My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
35933 Saddle Palm Way
Zephyrhills
>
Building Department
>
Building Plans
>
35933 Saddle Palm Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 7:50:12 AM
Creation date
2/19/2025 8:42:50 AM
Metadata
Fields
Template:
Building Plans
Street #
35933
Location
Saddle Palm Way
Contractor
Lennar Homes LLC
Building Plans - Permit #
20739
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
------------------------------------------------------ <br />--------------------------- <br />I I <br />I I <br />I I <br />I n I <br />I � I <br />ITYP.) (TYPJ <br />I I <br />I I <br />4'-0' <br />tib OFF -RIDGE �e <br />VENT <br />V <br />I <br />OFF -RIDGE z OFF -RIDGE <br />VENTVENT <br />I � I <br />SLOPE 5:12 _a SLOPE 5:12 <br />I I <br />I I <br />I � <br />I I <br />NOTE: <br />FLASHING SHALL BE INSTALLED AT WALL AND ROOF <br />I <br />INTERSECTIONS, AT GUTTERS, AT ALL CHANGES N ROOF <br />SLOPE OR DIRECTION, AND AROUND ROa OPENINGS. <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I <br />I I <br />I I <br />n I <br />u; I <br />oI I <br />I I <br />I <br />(TYP.) <br />� I <br />SLOPE 5:12 <br />I � I <br />— - - - - - - - - - - - - - - - - <br />------------------ <br />I r � <br />I (-F <br />--------------------------1 <br />O ROOF VENT 5CNEDULE O <br />Verify with Cmneral Contractor all roof vent <br />locations, quantities, and sizes. Roof vents shell <br />be Installed for a minimum of vented area as listed <br />below or equivalent system per 6TH ED. (2011) <br />FRC, RW6..2 <br />Roof vents or <br />°soffit Vent <br />Mark <br />Location <br />equal eyetem (sq. ink <br />(sq. In.) <br />RVI <br />Ma in Roof <br />194 <br />194 <br />M <br />ROOF FLAN <br />SCALE: 1/8'=1'-0' <br />12 <br />5� <br />STUCCO FINISH <br />SEE DET. B/SNI FOR <br />WEEP SCREED INF� - <br />RIDGE VENT <br />0 <br />SHINGLE ROOF PER SPECS. <br />'-2' <br />15NANCE OF PLAN5 FROM THIS DESIGNERS OFFICE SHALL NOT RELIEVE THE BUILDER OF <br />RESPONSIBILITY TO REVIEW AND VERIFY ALL NOTES, DIMENSIONS, AND ADHERENCE TO APPLICABLE <br />BUILDING CODES PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION, <br />ANY DISCREPANCY OF ERROR IN NOTES, DIMENSIONS, OR ADHERENCE TO APPLICABLE BUILDING <br />CODES SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGNERS OFFICE FOR CORRECTION BEFORE <br />COMMENCEMENT OF ANY CONSTRUCTION, <br />ANY REVISIONS OR CHANGES, NOT RELATED TO THE CORRECTION OF ERRORS THAT ARE MADE <br />AFTER THE FINAL PLANS HAVE BEEN COMPLETED 514ALL BE SUBJECT TO ADDITIONAL FEES, <br />RIDGE VENT SEE SHEET b FORT' MATERIAL NO <br />EGRE55 NOTE: <br />EACH BEDROOM MUST HAVE ONE WINDOW THAT <br />IF ANY MODIFICATIONS ARE MADE TO THESE PLANS BY ANY OTHER PARTY OTHER THAN THE * * * * * * COMPLIES WITH EGRESS CODES, IF THERE 15 NO <br />DESIGNERS OFFICE, THE DESIGNER SHALL NOT BE HELD RESPONSIBLE. ACCESS TO EXTERIOR THROUGH A DOOR THE <br />THICIQNE55 OF TEXTURED FINISH OVER <br />FRAME APPLICATION TO BE PER <br />FRC R103.1 <br />12 <br />5 F26 <br />T. WEE EL>�r. <br />0' 1' 2' <br />6'.SCORED BAND <br />T. BLOCK ELEV. 8'-0' F5 <br />F31F5 <br />T. WINDOW ELEV. 6'-V <br />F29' <br />- <br />STUCCO FINISH <br />`t <br />-FINISH FLOOR ELEV V-0' <br />- <br />5 RIDGE VENT <br />5ULDING 5EOTION <br />3N <br />SCALE: 1/8'=l'-0' <br />1 Fi\ONt ELE X ATION