My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
35949 Saddle Palm Way
Zephyrhills
>
Building Department
>
Building Plans
>
35949 Saddle Palm Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 12:56:22 PM
Creation date
2/19/2025 8:43:29 AM
Metadata
Fields
Template:
Building Plans
Street #
35949
Location
Saddle Palm Way
Contractor
Lennar Homes LLC
Building Plans - Permit #
20741
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
c�0 <br />m <br />Q <br />r" <br />N <br />0 <br />r <br />a <br />rZ <br />i <br />ELECTRICAL SPECIFICATION <br />200A INDOOR PANEL <br />CENTER <br />NOTES: <br />#14 copper to lights & outlets <br />ELECTRICAL CONTRACTOR <br />NEMA 1 <br />200 AMP <br />10 #12.copper to 20 amp Ckts <br />MUST VERIFY WITH THE <br />01 #10-2 copper to WH <br />SPECIFICATIONS FOR THE TYPE <br />10 #10-3 copper to Dryer <br />OF FIXTURE TO BE USED. LIGHT <br />—r <br />FIXTURES SHOWN ARE FOR <br />METER <br />LOCATION PURPOSES. <br />MAIN O <br />2/0 or 4/0 SER Alu <br />200 amp <br />IF <br />150 amp <br />POWER CO. FEED <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 14, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />----------------------------------------------- <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCt's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory, <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The Width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FfF <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.t. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />24 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />}� <br />FLUORESCENT LIGHT FIXTURE <br />Q <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />�D <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />Tq <br />TELEVISION (OPTIONAL) <br />© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />PM <br />ELECTRIC METER <br />owl <br />PANEL <br />—�I <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />6% <br />/�J <br />G <br />ROUGH -IN FOR OPT. CEILING FAN <br />�41 � IL� <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G r J <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />r--------------------------------------------------------------------------------------------------- I <br />I I <br />I I <br />I I <br />I I <br />I 1 <br />I I <br />I I <br />1 I <br />I f <br />I 1 <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />1 I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />j I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I 11 1 1 17BF�LO)Vi <br />-�LIGHT W/ I I I �dH SWITCH IN1I I I I II\ I I I I I ATTIC F\ 1 t r t r <br />I <br />I r---t <br />I <br />BEDROOM 4 I �� <br />-Y�f :-1: C�. <br />ROUGH -IN FOR 1 <br />OPT. CLG. FAN/ 1 <br />LIGHT PRE -WIRE <br />S.D. <br />J <br />i <br />, <br />- <br />BEDROOM 5; <br />p <br />/� <br />Jr <br />F` ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />VP <br />II j <br />II/ � <br />I I \\ <br />BONU ROOM <br />r <br />BEDROOM 2 <br />q <br />_ * 1 <br />6 <br />/ ROUGH -IN FOR / <br />/ OPT. CLG. FAN/ <br />/ LIGHT PRE -WIRE <br />S.D.— <br />/�! / m <br />If <br />/J � M <br />I ROUGH -IN FOR <br />I <br />I OPT. CLG. FAN/ <br />1 LIGHT PRE -WIRE <br />I <br />I <br />1 <br />BATH 2 _7 <br />r_ -- <br />T <br />o <br />r11"NIMA <br />UPPER ELECTRICAL PLAN <br />SCALE: %4"=1'-0" <br />0 <br />M <br />0 <br />— o <br />Z <br />ri <br />U) <br />O w <br />F- <br />N <br />�N r- <br />� <br />o 0 <br />CD N <br />t3J E <br />B — <br />0[2 <br />e) (h <br />0)a Co CO <br />- —' <br />'S cMM <br />OoN <br />t? <br />�LL00 <br /><o <br />) <br />co&o <br />.r, 0 <br />Q o <br />A <br />BID <br />N C B D C <br />N N <br />O V� oo <br />N M= Z" <br />Z W` ��oZ � Z"N c9 <br />'Ill <br />A� 1—d <br />ice/ [n l; p s W W <br />W <br />101U -cp E � <br />v <br />m <br />LAWZ MEm <br />�,. � rn�Ni4 a A <br />44 N ¢ <br />W x A <br />WWW.FDSENG.COM <br />00 <br />0 <br />N <br />0 <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />0 <br />Z <br />1Q <br />Za <br />�a <br />o48c <br />�Z< <br />�0WZZ <br />Q <br />z <br />ate-' <br />J <br />o <br />Q <br />U <br />ZZ <br />> U <br />ZZ <br />C) <br />L <br />g <br />0 <br />v� <br />N <br />w <br />O <br />�' <br />—� <br />W <br />U <br />(� <br />N <br />W <br />rr <br />9 <br />8� <br />�o <br />M <br />w <br />Q�P <br />®_ <br />RNA <br />� <br />rQo <br />Z <br />z <br />LU <br /><W <br />Q <br />L r) <br />u- <br />Z <br />Z <br />f4 <br />fV <br />W <br />In <br />W <br />15-zo <br />J <br />ri <br />tJ..l <br />Q <br />5- <br />Z <br />n F <br />'wo <br />Z <br />t <br />a o <br />o0 <br />Ho <br />m <br />l!7 <br />z <br />Q7 <br />W <br /><z <br />SCALE : AS NOTED <br />DATE : 10/2/2018 <br />TECH: MJAMES <br />VERSION NO. <br />4.2 <br />SHEET NO. <br />4.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.