LCTfRf SAL <� <br />K)-- DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />Rg P. WEATHERPROOF DUPLEX OUTLET <br />�F GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />�$ HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />13 THREE-WAY SWITCH <br />14 FOUR-WAY SWITCH <br />$ D DIMMER SWITCH <br />CEILING MOUNTED INCANDESCENT LIGHT FIXTURE <br />WALL MOUNTED INCANDESCENT LIGHT FIXTURE <br />;Q- RECESSED INCANDESCENT LIGHT FIXTURE <br />c LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />f� EXHAUST FAN <br />Q', EXHAUST FANLIGHT COMBINATION <br />®D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />[E�ji CHIMES (OPTIONAL) <br />o PUSHBUTTON SWITCH (OPTIONAL) <br />© CARBON MONOXIDE DETECTOR <br />sD SMOKE DETECTOR (ARC -FAULT) <br />sD c SMOKE / CARBON MONO. COMBO DETECTOR (ARC -FAULT) <br />TELEPHONE (OPTIONAL) <br />FvT <br />TELEVISION (OPTIONAL) <br />0 THERMOSTAT <br />Cp ELECTRIC METER <br />J� ELECTRIC PANEL <br />DISCONNECT SWITCH <br />® SPEAKER (OPTIONAL) <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />c /> CEILING MOUNTED INCANDESCENT LIGHT FIXTURE W/ <br />GJ ROUGH -IN FOR OPT. CEILING FAN <br />NOTES- <br />1. PROVIDE AND INSTALL GROUND FAULT CIRCUIT -INTERRUPTERS (GF.I.) AS INDICATED <br />ON PLANS OR AS ITEM NO.4 AND 5 BELOW INDICATES. <br />2. UNLESS OTHERWISE INDICATED, INSTALL SWITCHES AND RECEPTACLES AT THE <br />FOLLOWING HEIGHTS ABOVE FINISHED FLOOR <br />SWITCHES.... 42" <br />OUTLETS ..... 14" <br />TELEPHONE ... 14" (UNLESS ABV COUNTERTOP) <br />TELEVISION...14" <br />3. ALL SMOKE DETECTORS SHALL BE HARDWIRED INTO AN ELECTRICAL POWER <br />SOURCE AND SHALL BE EQUIPPED WITH A MONITORED BATTERY BACKUP. PROVIDE <br />AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS. <br />4. ALL 15A AND 20A RECEPTACLES IN KITCHENS, BLEEPING ROOMS, FAMILY ROOMS, <br />DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, SUNROOMS, RECREATION <br />ROOMS, CLOSETS, HALLWAYS, AND SIMILAR AREAS WILL REQUIRE A COMBINATION <br />TYPE AF.C.I. DEVICE AND TAMPER -PROOF RECEPTACLES PER N.E.C. 2014 406.12 AND <br />406.13 <br />5. ALL 15A AND 20A 120V RECEPTACLES LOCATED IN THE GARAGE AND UTILITY <br />ROOMS SHALL BE GF.C.I. PROTECTED (GF.U. <br />6. IT 15 THE RESPONSIBILITY OF THE LICENSED ELECTRICIAN TO ENSURE THAT ALL <br />ELECTRICAL WORK IS IN FULL COMPLIANCE WITH NF.PA 10, N.E.C. 2014, FB.C.R. - 6TH <br />EDITION (2011), AND ALL APPLICABLE LOCAL. STANDARDS, CODES, AND ORDINANCES. <br />1. EVERY BUILDING HAVING A FOSSIL -FUEL -BURNING HEATER OR APPLIANCE, <br />FIREPLACE, OR AN ATTACHED GARAGE SHALL HAVE AN OPERATIONAL CARBON <br />MONOXIDE DETECTOR INSTALLED WITHIN 10 FEET OF EACH ROOM USED FOR SLEEPING <br />PURPOSES. <br />8. ALARM5 SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WHEN <br />SUCH WIRING 15 SERVED FROM THE LOCAL POWER UTILITY. SUCH ALARMS SHALL HAVE <br />BATTERY BACKUP. COMBINATION SMOKE/CARBON MONOXIDE ALARMS SHALL BE <br />LISTED OR LABELED BY