My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
35973 Saddle Palm Way
Zephyrhills
>
Building Department
>
Building Plans
>
35973 Saddle Palm Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 1:39:23 PM
Creation date
2/19/2025 8:43:56 AM
Metadata
Fields
Template:
Building Plans
Street #
35973
Location
Saddle Palm Way
Contractor
Lennar Holmes LLC
Building Plans - Permit #
20606
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
N <br />UCL <br />QSM <br />//�� 0- <br />\V <br />C 0 cv � <br />® O N <br />March 20, 2018 0 O <br />� O I.L <br />O Co �0 > <br />Re: Wood Construction Connector Compliance for 2015 international Codes & 2017 Florida Codes -� O O <br />N L <br />To Whom It May Concern: o ' co CU Q <br />Section 23035 of the 2015 International Building Code (IBC) and 2017 Florida Building Code (FBC) specifies that (- � -� �/) <br />joist hangers shall be tested per ASTM D7147 Testing and Establishing Loads of Joist Hangers. Previous versions of <br />the IBC and FBC required testing to comply with ASTM D1761 Test Method for Mechanical Fasteners in Wood. Both <br />methods determine a connector's allowable load as the lowest of the following: <br />1. Lowest ultimate of three tests (or average of 6) with a safety factor of 3 <br />2. Average load at 1/8-inch deflection <br />3. Calculations per American Wood Council National Design Specification for Wood Construction (NDS) <br />The primary changes in ASTM D7147 are requirements to measure properties of the tested materials, such as steel <br />strength, fastener strength, and wood specific gravity. The tested ultimate loads must be adjusted when tested <br />material properties exceed the specified properties. <br />ICC Evaluation Services (ICC-ES) revised AC13 Acceptance Criteria for Joist Hangers and Similar Devices in <br />October 2016 to incorporate a methodology to evaluate products to the 20151-Codes. Simpson Strong -Tie is working <br />on re-evaluating wood construction connector loads to the new standard to update our product evaluation reports to <br />the 2015 I -Codes. As soon as the updated evaluation reports are completed, we will apply for Florida Product <br />Approvals. <br />However; reevaluating a large number of products will take time. While manufacturers work with product certification <br />agencies to update their wood connector evaluation reports, we recommend that building departments under the <br />2015 I -Codes and 2017 Florida Codes continue to accept code reports showing compliance to the 2012 and 2014 <br />editions, respectively, until July 2018. <br />The information in this letter is valid until 6/3042018 when d will be re-evaluated by Simpson Strong -Tie. Please visit <br />www.stronatie.com for additional pertinent information. If you have questions or need further assistance regarding <br />this matter, please contact the Simpson Strong -Tie Engineering Department at 800,999.5099. <br />Sincerely, <br />SIMPSON STRONG -TIE COMPANY INC. <br />Keith Cullum, P.E., LEED AP dwBDVJ <br />Engineer, Southeast U.S. Branch <br />Page 1 of 1 <br />Simpson Strong -Tie Company Inc. 2221 CountryLane McKinney, TX 75099 Phom. 972.542.0326 Fax 972.542.4139 wme.stiunatie.cmn <br />W^1 <br />W <br />z �_ <br />O <br />L <br />O <br />O <br />V! <br />U M <br />0- <br />L <br />W <br />Q W <br />z J <br />z <br />J <br />SHEET NO. <br />PA 1.0 <br />�� If!',,. � �� _ r'" „s <br />3N'1 <br />.$... .• .- 'o--sr � <br />' , -YY �.�'.Ua^ 5" iz'�.�w.