRECTION WITH MINIMUM EMBEDMENT AND <br />EXACT PROJECTION INDICATED ON THE DRAWINGS, PRIOR TO PLACING CONCRETE. <br />12. HOOKED BARS SHALL BE STANDARD 90 DEGREE HOOKS PER ACI UNLESS NOTED OTHERWISE ON <br />THE DRAWINGS. MINIMUM LAP SPLICE SHALL BE CLASS B PER ACI 31 S. LOCATION OF LAP <br />SPLICES SHALL BE AS INDICATED ON CONSTRUCTION DOCUMENTS. <br />13. DOWELS INTO FOUNDATION SHALL MATCH SIZE AND SPACING OF VERTICAL REINFORCEMENT AT <br />ALL COLUMNS, PIERS AND WALLS. UNLESS OTHERWISE NOTED, <br />14. CONTRACTOR SHALL OBTAIN APPROVAL PRIOR TO PLACING OPENINGS OR SLEEVES NOT SHOWN <br />ON THE DRAWINGS, THROUGH ANY STRUCTURAL MEMBER. <br />I S. ONE OF THE FOLLOWING CONCRETE SLAB ON GRADE CRACK CONTROL METHODS SHALL BE <br />USED (CONTRACTOR PREFERENCE): <br />• CONTROL JOINTS: SHALL BE FORMED, SAWED, OR TOOLED TO A 1" MINBAUM DEPTH WITHIN <br />24 HOURS OF CONCRETE PLACEMENT. MAXIMUM JOINT SPACING FOR UNREINFORCED SLAB <br />IS AS FOLLOWS: <br />3-1/2' SLAB: 8 FEET O.C. EACH DIRECTION <br />4' SLAB: 10 FEET O.C. EACH DIRECTION <br />• WELDED WIRE FABRIC (W.W.F.) 6X6-W1.4XW1.4. WELDED WIRE FABRIC SHALL BE FURNISHED IN <br />FLAT SHEETS (ROLLS NOT PERMITTED) AND SHALL CONFORM TO ASTM A-1064 AND HAVE A <br />MINIMUM SIDE AND END LAP OF 8 INCHES. <br />• MICRO- OR MACRO- SYNTHETIC FIBER REINFORCEMENT <br />FIBER LENGTHS SHALL BE 1/2'TO 2-1/4" IN LENGTH. DOSAGE AMOUNT SHALL BE FROM 3/4 TO <br />3.0 POUNDS IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. SYNTHETIC <br />FIBERS SHALL COMPLY WITH ASTM C1116. THE MANUFACTURERBUPPLIER SHALL PROVIDE <br />CERTIFICATION OF COMPLIANCE WITH ASTM CI 116 WHEN REQUESTED BY THE BUILDING <br />OFFICIAL. <br />16. CONTROL JOINTS SHALL BE FURNISHED WITH A FULL-LENGTH KEYWAY CENTERED ON MEMBERS. <br />WHERE THE SIZE OF KEY IS NOT SHOWN ON THE DRAWINGS, THE KEY SHALL BE 25% OF THE <br />CROSS-SECTION DIMENSION OF THE MEMBER AND MINIMUM 1-1/2 INCHES INTO THE FIRST POUR <br />OF CONCRETE. <br />17. PROVIDE POCKETS OR RECESSES IN CONCRETE WORK FOR COLUMNS AND BEAMS AS REQUIRED <br />EVEN IF NOT SHOWN ON THE DRAWINGS. PROVIDE CONCRETE FILL AFTER BEAM ERECTION. <br />IS. CURING OF CONCRETE SURFACES SHALL CONFORM TO ACI 3W.1 'STANDARD SPECIFICATION <br />FOR CONCRETE CURING' AHD ACI 308R'WIDE TO CURING CONCRETE". <br />FOUNDATION NOTES: <br />1. CONTRACTOR SHALL VERIFY ALL CONDITIONS, INCLUDING UNDERGROUND UTILITIES AND FIELD <br />MEASUREMENTS AT JOB SITE AND REPORT ANY DISCREPANCIES TO OWNERS REPRESENTATIVE. <br />2. TOP OF SPREAD FOOTING ELEVATIONS NOTED ON PLAN ARE MINIMUM ELEVATIONS. IN ALL CASES <br />FOOTINGS ARE TO BEAR ON UNDISTURBED NATURAL SOILS OR ENGINEERED FILL HAVING A <br />MINIMUM NET ALLOWABLE BEARING CAPACITY OF 2000 PSF. <br />3. SIDES OF FOUNDATIONS