Laserfiche WebLink
`q- <br />rn <br />I <br />L <br />12'-34' <br />OPT. DEN <br />9'-4" FLAT Cl <br />CARPET <br />BA. 3 <br />9'-4" FLAT Cl <br />TILE <br />BEDROOM 3 <br />9'-4" FLAT CLG. <br />CARPET <br />DEN OPTION <br />SCALE: X"=V-0" <br />7- <br />l <br />U) <br />L0 <br />N <br />CM All <br />Ju -u <br />18'-8" <br />18'-0" <br />134" <br />0. <br />2'-0" <br />2'-0" <br />4'_4" <br />9'-0" <br />AC PAD <br />© <br />25 SH <br />© <br />D <br />O <br />25 SH I <br />II'---4----------- <br />- - - - <br />35 SH <br />III <br />o <br />- - - - - - - - - - - <br />*EGRESS <br />*EGRESS <br />HB <br />09 <br />MASTER OF <br />LANAI <br />9'-4" CLG. <br />CV <br />FLAT A.F.F. <br />NOOK <br />BEDROOM rn <br />VAULTEDCLG. <br />1------; <br />\�� <br />VAULTEDCLG. � o <br />ro <br />CARPET <br />09 <br />CARPET w C) tO <br />/�� <br />i <br />LO <br />N <br />II I <br />4'-8" <br />134" <br />i <br />I I <br />E <br />G.T. <br />- <br />� <br />NOTE: FINISHED WALLS_ _ <br />9080SGD_ <br />---------� <br />i TO BE FLUSH. FIELD i <br />�- <br />T <br />VERIFY. <br />I <br />I <br />A <br />1 <br />1 <br />S3 <br />2868 1 �H2>j <br />MN <br />TYP. <br />11-24' <br />-" 37-_0 <br />1 <br />II 9'-34'U.N.O. <br />I <br />- <br />FAMILY <br />1 <br />R&S <br />1 <br />_ <br />11'4' FLAT Cl <br />n <br />CARPET <br />1 <br />WIC <br />G <br />II <br />1 <br />11'-4" FLAT CLG. <br />S3 <br />- J <br />- <br />CARPET <br />- <br />SIM.w/ <br />�? <br />- <br />WALK IN <br />1 <br />_ <br />- <br />SIN. 2x6 92 <br />SPF @ <br />`9 <br />I p W <br />1 1 <br />o? <br />SHOWER -1 <br />M <br />1 <br />2668 <br />= <br />16" O.C. <br />^ <br />Cl) <br />z <br />z <br />I b 0 < <br />I <br />io <br />M <br />TILE TO 7' <br />2468 <br />I� <br />TEMP. GL. ENCL,A.F.F. <br />B /� <br />�I <br />= <br />' <br />ON 42" HIGH <br />HIGH <br />. /`1 <br />_ <br />ITC H E <br />I <br />' <br />KNWL. <br />9' 4" FLAT Cl <br />2468 <br />- <br />I <br />TILE <br />-7i <br />ULTED Cl <br />i <br />M <br />T-82' o R&S <br />_ <br />1 <br />U I CARPET <br />03 <br />17'-8" <br />"9i3 <br />9 "1 s <br />I <br />= <br />_ <br />N R&S <br />I <br />I <br />-71 <br />- <br />"' <br />I <br />I <br />T-5"od <br />= <br />PROVIDE <br />7 94 <br />° 5-71" -12� <br />_ <br />N <br />2468 <br />BLOCKING FOR <br />^i <br />- I---- -----� <br />GRABBAR <br />MC II \A/I� <br />WIC <br />- <br />iv <br />5SH. <br />I <br />2468 <br />- <br />o�0 9'-4" FLAT CLG. <br />2x6 WALL <br />CARPET <br />r` <br />2068 BF <br />00 <br />R&S <br />DINING <br />LIVING <br />T B/ SHWR TILE T <br />M <br />4 SH. <br />�`' <br />9'-4" FLAT Cl <br />9'-4" FLAT Cl <br />7' .F.F. 0 b <br />N <br />CARPET <br />CARPET <br />2068 <br />00 <br />= <br />N <br />CO <br />J <br />Q <br />O <br />cO <br />2 <br />2668 co <br />`N <br />- <br />N <br />- <br />D <br />O <br />Q <br />W 1 L <br />9' C 7' <br />1� <br />0" 3'-92 <br />31,T <br />12'-74 6' 0" <br />1 <br />14'-62 <br />Nip6'-Oq <br />I <br />00 <br />2668 <br />II <br />151 <br />iv <br />O <br />Lu BEDROOM <br />2 <br />2668 <br />II <br />4'-1 �� 5�"1 �� <br />14'-112 <br />W 9'-4" FLAT Cl <br />- <br />2x6 WALL - - - - - <br />CARPET <br />DRYER VENT - - <br />-- <br />- <br />`' <br />+ I <br />THRU ROOF. 1 I IN <br />BEDROOM 4 <br />2468 BF I <br />in <br />25' MAX. 8 151" <br />cn <br />N <br />A <br />rn I <br />I <br />24681 <br />OPT. DEN <br />4 <br />WIC l I <br />LAU I 1 <br />9'-4" FLAT Cl <br />9'-4" FLAT CLG W <br />4" FLAT CLG. <br />CARPET <br />U.N.O. <br />12'-83" <br />4 <br />QI <br />CARPET I <br />4 <br />7� Till 2680 <br />2 6'-1" <br />2 3 . <br />4 <br />12'-33 , <br />4 <br />CO <br />W <br />L A <br />I <br />AHU <br />Q <br />w <br />N <br />R&S <br />2868 <br />T <br />o <br />W <br />m <br />9'-4" FLAT CLG. r- <br />U) <br />71HANSON <br />o cO <br />EDGE OF SLAB 2" BOX @ 36„ <br />CARPET <br />to <br />5'-71" <br />3'4' <br />BEYOND WALL A.F.F. <br />13" <br />6 <br />BUILDER TO PROVIDE <br />5'-1" <br />68 <br />r <br />APPLIANCE PROTECTION <br />r rl <br />541-)C " <br />WHEN REQUIRED PER FBC <br />I . - <br />AI <br />-� I <br />- <br />FOYER <br />31' <br />- <br />_ <br />N <br />11'4" FLAT CLG. N <br />j 2' <br />S4" <br />3 _ <br />„ <br />O <br />TILE <br />°'' <br />Lu <br />- <br />J <br />CC <br />I <br />S3 <br />�LL <br />M <br />_ <br />2868 BA 3 <br />SIM w/ SPF STUDS @ <br />3068 W/ 36"x26"Fn <br />9'-4" FLA r CLG. <br />m <br />GARAGE <br />12" O.C. w/ USP SPT4 <br />STRAPS T&B <br />TRANSOM ABV. <br />_ <br />TILE <br />it <br />9'-4" FLAT Cl A.F.F. <br />-oo <br />NOTE: <br />21368 <br />o <br />`li <br />FINISHED WALLS TO BE <br />G SIM w/ SPF STUDS @ <br />c14 <br />- - - - - - - - - <br />_ _ _ <br />G.T. <br />_ _ _ _ <br />FLUSH. FIELD VERIFY. <br />_ _ <br />S3 12" O.C. w/ USP SPT4 <br />I <br />STRAPS T&B <br />I----------- <br />I <br />0° <br />I <br />ENTRY <br />m <br />I <br />1 <br />SEE ELEV. 1 <br />2'-8" <br />2'-8" <br />U) <br />o0 <br />0 <br />^cam <br />_ <br />G.T. (ELEV. B) <br />I <br />K TYP. @ <br />i <br />_ <br />- - - - - <br />--- <br />- <br />- <br />- <br />I S4 GARAGE <br />I <br />1 <br />1 <br />I <br />1 <br />I <br />BEDROOM 3 <br />I @GARAGE <br />DKTYP. <br />9'-4" FLAT Cl <br />I <br />I <br />o <br />CARPET <br />8 X 7 OVERHEAD DOOR <br />I <br />d <br />O*EGRESS <br />H <br />(2) 25 SH <br />16 X 7 OVERHEAD DOOR <br />l <br />O <br />8'-0" <br />2'-0" 16'-0" <br />2'-0" <br />o. <br />10'-8" <br />4'-8" <br />29'1 <br />64" <br />164" <br />50'-0" <br />REVISION NOTES 12/17/2009: <br />1. ALL CLOSETS THAT ARE NOT WALK-IN CLOSETS <br />ARE TO BE FRAMED DOWN TO 8'-0" A.F.F. <br />2. ALL BLOCK WALL FURRING IS TO BE 24" O.C. <br />EXCEPT IN WET AREAS. SPACE WET AREA <br />FURRING AT 16" O.C. <br />3. NO RECESSES FOR SHOWERS. SHOWERS ARE <br />TO BE PANNED WITH A PRE-FAB. BASE. <br />4. ALL VANITY HEIGHTS ARE 36" A.F.F. <br />5. SLIDING GLASS DOORS ARE TO HAVE A 1-1/2" <br />RECESS. REFER TO MASON'S SCOPE FOR <br />RECESS WIDTH. <br />6. ALL BATHROOMS HAVE ONE MEDICINE CABINET <br />7. ALL 50' PLANS. FRAME BAR TOP AT 40-1/2" A.F.F. <br />8. ALL TUB DECKS ARE SIZED AS FOLLOWS; <br />40' PRODUCT LINE - MIN. 48" x 64" <br />50' PRODUCT LINE - MIN. 48" x 76" <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H 1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />(2) - 2X8 #2 SYP W/ 1/2" <br />H2 <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) - 1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2950 <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2950 <br />(2) - 2X4 #2 SYP W/ 1/2" Follow Q/S4. See Plan for <br />R.A.G. FLITCH PLATE Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />OPENING PRESSURES <br />ENCLOSED-EXPOSURE"C" <br />OA <br />+25.6 / -27.8 <br />W <br />+25.6 / -34.3 <br />© <br />+24.5 / -26.7 <br />OD <br />+24.5 / -31.9 <br />OE <br />+23.0 / -25.2 <br />�F <br />+23.0 / -28.9 <br />OG <br />SEE SN SHEET OH SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE <br />IS AN "ULTIMATE" WIND SPEED. THE <br />WIND PRESSURES LISTED ABOVE ARE <br />ALLOWABLE PRESSURES <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20X26 <br />182X252 <br />S.H. <br />13 <br />20X388 <br />182X374 <br />S.H. <br />14 <br />20X508 <br />182X50 <br />S.H. <br />15 <br />20X63 <br />182X622 <br />S.H. <br />16 <br />20X72 <br />182X712 <br />S.H. <br />2132 <br />27 1/4 X 26 <br />26 X 25 2 <br />S.H. <br />3 33 <br />27 1/4 X 38 <br />N/A <br />S.H. <br />134 <br />2714 X 50 a <br />N/A <br />S.H. <br />2133 <br />N/A <br />26 x 37 4 <br />S. H. <br />1234 <br />N/A <br />26 x 50 <br />S.H. <br />2 35 <br />27 4 X 63 <br />26 X 62 1/2 <br />S.H. <br />2 36 <br />27 4 X 72 <br />26 X 71 1/2 <br />S.H. <br />22 <br />37 4 X 26 <br />36 2 X 25 1/2 <br />S.H. <br />23 <br />37 4 X 38 s <br />36 2 X 37 3/4 <br />S. H. <br />24 <br />374X50$ <br />362X50 <br />S.H. <br />25 <br />37 4 X 63 <br />36 2 X 62 1/2 <br />S.H. <br />26 <br />374X72 <br />362X711/2 <br />S.H. <br />DOUBLE 2 <br />WIDE <br />75" TALL <br />73 2 WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 2 X 251 <br />S. H. <br />33 <br />54 X 38 3 <br />52 2 X 37 4 <br />S.H. <br />34 <br />54 X 50 a <br />52 2 X 50 <br />S. H. <br />35 <br />54 X 63 <br />52 2 X 62 2 <br />S.H. <br />36 <br />54 X 72 <br />52 2 X 71 2 <br />S. H. <br />39X59 <br />40 X 59 <br />N/A <br />S. H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />FLOOR PLAN <br />SCALE: %4'=1'-0" <br />General notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection. <br />• Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Door between <br />garage and residence shall be equipped with solid doors not <br />less than 1 3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1 3/8" thick, or 20-minute fire -rated doors, <br />equipped with self -closing device. <br />• Duct Penetration. Ducts in the garage and ducts penetrating <br />the walls or ceilings separating the dwelling from the garage <br />shall be constructed of a minimum No. 26 gage (0.48 mm) <br />sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl <br />duct board, or other approved material and shall have no <br />openings into the garage. <br />• Other penetrations shall be protected as required by section <br />R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated from the dwelling as per the <br />following: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Ed. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills. <br />In dwelling units, where the opening of an operable window is <br />located more than 72 inches above the finished grade or surface <br />below, the lowest part of the clear opening of the window shall be <br />a minimum of 24 inches above the finished floor of the room in <br />which the window is located. Operable sections of windows shall <br />not permit openings that allow a 4-inch-diameter sphere where <br />such openings are located within 24 inches of the finished floor. <br />Chapter 45 Private Swiming Pools, Section R4501.17.1.9 <br />All doors and windows providing direct access from the home to <br />the pool shall be equipped