200A INDOOR PANEL <br />CENTER <br />10 p14 copper to lights & outlets <br />NEMA 1 <br />00 #12 copper to 20 amp ckts <br />200 AMP <br />10 It10-2 copper to WH <br />10 #10-3 copper to Dryer <br />METER <br />MAIN <br />O210 <br />or 4/0 SER Alu <br />200 amp <br />I <br />150 amp <br />I <br />Disconnect <br />I <br />POWER CO. FEED <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />TERMINATION PER <br />#4 GROUNDING WIRE <br />WITH CODE APPROVED <br />NEC 08, 250.94 CLAMP PER 250.50 AND <br />J <br />250.52 OF THE 2011 NEC. <br />GENERAL ELECTRICAL NOTES: <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: <br />unless otherwise noted, <br />PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />III 3" VTR <br />kitchen 44" AFF <br />\ <br />bathroom 39" AFF <br />1II 3" VTR I <br />laundry room 36" AFF <br />I \ I <br />exterior waterproof 12" AFF <br />1.5" VTRIII <br />garage general purpose 42" AFF <br />I I� I <br />r I 1 <br />range 2" AFF <br />I <br />2. All trim plates & devices to be ganged, where possible. <br />I I <br />3. Electrical switches to be at 42" centerline above finished floor. <br />I SHWFit <br />1 <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />I <br />C/0 I 3r. I TU <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />I I I 13" WC <br />installation & sizing of all electrical, wiring & accessories. <br />I I <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />I I <br />SIN 1 2" <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />I I <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />1 3" <br />2" <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />HANSON <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />WC <br />BOX <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />TUB <br />3" 3" <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />3„ <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />PLUMBING <br />is not acceptable. <br />All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />NOTE: PLUMBING RISER IS SCHEMATIC TO <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />BE VERIFIED WITH PLUMBER <br />when the door or window are opened.. <br />/ <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />/ <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />_ <br />— <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />\ <br />ELECTRICAL KEY <br />` <br />GF <br />DUPLEX CONVENIENCE OUTLET <br />KITCHEN <br />IGFI <br />DUPLEX OUTLET ABOVE COUNTER <br />OW P WEATHERPROOF DUPLEX OUTLET <br />I <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />G.F.I. <br />I� <br />HALF -SWITCHED DUPLEX OUTLET <br />II <br />I I <br />o <br />— <br />LL <br />h SPECIAL PURPOSE OUTLET <br />° <br />X <br />N <br />I <br />DUPLEX OUTLET IN FLOOR <br />I I <br />I GFI <br />220 VOLT OUTLET <br />J <br />WALL SWITCH <br />IIGFI <br />�'3 THREE-WAY SWITCH <br />, � <br />1 <br />�?4 FOUR-WAY SWITCH <br />/ <br />$R RHEOSTAT SWITCH <br />0 CEILING MOUNTED LIGHT FIXTURE <br />_ <br />GFI 2GFI <br />0 WALL MOUNTED LIGHT FIXTURE <br />111 3" VTR <br />I� <br />I <br />I <br />DBL. j IKITCHfl=N <br />SINK I ,SINK <br />� I I <br />2„ I I <br />SINKI � <br />3" <br />Y -, - <br />SCALE: NTS <br />O RECESSED LIGHT P.C. FIXTURE PEC 4 KITCHEN - <br />LIGHT <br />FIXTURE WITH PULL CHAIN S 3 <br />TRACK LIGHT SCALE: Y4'=V-0" <br />FLOURESCENT LIGHT FIXTURE <br />® EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />�D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) PA D E N <br />PUSHBUTTON SWITCH (OPTIONAL) / %J-!�� <br />SD SMOKE DETECTOR �/ 'ROUGH -IN <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) S b FOR OPT. <br />FAN/LIGHT <br />f 0 TELEPHONE (OPTIONAL) / <br />❑TV TELEVISION (OPTIONAL) <br />❑TV 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. — <br />II <br />O THERMOSTAT G o <br />II �� 0 <br />ELECTRIC METER <br />PP7 ELECTRIC PANEL <br />BA. 3 <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />ROUGH -IN FOR OPT. CEILING FAN I <br />I <br />v J I <br />DEN OPTION <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT SCALE. Y4'=1'-0" <br />Q <br />--I TUB <br />WC <br />W <br />0 W <br />LL 0 <br />� � J <br />>_jm <br />AC PAD <br />DISC.GFI <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS <br />1 � <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />HB <br />ELECTRICAL PLAN <br />SCALE: Y4'=V-0" <br />O <br />C� <br />Z co <br />o <br />_ <br />z� <br />Q <br />O <br />J <br />t2 <br />z <br />n�n , <br />N <br />W <br />OLij <br />o <br />Ch <br />V 1 <br />�M <br />~ <br />O <br />m n <br />U <br />a) co <br />W <br />k— <br />o <br />C'MM <br />T 'p M <br />O 04 <br />O <br />Rim <br />a) <br />vat) <br />O =FZw <br />'5 00 <br />CY <br />6Qo <br />Q °o) <br />to av <br />CL <br />rn Q o <br />A' <br />B D® <br />N C B D C <br />Ir <br />ti <br />0 <br />GV <br />N_ <br />Cfl N <br />co <br />.w 'w c, — V O) <br />lr, .09 <br />09 0 <br />pp <br />O <br />t[ - <br />CV <br />O 00 <br />Z O <br />ItA Z W MM-Z <br />z <br />=, N .s <br />W N M N <br />� <br />lLl I.I.. <br />a w <br />�I% <br />�W �°wa <br />Z vto� <br />00 <br />yyr90 <br />0N <br />m °° <br />- CN <br />LL� <br />J <br />W t ¢ <br />❑❑ <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications <br />contained <br />within these drawings comply with <br />the Florida Building <br />Code 5th Edition (2014) Residential. <br />Engineer's signature <br />and seal is only for the structural engineering <br />portions of <br />the drawing pages bearing Engineer's signature and seal. <br />i <br />O <br />ON <br />Z <br />� <br />4-J O <br />I —4 M O <br />M <br />Q U Lr) <br />L n <br />� <br />Q L.L. <br />�-' � M <br />IY U p_ '-' <br />Q <br />�00 <br />z`o <br />WJ <br />C) <br />J <br />oz <br />WU_o <br />w m Z Z > <br />OZ}OaO <br />zQQc�Q< <br />=�zwZ <br />rgU0oLo <br />0�g��0 <br />H N <br />UHa0LU <br />ZO <br />w <br />J <br />O <br />r-I <br />L1) <br />�\ <br />Ll4 <br />Ln <br /><^ <br />C11— <br />w LU o <br />`J <br />< Z a <br />(A <br />Z <br />w UUY <br />� <br />O <br />o0Zmo <br />`Q <br />z <br />J <br />zp�frzz <br />ZO^' <br />�J <br />�8�J <br />wO <br />� <br />8- I-� <br />EL <br />OULI <br />w <br />� Q Q O � <br />ax�Z <br />")`noza <br />O <br />d' <br />�"� <br />< C Y w <br />¢Q�g <br />z <br />O <br />U. U <br />w <br />W <br />> <br />OJ <br />J <br />g <br />z <br />a W <br />SCALE : <br />AS NOTED <br />PLOT DATE : <br />12/7/2012 <br />TECH: <br />MJAMES <br />VERSION NO. <br />100 <br />JOB NO: 17-5178 <br />SHEET NO. <br />3 <br />