SHALL BE FORMED UNLESS CONDITIONS PERMIT EARTH FORMING. <br />FOUNDATIONS POURED AGAINST THE EARTH REQUIRED THE FOLLOWING PRECAUTIONS: SLOPE <br />SIDES OF EXCAVATIONS AS APPROVED BY GEOTECHNICAL ENGINEER AND CLEAN UP SLOUGHING <br />BEFORE AND DURING CONCRETE PLACEMENT. PROVIDE POLYETHYLENE VAPOR RETARDER <br />COMPLYING WITH GOVERNING BUILDING CODE LISTED ON THIS SHEET AGAINST SOILS WHERE <br />CONCRETE IS TO BE PLACED; LAP ALL EDGES 61NCH (MINIMUM) AND SEAL WITH ADHESIVE. <br />4. WHERE FOOTING STEPS ARE NECESSARY, THEY SHALL BE NO STEEPER THAN ONE VERTICAL TO <br />TWO HORIZONTAL UN.O. <br />5. FOOTINGS SHALL BE CENTERED UNDER COLUMNS AND WALLS UNLESS SPECIFICALLY DETAILED <br />OTHERWISE ON THE DRAWINGS. <br />6. NO FOOTINGS OR SLABS SHALL BE PLACED ON OR AGAINST SUB -GRADE CONTAINING FREE <br />WATER, FROST OR ICE. SHOULD WATER OR FROST, HOWEVER SLIGHT, ENTER A FOOTING <br />EXCAVATION AFTER SUB -GRADE APPROVAL, THE SUB -GRADE SHALL BE REINSPECTED BY THE <br />GEOTECHNICAL ENGINEER TESTING LABORATORY AFTER REMOVAL OF WATER OR FROST. <br />7. CONTRACTOR SHALL FURNISH ALL REQUIRED DE -WATERING EQUIPMENT TO MAINTAIN A DRY <br />EXCAVATION UNTIL BACKFILL IS COMPLETE. <br />8. A GEOTECHNICAL ENGINEER REGISTERED N THE STATE OF WORK PERFORMED SHALL INSPECT <br />THE CONDITION AND ASSURE THE ADEQUACY OF ALL SITE PREPARATION, SUBGRADES, FILLS, <br />BACKFILLS BEFORE PLACEMENT OF FOUNDATIONS, FOOTINGS. SLABS AND WALLS. HE SHALL <br />SUBMIT REPORT TO THE ARCHITECT/ENGINEER DESCRIBING HIS INVESTIGATIONS OF ANY <br />NON -CONFORMING WORK <br />BACI(FILLING: <br />1. DO NOT PLACE BACKFILL AGAINST FOUNDATION WALLS - DESIGNED AS SUPPORTED AT TOP AND <br />BOTTOM - UNTIL BASEMENT LEVEL AND FIRST FLOOR SYSTEM ARE IN PLACE. SHORE AND/OR <br />BRACE WALLS AS REQUIRED IF BACKFIW NG OPERATIONS ARE TO BE CARRIED OUT PRIOR TO <br />PLACEMENT OF FLOOR SYSTEM. <br />2. WHERE BACKFILL IS TO BE PLACED ON BOTH SIDES OF FOUNDATION WALLS, PROVIDE A <br />BALANCED BACKFILL AGAINST FOUNDATION WALLS TO ELIMINATE LATERAL LOAD EFFECTS, OR <br />PROVIDE NECESSARY TEMPORARY LATERAL SUPPORT TO THE TOP OF THE WALL UNTIL <br />PERMANENT SUPPORT IS INSTALLED. <br />3. BACKFILL MATERIAL SHALL L CONSIST OF CLEAN, WELL GRADE GRANULAR SOILS, FREE OF <br />ORGANIC MATERIAL AND BE COMPACTED TO 95% OF MAXIMUM DENSITY, AS DETERMINED BY <br />THE MODIFIED PROCTOR METHOD (ASTM D1557), IN LIFTS NOT EXCEEDING 8INCHES. <br />MASONRY NOTES: <br />1. CONCRETE MASONRY HAS BEEN DESIGNED IN ACCORDANCE WITH ACI 530, 'BUILDING CODE <br />REQUIREMENTS FOR MASONRY STRUCTURES' AND SHALL BE CONSTRUCTED IN ACCORDANCE <br />WITH ACI 530.1, -SPECIFICATIONS FOR MASONRY STRUCTURES.