6648 Paden Wheel St
Zephyrhills
>
Building Department
>
Building Plans
>
6648 Paden Wheel St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 12:41:41 PM
Creation date
2/19/2025 9:04:21 AM
Metadata
Fields
Template:
Building Plans
Street #
6648
Location
Paden Wheel St
Contractor
Lennar Homes
Building Plans - Permit #
19247
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• ` �`" "°fie "` GENERAL CONCRETE LINTEL SCHEDULE ALTERNATE POWERS <br />• • • • ° • APPROVED LINTEL MANUFACTURERS: CASTE-CRETE, QUALITY STEEL LINTEL F F F z M <br />O O o <br />8F8-1 B/1T 8F8-0B/1T • ,'', •,; • °•a; •,,y Z CO <br />I O ® TYPE DESIGNATION #5 REBAR AT TOP #5 REBAR AT TOP Z <br />F = FILLED WITH MIN. (1) REQ'D MIN. (1) REQ' Q 1-1/2" CLEAR <br />Q <br />J <br />I • • • • GROUT / U =UNFILLED ° � CLEAR <br />I 8RF14-1 B/iT 8RF14-OB/1T R = RECESSED <br />I ' © O QTY. OF #5 G <br />° % •) REBAR @ BOTTOM F D C Z <br />; �'° ' a �'° OF LINTEL CAVITY a M.U. w Q (/) U <br />LU <br />Z a ° GROUT r `'Q o /i F •U <br />Ln <br />QUANTITY OF ° o O O �a ~ <br />•' •' NOMINAL. L 5 REBAR AT w J N i� E <br />• • • ° • • • • • WIDTH #5 REBAR AT ° O BOTTOM OF ¢° w D D #5 REBAR AT BOTTOM � y M <br />-------------------------------� TOP LINTEL CAVITY <br />8F16-OB/1 T 8F16-1 B/1T NOMINAL— ° a a - = AS INDICATED r <br />8F20-OB/1T 8F20-1B/1T -BOTTOM 00 0 0 m <br />O O O O HEIGHT REINFORCING LL a � N M <br />f� E N-2O M <br />7-5/8"ACTUAL PROVIDED IN LU <br />8" NOMINAL WIDTH LINTEL 16 GAUGE POWERS p •— CV <br />° . , a i ° (VARIES) STEEL BOXED LINTEL = — <br />s <� • MATERIALS POWERS STEEL BOXED LINTEL NOTES (ALT.) loin a) 15 'i <br />to ao <br />^Zrn rnQo <br />1. fc precast lintels = 3500 psi. C �e LO 0 v <br />ONLY IF NOTED ON LINTEL PLAN 0 <br />• ° • 2. fc prestressed lintels = 6000 psi. <br />8RF6-OB/1 T 3. grouted per ASTM C476 fg = 3000 psi w/ 1. Refer to manufacturer's specifications for installation. <br />° , , ; . v s , ; v 4. maximum 3/8" aggregate and 8" to 11" slump. 2. Contractor to provide proper protection of lintel to prevent rusting. <br />© 5. Concrete masonry units (CMU) per ASTM C90 w/ Refer to manufacturer's specifications. A 1 N c s D c <br />minimum net area compressive strength = 1900 psi. 3. If lintel is scratched or damaged refer to Powers Steel for repair. <br />70 low relaxation. X"",d ,6. Rebar per ASTMA615 Grade 60. 4. Lintel depth to match precast depth. One #5 Bar required at top <br />Prestressing strand per ASTM A416 grade see lintel plan/details for bottom steel required.7. 270 low relaxation. <br />UL <br />. '7/32 wire per ASTM A510. 5. A bonding agent must be applied to the Steel Box lintels prior to2 ' applying the cementitiuos coating. See contractor specifications`" 8. Mortar per ASTM C270 type M or S.d<"A ''s.,� N f <br />° • 8F20-1 B-2TNL <br />0- K • • • ° • GENERAL INSTALLATION NOTES flu),e°��Provide full mortar head and bed joints.(� <br />° d O 8RF22-1 B/1 T 8F24-OB/1 T 8F24-1 B/1 T�' J <br />2. Shore filled lintels as required. u, <br />3, Installation of lintel must comply with the architectural and/or structural drawings. 0 co � z rLU <br />O 4. U Lintels are manufactured with 5-1/2" long notches at the ends to accommodate <br />J <br />O O U-Li I cell reinforcing n r tin `a 9 <br />. 