My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6679 Wagon Trail St
Zephyrhills
>
Building Department
>
Building Plans
>
6679 Wagon Trail St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2025 1:29:58 PM
Creation date
2/19/2025 8:46:55 AM
Metadata
Fields
Template:
Building Plans
Street #
6679
Location
Wagon Trail St
Contractor
DR Horton Inc
Building Plans - Permit #
19237
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BACKER ROD <br />BACKER ROD <br />WRB LAYER'(, <br />STUCCO WRAP <br />INSTALL 6' SELF -ADHERING <br />MEMDRANNE FLASHNG OVER <br />TOP, SIDES) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SEQUENCE OF FLASHING TO BE, <br />I. BOTTOM, 2. SIDES. 3_ TOP <br />VENT CAP IS TO BE SET IN BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT IS TO BE <br />TOOLED SO AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />APPLY SEALANT AT PERIMETER OF <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDES. Y1 CAULKING • JOINT <br />ALL AROUND <br />PER FBC R703.6.1 <br />EAerlor la ft end ftsterirq <br />Exteft we of poMand cement plaster <br />shall campy with the applicadw <br />requln ments of ASTM C 926-12A <br />Installation Of exterior lathing and framing <br />shall oon" with ASTM C 1063-12A. <br />HOODED VENT <br />X J' THICK, 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />WRB LAYER 2, FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER VENT ( FRAME) <br />WOOD SHEATHING <br />WRB LAYER -1, <br />STUCCO WRAP <br />WI;a3 LAYER 2, FORTIFIBER <br />BUILDING PAPER <br />WOOD — <br />0"TUCTION <br />—METAL LATH <br />S' cm VNYL CASING BEAD <br />`C W RAISED BAND <br />)J' TO V run.uu i <br />. WEEP SCREED <br />6' WIDE STRIP SELF <br />AD4 ESIVE FLASHING, CLEAN <br />MASQNRT BEFORE APPLYING <br />Z FLASHING <br />STONE VEI.EER <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCK( <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER "1, STUCCO WRAP) <br />WRB LAYER "2 (FORTIFIBER — — — — — <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO 0 <br />WOOD SHEATHING �TlT/7TIT/TIT <br />SELF—ADHESIVE FLASHING — — — — — <br />NOTE: <br />METAL LATH: LATH TO BE PER FBC <br />R"103.6.1 / ASTM C-847-09, MIN. 2.5 LBS. <br />PER SQ. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />STUCCO <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP a SIDES <br />SELF <br />FLASHING <br />UNIT <br />PREMANUF. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT a <br />TOP a SIDES <br />6B DRYER VENT (BLOCK) <br />BUILDNG PAPER <br />OVER 'QUICK <br />FLASH' <br />PIPE THROUGH — <br />WALL <br />6' SELF ADHESIA <br />FLASHING (INSTAL <br />PER MANIF. SPEC <br />BUILDING PAPER <br />UNDER 'QUICK FL, <br />x-WENT PENETRATION <br />SCALE: N.T.S. <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />AREA TO RECEIVE <br />STUCCO SCRATCH COAT <br />a 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />CONSTRUCTION <br />WOOD SHEATHING <br />WRB LAYER 01, <br />STUCCO WRAP <br />WRB LAYER 02, FORTIFIBER <br />BUILDING PAPER <br />THICK, 3 COAT CEMENT <br />PLASTER <br />Ye TO Ye' MID -WALL <br />WEEP SCREED <br />�6' SELF-ADHESIVE <br />FLASHING <br />_woor_> <br />FRAMED <br />WALL <br />HORIZONTAL WEEP SCREED <br />( FRAME TO FRAME) <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />-('GREAT STUFF' OR SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />PROVIDE STUCCO SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING N <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />WPM LAYER -1, <br />STUCCO WRAP <br />WOOD SHEATHING <br />APPROVED <br />HOUSEWRAP <br />BELOW <br />CUT SUCH TFIA' <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY TO FAX <br />EDGE <br />APPLY E-Z <br />OVER 60 MI <br />GRADE 'D' <br />FELT-PROVII <br />SEALANT AT <br />JOINTS AND <br />INTERSECTIC <br />WOOD <br />CONSTRICTION <br />a' cr1U <br />WOOD SFEATHING <br />WRB LAYER'(, <br />STUCCO WRAP <br />UIRB LAYER 2, FORTIFIBER <br />BUILDING PAPER <br />METAL LATH <br />FASTEN TO WOOD STRUCTURAL <br />MEMBER • l' O,C. MAX <br />K' TO A, Mn-WALL <br />VEEP 90REED <br />�W WIDE STRIP SELF <br />ADFESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYING <br />FINISH • MASONRY TEXTURED <br />7B HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK( <br />STEP #1 <br />STEP #3 <br />e' <br />WRB LAYER 01, <br />STUCCO WRAP <br />CUT 'X' INTO ><, <br />SELF -ADHERING <br />MEMBRANE FLASHING <br />APPLY SELF -ADHERING <br />MEMBRANE FLASHING <br />OVER BOX AND OVER <br />APPROVED UNS LAYER <br />STEP #2 <br />APPLY 60 MIN <br />GRADE 'D' FELT <br />OVER <br />kl <br />SELF -ADHERING <br />FLASHINCs OVER <br />APROVED <br />HOUSEWRAP <br />WRB LAYER *I, <br />STUCCO WRAP <br />SELF -ADHERING <br />MEMBRANE FLASHING <br />WRB LAYER 02, FORTIFIBER <br />BUILDING PAPER <br />STEP #4 <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ G.Y. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />METAL LATH <br />STEP #5 STE-P a& <br />OELECTRICAL RECEPTACLE <br />AtICN IT[CT{ <br />Gro 1 ino <br />141 N. RONALD REAGAN BLVD. <br />LONG WOOD, FL 32750 <br />PH: 407.7744078 <br />FAX- 407-7744078 <br />www.abdesigngroup.com <br />AA#,. 0003325 <br />M <br />y <br />'d <br />0 <br />a <br />y <br />4 <br />3 <br />x <br />SvsD:v. kl <br />SILVERADO <br />LOT 40 <br />BLK 6 <br />Pnoascw <br />04128.000-04061 <br />1[oas>� <br />4EJB <br />"2807— ELLE" <br />GAItAGR 8'W32M: <br />RIGHT <br />PAOlft <br />WALL <br />ASSEMFI <br />Y <br />DETA-LS <br />150 mpi <br />10/18/17 <br />x2mm" <br />WAS <br />