My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6601 Silverado Ranch Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
6601 Silverado Ranch Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 6:36:20 AM
Creation date
2/19/2025 9:03:53 AM
Metadata
Fields
Template:
Building Plans
Street #
6601
Location
Silverado Ranch Blvd
Contractor
Lennar Homes
Building Plans - Permit #
19138
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A <br />a <br />r <br />N <br />O O <br />Florida Statewide Evaluation Report Simpson Florida Statewide Evaluation Report CL <br />USP M -0 0- <br />.� U � N <br />(� cu � <br />= 5 'L <br />C O LL <br />ca 0 � ,0 > <br />.u) -p E (D p <br />O <br />L <br />O <br />U <br />O <br />L <br />v, <br />U m <br />I- <br />O L <br />W <br />a <br />z J <br />z <br />J <br />SHEET NO. <br />PA 1.0 <br />rmi <br />t <br />rIM <br />t <br />rCU <br />t <br />Stock <br />A3 ' <br />Product FL17244.1 <br />ESR-3455 <br />Stock <br />A23 <br />FL10446,2 <br />ESR-2606 <br />HD210-2 <br />FL17232.3 <br />ESR-3445 <br />HU210-2 <br />FL10655.20 <br />ESR-2549 <br />HD212-2 <br />FL17232.3 <br />ESR-3445 <br />HU212-2 <br />FL10655.23 <br />ESR-2549 <br />HD216 <br />FL17232.3 <br />ESR-3445 <br />HU216 <br />FL10655.29 <br />ESR-2549 <br />HD216-3 <br />FL17232.3 <br />ESR-3445 <br />HU216-3 <br />FL10655.29 <br />ESR-2549 <br />HD26 <br />FL17232.2 <br />ESR-3445 <br />HU26 <br />FL10655.31 <br />ESR-2549 <br />HD28-2 <br />FL17232.3 <br />ESR-3445 <br />HU28-2 <br />FL10655.34 <br />ESR-2549 <br />HD410 <br />FL17232.4 <br />ESR-3445 <br />HU410 <br />FL10655.44 <br />ESR-2549 <br />HD412 <br />FL17232.4 <br />ESR-3445 <br />HU412 <br />FL10655.45 <br />ESR-2549 <br />HD610 <br />FL17232.4 <br />ESR-3445 <br />HU610 <br />FL10655.51 <br />ESR-2549 <br />HD0410 <br />FL17241.5 <br />ESR-3444 <br />HUC0410 <br />FL11468.11 <br />SIM200804 <br />HGAIOKT <br />FL17236.6 <br />ESR-3448 <br />HGAIOKT <br />FL11470.4 <br />SIM200803 <br />HGAMIOKT <br />FL17699.1 <br />Evaluation Report <br />HGAMIOKT <br />FL11470.4 <br />SIM200803 <br />HHCP2 <br />FL17236.7 <br />ESR-3448 <br />HCP2 <br />FL10447.2 <br />ESR-2551 <br />HTA16 <br />FL17680.2 <br />Evaluation Report <br />HETA16 <br />FL11473.5 <br />SIM200802 <br />HTA20-18 <br />FL17680.2 <br />Evaluation Report <br />HETA20 <br />FL11473.5 <br />SIM200802 <br />HTT16 <br />FL17324.1 <br />Evaluation Report <br />HTT16 <br />FL11496.1 <br />ES-0130 <br />HTT45 <br />FL17324.1 <br />Evaluation Report <br />HTT22 <br />FL11496.1 <br />ES-0130 <br />HTT4 <br />FL17219.2 <br />ER-0200 <br />HTS16 <br />FL10456.22 <br />ESR-2613 <br />HTT5 <br />FL17219.2 <br />ER-0200 <br />HTS20 <br />FL10456.23 <br />ESR-2613 <br />HTW16 <br />FL17244.8 <br />ESR-3455 <br />HTS24 <br />FL10456.24 <br />ESR-2613 <br />HTW20 <br />FL17244.8 <br />ESR-3455 <br />HTS30 <br />FL10456.26 <br />ESR-2613 <br />HTW24 <br />FL17244.8 <br />ESR-3455 <br />HTSM16 <br />FL11473.11 <br />SIM200802 <br />HTW30 <br />FL17244.8 <br />ESR-3455 <br />HTSM20 <br />FL11473.11 <br />SIM200802 <br />HTWM16 <br />FL6223.2 <br />Evaluation Report <br />HGT2 <br />FL10456.18 <br />ESR-2613 <br />HTWM20 <br />FL6223.2 <br />Evaluation Report <br />HGT3 <br />FL10456.19 <br />ESR-2613 <br />HUGT2 <br />FL6223.3 <br />Evaluation Report <br />HUS210-2 <br />FL10655.92 <br />ESR-2549 <br />HUGT3 <br />FL6223.3 <br />Evaluation Repo <br />PRODUCT APPROVAL SPECIFICATION SHEET <br />As required by Florida Statute 553.842 and Florida Administrative Code 96-72, please provide the information and approval numbers on the building components listed below if <br />they will be utilized on the construction project for which you are applying for a building permit. We recommend you contact your local product supplier should you not know the <br />product approval number for any of the applicable listed products. <br />Category/Subcategory <br />Manufacturer <br />Product Description <br />Approval Number(s) <br />Test Pressures <br />1. EXTERIOR DOORS <br />A. SWINGING <br />ThermaTru <br />Smooth -Star and Benchmark <br />FL15225.5 <br />+67.0/-67.0 psf <br />ThermaTru <br />Premium, Construction Series and Benchmark <br />FL15225.6 <br />+47.0/-47.0 psf <br />ThermaTru <br />Fiber Classic /Smooth Star <br />FL15000.1 <br />+55.0/-55.0 psf <br />B. SLIDING <br />General Aluminum Company <br />Series 420/430 <br />FL15332.1 - FL15332.5 <br />+40.0/-40.0 psi <br />C. SECTIONAL <br />Clopay Building Products <br />Residential WindCode Doors W5 (8X7) <br />FL15279.37 <br />+30.0/-32.0 psi <br />Clopay Building Products <br />Residential WindCode Doors W5 (16X7) <br />FL15279.53 <br />+30.0/-30.0 psi <br />Clopay Building Products <br />Residential WindCode Doors W6 (8X7) <br />FL15279.85 <br />+38.0/-42.0 psf <br />Clopay Building Products <br />Residential WindCode Doors W6 (16X7) <br />FL15279.102 <br />+37.0/-41.0 psi <br />D. METAL LOUVERED DRS <br />Curries Division of AADG, Inc <br />607,707,727,747,and 847 Single &Pairs of Doors <br />FL11537.1 <br />N/A (see inst sht) <br />2. WINDOWS <br />A. SINGLE HUNG <br />General Aluminum Company <br />Series 1550/1570 <br />FL15217.4 - FL15217.5 <br />+50.0/-55.0 psf <br />General Aluminum Company <br />Series 1900/1970 <br />FL15217.7 - FL15217.9 <br />+40.0/-50.0 psi <br />B. HORIZONTAL SLIDER <br />General Aluminum Company <br />Series 1580/1590 <br />FL15288.1 - FL15288.2 <br />+40.O1-50.0 psi <br />General Aluminum Company <br />Series 1980/1990 <br />FL15288.3 - FL15288.4 <br />+40.0/-50.0 psi <br />C. FIXED <br />General Aluminum Company <br />Series 1550l1570 <br />FL15278.4 - FL15278.5 <br />+40.0/-40.0 psi <br />General Aluminum Company <br />Series 1900I1970 <br />FL15278.7 - FL15278.9 <br />+40.O1-50.0 psi <br />D. MULLION <br />General Aluminum Company <br />1445, 5347 and 5547 Vertical Mullion <br />FL15333.7 <br />N/A <br />E. OTHER <br />3. PANEL WALL <br />A. SIDING <br />James Hardie Building Prod. <br />Cemplank Lap Siding and HardiePlank Lap Siding <br />FL13192.1 - FL13192.2 <br />N/A <br />B. SOFFITS <br />Alside <br />Solid and Vented Soffit <br />FL15272.1 - FL15272.2 <br />+70.0/-70.0 psf <br />C. OTHER <br />4. ROOFING PRODUCTS <br />A. ASPHALT SHINGLES <br />Certain Teed