4. vertical e and grouting. g Q v 4 (3 <br />5, All lintels meet or exceed L/360 vertical deflection, except lintels 1 T-4" and Z O c',at <br />longer with a nominal height of 8" meet or exceed L/180. <br />° 6. Bottom field added rebar to be located at the bottom of the lintel cavity."c7 ' <br />° s • a° , . a e'`,'v a ° 7, 7/32" diameter wire stirrups are welded to the bottom steel for mechanical anchorage.LL ...... q <br />8. Cast -in -place concrete may be provided in composite lintel in lieu of concrete W E S Si W <br />s: s: °, • masonry units. <br />9. Safe load ratings based on rational design analysis per ACI 318 and ACI 530 F R pat its IFt <br />110 <br />10. Product Approvals: Miami Dade County, Florida Nos.03-0605.05 and 03-0605.04. <br />° 11. The exterior surface of lintels installed in exterior concrete masonry walls shall have <br />To the best of the Engineer's knowledge, information, and <br />a coating of stucco applied in accordance with ASTM C-926 or other approved <br />a belief, the structural plans and specifications contained <br />Coating. <br />,, w° - a•- a,- - ,- <br />av•� , '•s'v , •. , • , . . ° , . a °,,', •,•, °, 12. All lintel dimensions shown are "overall" lintel lengths. Code 5th Edition (2014) Residential. Engineer's g 'sBsignature <br />13. Lintels loaded simultaneously with veritcal (gravity and uplift) and horizontal (lateral) LINTEL PLAN NOTES. <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />loads shoud be checked for combine loading with the following equation: <br />° ° ° • >: ° Applied vertical load Applied horizontal load 1- THIS PLAN IS TO BE USED FOR STRUCTURAL INFORMATION ONLY. <br />Safe verticalload Safe horizontal load <1,0 2- UNLESS NOTED OTHERWISE ALL LINTEL DEPTHS ARE TO BE <br />�,• a.• a - ° �• ASSUMED TO BE 16" MINIMUM DEPTH. <br />• • • • • • • • • `° • • • • • • `° • 3- THE NUMBER OF COURSES OF MASONRY REQUIRED BETWEEN THE o <br />81F441B/1T8F400B/1T 8RF400B/1T 8F321B/1T 8F320B/1T 8RF301B/1T 8F280B/lT 81728113/1T LINTEL & THE BOND BEAM SHOULD BE COORDINATED WITH <br />® © ® o <br />THE ELEVATION DRAWINGzO a �OA OO an4-THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE PROPER 5 LINTEL HEIGHT. o <br />M <br />5- LINTELS AT GARAGE DOOR OPENING ARE MINIMUM DEPTH REQUIRED F Q �n .f0 n <br />FOR THE DESIGN LOADS. THE DEPTH MAY BE INCREASED IF REQUIRED <br />F FOR PROPER LINTEL HEIGHT,G.C. COORDINATE. ¢ l <br />C V ry ,M_I <br />Q 0- CO <br />E <br />fu <br />POWER STEEL LINTEL IS AN ADEQUATE w o <br />F ALL LOCATIONS UNLESS J SUBSTITUTION <br />O � W� <br />NOTED OTHERWISE AT OPENING LOCATION <br />O � <br />Wz <br />F U_o <br />W m Z CL <br />Z > <br />�o�zaoo <br />ZQ<UZ< <br />SO �?ZF'Z_J2a�EDCe <br />VU <br />�O "I— <br />apZp <br />Ore)O � � J MIN. � <br />n <br />5 Ln <br />D1 <br />Ln a <br />LU J <br />I— <pa <br /><ZU� <br />"I-°m2 <br />O O O= w � H <br />Z lO WObo�z <br />N (DQ_JwUo <br />> J N Q o8LU <br />LL LL> g O a <br />LUWawOLLZQ <br />O /J EO <br />Lr) 1.) LL <br />Z <br />J O w <br />O J a�W <br />w Q~� <br />O rn <br />O LL <br />Z U. F— <br />> O g z <br />Z J a J <br />OSCALE : AS NOTED <br />MIN. PLOT DATE : 12/7/2012 <br />O MIN. O TECH: MJAMES <br />LINTEL PLAN VERSION N0. <br />SCALE: %4"=1'-0" imo <br />JOB NO: 17-5174 <br />SHEET NO. <br />L 1 <br />