i <br />i <br />I <br />i <br />i <br />i <br />i <br />i <br />i <br />i <br />i <br />i <br />---------------------- - ----J <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />POWER CO. FEED — <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 08, 250.94 <br />200A INDOOR PANEL <br />CENTER <br />#14 copper to lights & outlets <br />NEMA 1 <br />200 AMP <br />10 #12 copper to 20 amp ckts <br />10 #10-2 copper to WH <br />10 #10-3 copper to Dryer <br />METER <br />MO2/0 <br />or 4/0 <br />SER Alu <br />200 amp <br />150 amp <br />Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2011 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />I� <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />$4 <br />FOUR-WAY SWITCH <br />ipR <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />O <br />RECESSED LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />® <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />M <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />ROUGH -IN FOR OPT. CEILING FAN <br />�J <br />�/> <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />GO <br />(1) PHONE LINE, (1) DATA PORT <br />Tl <br />2" <br />ql" <br />ill" "1 <br />1 2" VTR I <br />I I <br />I � <br />WM. <br />rtn <br />LAV. <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />FOR <br />DISPOSALWP Ai <br />111 =UNDER SINK <br />1■ -- -- - - ■111111111■�101111111111110 <br />.�� 111 111 <br />i <br />ROUGiWIN <br />OFOR OPT.KITCHEN 2x4 FL -FA /LIGHT <br />-'■ <br />II: <br />o <br />111 111El_- <br />■ <br />2x4 FL.NO <br />i <br />i <br />= i <br />OPTIONAL LIGHTING_ <br />LU <br />F- <br />WZ <br />�OW <br />LY(aj-j <br />>-im <br />DEDICATED <br />RECEPTACLE <br />FOR MICROWAVE <br />RANGE HOOD <br />PER SPECS <br />IRRIGATION GFI <br />@ 44" A.F.F. <br />AC PAD <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS <br />1st FLO <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />DEDICATED <br />RECEPTACLE <br />FOR MICROWAVE <br />RANGE HOOD <br />PER SPECS <br />R ELECTRICAL PLAN <br />SCALE: %4'=V-0" <br />�Lo <br />r <br />M <br />O <br />® O <br />Z <br />C <br />O <br />CL <br />Vn), 0 <br />Q) cs7 <br />LJ J <br />i� <br />'U — <br />O LU C"" <br />~ <br />0 <br />0o <br />Ln <br />R <br />Oro <br />m 04 <br />r�� <br />` V C) <br />LAJ <br />CDM <br />C' ca M <br />Monk E <br />— c0i <br />m-2N <br />O o <br />/ ® to <br />a <br />� U. 00 <br />005 <br />4 f <br />) <br />Y r� <br />OQ O <br />"T <br />Qrn <br />rnQo <br />A 1 <br />N C.B..p C <br />or <br />ti <br />CVN <br />N <br />co <br />N <br />W <br />0 t r <br />04 <br />o 00 <br />d <br />L.L <br />ii (n LE N 0 <br />W Q u M N <br />T <br />W <br />W <br />LL <br />ZVaU)0)3 <br />o <br />� N - 0 <br />0 <br />m m <br />LLar0 <br />W <br />N Cl) <br />N OD <br />W o <br />U <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />i <br />O <br />O <br />Z [V <br />0 <br />1>i U-) O <br />M <br />Q V) <br />a (ALn <br />N 0 <br />U- <br />CL <br />Q� V Q 00 <br />Zfu <br />WJa� <br />to <br />d- <br />0Z <br />W 0 <br />u- <br />wZ I.- <br />g¢w�� <br />UN 0 0 <br />80 Z Q U <br />Z a Q U Q Q <br />iX�wLU <br />Z <br />t9zpaw <br />aa� 8o <br />W N <br />p <br />�a0zo <br />�3J <br />O <br />rl <br />Ln <br />[V <br />(V <br />Ln <br />a <br />/'� Z <br />aWOct <br />ZU0 <br />Q <br />wo00W <br />0ZmoO <br />�a <br />z <br />az—v EoZ <br />pz=0� <br />W <br />F ¢¢Z <br />¢ <br />U <br />wLL <br />wLu z¢ <br />,-� U <br />< Q � <br />u-S <br />O <br />�< <br />a CL <br />U <br />.. W <br />LZ <br />Z <br />J <br />Z <br />W <br />SCALE : AS NOTED <br />PLOT DATE: 12/7/2012 <br />TECH: M)AMES <br />VERSION NO. <br />1122 <br />JOB NO: 17-5171 <br />SHEET NO. <br />5 <br />