My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
35973 Saddle Palm Way
Zephyrhills
>
Building Department
>
Building Plans
>
35973 Saddle Palm Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 1:39:23 PM
Creation date
2/19/2025 8:43:56 AM
Metadata
Fields
Template:
Building Plans
Street #
35973
Location
Saddle Palm Way
Contractor
Lennar Holmes LLC
Building Plans - Permit #
20606
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TYP @ 2 STORY <br />J <br />S6 <br />50'-0" <br />4'-2" J, 13'-11" 5'-2" 18'4" 8'-5" <br />H B O <br />I � I <br />6068 S.G.D. <br />TEMP. <br />O <br />35-SH <br />O <br />35-SH <br />O <br />e <br />EGRESS <br />C <br />I a FIBERGLASS <br />SURROUND <br />T o <br />O; 'BEDROOM 2 <br />8'-8-- CLG. <br />F MIL RM PLUMING BATH CARPET <br />8'-8" CLG. STACK II�E <br />I CARPET0 <br />2,_1$" (7 3, 6" 6'-102-1" =a <br />MW <br />BI FORD `r <br />1 �2) 2068 <br />2668 I -FOLD <br />9I I AHU <br />- I I - I I U) <br />(3)2X4#2 o QI I I05 <br />I SPF STUDS <br />+42" SLOPING N =I I 2---- - <br />HAL WALL cn '-8" CLG. R& <br />I I I I I I 1 I I H 1 CC <br />(4) 2 X 4# 2 UP 16R I I I I I I I I I CC =^ S3 W.H• <br />SPF STUD I I I I (3) 2 X 4# 2 <br />I 1 I I I I I I I S3 SPF STUDS cn 2 X 4# 2 SPF <br />1 1 21 31 41 51 61 71 81 9 1 01 11 STUDS @ 16" O.C. O <br />G.T. -III BUILDER TO PROVIDE <br />APPLIANCE <br />PROTECTION WHEN <br />2 x 4 # 2 SPF EDGE OF SLAB 2" CC REQUIRED PER FBC <br />STUDS @ 16" O.C. BEYOND WALL S3 <br />3PF5TU S S FSTU S <br />3 CAR <br />GARAGE <br />CC 8'-8" CLG. <br />S3 <br />HDR AT 8'_0" <br />- - 2X4#2SPF o0 <br />STUDS @ 16" O.C. <br />---------- --- -------10'-10" -0„ 10'-78" 1'-102� 5,�„2'_9�'- 8alp <br />T <br />CAFE <br />8'-8" CLG. <br />TILE <br />j <br />I <br />i II r <br />I D.W. I� <br />L--Ji 1 <br />1 1 <br />O I I <br />I <br />I I <br />0 1 1 <br />I I <br />IL_ _ <br />I <br />� <br />O` <br />O I <br />I" <br />1 <br />w <br />Z <br />Q <br />3 <br />z <br />_ <br />!I <br />o <br />OPT. KITCHEN <br />- _ <br />- <br />TILE <br />s' <br />-�----� ---�-' <br />I <br />i I <br />=w 8„ =W <br />`n= Mo ' <br />i°� j TILE t°CD 05 I 2668 <br />- I BI-FOLD <br />5-SH I <br />16" DEEP 1 <br />72'-15'172 <br />N <br /><V <br />°° <br />� <br />N <br />FLEX al <br />III <br />8-8" CLG. <br />CARPET olll <br />=II <br />lil <br />I <br />NOTE: FINISHED WALLS <br />TO BE FLUSH. VERIFY IN <br />FIELD. <br />O OcoI <br />25-SH 25-SH <br />EGRESS <br />Y <br />i 52' <br />_ I i <br />- - - - - - - - - - - - - - I I <br />I I I I <br />I I I I <br />I I I <br />i I I I <br />I D <br />I S3 1 1 16 x 7 OVERHEAD DOOR <br />I <br />1 I - - - - - - - - - - - - - - - - - - --- ----------- <br />----------- <br />I <br />I 8 x 7 OVERHEAD DOOR I O <br />---------------- <br />- - H 2N9. FLOOR ABV. <br />= <br />8'- <br />"CLG. <br />TILE <br />I <br />00 <br />I <br />_ <br />O co <br />E Y- <br />2'-0" <br />6-6" <br />3'-10" <br />2'-0" <br />4'-4" <br />2'-0" <br />" <br />8'-0" <br />2'-0" <br />TYP @ <br />GARAGE <br />16-0" <br />2'-0" <br />12'-4" <br />8'4" <br />10'-8" <br />18'-8" <br />50'-0" <br />TYP @ 2 STORY <br />J <br />S6 <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H 1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) -1 3/4" X 11 1/4 LVL <br />2.0E Fb=2600 PSI <br />H6 <br />(2) - 1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2600 PSI <br />H7 <br />(2) -1 3/4" X 16" <br />LVL 2.0E Fb=2600 PSI <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2600 PSI <br />(2) - 2X4 #2 SYP W/ 1/2" Follow Q/S4. See Plan for <br />R.A.G. FLITCH PLATE Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection. <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection. Openings from a private garage <br />directly into a room used for sleeping purposes shall not be <br />permitted. Door between garage and residence shall be equipped <br />with solid doors not less than 1 3/8" in thickness, solid or <br />honeycomb -core steel doors not less than 1 3/8" thick, or <br />20-minute fire -rated doors. <br />R302.5.2 Duct Penetration. Ducts in the garage and ducts <br />penetrating the walls or ceilings separating the dwelling from the <br />garage shall be constructed of a minimum No. 26 gage (0.48 mm) <br />sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl <br />duct board, or other approved material and shall have no openings <br />into the garage. <br />R302.5.3 Other Penetrations. Penetrations through the separation <br />required in Section R302.6 shall be protected as required by <br />section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated from the dwelling as per the <br />following: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies -Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills. <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools, Section R4501.17.1.9 <br />All doors and windows providing direct access from the home to <br />the pool shall be equipped with an exit alarm complying with UL <br />2017 that has a minimum sound pressure rating of 85 db at 10 <br />feet. Any deactivation switch shall be located at least 54 inches <br />above the threshold of the access. Separate alarms are not <br />required for each door or window if sensors wired to a central <br />alarm sound when contact is broken at any opening. <br />M1507.2 Recirculation of Air. <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />recirculated within a residence or to another dwelling unit and shall <br />be exhausted directly to the outdoors. Exhaust air from bathrooms <br />and toilet rooms shall not discharge into an attic , crawl space or <br />other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />OPENING PRESSURES <br />ENCLOSED-EXPOSURE"C" <br />rA <br />+29.7 / -30.8 <br />© <br />+29.7 / -39.2 <br />© <br />+28.3 / -30.8 <br />OD <br />+28.3 / -36.4 <br />DE <br />+26.6 / -28.0 <br />OF <br />+26.6 / -32.2 <br />SEE SN SHEET OH SEE SN SHEET <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />1 +34.0 / -44.8 <br />WALL LEGEND <br />TYP. 2x FRAME WALL <br />1 BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR BEARING <br />ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND <br />REQUIRES NO UPLIFT CONNECTORS TO FLOOR <br />SYSTEM <br />AREA TABULATION "A" <br />1ST FLOOR LIVING AREA 1358 <br />2ND FLOOR LIVING AREA 1996 <br />LIVING TOTAL 3354 <br />GARAGE 644 <br />ENTRY 32 <br />TOTAL AREA 4030 <br />INSULATION REQ. <br />LOCATION I R-VALUE / TYPE <br />EXT CONC WALL <br />R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 <br />R-11/R-13 KRAFT FACED <br />PLAN <br />q <br />EXT FRAME 2 x 6 <br />R-1KRAFT FACED <br />FIRST <br />FLOOR <br />CONDITIONED CEILING <br />R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />I GARAGE SEPARATION JR-11/R-13 KRAFT FACED <br />SCALE: )/4"=1 '-O"r (GARAGE / LIVING) <br />0 <br />z M <br />0 <br />- � <br />z <br />z <br />Q <br />cn U <br />w <br />� p <br />• O W <br />tL <br />o <br />m N <br />W <br />E <br />�p <br />U <br />M Q7 M <br />N -0 M <br />= Q? <br />`7i <br />_oo O <br />L' eo <br />U <br />C o <br />oo <br /><C rn <br />o 0 <br />v av <br />rn < o <br />B D® <br />N JC <br />PY <br />N �O <br />N <br />f7 O) <br />Z o ., o <br />M N 6 0 <br />Z W c" <br />'S <br />a! C, <br />W `� �; <br />Z V'�LLL a <br />OW'S (g <br />0 <br />2a <br />WLL a �' f/ f <br />X7e��7+ <br />r0 Np <br />FDSE .CO <br />' •" / 1 W <br />VV <br />,i <br />A\ 0. <br />e. <br />o <br />U �O• <br />" rL <br />ROrESS10.0o <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />LE N NAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />oz <br />U, <br />f¢ <br />w¢c� <br />oo <br />oozes <br />z <br />zz <br />w <br />aW0� <br />O <br />/ \ <br />J <br />0 <br />� <br />zz <br />^ <br />LL <br />z <br />}o <br />5 <br />z <br />O <br />z <br />�� <br />Z <br />O <br />C <br />�¢ <br />W <br />U <br />U-) <br />rn <br />z <br />0 <br />4 <br />os <br />J <br />¢US <br />00� <br />N <br />z Z;� <br />w <br />Q <br />N <br />o�� <br />z <br />z <br />N <br />LL O R <br />�ao�Z <br />J <br />Ln <br />LLJ <br />< z <br />•--I <br />UJI <br />U <br />a <br />Lr) <br />p1 <br />2:F <br />Q <br />z <br />ILUQz <br />r-I <br />z <br />o o S <br />Cal <br />0 <br />Ll <br />06 <br />zLU <br />_ <br />¢f <br />rl <br />a <br />to <br />s <br />SCALE : AS NOTED <br />DATE : 7/30/2018 <br />TECH: MJAM ES <br />VERSION NO. 10 <br />O <br />SHEET NO. <br />1.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.