ROOF VENT CALL. ELEV. 'L' <br />Nerve A— i/900 RATIO AT HIGH I LOW 1/150 RATIO AT HIGH & LOW <br />AREA 1 840 SF 202.06 In0 1405.92 WO <br />1 /150 RATIO: <br />1 /300 RATIO: <br />GENERAL CONTRACTOR SHALL VERIFY THE <br />AS AN ALTERNATE TO THE 1/150 RATIO LISTED, THE NET <br />NET FREE VENTILATION OF THE VENT <br />FREE CROSS -VENTILATION AREA MAY BE REDUCED TO 17J00 <br />PRODUCT SELECTED BY OWNER VERIFY WITH <br />WHEN A VAPOR BARRIER IS HAVING A TRANSMISSION RATE <br />MANUFACTURER OF HIGH AND LOW VENTS TO <br />NOT EXCEEDING I -PERM INSTALLED ON THE WARMHN- <br />BE USED FOR MINIMUM CALCULATED VENTS <br />WINTER SIDE OF THE CEILING. <br />REQUIRED. TIE REWIRED VENTILATION SWILL <br />BE MAINTAINED. PROVIDE INSULATION STOP <br />GENERAL CONTRACTOR SHALL VERIFY THE NET FREE <br />SUCH THAT INSULATION DOES NOT OBSTRUCT <br />VENTILATION OF THE VENT PRODUCT SELECTED BY <br />FREE AIR MOVEMENT AS REQUIRED BY THE <br />OWNER VERIFY WITH MANUFACTURER OF HIGH AND LOW <br />BUILDING OFFICIAL <br />VENTS TO BE USED FOR MINIMUM CALCULATED VENTS <br />REQUIRED. THE REQUIRED VENTILATION SHALL BE <br />ALL OVERLAP FRAMED ROOF AREAS SHALL <br />MAINTAINED. PROVIDE INSULATION STOP SUCHTHIAT <br />HAVE OPENINGS BETWEEN THE ADJACENT <br />INSULATION DOES NOT OBSTRUCT FREE AIR MOVEMENT AS <br />ATTICS IN THE ROOF SHEATHING (AS ALLOWED <br />REQUIRED BY THE BUILDING OFFICIAL <br />BY THE STRUCTURAL ENGINEER) TO ALIAW <br />PASSAGE AND ATTIC VENTILATION BETWEEN <br />ALL OVERLAP FRAMED ROOF AREAS SHALL HAVE OPENINGS <br />THE TWO OR ISOLATED ATTIC SPACES SHALL <br />BETWEEN THE ADJACENT ATTICS IN THE ROOF SHEATMNG <br />BE VENTED INDEPENDENTLY TO MEET 2020 <br />(AS ALLOWED BY THE STRUCTURAL ENGINEER) TO ALLOW <br />FLORIDA BUILDING OODE. <br />PASSAGE AND ATTIC VENTILATION BETWEEN THE TWO OR <br />ISOL ATED ATTIC SPACES SHALL BE VENTED <br />PER DEVELOPER, AT ALL CANTILEVERED <br />INDEPENDENTLY TO MEET 2020 FLORIDA BUILDING OODE. <br />FLOORS. CANTILEVERED DEOORATIVE <br />PROJECTIONS, AND ANY DOUBLE FRAMING <br />PER DEVELOPER, AT ALL CANTILEVERED FLOORS, <br />PROJECTIONS THAT ARE SEPARATED FROM <br />CANTILEVERED DECORATIVE PROJECTIONS, AND ANY <br />THE VENTING CALCULATIONS SHOWNABOVE, <br />DOUBLE FRAMING PROJECTIONS TRATARE SEPARATED <br />PROVIDE CONTINUOUS2*CORROSION <br />FROM THE VENTING CALCULATIONS SHOWN ABOVE, <br />RESISTANT SOFFIT VENT AT UNDERSIDE OF <br />PROVIDE A CONTINUOUS 2' CORROSION RESISTANT SOFFIT <br />FRAMED ELEMENT. <br />VENT AT UNDERSIDE OF FRAMED ELEMENT. <br />NOTES: <br />D ALL ROOF DRAINAGE SHALL BE PIPED TO 0 TRUSS MANUFACTURER SHALL SUBMIT STRUCTURAL CALCS <br />STREET OR APPROVED DRAINAGE AND SHOP DRAWING TO THE BILOER'S GENERAL <br />FACILITY. CONTRACTOR AND BUILDING DEPARTMENT FOR REVIEW <br />0 DASHED LINES INDICATE WALL BELOW PRIOR TO FABRICATIONS. <br />0 LOCATE GUTTER AND DOWNSPOUTS PER 0 ALL PLUMBING VENTS SHALL BE COMBINED INTO A MIMMUM <br />BUILDER AMOUNT OF ROOF PENETRATIONS. ALL ROOF PENETRATIONS <br />0 PITCHED ROOFS AS NOTED. SHALL OCCUR TO THE REAR OF THE MAIN FUDGE. <br />LOT 2 <br />� ROOF PLAN TILL <br />114'.1 AT22'XS4'lAYOUT 1fir =1'-0'AT 11* X 17' LAYOUT <br />ISSUE DATE: <br />ffi1111#1 <br />05.03.2022 FOR <br />// <br />,,, <br />1� REVIEW <br />,%%% ,,,,. <br />SIONS: <br />'y �y • <br />•W <br />..• <br />• <br />,rj <br />I I 41t 1*111if p of stm <br />darennottbbe <br />utized for cmfttion, -or <br />copied in part or in whole <br />wdhout permission from <br />the buider. 0 2022 <br />Stnfight Homes <br />LAST REVISION <br />LAST SAVED BY: <br />SHEET NO <br />FL 5.13.8 <br />