My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
35941 Saddle Palm Way
Zephyrhills
>
Building Department
>
Building Plans
>
35941 Saddle Palm Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 11:59:07 AM
Creation date
2/19/2025 8:43:01 AM
Metadata
Fields
Template:
Building Plans
Street #
35941
Location
Saddle Palm Way
Contractor
Lennar Homes LLC
Building Plans - Permit #
20744
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br />- - - - - - - - - - - - <br />_ FOLD UP WEATHER <br />RESISTIVE BARRIER 8 <br />I I TEMPORARILY SECURE <br />WEATHER <br />I FRESISITIVE <br />BARRIER <br />TAPE <br />I I <br />IA39EMBLED WINDOW , <br />I 2 <br />I I <br />I <br />I <br />I <br />I I <br />HEAD FLASHING TIE-IN INSTRUXTIONS: <br />1. Cut, fold up & temporarily secure weather resistive <br />THESE DETAILS ARE GENERIC AND barrier above header to allow for flashing <br />installation <br />EXTERIOR <br />SHEATHING <br />WEATHER <br />RESISITIVE <br />BARRIER <br />SELF -ADHERED FLASHING <br />WOOD FRAME CONSTR. <br />SELF -ADHERED FLASHIN <br />BY LAPPING DOWN <br />OVER RIM JOIST AND UP <br />WALL BY 6 IN. <br />SEAL TOPS OF JOISTS <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />WEATHER RESISTIVE <br />BARRIER <br />DOOR ROUGH OPENING <br />3/4"-V BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />i� SELF -ADHERED FLASHING <br />SUBFLOOR <br />RIM JOIST <br />WINDOW UNIT <br />SLOPE <br />0.3 in : 12.0 in <br />(0.6 cm: 30.5 cm) <br />SELF -ADHERED FLASHING <br />EXTERIOR <br />CEMT. FIN. <br />BUILDING PAPER <br />NTH <br />MEANT TO SHOW GENERAL FLASHING 2. Self -adhered flashing plus head flashing under <br />AND WATERPROOFING METHODS TO weather resistive barrier <br />BE USED. 3. Fold weather resistive barrier back over head <br />flashing and seal with tape 2 2 G <br />SELF -ADHERED FLASHING Scale: NTS <br />FLANGED WINDOW SELF -ADHERED FLASHING SELF -ADHERED FLASHING <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER W P O 1 EXTERIOR DOOR WITH DECK - SECTION A W P 02 CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER W P03 <br />EXTERIOR SHEATHING MECHANICALLY FASTEN IF RUBBERIZED ASPHALT <br />- <br />EXTERIOR SHEATHING 3/4%1" BEAD OF CONSTR. NEEDED IN CORNERS RUBBERIZED ADHESIVE <br />ADHESIVE TO BE APPLIED UNDER INSTALL SELF -ADHERED THROUGH SELF -ADHERED ASPHALT ADHESIVE <br />FLASHING JAMB 8 HEAD <br />THRESHOLD OF DOOR AND RETURN FLASHING, SEE FLASHING SELF -ADHERED FLASHING <br />.. :.......:. UP JAMB 6". USE LIQUID NAIL BRAND FLANGED WINDOW <br />OR EQUAL WEATHER PROOF CAULKING <br />SEE DETAIL WP01) <br />REFER TO TECHNICAL <br />LETTER ON CHEMICAL SCORED <br />.......... <br />COMPATIBILITY ... RELEASE PAPER <br />SELF -ADHERED FLASHING <br />- - SELF -ADHERED FLASHING, r (BEFORE FOLDING, SCORE <br />/ EXTEND A MINIMUM 6" RELEASE PAPER TO EXPOSE <br />VERTICALLY FROM ADHESIVE AS SHOWN) <br />................. <br />e o <br />BOTTOM OF <br />THRESHOLD <br />SECTION -A (SEE DETAIL WP02)-11 <br />DO NOT FLASH OVER <br />BOTTOM NAILING <br />FLANGE <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />� Lf1J1111VV <br />SELF -ADHERED FLASHING <br />DECK JOIST <br />NOT USED <br />NAILING FLANGE <br />1 L/1JI III�LI <br />SELF -ADHERED FLASHING <br />E <br />4M <br />Q <br />WP07 <br />WP10 <br />SELF -ADHERED FLASHING <br />SEAL TOPS OF JOISTS <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />J <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />SELF -ADHERED FLASHING <br />3" MIN <br />8 2 <br />WP05 <br />SELF -ADHERED FLASHING <br />PATCH <br />SELF -ADHERED FLASHING <br />SELF -ADHERED FLASHING <br />OUTSIDE CORNER <br />NOT USED <br />WP11 <br />a <br />SELF -ADHERED FLASHING <br />INSIDE CORNER <br />Ground �+-- <br />FOUNDATION WEEP SCREED <br />NOT USED <br />Water Resistant Barrier <br />Lath <br />Sheathing <br />Stucco <br />WP09 <br />WP 12 <br />FLASHING REQUIREMENTS <br />R609.1 Flashing, Sealants and Weatherstripping. Flashing and sealants for exterior windows shall comply with Section R703.8 <br />R703.2 Weather -resistant sheathing paper. One layer of No.15 asphalt felt, free from holes and breaks, complying with ASTM D 226 for Type 1 felt or <br />other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 inches (51 mm). Where joints occur, felt shall be lapped not less than 6 inches (152 <br />mm). The felt or other approved material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner <br />to meet the requirements of the exterior wall envelope as described in Section R703.4 <br />Exception: Omission of the water -resistive barrier is permitted in the following situations: <br />1. In detached accessory buildings. <br />2. Under exterior wall finish materials as permitted in Table R703.4 <br />3. Under Paperbacked stucco lath when the paper backing is an approved water -resistive barrier. <br />R703.4 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into thewall cavity or <br />penetration of water to the building structural framing components. Self -adhered membranes used as flashing shall comply with AAMA 711. The <br />flashing shall extend to the surface of the exterior wall finish. Approved corrosion -resistant flashings shall be installed at all of the following locations: <br />1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of he exterior wall finish or to the <br />water -resistive barrier for subsequent drainage. Flashing at exterior window and door openings shall be installed in accordance with one or more of the <br />following or other approved method: <br />1.1 The fenestration manufacturer's written flashing instructions. <br />1.2 The flashing manufacturer's written installation instructions. <br />1.3 In accordance with FMA/AAMA 100, FMA/AAMA 200, or FMA/WDMA 250. <br />1.4 In accordance with the flashing method of a registered design professional. <br />2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under stucco copings. <br />3. Under and at the ends of masonry, wood or metal copings and sills. <br />4. Continuously above all projecting wood trim. <br />5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />6. At wall and roof intersections. <br />7. At built-in gutters. <br />R703.6.2.1 Weep Screeds <br />A Minimum 0.019-inch (No. 26 Galy. sheet gage), corrosion -resistant weep screed or plastic weep screed, with a minimum vertical attachment flange of <br />31 /2" shall be provided at or below the foundation plate line on exterior stud walls in accordance with ASTM C 926. <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS <br />TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND <br />ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2.1 <br />Detail Instructions <br />Refer to the number marked as #Oin each detail that corresponds to the numbered items in the list of <br />instructions below: <br />1. Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water shedding laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, embedded in the adhesive layer) - <br />for ease of installation and to minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and adhere to substrate using a square <br />piece of flashing material (611 x 6" Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to fit tight to corner <br />8. Mechanically fasten as necessary <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />Cement <br />Plaster <br />over block <br />1 st floor <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />-7/16" O.S.B. <br />sheathing <br />- Metal <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain <br />Bottom of <br />Weep Screed <br />1 1/2"to 2" <br />Above Roof <br />Sheathing <br />If <br />Note: <br />The building paper and metal lath must be <br />installed over the top of the weep screed. <br />WEEP SCREED DETAIL <br />SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTM C1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside corner will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />O <br />ZcV <br />O vN <br />>V)Mo <br />M <br />aU) M`n <br />Zo0 <br />to O <br />Q LZ L <br />CL .-. <br />ce V M '-4 <br />CL <br />Q <br />Z <br />WJ <br />J <br />� <br />Z <br />U. <br />O <br />U) <br />of <br />W <br />LU <br />SCALE : <br />AS NOTED <br />DATE : <br />05-07-2018 <br />SHEET NO. <br />P <br />
The URL can be used to link to this page
Your browser does not support the video tag.