Laserfiche WebLink
MODULE SPECIFICATION <br />MODULE MAKE <br />SONALI <br />MODULE MODEL <br />SS-M-390 <br />FSEC CERTIFICATION <br />PMAX (STC) <br />390 <br />W <br />VOC (STC) <br />36.81 <br />V <br />VMPP (STC) <br />30.22 <br />V <br />ISC (STC) <br />13.62 <br />A <br />IMPP (STC) <br />12.91 <br />A <br />NOCT <br />43 <br />C <br />TC ISC <br />0.05 <br />%/K <br />TC VOC <br />-0.29 <br />%/K <br />TC PMPP <br />-0.37 <br />%/K <br />OPERATING TEMP, <br />-40-+85 <br />C <br />SAFETY LABELS AND MARKINGS GENERAL NOTES: <br />1. EQUIPMENT SUCH AS INVERTERS AND SOLAR MODULES HAVE <br />PRE -APPLIED LABELS FOUND HEREIN SHALL BE APPLIED TO SUCH <br />EQUIPMENT FOR INFORMATIONAL PURPOSES. <br />2. LABELS AND MARKINGS SHALL BE APPLIED TO COMPONENTS IN <br />ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF NEC. <br />3. ALL REQUIRED PRODUCT SAFETY AND WARNING SIGNAGE SHALL BE UV <br />RESISTANT OUTDOOR -RATED LAMINATED VINYL IN ACCORDANCE WITH <br />ANSI Z535.4-2011. <br />4. ALL LABELS SHALL BE REFLECTIVE PER NFPA 11.12 <br />SAFETY LABELS AND MARKINGS LEGEND <br />A. LOCATION OF SERVICE DISCONNECTING MEANS. APPLY TO MAIN <br />SERVICE DISCONNECTING MEANS AND PV DISCONNECTING MEANS AT <br />POCC. <br />MAIN SERVICE DISCONNECT MARKING <br />A LABEL SHALL BE PERMANENTLY AFFIXED TO THE MAIN SERVICE <br />DISCONNECT PANEL SERVING ALTERNATING CURRENT (AC) AND DIRECT <br />CURRENT (DC) PHOTOVOLTAIC SYSTEMS. THE LABEL SHALL BE RED WITH <br />WHITE CAPITAL LETTERS AT LEAST 3/4 IN. IN HEIGHT AND IN A <br />NONSERIF FONT, TO READ: "WARNING: PHOTOVOLTAIC POWER SOURCE." <br />THE MATERIALS USED FOR THE LABEL SHALL BE REFLECTIVE, WEATHER <br />RESISTANT, AND SUITABLE FOR THE ENVIRONMENT. <br />RAPID SHUTDOWN MEANS MARKING <br />A PERMANENT LABEL SHALL BE AFFIXED ADJACENT TO THE CIRCUIT <br />DISCONNECTING MEANS SERVING AC AND DC PHOTOVOLTAIC SYSTEMS. <br />THE LABEL SHALL HAVE BE REFLECTIVE WITH ALL LETTERS CAPITALIZED <br />AND HAVING A MINIMUM HEIGHT OF 3/8", IN A BLACK ON YELLOW <br />BACKGROUND FOR THE FIRST LINE, THE REAMING TEXT MUST BE <br />UPPERCASE AT LEAST 3/16" HIGH IN BLACK ON WHITE BACKGROUND. <br />THE LABEL SHALL BE CONSTRUCTED OF DURABLE ADHESIVE MATERIAL <br />OR OTHER APPROVED MATERIAL. <br />INVERTER SPECIFICATION <br />INVERTER MAKE <br />ENPHASE <br />INVERTER MODEL <br />IQ8PLUS-72-2-US <br />MAX AC POWER OUTPUT <br />300 <br />VA <br />MAX. INPUT VOLTAGE <br />60 <br />V <br />NOM. DC VOLTAGE @ 240V <br />240 <br />V <br />NOM, AC VOLTAGE <br />25-58 <br />V <br />MAX. CONTINUOUS OUTPUT CURRENT <br />1.21 <br />A <br />MAX. DC CURRENT <br />15,0 <br />A <br />MAX. DC POWER (STC) <br />440 <br />W <br />CEC EFFICIENCY <br />97 <br />% <br />N AN EMERGENCY CONTACT <br />US SOLAR <br />1-800-551-54JO <br />SOLAR PHOTOVOLTAIC SYSTEM <br />Ai <br />-WARNING- <br />AUTHORIZED PERSONNEL ONLY <br />RATED AC CURRENT: 30.3A <br />NOMINAL AC VOLTAGE: 240V <br />LOCATION: MAIN PV PANEL <br />PHOTOVOLTAIC DISCONNECT <br />Ai <br />-WARNING- <br />ELECTRIC SHOCK HAZARD <br />DO NOT TOUCH TERMINALS. TERMINALS ON <br />BOTH