My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6623 Paden Wheel St
Zephyrhills
>
Building Department
>
Building Plans
>
6623 Paden Wheel St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 1:05:01 PM
Creation date
2/19/2025 9:04:09 AM
Metadata
Fields
Template:
Building Plans
Street #
6623
Location
Paden Wheel St
Contractor
Lennar Homes
Building Plans - Permit #
19248
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FOLD UP WEATHER <br />RESISTIVE BARRIER & <br />WEATHER RESISTIVE <br />WINDOW UNIT <br />FLASHING REQUIREMENTS <br />TEMPORARILY SECURE <br />BARRIER <br />DOOR ROUGH OPENING <br />WEATHER <br />RESISTIVE <br />SLOPE <br />R612.10 Flashing, Sealants and Weatherstripping. Flashing and sealants for exterior windows shall comply with Section R703.8. <br />9 PP� 9• 9 P Y <br />0.3 in : 12.0 in <br />BARRIER <br />TAPE <br />EXTERIOR <br />WOOD FRAME CONSTR. <br />SELF -ADHERED FLASHING 3/4"-1" BEAD OF CONSTR. <br />( 0.6 cm : 30.5 cm) <br />R703.2 Weather -resistant sheathing paper. One layer of No.15 asphalt felt, free from holes and breaks, complying with ASTM D 226 for Type 1 felt or <br />3 <br />SHEATHING <br />BY LAPPING DOWN ADHESIVE TO BE APPLIED UNDER <br />SELF -ADHERED FLASHING <br />other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be applied horizontally, <br />OVER RIM JOIST AND UP THRESHOLD OF DOOR AND RETURN <br />with the upper layer lapped over the lower layer not less than 2 inches (51 mm). Where joints occur, felt shall be lapped not less than 6 inches (152 <br />(ASSEMBLED NINDOW) <br />WALL BY 6 IN. UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />EXTERIOR <br />) mm . The felt or other approved material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner <br />2 <br />Q <br />Q <br />CEMT. FIN. <br />to meet the requirements of the exterior wall envelope as described in Section R703.1 <br />z <br />WEATHER <br />RESISITIVE <br />SELF -ADHERED FLASHING <br />BUILDING PAPER <br />Exception: Omission of the water -resistive barrier is permitted in the following situations: <br />BARRIER <br />SEAL TOPS OF JOISTS <br />1. In detached buildings. <br />1 <br />WIRE LATH <br />accessory <br />UNDER DECKING SUBFLOOR <br />2. Under exterior wall finish materials as permitted in Table R703.4 <br />SELF -ADHERED FLASHING <br />(SEE DETAIL WP07) • <br />3. Under Paperbacked stucco lath when the paper backing is an approved water -resistive barrier. <br />HEAD FLASHING TIE-IN INSTRUXTIONS: <br />R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into thewall cavity or <br />1. Cut, fold up & temporarily secure weather resistive <br />RIM JOIST <br />penetration ofwater to the building structural framing components. Self -adhered membranes used as flashing shall comply with AAMA 711. The <br />barrier above header to allow for flashing <br />flashing shall extend to the surface of the exterior wall finish. Approved corrosion -resistant flashings shall be installed at all of the following locations: <br />THESE DETAILS ARE GENERIC AND <br />installation <br />MEANT TO SHOW GENERAL FLASHING <br />AND WATERPROOFING METHODS TO <br />2. Self -adhered flashing plus head flashing under <br />weather resistive barrier <br />1 <br />1 <br />1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of he exterior wall finish or to the <br />water -resistive barrier for subsequent drainage. Flashing at exterior window and door openings shall be installed in accordance with one or more of the <br />3. Fold resistive barrier back over head <br />BE USED. <br />weather <br />flashing and seal with tape <br />2 <br />2 <br />O <br />following or other approved method: <br />1.1 The fenestration manufacturer's written flashing instructions. <br />1.2 The flashing manufacturer's written installation instructions. <br />Scale: NTIZM <br />SELF -ADHERED FLASHING <br />FLANGED WINDOW <br />SELF -ADHERED FLASHING ■ <br />, <br />SELF -ADHERED FLASHING <br />' <br />1.3 In accordance with FMA/AAMA 100, FMA/AAMA 200, or FMA/WDMA 250. <br />EXTERIOR DOOR WITH DECK - SECTION A <br />:-MT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER <br />1.4 In accordance with the flashing method of a registered design professional. <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under stucco copings. <br />3. Under and at the ends of masonry, wood or metal copings and sills. <br />EXTERIOR SHEATHING <br />MECHANICALLY FASTEN IF RUBBERIZED RUBBERIZED ASPHALT <br />4. Continuously above all projecting wood trim. <br />EXTERIOR SHEATHING <br />3/a^-1" BEAD OF CONSTR. INSTALL SELF -ADHERED <br />NEEDED IN CORNERS ADHESIVE <br />ASPHALT ADHESIVE <br />THROUGH SELF -ADHERED <br />5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />P Y <br />J► <br />ADHESIVE TO BE APPLIED UNDER FLASHING JAMB & HEAD <br />THRESHOLD OF DOOR AND RETURN FLASHING, SEE <br />FLASHING SELF -ADHERED FLASHING <br />6. At wall and roof intersections. <br />UP JAMB 6". USE LIQUID NAIL BRAND FLANGED WINDOW <br />7. At built-in gutters. <br />OR EQUAL WEATHER PROOF CAULKING (SEE DETAIL WP01) <br />REFER TO TECHNICAL <br />LETTER ON CHEMICAL . , <br />Q <br />SCORED <br />RELEASE PAPER <br />R703.6.2.1 Wee Screeds <br />P <br />COMPATIBILITY <br />A Minimum 0.019-inch (No. 26 GaIv. sheet gage), corrosion -resistant weep screed or plastic weep screed, with a minimum vertical attachment flange of <br />SELF -ADHERED FLASHING <br />SELF -ADHERED FLASHING, <br />_ <br />�� (BEFORE FOLDING, SCORE <br />3 1/2" shall be provided at or below the foundation plate line on exterior stud walls in accordance with ASTM C 926. <br />EXTEND A MINIMUM 6" <br />RELEASE PAPER TO EXPOSE <br />ADHESIVE AS SHOWN) <br />VERTICALLY FROM <br />BOTTOM OF <br />2 3 <br />THRESHOLD <br />SECTION -A (SEE DETAIL WP02) <br />SELF -ADHERED FLASHING <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS <br />2 <br />2 <br />SELF -ADHERED FLASHING <br />5 <br />TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND <br />NAILING FLANGE 1 <br />:-`' <br />4 <br />ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2 <br />DO NOT FLASH OVER <br />2 <br />SEAL TOPS OF JOISTS <br />UNDER DECKING <br />1 <br />6 <br />Detail Instructions <br />Refer to the number marked as #Din detail that to the items in list <br />BOTTOM NAILING <br />FLANGE <br />8 <br />(SEE DETAIL WP07) <br />2 <br />7 <br />each corresponds numbered the of <br />instructions below: <br />1. Install self -adhered flashing in order as shown by numbers <br />SELF -ADHERED FLASHING ■ <br />1 <br />SELF -ADHERED FLASHING ■ ' <br />SELF -ADHERED FLASHING ■ <br />1 <br />HALF ROUND WINDOW <br />EXTERIOR DOOR WITH DECK <br />INSIDE CORNER • <br />2. Install flashing and weather resistive barrier to form water shedding laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, embedded in the adhesive layer) - <br />�Ground� <br />for ease of installation and to minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and adhere to substrate using a square <br />SHEATHING <br />piece of flashing material (6" x 6" Minimum) <br />1 <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to fit tight to corner <br />Water Resistant Barrier <br />8. Mechanically fasten as necessary <br />Lath <br />SELF -ADHERED FLASHING <br />Sheathing <br />PATCH <br />Stucco <br />7/8" Cement Plaster <br />DOUBLE <br />4 <br />in accordance with <br />JOIST <br />ASTMC926 <br />° <br />„ <br />7/8 Cement Plaster <br />SINGLE <br />WOOD BEAM <br />1 <br />° <br />Foundation Wall ° <br />Felt backed metal in accordance with <br />JOIST <br />BELOW <br />SELF -ADHERED FLASHING <br />° <br />lathe in accordance ASTMC926 <br />SELF -ADHERED FLASHING <br />1 <br />° a ° a <br />with ASTMC1063 <br />2 <br />° ° <br />Felt backed metal <br />3" MIN <br />^ <br />Building Paper lathe in accordance <br />SELF -ADHERED <br />SELF -ADHERED <br />4 <br />' With ASTMC1063 <br />FLASHING <br />FLASHING Q <br />5 <br />,',� �� 7/16" O.S.B. <br />' �', sheathing Building Paper <br />i , <br />7/16" O.S.B. <br />Metal , ; sheathing <br />SELF -ADHERED FLASHING <br />■ ' <br />SELF -ADHERED FLASHING ■ <br />1 <br />■ <br />FOUNDATION WEEP SCREED 1 <br />Flashing ' <br />DECK JOIST <br />OUTSIDE CORNER <br />• <br />weep Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain <br />Bottom of Stampede or similar <br />Weep Screed cauk bottom <br />1 1/2" to 2" joint only <br />Above Roof Weep Screed <br />Sheathing Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Cement Plaster Decorative Finish <br />in accordance <br />with ASTMC926 All inside and <br />over wood 2nd •v , outside corner will <br />floor �•�� <br />°•o,o•p need to be miter <br />° cut and caulked all <br />•�°•o,o 0,0.4• butt joints need to <br />becaulked using <br />�°•o S <br />.o <br />Stampede or sim. <br />caulk for all <br />Note: <br />The building paper and metal lath must be <br />Cement installed over the top of the weep screed. <br />Plaster <br />over block <br />1 st floor <br />WEEP SCREED DETAIL <br />NOT USED <br />■ ' <br />NOT USED ■ <br />NOT USED ■ <br />SCALE: NOT TO SCALE <br />0 <br />ZM <br />- o <br />Z <br />Q <br />J <br />Z <br />l/) <br />(1) cn <br />'}'J W <br />0 <br />U - <br />w <br />O c <br />m <br />M <br />o 0 <br />U <br />W <br />- 8 <br />W W <br />a, M <br />c t0 M <br />E LL CD <br />O O O <br />2 m <br />U� <br />� <br />Y <br />Sao <br />Lo O ,r <br />Q Of <br />ch Q O <br />Al <br />B D. <br />NCBDC <br />ti <br />N <br />co <br />co <br />N O r O <br />0Co <br />0 DO <br />z o <br />N <br />Z W N rNi 1,.e <br />p� <br />J <br />Li Z <br />r� IL N 0 O <br />W <br />W LL <br />a a <br />aiCLL <br />Q <br />Z <br />�rnrn <br />�. mro�w <br />fwV y .7 NQ <br />O O <br />m m <br />¢C <br />C Ol .��-p• <br />LLW <br />Q <br />NQc, <br />o <br />O V <br />U <br />❑ ❑ <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code Sth Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />i <br />C) <br />0 <br />Z cV <br />0a)1� <br />>�k.0o <br />Z <br />�M <br />aU-)-fpLn <br />a cn •L d- <br />0 <br />_ <br />H a)U� <br />oC Vrn <br />(a <br />00 <br />Q <br />Z <br />W <br />J � <br />d- <br />OZ <br />W LLL.LLJ Q <br />z v� <br />WmQ}�rlii <br />U <br />Un-o0PZQU <br />zaf__Q <br />=�MWµZI�Z <br />C7 Z W <br />LU W <br />N W <br />O a o O o <br />�F-apz(9 <br />C:)�W <br />rn <br />J <br />Ln <br />�� Q <br />W <br />0 <br />Cod <br />W Q I- � <br />O <br />Q <br />O z <br />uWZl-2 <br />I-Um2 <br />Ce <br />z <br />O <br />z32:R�i <br />O <br />aQoaUP <br />w <br />N <br />O <br />$erg-V6 <br />a <br />C)Qa�og <br />bpfwo <br />N <br />t"-I <br />J <br />li <br />J O W a <br />J L W <br />a0. <br />O <br />O <br />W <br />L <br />< 9 <br />u_ <br />j <br />f- <br />z Q <br />g <br />Z <br />0 <br />a <br />SCALE : AS NOTED <br />PLOT DATE : 12/7/2012 <br />TECH: FFLORES <br />VERSION NO. <br />100 <br />JOB NO: 17-5176 <br />SHEET NO. <br />
The URL can be used to link to this page
Your browser does not support the video tag.