ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER ELECTRICAL SPECIFICATION NOTES: <br />10 #14coppertolights &outlets ELECTRICAL CONTRACTOR MUST VERIFY <br />NEMA1 WITH THE SPECIFICATIONS FOR THE TYPE <br />200 AMP 01 #12 copper to 20 limp ckts <br />10 <br />01 3 #10OF FIXTURE TO BE USED. LIGHT FIXTURES <br />#10-coppertowH copper to Dryer AC PAD SHOWN ARE FOR LOCATION PURPOSES. <br />METER GFI DISC. <br />MAIN 131 <br />P <br />200 am 2/0 or 4/0 ER Alu \ i I i I I I i <br />150amp r,�. 1 IAIA I <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 08, 250.94 <br />Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2011 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />- <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />$4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />O <br />RECESSED LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />J4)" <br />EXHAUST FAN/LIGHT COMBINATION <br />�D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />©2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />r_ IMM <br />ELECTRIC METER <br />F <br />ELECTRIC PANEL <br />-� <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br /><1� <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />C J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />3" VTR III1— <br />' I 3" VTR II I— <br />I 'I <br />3"VTR III_ <br />1 1i11.5" VTR <br />I <br />'I/ <br />\r, S WR <br />KITCHEN 1 1 UB I 3" I C/0 <br />I SINKI ► DBL. <br />I 1 I SINK WC 3"1 I j I <br />I <br />3" I INK I I <br />I I 2" 3" I <br />2" HANSON <br />1SINK BOX <br />3" <br />3" WC UB <br />3" 3" <br />WC 3" PLUMBING RISER_ <br />NOTE: PLUMBING RISER IS SCHEMATIC TO SCALE: NTS <br />BE VERIFIED WITH PLUMBER <br />SPEC 3 & 4 KITCHEN <br />OPT. DEIt\ <br />ROUGH -INS \ <br />FOR OPT. SID. <br />FAN/LIGHT <br />DEN O <br />SCALE: %4'=V-0" <br />I <br />I <br />I <br />TION_ <br />SCALE: %4'=1'-0" <br />ELECTRICAL PLAN <br />SCALE: %4'=V-0" <br />V LO <br />Z o <br />— o <br />Z <br />Q <br />■J <br />a <br />V <br />n�n ' <br />Q) C—n <br />W <br />` V 0 <br />w <br />O <br />y <br />= <br />~ <br />o 0 <br />m r- <br />V U <br />W <br />E <br />�04 <br />C t0 Cl) <br />c0 'O M—� Ooa <br />40) <br />� �co <br />co <br />Y <br />cn O V <br />Q <br />Q O <br />A' <br />B D. <br />N C B D C <br />f• <br />N <br />N <br />to N <br />���� oz <br />°D <br />��,104 <br />z _� <br />j <br />z <br />{W- <br />W — FL o <br />d <br />z <br />c�O 'a <br />N _+ gCg N <br />m m <br />LLf1� <br />W <br />.TaM <br />N �U <br />J o <br />OF - <br />U <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code Sth Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />i <br />O <br />O <br />Z cV <br />O N n <br />i>iU.)MO <br />Z <br />M <br />Q U) 170 Lf) <br />Ln 0 N <br />C <br />LL <br />Q <br />oC U aM-i <br />Q � <br />Z � <br />M <br />WJ <br />0 <br />Cr' <br />oZ <br />WU-o <br />w Z to <br />Of <br />fo0- <br />o <br />ZZaUUZ0 fQ t- <br />Z Z <br />Z <br />C9zo aw <br />�gu oLo <br />o�QsLU <br />�} <br />a=ZO <br />r-1 <br />w <br />�J <br />O <br />Lr) <br />117114 <br />r4 <br />0001 <br />Ln <br />W< o <br />Wun <br />Icy-Z <br />uhe <br />o <br />Q <br />O Q <br />uwZ�- 2 <br />F.tnm� <br />cc <br />z <br />O J <br />or- <br />Z <br />"' z o <br />< <br />W <br />J <br />N <br />L. <br />��QI <br />' a <br />lY$L> <br />w�wOtLZQ <br />p U <br />os <br />>- <br />NdXW,Z <br />I..L. <br />-tOwQ <br />J0Yw <br />aQ�X <br />z <br />O <br />L.L U <br />" <br />• <br />W <br />> <br />O <br />g J <br />Z <br />J <br />a W <br />SCALE : AS NOTED <br />PLOT DATE : 12/7/2012 <br />TECH: MJAM ES <br />VERSION NO. <br />100 <br />JOB NO: 17-5176 <br />SHEET NO. <br />3 <br />