with an exit alarm complying with UL <br />2017 that has a minimum sound pressure rating of 85 db a at 10 <br />feet. Any deactivation switch shall be located at least 54 inches <br />above the threshold of the access. Separate alarms are not <br />required for each door or window if sensors wired to a central <br />alarm sound when contact is broken at any opening. <br />M1507.2 Recirculation of Air. <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />recirculated within a residence or to another dwelling unit and shall <br />be exhausted directly to the outdoors. Exhaust air from bathrooms <br />and toilet rooms shall not discharge into an attic , crawl space or <br />other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />see Sht. SN1 for installation detail. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18"above flr. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />MASONRY Il @ 9'-4" A.F.F. <br />TYP. 2x FRAME WALL <br />11,11,111,11171 BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO <br />UPLIFT CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />LIVING <br />2599 S.F. <br />GARAGE <br />589 S.F. <br />LANAI <br />144 S.F. <br />ENTRY <br />36 S.F. <br />TOTAL SQ. FT. <br />3368 S.F. <br />INSULATION REQ. <br />LOCATION <br />R-VALUE / TYPE <br />EXT CONC WALL <br />R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 <br />R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 <br />R-19 KRAFT FACED <br />CONDITIONED CEILING <br />R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION I R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />NOTE TO TRUSS COMPANY: <br />ALIGN TRUSSES TO ALLOW <br />FOR A.H. TO BE ALIGNED. <br />O <br />U r <br />Z M <br />0 <br />Z <br />Q <br />O <br />co z <br />O <br />� C� <br />tJ l <br />M In <br />'U <br />- <br />Ij <br />0 <br />~ <br />c <br />l%i � <br />0 <br />o 0 <br />~ <br />U <br />mr <br />a)M <br />Lu <br />E <br />co <br />C ce) <br />(6 a M <br />-o <br />aimf- <br />Ooo <br />= a) <br />U a) <br />L L L 00 <br />oY <br />aa) <br />� Y <br />rn a o <br />Lo O � <br />Q rn <br />0) 0 <br />A <br />1.w. <br />N C B D C <br />a <br />scr!tc <br />�' m �•e � 'O <br />N p�. <br />•i <br />O <br />o 0 <br />- <br />l > .�LLe. �� <br />WU <br />W <br />�•.. <br />,mow N a, a <br />Z a N :9 zg _ <br />W <br />OU <br />U O0 <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />O <br />Z <br />O <br />O <br />li 4-J <br />i>-i inO <br />M <br />Q il a- + ll Li <br />t2 1A <br />Q (1) LL Li <br />z <br />1713 <br />U n.00 <br />§ E <br />Z fill <br />LU <br />OZ <br />wLEo <br />mZZ�o <br />LUt <br />LU <br />z z Q <br />Q°B <br />QUaQ =�?W�z <br />rgJ�0Ln <br />OV)0��o <br />LU N <br />vF-a0ZO <br />wow <br />� J <br />O <br />Lill <br />i <br />rl <br />J <br />w <br />`J <br />C:w <br />M00� <br />O <br />Q <br />Uim0 <br />°W� <br />�> <br />ZoC)=a <br />-0LU <br />z <br />( LU JZO o <br />~p<J <br />J <br />Q <br />OLL � O a <br />J <br />O <br />�WOLLZ¢ <br /><< 0 <br />' ^ <br />y 1 <br />= LL o <br />Ln ZZ <br />I..L <br />TI <br />J Y W <br />aQ�� <br />z <br />C) <br />U.0 <br />LU <br />OJ <br />z <br />a LL <br />SCALE : AS NOTED <br />PLOT DATE: 12/7/2012 <br />TECH: MJAMES <br />VERSION NO. <br />100 <br />JOB NO: 17-5178 <br />SHEET NO. <br />0 <br />LIIt,�,,��,tiT,1kLtiliVti,ll.�AG��Lu:a i iu�a 1e,i �� I I - III'WJ� '�'�C <br />