- <br />2. CONCRETE MASONRY SHALL CONFORM TO ASTM C90 AND HAVE A MINIMUM COMPRESSIVE <br />STRENGTH FM - 1,500 PSI U.O.N. MASONRY SHALL HAVE A TEXTURE SUITABLE FOR STUCCO <br />APPLICATIONS WHERE ARCHITECTURAL DRAWINGS INDICATE STUCCO APPLICATION. <br />3. CONCRETE MASONRY UNITS SHALL BE LAID IN RUNNING BOND. <br />4. MORTAR FOR ALL MASONRY SHALL CONFORM TO ASTM C270 WITH MINIMUM COMPRESSIVE <br />STRENGTH OF 2.000 PSI. MORTAR BELOW GRADE SHALL BE TYPE M. ELSEWHERE MORTAR MAY <br />BE EITHER TYPE M OR S UNLESS SPECIFICALLY INDICATED OTHERWISE. USE EITHER PORTIAND <br />CEMENT/UME OR MASONRY CEMENT FOR MORTAR. <br />5. GROUT SHALL CONFORM TO ASTM C476 WITH MINIMUM 28-DAY COMPRESSIVE STRENGTH OF <br />2,500 PSI. <br />6. STEEL BAR REINFORCEMENT SHALL CONFORM TO ASTM A615, GRADE 60. <br />7. VERTICAL CELLS CONTAINING REINFORCING AND GROUT SHALL FORM A CONTINUOUS CAVITY, <br />FREE OF MORTAR DROPPINGS. <br />S. VERTICAL CMU WALL REINFORCING SHALL BE AS NOTED ON THE DRAWINGS. DOWELS TO <br />CONCRETE FOUNDATION TO MATCH SIZE AND SPACING OF VERTICAL REINFORCING UNLESS <br />NOTED OTHERWISE. REINFORCE CMU CORE AT CORNERS, EACH SIDE OF CONTROL JOINTS AND <br />EACH SIDE OF WALL OPENINGS WITH (1)45 CONTINUOUS VERTICAL REINFORCING BARS.. <br />9. HORIZONTAL BOND BEAM AND VERTICAL REINFORCING SHALL BE CONTINUOUS U.O.N. LAP <br />SPLICE REINFORCING PER THE SCHEDULE OR USE MECHANICAL SPLICES ADEQUATE FOR 125% <br />OF SPECIFIED YIELD STRENGTH OF THE BAR. LAP VERTICAL REINFORCEMENT WITH MINIMUM <br />DOWELS OF SAME SIZE AND SPACING THAT HAVE BEEN PREVIOUSLY INSTALLED IN THE <br />FOUNDATIONS. DOWEL EMBEDMENT IN CONCRETE SWILL CONFORM TO THE REQUIREMENTS OF <br />THE CONCRETE NOTES. <br />BAR SIZE <br />LAP SPLICE LENGTH <br />BEND DIAMETER <br />ACI HOOK <br />f4 <br />2W <br />3' <br />1(y <br />I5 <br />1. <br />33/4' <br />10• <br />#6 <br />31' <br />4-1/2' <br />111 <br />MASONRY NOTES (CONTINUED): <br />10. REINFORCING BARS SHALL BE HELD IN POSITION BY WIRE TIES OR OTHER APPROVED MEANS TO <br />ENSURE DESIGN LOCATION AND LAP. PUCE BARS AND LAP PRIOR TO GROUTING. <br />11. GROUTING OF MASONRY WALLS SHALL CONFORM TO RECOMMENDED PROCEDURE FOR 'LOW <br />LIFT GROUTING' GR I N GH LIFT GROUTING' AS OUTLINED IN THE NCMA-TEK 32A -GROUTING <br />FOR CONCRETE MASONRY WALLS AND ACI 530/ASCE 5 SPECIFICATION FOR MASONRY <br />STRUCTURES. GROUT LIFTS SHALL NOT EXCEED 5 FEET WITHOUT MECHANICALLY <br />CONSOLIDATED (VIBRATED) GROUT POURS. <br />12. LIFTS OF GROUT SHALL BE KEYED 4 INCHES INTO THE PREVIOUS COURSE OF MASONRY BELOW. <br />13. MASONRY BELOW GRADE SHALL BE GROUTED SOLID. <br />14. CONTRACTOR SHALL BRACE MASONRY WALLS TO RESIST WIND LOADS UNTIL FLOORS AND <br />ROOFS ARE IN PLACE. AND THE MASONRY HAS REACHED 75% OF THE REQUIRED STRENGTH FM. <br />BRACING SHALL BE PROVIDED IN ACCORDANCE WITH OSHA - CONSTRUCTION