Laserfiche WebLink
Y <br />CORNER OF <br />HOME <br />GARAGE SIDE <br />ROOF DIAPHRAGM NAILING SCHEDULE <br />RIDGE LINE <br />O, <br />�, <br />w <br />15/32" CDX <br />m¢ <br />PLYWOOD OR <br />O <br />7/16" OSB <br />RIDGE LINE <br />140 MPH <br />(ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE 140 MPH i(ult) 3 SECOND GUST EXPOSURE "C" <br />WIND ZONE <br />8d RING SHANK NAILS @ 6" O.C. & 8d RING SHANK NAILS @ 6" O.C. EDGES & <br />+ + + 4" O.C. @ GABLE END WALL OR GABLE TRUSS 8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE <br />+ + 0.113 <br />INCH NOMINAL SHANK DIAMETER 0.113 INCH NOMINAL SHANK DIAMETER <br />RING <br />DIAMETER OF 0.012 OVER SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH 16 TO 20 RINGS PER INCH <br />0.280 <br />INCH FULL ROUND HEAD DIAMETER 0.280 INCH FULL ROUND HEAD DIAMETER <br />2 <br />INCH NAIL LENGTH 2 INCH NAIL LENGTH <br />NOTE: * <br />FOR 8d RING SHANK NAILS 0.113x 2x 3/8" RING SHANK COIL GUN NAILS MAY BE USED <br />1) SEE STRUCTURAL <br />NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. <br />2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. <br />3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING CONSISTS <br />OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ <br />+ <br />+ + <br />+ + <br />+ + + + + <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ <br />+ <br />+ + <br />+ + <br />+ + + + + + <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+++ <br />+++ <br />+ + <br />+ + <br />+ + <br />+ + <br />+++ <br />+++ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ <br />+ <br />+ + <br />+ + + + + <br />+ <br />+ <br />+ <br />+ + <br />+ + <br />++ <br />+++ <br />++++++++ <br />+ <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" <br />5000s 1.8/1.7 <br />p nel <br />wood panels <br />Two 3/4" wood panels or 2 x _ <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2 x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONS <br />(Not required if both loa <br />Filler <br />1/8" gap <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4) Place joists together and nail from each side with 2 rows of 10d nails <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite <br />OF THE JOIST ASA REQUIRED LEAVING y" GAP @ TOP sides by 6". <br />DOUBLE JOIST CONNECTION <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />*Non -stacking walls over squash=20 blocks and <br />require additional wall or beam below.* <br />consideration. Check <br />11 local building <br />code for appropriate 1 /16" <br />10 -0 details in One 10d box <br />TANK -LESS W/H areas=20 of high ;or--20 sinker <br />F1lateral load. 1 at bearing.nail each <br />5'-0" <br />STUB -OUT FOR -' <br />GAS METER O — <br />a <br />N <br />H C G <br />000 IW <br />Q - <br />0 <br />1'-011 0 9 <br />' O LO <br />� v <br />0 <br />x <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />**ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-5" <br />(2) 16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2"X. 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />(1 USP HTW20 OR 3) 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) USP HTW20 OR (4) 16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2) 16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2) 16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2) 16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'-4" <br />(1) USP HTW20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Boise Joist Blocking <br />Use 3" (10d) nails at 6" o.c. <br />Load bearing walls <br />Provide adequate bearing <br />for each lapped joist. <br />Squash block 10d nails SECTION @ INT. BRG. WALL <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or N.T.S. <br />Glulam Beam <br />MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D <br />(see table below) (KNOCKOUT EXEMPTS) D <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />AK� <br />STD. 90' HOOK BOND BEAM <br />U) <br />w <br />a CONT. #5 <br />BAOR >�� BAR <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />PLYWOOD FLOOR <br />SEE PLAN FOR REQ'D <br />SHEATHING PER PLAN <br />COLUMN AND <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br /># OF 2nd FLOOR <br />Solid block all posts from <br />STUDS <br />above to bearing below. <br />SECTION @ INT. BRG. WALL <br />N.T.S. <br />1/8" min. ) Small gap 2°min. <br />2" <br />max. � 4 max. <br />4 <br />Clinch nails <br />when <br />possible 1 <br />Tight fit <br />2x4/Plywood/OSB web stiffener 2" min. <br />required when indicated or 4" max. <br />Web Stiffener Fastener Schedule <br />Joist BearingLocation <br />Series De th End Intermediate <br />BCI 5000s® <br />9-1/2" <br />2-8d <br />2-8d <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />BCI 6000s8 <br />BCI6500sw <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BC160s® <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI90s® <br />11-7/ " <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />- Hangers with side nailing. <br />-Hangerswithsidesnotcontaining WEB STIFFENER <br />top flange of joist. <br />- Birdsmouth cuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : - for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />�— blocking and wall or beam below.