My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6477 Paden Wheel St
Zephyrhills
>
Building Department
>
Building Plans
>
6477 Paden Wheel St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 12:19:40 PM
Creation date
2/19/2025 9:03:43 AM
Metadata
Fields
Template:
Building Plans
Street #
6477
Location
Paden Wheel St
Contractor
Lennar Home LLC
Building Plans - Permit #
18982
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
13 <br />M <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />MAIN <br />0 <br />200 amp <br />150amp <br />NEMA1 <br />200 AMP <br />#14 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2copperto WH <br />#10-3 copper to Dryer <br />or 4/0 SER Alu <br />Bare Cu Ground <br />CLAMP PER 250,50 AND <br />____________________________________J 250.520FTHE 2011 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />8. Carbon Monoxide Protecdon: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />FW.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />FivP <br />HALF -SWITCHED DUPLEX OUTLET <br />I c <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />j <br />WALL SWITCH <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />�D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />7 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />ppl� <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />c� <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />J <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />POWER CO. FEED —� <br />INTERSYSTEM <br />BONDING o <br />TERMINATION PER 71 <br />NEC 08, 250.94 J <br />C/O 3„ <br />-I11 3" VTR <br />r' I I <br />I <br />j-3tr <br />WC WR <br />DBL. 2" TUB <br />SINK <br />III 3" VTR <br />I I I <br />I BL. <br />I I IINK <br />i <br />WC h I �r•� <br />`- -- <br />TUB3r, <br />3 33" 2" <br />III 1.5" VTR <br />FIKITCHEN <br />" art TUB WC <br />NK <br />3" <br />HANSON BOX <br />PLUMBING RISER <br />3" <br />NOTE: PLUMBING RISER IS SCHEMATIC TO SCALE: NTS <br />BE VERIFIED WITH PLUMBER <br />DEDICATED RECEPTACLE GF <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />PENDANT <br />LIGHTS OVER GF` <br />ISLAND <br />G F I 2'-0" 2'-0" � /� � <br />KITCHEN <br />.Ile .�- �• 1 <br />2X4FL. <br />SINK <br />r SWITCH FOR <br />DISPOSAL IN <br />CAB. UNDER SINK <br />OPTIONAL LIGHTING <br />SCALE: %4'=1'-0" <br />W <br />�O❑ <br />U C <br />>Oa <br />PER SPECS ' ' <br />ELECTRICAL PLAN <br />SCALE: %4'=V-0" <br />AC PAD <br />WP DISC. HB <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />r= -===-1 <br />IALT II <br />I AC PAD I <br />I� �I <br />r <br />z M <br />0 <br />— o <br />z� <br />z� <br />Q <br />❑ <br />W <br />N <br />4-J L1j <br />U <br />OLU <br />~ <br />rw <br />C%� = <br />0 <br />o 0 <br />U <br />W <br />r pEp <br />U — <br />d Cl) <br />C to M <br />m`- - <br />O O CN <br />_ <br />U44) <br />rLLC0 <br />C X <br />Q & <br />0)ao <br />to O d' <br />(�N,) Q O <br />A1 <br />D®� <br />N,C 1.1) C <br />N <br />t� co <br />C <br />CN <br />Z Go <br />W aNC6"' <br />aw <br />IW!>=LLo <br />V Q ar$ <br />a <br />� Z <br />ar7� <br />D: <br />_ <br />C N <br />�N�o� <br />NgErnw' <br />ca m <br />m <br />.M <br />Z <br />ILa <br />W NaM <br />OU <br />o <br />U <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />i <br />O <br />O <br />Z r'V <br />0 <br />> U.) M O <br />M <br />av�' <br />o. cn •� d- <br />< C U_ <br />M <br />[1C U M '-' <br />a �� <br />E <br />Z <br />W <br />wLZ <br />LU z <br />,,,M z5t <br />Ut- yo0 <br />0 z Q U <br />Z a OU Q Q <br />i F Z <br />? w <br />�Zo �w <br />g <br />O V <br />0 <br />{— <br />LU N <br />��apZO <br />d• <br />LUIwJ <br />C:) <br />r-I <br />In <br />N <br />eo-\ <br />L1') <br />C <br />J <br />�20¢ <br />LL <br />`J Z <br />Y�p <br /><¢Z00 <br />U.1 <br />0 <br />z <br />Q <br />o0Z <br />1p <br />W°oo5o <br />J> <br />^' J <br />a�Z <br />��0LLZ¢ <br />to <br />1 Q <br />O C) <br />LU <br />N <br />^ <br />Y I <br />o <br />aoza <br />0 <br />� <br />T� �—• <br />¢ a ¢ w <br />a LL <br />ZC:) <br />L.L. <br />~ <br />LL <br />W <br />z <br />J <br />g <br />z <br />W <br />SCALE : AS NOTED <br />PLOT DATE: 12/7/2012 <br />TECH: MJAMES <br />VERSION NO. <br />5oll <br />JOB NO: 17-4139 <br />SHEET NO. <br />3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.