SAFETY <br />STANDARDS FOR MASONRY WALL BRACING AND NCMA TEK 34B -'BRACING CONCRETE <br />MASONRY WALLS DURING aMSTRUCT1ON.' <br />WOOD FRAMING NOTES: <br />1. STRUCTURAL SAWN LUMBER, STRUCTURAL COMPOSITE LUMBER, AND CONNECTIONS HAVE <br />BEEN DESIGNED IN ACCORDANCE WITH THE'NATIONALDESIGN SPECIFICATION FOR WOOD <br />CONSTRUCTION.' (ADS) <br />2. PLYWOOD HAS BEEN DESIGNED IN ACCORDANCE WITH "PANEL DESIGN SPECIFICATION.' AND <br />SHALL CONFORM TO 'VOLUNTARY PRODUCT STANDARD PSI CONSTRUCTION AND INDUSTRIAL <br />PLYWOOD.' <br />3. ORIENTED STRAND BOARD (OSB) SHALL CONFORM TO -VOLUNTARY PRODUCT STANDARD PS2 <br />PERFORMANCE STANDARD FOR WOOD43ASM STRUCTURAL -USE PANELS'. <br />4. ALL BEAMS AND HEADERS SHALL BE M-PLY U.N.O. <br />5. WOOD SILL PLATES AND WOOD WALLS SUPPORTED ON CONTINUOUS CONCRETE OR MASONRY <br />SHALL L BE ANCHORED WITH 1/2• DIAMETER CAST -IN -PLACE ANCHOR BOLTS WITH 7" EMBEDMENT, <br />4" (MINIMUM) AND 12' (MAXIMUM) FROM END OF SILL PLATE(S), LOCATED WITHIN THE MIDDLE <br />THIRD OF THE SILL PLATE, WITH NUT AND 3"4"4.229- WASHERS AT THE ANCHOR SPACING <br />BELOW: <br />MAXIMUM ANCHOR BOLT SPACING - 2-0' O.C. <br />REFER TO'PRE-APPROVED FIELD REPAIR NOTES' SECTION FOR ALTERNATE ANCHORAGE <br />APPROVALS. FOR OTHER ANCHORS NOT LISTED, SUBMIT TO ENGINEER OR RECORD FOR <br />REVIEW. <br />6. ALL LUMBER IN CONTACT WITH EARTH, CONCRETE, OR MASONRY - AND WOOD BEAMS <br />POCKETING INTO CONCRETE OR MASONRY WALLS HAVING CLEARANCES LESS THAN 112' ON <br />TOP, SIDES, AND END(S) SHALL BE PRESSURE TREATED OR SEPARATED WITH AN IMPERVIOUS <br />MOISTURE BARRIER. <br />7. STRUCTURAL SAWN LUMBER SHALL BE SPRUCE-PINEf1R NO.1 NO.2 OR BETTER U.N.O. WITH <br />BASE DESIGN VALUES: <br />Fs= 875 PSI Fc� = 425 PSI FT = 450 PSI Fc= 1150 PSI Fv= 135 PSI E= 1400 KSI <br />WITH THE MOISTURE CONTENT OF THE WOOD IN SERVICE WILL NOT EXCEED 19%. <br />8. BEARING AND EXTERIOR WALL STUDS SHALL BE CAPPED WITH DOUBLE (2)9 TOP PLATES <br />INSTALLED TO PROVIDE OVERLAPPING AT CORNERS AND AT INTERSECTIONS. END JOINTS N <br />DOUBLE (2)) TOP PLATES SHALL BE OFFSET AT LEAST 24 INCHES AND SHALL BE NAILED WITH <br />NOT LESS THAN (8)-0.162'x2-1 /2" FACE NAILS ON EACH SIDE THE JOINT. DOUBLE (2X) TOP PLATES <br />OF EXTERIOR WALLS AND INTERIOR LOAD BEARING WALLS SHOWN ON DRAWINGS SHALL BE <br />SOUTHERN YELLOW PINE NO.2 OR BETTER WITH BASE DESIGN VALUES: <br />FB- 1100 PSI Fes= 565 PSI FT= 675 PSI Fc- 1450 PSI FV= 175 PSI E- 1400 KSI <br />WITH THE MOISTURE CONTENT OF THE WOOD IN SERVICE WILL NOT EXCEED 19%. <br />9. STRUCTURAL COMPOSITE LUMBER SHALL CONFORM TO ASTM D 5456 WITH THE FOLLOWING <br />ALLOWABLE DESIGN STRESSES <br />MKWA LLAM LA PAIW.LAM PSL (') 71!31117PA D L8L <br />E - 2000 KSI E - 1 SDO KSI E - 1300 KSI <br />F, - 26M PSI F, - 2400 PSI FB - 1700 PSI <br />(ry - EOOZER BEAM 2.1 E' ARE AN ACCEPTED ALTERNATE TO PSL COLUMNS SPECIFIED <br />ON PLANS PROVIDED THE 130OZER BEAM 2.1 E IS OF EQUAL OR GREATER SECTION <br />DIMENSION TO THE PSL COLUMN AND OF EQUAL OR LESSER HEIGHT <br />10. FLOOR SHEATHING SHALL BE 23132 INCH, APA RATED SHEATHING, 48/24 MIN., EXPOSURE 1. <br />INSTALL WITH THE LONG DIMENSION OR STRENGTH AXIS OF THE PANEL ACROSS SUPPORTS <br />AND WITH PANEL CONTINUOUS OVER TWO OR MORE SPANS. PANEL EDGES SHALL BE <br />TONGUE -AND -GROOVE. FLOOR SHEATHING SHALL BE GLUED AND NAILED TO SUPPORTING <br />MEMBERS. ADHESIVE SHALL MEET APA SPECIFICATION AFG.01, APPLIED IN ACCORDANCE WITH <br />THE MANUFACTURER'S RECOMMENDATIONS. PROVIDE 0.131N2.112" COMMON NAILS AT 6INCH <br />O.0 ALONG SUPPORTED PANEL EDGES AND 12 INCH O.0 AT INTERMEDIATE SUPPORTS. <br />11. FOR INTERIOR WALL HEADERS PROVIDE (1)-2X JACK STUD AND (1)-2X KING STUD U.N.O. ON <br />DRAWINGS. <br />12. FOR EXTERIOR WALL HEADERS PROVIDE (1)-2x JACK STUD AND (1)-2x KING STUD, MINIMUM, <br />REFER TO CHART BELOW U.N.O ON DRAWINGS: <br />WINDSPEED OF <br /><= 140 EXP. C <br />WALL HEIGHT <br />OFT <br />9FT <br />10FT <br />STUD <br />SIZE <br />HEADER SPAN <br />(FT) <br />4 <br />1J/1K <br />1J/1K <br />1J/1K <br />6 <br />1J/1K <br />1J11K <br />1J12K <br />8 <br />1J/1K <br />1J12K <br />1J13K <br />10 <br />1J2K <br />1J2K <br />1J/4K <br />2c4 <br />12 <br />1J/2K <br />1J13K <br />1J/4K <br />14 <br />1J/2K <br />1J/4K <br />ENG <br />16 <br />1J13K <br />1J/4K <br />ENG <br />18 <br />1J/3K <br />ENG <br />ENG <br />WIN SPEED OF <br /><= 140 EXP. C <br />WALL HEIGHT <br />OFT <br />9FT <br />1OFT <br />STUD <br />SIZE <br />HEADER SPAN <br />(FT) <br />4 <br />1J/1K <br />1J/1K <br />1J/1K <br />6 <br />1J/1K <br />1J/1K <br />iJ/1K <br />8 <br />1J/1K <br />1J/1K <br />1J/1K <br />10 <br />1J/1K <br />1J/1K <br />1J/1K <br />2.6 <br />12 <br />1J/1K <br />iJ/1K <br />1J/1K <br />14 <br />1J/1K <br />1J/1K <br />IJ/1K <br />16 <br />1J/1K <br />1J/1K <br />1J/1K <br />18 <br />1J/1K <br />1J/1K <br />1J/1K <br />13. WALLS SHOWN ON THE FRAMING PLANS ARE LOAD BEARING WALLS; WALLS NOT SHOWN ON <br />STRUCTURAL FRAMING PLANS ARE INTERIOR NON -LOADING BEARING PARTITION WAILS. <br />14. LOAD BEARING WALLS SHALL BE CONSTRUCTED WITH 2X STUDS AT 16" O.C. MAXIMUM U.N.O. <br />NON -LOAD BEARING PARTITION WALLS SHALL BE CONSTRUCTED WITH 2X OR METAL STUDS (IS <br />GA MIN.) 0 24' O.C. MAXIMUM. <br />15. STUD COLUMNS UNDER LOAD BEARING POINTS OF GIRDERS/BEAMS SHALL MATCH THE <br />GIRDER/BEAM PLY COUNT WITHIN 12' TOLERANCE (2-PLY STUD COLUMN MINIMUM). SOLID <br />BLOCK ALL GIRDER/BEAMS THRU FLOOR SYSTEMS AND TO THE FOUNDATION. <br />16. WHEN NOT SHOWN ON