A NATIONALLY RECOGNIZED TESTING LABORATORY. <br />WALL <br />MNT. <br />W.P. <br />GF.I. <br />A/C <br />D ISCONN. <br />BEDROOM 2 <br />i ROUGH -IN <br />FOR OPT. <br />FAN/LIGHT <br />PRE -WIRE <br />ROUGH -IN <\ / <br />FOR OPT. <br />FANLIGHT i <br />PRE -WIRE </ J / <br />FAMILY ROOM <br />91 <br />-IN <br />/ROUGH <br />FOR OPT. <br />FAN/LIGHT <br />i <br />PRE -WIRE <br /></ J <br />OWNERS SUITE <br />W.P. <br />G.F.I. <br />BEDROOM 3 ' <br />ROUGH -IN I BATH 2 <br />FOR OPT. <br />FAN/LIGHT <br />J PRE -WIRE <br />111 <br />a <br />CAFE <br />PENDANT <br />(VERIFY <br />LOCATION) <br />RE <br />03ATH <br />W.P. <br />BEDROOM 4 <br />ROUGH -IN <br />FOR OPT. <br />FANLIGHT <br />PRE -WIRE J <br />E9 <br />G.C. VERIFY: LOCATION <br />OF DISPOSAL SWITCH <br />AND GF.I.OUTLET IS <br />UNDER SINK CABINET <br />ROUGH -IN <br />FOR OPT. <br />FANLIGHT <br />PRE -WIRE <br />J <br />FOYER <br />W.P. <br />GRI. <br />ENTRY <br />IIFff <br />II °Cieqo <br />GF <br />Uq L <br />'-_ _ — — <br />KITCHEN �u— <br />3 CAR GARAGE <br />I — — — — — — — — <br />ul <br />\ I GD. OPENERS FOR r <br />►a: u I I <br />O.E.------� <br />LIGHT AND <br />NWITCH I I \ <br />G.F.I. AT q <br />44" AFF. L <br />LAUND. G.F.I. <br />W.I.C. <br />FOR ALARM <br />SYSTEM <br />220 V. I GF.I_ <br />--� L_ JL _J ELEC. L----- <br />G.F.I. IRRIG. <br />PANEL At ,40 <br />ELEC. <br />METER <br />MAIN DISCONNECT METER <br />COMBO - SQUARE D 1 ( <br />REFER TO FLOOR <br />PLAN FOR NOTED MAIN DISC. <br />AMPS. REQUIRED <br />UNDERGROUND <br />SERVICE BY <br />POWER COMPANY <br />4/0 ALU. CABLE <br />A/C <br />DISC. <br />TYR ' 4 AND 12 COPPER TO <br />INSIDE LIGHTS AND OUTLETS <br />PANEL 'O COPPER TO <br />WATER HEATER <br />18 COPPER TO RANGE <br />14 COPPER TO 5/6" GROUND ROD <br />AL50 SERVICE TO BE BONDED <br />TO FOOTING STEEL <br />ELECTRICAL RISER DIAGRAM <br />NOTE: <br />ELECTRICAL MATERIALS AND INSTALLATIONS SHALL <br />COMPLY W/ APPLICABLE PROVISIONS OF THE NATIONAL <br />ELEC. CODE, LOCAL CODES, AND THE LOCAL POWER COMPANY. <br />ELECTRICAL PLAN - A I <br />Y <br />DAVIS BEWS <br />DESIGN GROVP <br />150 STATE STREET EAST <br />OLDSMA& FWRIDA 34677 <br />813. 925. L300 TEL <br />813.925.1800 FAX <br />W W W.DAVfSBEWS.CAM <br />TA 4PA • DENVER <br />EST.19" —> <br />1 <br />jr <br />001"A <br />O <br />00 <br />'—' <br />� qO <br />> <br />Lo <br />ED <br />o��Ln <br />CZ <br />�5 <br />Wo <br /><Q <br />wQ�w <br />J ozooo <br />Z U Z Q <br />U 0o�W <br />� � J <br />H a LLJ <br />o <br />oWLLN <br />�u� <br />U Zo <br />Qu <br />f z <br />z 0 <br />=5 gLij W N3 <br />�/ F_ <br />J <br />U cn O � J <br />Z WoQ <br />O a <br />0Wo <br />� O <br />a LL w aa0- <br />N owMuLO N z Zaw¢C�Za ^ Q° <br />Z N <br />w L0 N o <br />QOPzz <br />Do°Q <br />di W cy V z Z <br />00 <br />Q Q <Q� <br />ko Z Z �Jo <br />00 z g aim <br />J <br />O M a a ° <br />SCALE : AS NOTED <br />DATE : 10/4/2018 <br />VERSION NO. <br />loo <br />SHEET NO, <br />