* <br />Use 10dx3" nails at( <br />blocking panel *Non• <br />require additional co,..,.., u,, <br />rl 6-1' <br />A 1%" ROUND HOLE MAY <br />BE CUT ANYWHERE IN CANTILEVER <br />THE WEB. PROVIDE AT <br />LEAST 3" OF CLEARANCE <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Y2" <br />NOTES: <br />DO NOT CUT HOLES <br />LARGER THAN 1�" <br />ROUND IN <br />CANTILEVERS. <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1%" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE 1Yz" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN, <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />When joists meet over wall, provide <br />1-1 3/4" minimum bearing for each. <br />Plumbing <br />Joist <br />I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S. <br />Backer block (12" wide min.) <br />Nail with 10-10d nails. <br />\Install tight to top flange. <br />Joist hanger <br />y \ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gap <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />0.6 X Joist <br />D `depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />U, <br />M <br />5/8"1 <br />THE <br />BOL <br />R TRUSS <br />'OP PLATE <br />I.0 <br />TYPICAL USP MUGT15 TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL HUS INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL HTA 20-18 / HTA 20 <br />INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />SLEEVE THRU STEM—/ <br />° <br />SEE PLAN FOR—"°• ° . • <br />FOUNDATION INFO ° a. d' <br />STEM FOUNDATION <br />GRADE <br />° <br />REINF. SEE PLAN <br />LA/C CHASE 4" PVC (2) #5 REBAR <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />HTA 20-18 / HTA 20 <br />INSTALLATION @ MID SPAN <br />LOCATION OF <br />SECOND RT16 <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />USP RT16 USING <br />16-8d x1 1/2" NAILS <br />UPLIFT = 1030# <br />TYPICAL RT16 INSTALLATION <br />TYPICAL MTW INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENETERED @ PIPE <br />PENETRATION <br />IIII�11�11�11. - <br />12" BELOW <br />GRADE <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />r�� 1 <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE VERTICAL THRU FND. <br />TOP (2) #5's x 4' 0" PVC OR SCH40 SLEEVE <br />CENETERED @ PIPE <br />PENETRATION PLUMBING LINE <br />—------------- <br />e <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENETERED @PIPE <br />PENETRATION PLUMBING LINE <br />-- —�.—�.--n—,— n° of av G <br />d <br />__ }=ram 1 7=f • � ° � I <br />d /a <br />—I I � � \ ° •. i • TJI � I— <br />Tf d — — T_ <br />a <br />SEE FND. PLN. <br />01 SIZE & REINF. <br />Z m <br />0 <br />Z <br />Q <br />O <br />J <br />r2 <br />z <br />(n <br />V) (D <br />W <br />� p <br />U — <br />W <br />0 <br />~ <br />o <br />t./) <br />00 <br />U <br />LUC <br />F— <br />U <br />Rig <br />a cco m <br />cc m <br />N 'O m <br />CN <br />0 O p <br />a) <br />LL00 <br />:3 00 <br />U (Dco <br />LO v <br />Qrn <br />rnQo <br />A , <br />_a D <br />D® <br />N C,B <br />C& <br />/ /F 1 <br />q, <br />N% <br />i <br />o <br />.. <br />Z z/� <br />LU <br />� F <br />!.a- <br />Ltd.D <br />Z e <br />LL".• <br />a" <br />U <br />To the best of the Engineer's kn hji) WMation, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />O <br />oN <br />z <br />0 � � <br />UO­ � <br />1 (4 <br />z <br />M <br />Ln <br />CL to .L <br />V)fu <br />Ln <br />a L U_ <br />0� V 00 <br />Q <br />E� <br />z§� <br />J <br />W <br />d- <br />OZ <br />uo W <br />z <br />wm�z5a <br />UI—�y00 <br />or <br />z0aw <br />z a Q U Q Q <br />? w - Z <br />� g � _ <br />Ln <br />0. U LO <br />O'l�'o 'ooo <br />U~a.0z <br />M <br />LU z <br />LU <br />O <br />Ln <br />PV <br />N <br />L0 <br />,—I <br />oa <br />BLU <br />Q z U 0 <br />� <br />o <br />a <br />C <br />P�Nm2 <br />oz� <br />CL <br />w <br />O <br />Z <br />UJ <br />I— <br />(D UJC.z <br />8 1g - � <br />22>9 <br />W WOu_zQ <br />ce Q o 0 <br />Ln <br />N <br />o-o <br />O <br />O <br />U-) <br />J Y LU¢a�� <br />I— <br />c) <br />N <br />w <br />z <br />.. <br />> <br />O <br />g <br />z <br />J <br />a <br />SCALE : AS NOTED <br />PLOT DATE : 12/7/2012 <br />TECH: FFLORES <br />VERSION NO. <br />106 <br />JOB NO: 17-5173 <br />SHEET NO. <br />SN 1 <br />