DRAWINGS OR DETAILS, THE NAILING SCHEDULE FOR WOOD FRAMING <br />ELEMENTS SHALL COMPLY WITH THE IRC TABLE R802.3(1). <br />17. FLOOR SYSTEMS ARE DESIGNED BY THE TRUSS AND/OR WOOD 4 JOIST MANUFACTURER'S <br />DELEGATED ENGINEER AND BE IN CONFORMANCE WITH THE LOADS 8 DEFLECTIONS IDENTIFIED <br />IN THE DESIGN CRITERIA NOTES SECTION. INSTALL PER MANUFACTURERS RECOMMENDATIONS, <br />NOTES, AND DETAILS. FLOOR FRAMING CONCEPT LAYOUTS SHOWN WITHIN THE DRAWINGS ARE <br />FOR ILLUSTRATIVE PURPOSES ONLY TO DEPICT FLOOR SYSTEM -TO -WALL CONNECTIONS. <br />CHANGES TO THE CONCEPTUAL FLOOR LAYOUT SHOWN IS NOT PERMITTED WITHOUT A LETTER <br />AND REVIEW FROM THE ENGINEER OF RECORD. PREFABRICATED WOOD I -MIST SHALL <br />CONFORM TO ASTM D SM. <br />JURISDICTION SPECIFIC NOTES: <br />1. FOR PARTIALLY ENCLOSED AREAS, INCLUDING BUT NOT LIMITED TO LANAIS, PORCHES, AND <br />BALCONIES A 1/2' (MINIMUM) EXTERIOR GRADE SOFFIT BOARD WITH A CEMENTMOUS <br />KNOCKDOWN FINISH IS ACCEPTABLE PROVIDED THAT IT IS PAINTED MEETING THE <br />REQUIREMENTS OF ASTM C932 TO GIVE THE CEILING WATER RESISTANCE. THE SOFFIT BOARD <br />PRODUCT SHALL BE ATTACHED PER MANUFACTURER SPECIFICATIONS TO BE IN COMPLIANCE <br />WITH R703.1. <br />2. THE SOFFIT DESIGN PRESSURE IS AS NOTED IN THESE DOCUMENTS. WITH KAYCAN VINYL SOFFIT <br />INSTALLED IN ACCORDANCE WITH MANUFACTURERS REQUIRMENTS AND ICGES EVALUATION <br />REPORT ESR-1495 THE SOFFIT WILL COMPLY WITH R703.1. <br />PRE-ENGINEERED ROOF TRUSS NOTES: <br />1. ROOF TRUSS SHOWN ON STRUCTURAL DRAWINGS IN CONCEPTUAL ONLY TO ILLUSTRATE <br />TRUSS -TO WALL CONNECTIONS AND DOES NOT SERVE AS A ROOF TRUSS DESIGN. ROOF <br />TRUSSES SWILL BE DESIGNED AND MANUFACTURED IN CONFORMANCE FOR THE INDICATED <br />LOADS WITH ANSI/TPI 1 'NATIONAL DESIGN STANDARD FOR METAL PLATE CONNECTED WOOD <br />TRUSS CONSTRUCTION.' FINAL PRE-ENGINEERED ROOF TRUSS FRAMING LAYOUT AND DESIGNS <br />TO BE BY ROOF MANUFACTURER'S DELEGATED ENGINEER. <br />2. ROOF TRUSSES SHALL BE DESIGNED FOR THE SUPERIMPOSED LOADS IDENTIFIED IN THE <br />DESIGN CRITERIA NOTES SECTION. <br />3. THIS PLAN IS DEVELOPED FROM THE REVIEW OF MASTER TRUSS FILES. ANY LOT THAT DEVIATES <br />FROM THE MASTER TRUSS FILE ON RECORD,OR FOR PLANS FIELDSTONE AE IS NOT <br />CONTRACTED TO PERFORM TRUSS RENEW ON, THE CONTRACTOR IS RESPONSIBLE TO ASSURE <br />THE DIRECT COMPLIANCE OF TRUSS MANUFACTURER LAYOUT TO THESE DRAWINGS 6 VERIFY <br />ALL TRUSS CONNECTORS ARE SUFFICIENT TO WITHSTAND THE UPLIFT/LATERAL LOADS IMPOSED <br />4. TRUSS MANUFACTURER SHALL PROVIDE HANGERS AND CONNECTIONS ADEQUATE FOR LOADS <br />AT ALL TRUSSTO-TRUSS, TRUSS -TO -BEAM, AND BEAM -TO -TRUSS CONNECTIONS. <br />5. REFER TO ARCHITECTURAL DRAWINGS FOR TRUSS SHAPE, OVERHANG, DIMENSIONS, SLOPES, <br />SPANS, DRAINAGE, BEARING WALL HEIGHTS, ETC. <br />S. THE POSITIONS, WEIGHTS, AND METHODS OF ATTACHMENTS OF ALL MECHANICAL UNITS, <br />ELECTRICAL FIXTURES, PLUMBING, FIRE SPRINKLERS, ETC SIWl BE INCLUDED IN THE DESIGN <br />OF THE TRUSSES BY THE TRUSS MANUFACTURER. SEE ARCHITECTURAL DRAWINGS FOR ATTIC <br />ACCESS SIZE AND LOCATIONS. <br />7. SUPERIMPOSED LOADS FROM SECONDARY FRAMING O.E. SOFFITS, PARAPETS, VALLEY FRAMING, <br />UPPER TRUSSES, ETC) SHALL BE INCLUDED IN THE DESIGN OF SUPPORTING TRUSSES. <br />S. CONTRACTOR TO PROVIDE TRUSS BRACING PER BCSI-W IN ADDITION TO PERMANENT BRACING <br />SHOWN ON THE TRUSS DESIGN PROVIDED BY THE DELEGATED TRUSS ENGINEER. <br />PRE APPROVED FIELD REPAIR NOTES: <br />i. MISPLACED DOWEL REPAIR: THIS NOTE DESCRIBES ALTERNATES TO MITIGATE THE CASTING OF <br />REBAR VERTICAL REINFORCEMENT AT AN INCORRECT LOCATION. <br />IF THE WALL HAS NOT BEEN BUILT: DRILL AND EPDXY #5 REBAR (36" LG.) INTO THE THICKENED <br />EDGE OF SLAB AT THE CORRECT LOCATION. AS WALL IN CONSTRUCTED, LAP REBAR IN <br />ACCORDANCE WITH MASONRY NOTES LAP SCHEDULE, PLACING A HOOKED BAR WITH 12' LAP AT <br />THE TOP OF WALL WITH THE CONTINUOUS REBAR IN THE TIE BEAMMOND BEAM. COMPLETE <br />GROUTING OF WAIL. <br />IF THE WALL HAS ALREADY BEEN BUILT: PRIOR TO GROUT PLACEMENT, OPEN THE WALL AT THE <br />CORRECT LOCATION APPROXIMATELY 16' (H) x 4' (" AT FLOOR LEVEL DRILL AND EPDXY #5 <br />REBAR (32- LG.) INTO THE THICKENED EDGE OF SLAB. LAP VERTICAL REINFORCEMENT IN <br />ACCORDANCE WITH MASONRY NOTES LAP SCHEDUILE. PLACING A HOOKED BAR WITH 12' LAP AT <br />THE TOP OF WALL WITH THE CONTINUOUS REBAR IN THE TIE BEAMMOND BEAM. COMPLETE <br />GROUPING OF WALL. <br />2. MISSINGIMISPLACED ANCHOR BOLT: ALTERNATE SILL PLATE ANCHORAGE SOLUTIONS <br />INTOOONcram <br />A 1/ W TTPEN HD WITH 13/4' MINIMUM EDGE DISTANCE AND 6' MINIMUM END DISTANCE IS A <br />DIRECT 1:1 REPLACEMENT FOR A 1/2" DIAMETER ANCHOR BOLT WITH 7" EMBEDMENT INTO <br />CONCRETE. <br />A 1/2' THREADED ROD SET3G EPDXY 7" EMBEDMENT WITH I-M" MINIMUM EDGE DISTANCE AND <br />7-1/2" MINIMUM END DISTANCE IS A DIRECT 1:1 REPLACEMENT FOR A 1/2' DIAMETER ANCHOR <br />BOLT WITH 7" EMBEDMENT INTO CONCRETE. <br />HTO W01T FLL W MASONRY (QFCW: <br />A 1/2')6' TTTEN HD WITH 13/4" MINIMUM EDGE DISTANCE AND 8' MINIMUM END DISTANCE ATV-8" <br />O.C. REPLACES A 1/2* DIAMETER ANCHOR BOLT WITH 7" EMBEDMENT AT 6-0' O.C.; LIKEWISE A <br />1 MW TITEN HD WITH 13/4' MINIMUM EDGE DISTANCE AND 8" MINIMUM END DISTANCE AT 2-8' <br />O.C. REPLACES A 1/2' DIAMETER ANCHOR BOLT WITH T EMBEDMENT AT W-0' O.C.. <br />3. SIMPSON MASA SILL ANCHORS MAY BE USED AS AN ALTERNATE TO THE ANCHOR BOLTS AND <br />SPACING NOTED HEREIN ACCORDING TO THE FOLLOWING TABLE: <br />BASIC WIND <br />SPEED (MPH) <br />MAXIMUM <br />SPACING <br /><140 <br />6'-0• <br />140 <br />1'-T <br />ISO <br />1'-3" <br />MlcMpan <br />3400 Auburn Rd <br />Suite 200 <br />Aubum Hills, MI 48326 <br />+1 248.622.4035 <br />Florida <br />12906 Tampa Oaks Blvd. <br />Suite 150 <br />Tampa, FL 33637 <br />+1 813.466.3310 <br />www.holdstonwo.com <br />NOTES: <br />1. MASA SPACING BASED ON NO MORE THAN ONE IN THREE INSTALLED WITH ONE LEG <br />INSTALLED VERTICALLY ATTACHED TO STUD <br />4. MISSINGMISPIACED TRUSS STRAP ANCHOR: REFER TO'MISSED TRUSS STRAP REPAIR' DETAIL <br />WITHIN DRAWINGS. <br />FOR MISLOCATED TRUSS ANCHORS WHICH ARE GREATER THAN 1/e' BUT LESS THAN 1-12' FROM <br />THE FACE OF THE TRUSS, A SHIM SHALL BE PROVIDED AND NAIL LENGTH INCREASED TO <br />PENETRATE THROUGH BOTH PLYS OF MATERIAL (I.E. 3' LG. NAILS). WHEN GAP IS GREATER TOWN <br />1-12', INSTALL NEW ANCHORS. <br />5. MASONRY WALL OVERHANGING SUB <br />SLOCK WBHANO I11~ <br />< 5/8' NO REPAIR REOD <br />5/8' < OVERHANG < 1.12' GROUT SOLID BOTTOM 3 COURSES OF AFFECTED WALL LENGTH <br />> 142' CONTACT ENGINEER OF RECORD FOR REPAIR <br />6. NOTCHED TOP PLATES 8 STUDS REOUIRNG REPAIR <br />AT STUD& STRUCTURAL REPAIR IS REQUIRED AT STUDS WHEN A STUD IS NOTCHED TO A DEPTH <br />GREATER THAN 25%OF THE WIDTH IN BEARING WALLS, OR 40% IN NON -LOAD BEARING WALLS; r <br />OR WHEN A HOLE IS DRILLEDIBORED TO A DIAMETER EXCEEDING 40%OF THE STUD WIDTH N <br />BEARING WALLS, OR 60%OF THE STUD WIDTH IN NON -BEARING WALLS. IF THE MAXIMUM , <br />HOLENOTCH SPECIFICATIONS ARE EXCEEDED THEN A STUD SHOE MUST BE INSTALLED. STUD <br />SHOE REPAIRS ARE AS FOLLOWS: FOR 2X STUD USE HSS2SDS1.5 WITH (12)-1/4'X1-12' SOS <br />SCREWS. FOR MULTIPLY 2X STUDS USE HSS2-'Y'SDS3 WITH (12)-1/4'X3- SDS SCREWS, WHERE <br />'#" CORRESPONDS TO THE NUMBER OF STUDS IN THE MULTI -PLY. <br />AT 70P PLATLB: A HOLE, CUT, OR NOTCH THAT IS GREATER THAN 50% OF THE PLATE WIDTH IS <br />REMOVED FOR PIPING (EXCEPT WHEN THE SIDE OF THE WALL WITH THE NOTCH OR CUT IS <br />COVERED BY WOOD STRUCTURAL PANEL SHEATHING), OR THE PLATES ARE CUT THROUGH. THE <br />REQUIRED REPAIR IS A GALVANIZED 16-GAUGE METAL TIE THAT IS AT LEAST 1-12' WIDE AND <br />MUST BE FASTENED WITH (8)-16D NAILS ON EACH SIDE OF THE OPENING. <br />O0OOFieldstone <br />�� `0%%% 1111fill,/ <br />�pMl h� �•,,� <br />�,. <br />C.OA.# ARCHITECURE: <br />��� �N <br />AA26002802 <br />C.O.E.# ENGINEERING: <br />No. 860 <br />29349 <br />O IBRAHEM ELAYEB, PE <br />P.E.# 91476 <br />'• (V <br />% OF !p� <br />■ BENJAMIN NIESE, PE <br />P.E.# 86025 <br />O <br />05 24 <br />''�OHAL <br />ATE 1­1AFFN F, F, Ta N, • <br />SWAT <br />L J <br />DRAWN BY: I FAE <br />VERSION: 5.0 <br />SHEET NAME <br />COVER SHEET <br />SHEET N <br />SO.1-140, <br />