THE LINE AND LOAD SIDES MAY BE <br />ENERGIZED IN THE OPEN POSITION. <br />LOCATION: AC DISCONNECTS) <br />NOTES: <br />1. ALL ASPECTS OF THE ELECTRICAL WORK REQUIRED TO COMPLETE THE PROJECT REPRESENTED IN THIS DOCUMENT <br />SHALL COMPLY WITH THE MANUFACTURERS RECOMMENDATIONS/SPECIFICATIONS AND ALL CODES, STATUES AND <br />STANDARDS ADOPTED BY THE STATE AND THE LOCAL AUTHORITY HAVING JURISDICTION. <br />2. ALL COMPONENTS MUST BE GROUNDED PER NEC 690.43, <br />3. ALL EQUIPMENT SHALL BE LISTED PER NEC 690.4(D). <br />4. THE INFORMATION PROVIDED IN THESE DOCUMENTS IS NOT EXHAUSTIVE. IT REMAINS THE CONTRACTORS <br />RESPONSIBILITY TO ACHIEVE THE PROPOSED INSTALLATION, IN FULL EXERCISE OF AND COMPLIANCE WITH THE <br />ITEMS IDENTIFIED IN NOTE 1. <br />5. PER NEC 690.17 PROVIDE A WARNING SIGN AT ALL LOCATIONS WHERE TERMINALS OF THE DISCONNECTING <br />MEANS BE ENERGIZED IN THE OPEN POSITIONS. SIGN SHALL READ "WARNING -ELECTRIC SHOCK HAZARD - DO <br />NOT TOUCH TERMINALS - TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN <br />POSITION OR EQUIVALENT. <br />6. PER NEC 705.10, PROVIDE A PERMANENT PLAQUE OR DIRECTORY SHOWING ALL ELECTRIC POWER SOURCES ON <br />THE PREMISES AT SERVICE ENTRANCE, <br />7. INTERCONNECTION METHOD SHALL COMPLY WITH NEC 705.12. <br />8. PV METER MAY OR MAY NOT BE REQUIRED BY THE AHJ AND/OR UTILITY FOR INTERCONNECTION, <br />9. CONDUCTOR SIZING OF THIS DESIGN IS BASED ON RACEWAYS LOCATED OUTSIDE ATTICS OR NOT EXPOSED <br />TO DIRECT SUNLIGHT. WHERE TWO DIFFERENT AMPACITIES APPLY TO ADJACENT PORTIONS OF A CIRCUIT, THE <br />HIGHER AMPACITY SHALL BE PERMITTED TO BE USED BEYOND THE POINT OF TRANSITION, A DISTANCE EQUAL TO <br />3.OM (10ft) OR 10 PERCENT OF THE CIRCUIT LENGTH FIGURED AT THE HIGHER AMPACITY, WHICH EVER IS LESS. <br />NEC 310A5 (B)(2) <br />10.ALL CONDUCTORS AND RACEWAYS SHALL BE SUPPORTED ON INTERVALS AND BY METHODS REQUIRED BY THE <br />N EC. <br />11. LINE TAPS TO BE MADE WITH ILSCO KUP-L-TAP INSULATION PIERCING CONNECTOR. <br />12. GFI BUILT IN TO ALL INVERTERS. <br />SAFETY LABELS <br />Ai <br />-WARNING- <br />ELECTRIC SHOCK HAZARD. THE DC <br />CONDUCTORS OF THIS PHOTOVOLTAIC <br />SYSTEM ARE UNGROUNDED AND <br />MAY BE ENERGIZED <br />AUTHORIZED PERSONNEL ONLY <br />LOCATION: DISCONNECTS, INVERTERS, <br />JUNCTION BOXES, OTHER ENCLOSES <br />HOLDING DC CONDUCTORS <br />EMERGENCY RESPONDER: <br />THIS SOLAR PV SYSTEM IS <br />EQUIPPED WITH RAPID SHUTDOWN <br />TURN RAPID <br />SHUTDOWN SWITCH TOw <br />v <br />THE 'OFF" POSITION <br />TO SHUT DOWN <br />ENTIRE PV SYSTEM <br />a o y� ri <br />P�.••E NSF. <br />® No. 7479 <br />4 <br />Al� P •�4U <br />��,Q®� <br />D <br />U o I <br />m N C)N <br />Z N <br />m \ N <br />z di z <br />m O¢ cU O <br />v <br />to "2 <br />Z o <br />O � <br />o� <br />O J � <br />co <br />H O <br />WO01) <br />W <br />H U-�CD� <br />N Z CV <br />zclf <br />W „ �— <br />w z <br />o <br />Cl 0- <br />H <br />z <br />D <br />N <br />0 <br />� o <br />O N <br />0 <br />o L�j � <br />u� z <br />Ln <br />Z Of <br />w <br />o 0 <br />U 0- <br />DWG. NO. <br />S-4 <br />