II II <br />SCALE: 1/4'=1'-0' <br />RIDGE VENT <br />�0 T. HEEL ELEV. <br />,b T. BLOCK ELEV_8'-V <br />F29 -� <br />�, F. FLOOR ELEV, 0'-0_ <br />12 12 <br />5 � OFF -RIDGE VENT � 5 <br />SHINGLE ROOF PER 6PEC5. <br />I- <br />1 <br />512 <br />RIDGE VENT <br />SHINGLE ROOF PER SPECS. <br />STUCCO FIN15H ❑ <br />-v� <br />SEE DET. B/SNl FOR <br />WEEP 5GREED INFO <br />SCALE: I/8'=1'-0' <br />SCALE: I/8'=1'-0' <br />F29 <br />F5 <br />5TUCC0 FINISH <br />T. BLOCK ELEV. 84' <br />- STUCCO FINISH <br />- SEE DET. B/SNI FOR <br />WEEP SCREED INFO <br />F. FLOOR ELEV. 0'-O' .L <br />DANSCO <br />ENGINEERING, LLC <br />P.O. BOX 3400 <br />Apollo Beach, Florida 33572 <br />p. 813.645.0166 <br />f. 813.645.9698 <br />www.danscoengineering.com <br />CA 25948 <br />o <br />N <br />zUj <br />E <br />OLn <br />o^ <br />rr w <br />z <br />0"'Mt,O <br />Q � J N <br />�wLL^ <br />z <br />°C ¢ o <br />I- <br />W <br />z <br />w <br />J <br />0 <br />w <br />z <br />Q <br />:0 <br />CQ <br />Q <br />w <br />Q <br />LU <br />Ou'U <br />I — <br />0 <br />_C <br />J <br />''W^^ <br />V w <br />Q <br />-�O <br />Q <br />Q <br />U',o(D <br />(y) <br />Uj <br />L0 <br />U <br />S <br />CM <br />(y) <br />1' <br />TO THE BEST OF THE ENGINEER'S <br />KNOWLEDGE AND BELIEF, THE STRUCTURAL <br />PLANS AND SPECIFICATIONS COMPLY WITH <br />61H EDITION (2017) FLORIDA RESIDENTIAL <br />BUILDING CODE, SECTION R301 FOR <br />140 MPH (Vasd=108MPH), 3 SEC. GUST, <br />EXPOSURE "C" ENCLOSED (INTERNAL <br />PRESSURE COEFFICIENT = 30.18) WIND ZONE <br />THIS DRAWING AND DESIGN IS VALID FOR 12 MONTHS <br />AFTER THE DATE TT IS SIGNED AND SEALED. <br />SIGNED AND SEALED FOR THE STRUCTURAL PORTION <br />OF THIS DRAWING ONLY. <br />® 2018 LENNAR CORP.-THIS PLAN MAY NOT BE <br />REPRODUCED IN ANY MANNER WITHOUT WRITTEN <br />CONSENT FROM LENNAR CORPORATION. <br />0 2018-THESE DRAWINGS AND DESIGNS ARE THE <br />JOINT PROPERTY OF DANSCO ENGINEERING. LLC AND <br />THE CLIENT ON THIS PROJECT, ANY REPRODUCTION <br />OR UNALJTHOR12ED USE IS PROHIBITED. <br />REVISION: <br />DATE DESCRIPTION - <br />12.12.17 1.00 6-TII FC(2017rFBC -- <br />I�PDATES <br />07 31 18 1.01 ELFV LAY UT <br />REVISED <br />12 <br />5 <br />VERSION NO. 1.01 / 07.31.18 <br />SHEET TITLE: <br />ELEVATION "A" EXTERIOR <br />ELEVATIONS & ROOF PLAN <br />SHEET INFORMATION: <br />ISSUANCE OF PLANS FROM THIS DESIGNERS OFFICE SHALL NOT RELIEVE THE BUILDER OF JOB NO.: 381320 <br />RESPONSIBILITY TO REVIEW AND VERIFY ALL NOTES, DIMENSIONS, AND ADHERENCE TO APPLICABLE DATE ISSUED: 10.09.18 <br />BUILDING CODES PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION. <br />ANY DISCREPANCY OF ERROR IN NOTES, DIMENSIONS, OR ADHERENCE TO APPLICABLE BUILDING DRAWN BY: JH <br />CODES SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGNERS OFFICE FOR CORRECTION BEFORE REVIEWED BY: TH <br />COMMENCEMENT OF ANY CONSTRUCTION. <br />ANY REVISIONS OR CHANGES, NOT RELATED TO THE CORRECTION OF ERRORS THAT ARE MADE <br />AFTER THE FINAL PLANS HAVE BEEN COMPLETED SHALL BE SUBJECT TO ADDITIONAL FEES. <br />IF ANY MODIFICATIONS ARE MADE TO THESE PLANS BY ANY OTHER PARTY OTHER THAN THE 3A <br />DESIGNERS OFFICE, THE DESIGNER SHALL NOT BE HELD RESPONSIBLE. <br />r- <br />04 <br />LO <br />O <br />I <br />
The URL can be used to link to this page
Your browser does not support the video tag.