Corporation <br />CT20 (and AR), Landmark 30/40 (and AR), <br />FL5444.1 <br />N/A <br />XT25 (and AR), XT30 (and AR) <br />B. UNDERLAYMENTS <br />Tamko <br />151b Felt Underlayment <br />FL12328.6 <br />N/A <br />HomeGuard Building Products, Inc <br />ToughSkin Synthethic Underlayments <br />FL21675.1 <br />N/A <br />POLYGLASS USA <br />Polyglass roof underlayments <br />FL5259-R26 <br />+NlA/-622.5 <br />C. ROOFING FASTENERS <br />NOT USED <br />D. ROOF VENTILATORS <br />Thompson Arch Metal Comp. <br />Off Ridge Vents <br />FL5219.1 - FL5219.3 <br />N/A <br />Florida Metal Products, Inc <br />Vent RV10 <br />F12075.1 <br />N/A <br />Lomanco, Inc <br />DA-4 Exahust Vent <br />FL17202.1 <br />NIA <br />O'Hagin Manufacturing, LLC <br />O'Hagin's Cloakded Vent Tile <br />FL16588.1 <br />NIA <br />E. ROOFING TILES <br />Boral Tile <br />Villa 900 <br />FL7849.24 - FL7849.26 <br />N/A <br />Boral Tile <br />Saxony 900 <br />FL7849.13 - FL7849.16 <br />NIA <br />F. OTHER <br />5. SHUTTERS <br />A. STORM PANELS <br />Global Protection Products <br />Galvanized Steel Storm Panels <br />FL15076.1 - FL15076.2 <br />Global Protection Products <br />GPP Fabric Shutter Series 2000 <br />FL15088.1 <br />Town and Country Industries <br />Safety Edge Storm Panels <br />FL12856.1 <br />EN/A <br />All American Shutters <br />Galvanized Steel Storm Panels <br />FL17869.1 <br />6. STRUCTURAL <br />COMPONENTS <br />A. WOOD CONNECTORS/ <br />USP Structural Conn. <br />see chart <br />ANCHORS <br />Simpson Strong -Tie <br />see chart <br />B. TRUSS PLATES <br />ITW Building Components <br />Alpine Truss Plates <br />FL1999.1 - FL1999.4 <br />N/A <br />MiTek Industries, Inc. <br />Truss Plates <br />FL2197.1 - FL2197.5 <br />N/A <br />C. ENGINEERED LUMBER <br />Boise Eng. Wood Prod. <br />Versa -Lam SP <br />FL1644.1 <br />N/A <br />Boise Eng. Wood Prod. <br />Wood I -Joists ALLJOIST <br />FL1645.1 <br />N/A <br />Weyerhaeuser <br />Engineered lumber -TJI <br />FL1630.1 - FL1630.11 <br />N/A <br />Weyerhaeuser <br />iLevel Rim Board, LVL, PSL, LSL <br />FL6527.1 - FL6527.4 <br />N/A <br />D. MATERIAL <br />Cast -Crete Corp. <br />High Strength Concrete Lintels <br />FL158.1 <br />N/A <br />Commercial Concrete Products, Inc. <br />High Strength Concrete lintels <br />FL1774 <br />N/A <br />Powers Steel, Inc. <br />PSbox8LT, PSboxBLT(5-5/8} <br />FL5450.1 <br />NIA <br />Powers Steel, Inc. <br />PowerBOXB Lintels <br />FL11383.1 <br />NIA <br />The products listed below did not demonstrate product approval at plan review. I understand that at the time of inspection of these products, the following information must be <br />available to the inspector on the jobsite; 1) copy of the product approval, 2) the performance characteristics which the product was tested and certified to comply with, 3) copy of <br />the applicable manufacturers installation requirements. Further, I understand these products may have to be removed if approval cannot be demonstrated during inspection. <br />APPLICANT SIGNATURE <br />DATE <br />
The URL can be used to link to this page
Your browser does not support the video tag.