Laserfiche WebLink
rn <br />LO <br />C) <br />CV <br />rLO <br />— <br />I <br />w <br />0 <br />0 <br />rn <br />rn <br />0 <br />Zi <br />CID <br />00 <br />co <br />w <br />E <br />0 <br />s <br />ry <br />co <br />bo <br />0 <br />F- <br />0 <br />I- <br />3 TAB SHINGLES. ROOF — <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />5' RIDGE VENT <br />HEEL HEIGHT _ <br />T.O.P <br />HDR. HGT. <br />8' RIDGE VENT <br />--------------- --- ------------------ <br />12 CJ CJ <br />2nd FIN. FLR. 3.5 �/7 <br />T.O.M. CJ / WEEP r- <br />HDR HGT <br />F. FL. <br />12 <br />�5 <br />TEXTURED <br />CEMENTITIOUS <br />FINISH OVER <br />SHEATHING <br />(TYP.) <br />12 <br />Q 3 <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />txterlor uovering <br />R703.6 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.6.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.6.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.6.3 Water- Resisitive Barriers. <br />Water-resisitive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paperbacked <br />stucco lath) over an approved synthetic house wrap. <br />R703.8 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry contructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />FRONT ELEVATION B <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />— <br />SCALE: 1 /4"-1 r-0" <br />but no more than 50% of the required ventilation is provided in the upper portion <br />the space to be ventilated. Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />*'CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN** <br />(Values to be verified with Manufacturer Specifications) <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. <br />-------------------------------------c '-0"-F---- <br />TEXTURED <br />CEMENTITIOUS <br />FINISH ON C.M.U. <br />(TYP.) <br />RIGHT ELEVATION - B <br />SCALE: 1 /4"=1 r-0" <br />*If not enough vented soffit is provided due to fire protection, the contractor shall use <br />following approved vents: <br />• LOMANCO DECK -AIR (Shingle Roof) - 9 SQ. IN. OF NET FREE AREA / FT. <br />**Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 9 = Linear Ft. of Deck -Air Needed) <br />U' <br />z ch <br />—olot <br />z� <br />lo"I <br />z <br />4-1 <br />Cl- <br />Iff"ol <br />U, z <br />V) CD <br />w <br />(DIM <br />V — <br />O w <br />m <br />Ln = <br />o <br />U <br />o co <br />m N <br />W <br />E <br />0 M <br />cc cMM <br />N-0 co <br />S N <br />0 p a <br />CJ a) <br />"� <br />ct-, y <br />Q o) <br />0 Y t` <br />C:) <br />rn <br />rn Q o <br />B D® <br />n _�. <br />_ N <br />cc-, <br />U) F—Z Lu <br />o.'s <br />inw <br />UJ <br />io NJ `� <br />Z p <br />z M E cp Q <br />IUL <br />zP M NI U <br />(7 A <br />�t� �Fpf�P,?IIJI U o <br />�Ahq <br />ti•` .FISSEt�G.CO . llo ❑ <br />} t a`'•, •Y• ••• <br />' �� �� <br />�� <br />D � O� � : z <br />%� c � :•fit :: <br />,ram ••'•,........'. �� ``t. <br />��i O F E SS�0``,�Ryy�.���� <br />° rlaflllti\ld` <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 2001 Tampa, FL 33607 <br />www.LennarTampa.com <br />0 <br />Z <br />3Q <br />z¢a <br />} <br />< of <br />wctr <br />z <br />O <br />Uzoo <br />ia?Z <br />J <br />U Cwo <br />J <br />w <br />Zo <br />z <br />_ <br />LU <br />Z w <br />5 <br />1 <br />U) <br />N <br />Z <br />a <br />�Z <br />O <br />Z <br />� <br />c <br />N <br />M <br />Q <br />I— <br />2E <br />0 <br />Y <br />o <br />z <br />O <br />N <br />z <OZ <br />LL <br />wW-a <br /><¢-ci� <br />Q <br />Lr) <br />z <br />z <br />fV <br />0 <br />ral�Z <br />UJ <br />J <br />ft,n <br />rl <br />LLI <br />a u- <br />cnoYa <br />W <br />�O <br />¢ <br />z <br />"Qz <br />z <br />z <br />� <br />V)ZS <br />ao <br />m <br />00 <br />= <br />a <br />SCALE : AS NOTED <br />DATE : 10/2/2018 <br />TECH: MJAM ES <br />VERSION NO. <br />4n2 <br />SHEET NO. <br />3.1 <br />