�t .. # <br />`r <br />� <br />v <br />;�' �4Y?i <br />A3 <br />FL17244.1 <br />ESR-3455 <br />A23 <br />FL10446.2 <br />ESR-2806 <br />HD210-2 <br />FL17232.3 <br />ESR-3445 <br />HU210.2 <br />FL10856.4 <br />ESR-2549 <br />HD212-2 <br />FL17232.3 <br />ESR-3445 <br />HU212-2 <br />FL10856.4 <br />ESR-2549 <br />H0218 <br />FL17232.3 <br />ESR-3445 <br />HU216 <br />FL10856.5 <br />ESR-2549 <br />HD216-3 <br />FL17232.3 <br />ESR-3445 <br />HU2163 <br />FL10856.1 <br />ESR-2549 <br />HD26 <br />FL17232.2 <br />ESR-3445 <br />HU26 <br />FL10856.3 <br />ESR-2549 <br />HD28-2 <br />FL17232.3 <br />ESR-3445 <br />HU28-2 <br />FL10858.4 <br />ESR-2549 <br />HD410 <br />FL17232.4 <br />ESR-3445 <br />HU410 <br />FL10856.9 <br />ESR-2549 <br />HD412 <br />FL17232.4 <br />ESR-3445 <br />HU412 <br />FL10858.9 <br />ESR-2549 <br />HD610 <br />FL17232.4 <br />ESR-3445 <br />HU810 <br />FL10856.10 <br />ESR-2549 <br />HD0410 <br />FL17241.7 <br />ESR-3444 <br />HUC0410 <br />FL11468.11 <br />SIM200804 <br />HGA10 <br />FL17699.1 <br />Evaluation Report <br />HGA10KT <br />FL11470.4 <br />SIM200803 <br />HGAM10 <br />FL17699.1 <br />Evaluation Report <br />HGAMIOKT <br />FL11470.4 <br />SIM200803 <br />HHCP2 <br />FL17236.7 <br />ESR-3448 <br />HCP2 <br />FL10447.2 <br />ESR-2551 <br />HTA16 <br />FL17680.4 <br />Evaluation Report <br />HETA16 <br />FL11473.5 <br />SIM200802 <br />HTA20.18 <br />FL17680.4 <br />Evaluation Report <br />HETA20 <br />FL11473.5 <br />SIM200802 <br />HTT18 <br />FL17324.2 <br />Evaluation Report <br />HTT16 <br />FL11488.1 <br />ES-0130 <br />HTT45 <br />FL17324.2 <br />Evaluation Report <br />HTT22 <br />FL11498.1 <br />ES-0130 <br />HTW16 <br />FL17244.8 <br />ESR-3455 <br />HTS16 <br />FL10456.22 <br />ESR-2813 <br />HTW20 <br />FL17244.8 <br />ESR-3455 <br />HTS20 <br />FL10456.23 <br />ESR-2613 <br />HTW24 <br />FL17244.8 <br />ESR-3455 <br />HTS24 <br />FL10458.24 <br />ESR-2613 <br />HTW30 <br />FL17244.8 <br />ESR-3455 <br />HTS30 <br />FL10458.26 <br />ESR-2813 <br />HTWM16 <br />FL6223.2 <br />Evaluation Report <br />HTSM16 <br />FL11473.11 <br />SIM200802 <br />HTWM20 <br />FL6223.2 <br />Evaluation Report <br />HTSM20 <br />FLi 1473.11 <br />SIM200802 <br />HUGT2 <br />FL6223.3 <br />Evaluation Report <br />HGT2 <br />FL10456.18 <br />ESR-2613 <br />HUGT3 <br />FL6223.3 <br />Evaluation Repo <br />PRODUCT APPROVAL SPECIFICATION SHEET (2018) March 28, 2018 <br />As required by Florida Statute 553.842 and Florida Administrative Code 98-72, please provide the information and approval numbers on the building components listed below if they will be utilized on the <br />construction project which you are applying for a building permit. We recommend you contact your total product supplier should you not know the product approval number for any of the applicable listed <br />products. <br />CategoryiSubcategory <br />Manufacturer <br />Product Description <br />Approval Number(s) <br />Test Pressures <br />1. EXTERIOR DOORS <br />A. SWINGING <br />ThermaTru <br />Firber-Classic and Smooth -Star (NON -IMPACT) <br />FL20481.1 <br />+g7.0/-67.0 psf <br />ThermaTru <br />Firber-Classic and Smooth -Star (NON -IMPACT) <br />FL20461.6 <br />+67.0/-87.0 psf <br />ThermaTru <br />Firber•Classic and Smooth -Star (NON -IMPACT) <br />FL2pggl,g <br />+87.0/-67.0 psf <br />ThermaTru <br />Firber-Classic and Smooth -Star (NON -IMPACT) <br />FL20461.14 <br />+67.0/-67.0 psf <br />ThermaTru <br />Classic -Craft and Benchmark <br />FL15225,1 <br />+67.0/-67.0 psf <br />ThermaTru <br />Smooth -Star and Benchmark <br />FL15225.5 <br />+87.0/-67.0 psf <br />ThermaTru <br />FiberClassic, Smoothstar, ClassicCraft, Rustic <br />FL7640.1 <br />+67.0/-67.0 psf <br />B. SLIDING <br />MI Windows and Doors <br />Series 420 <br />FL15332.1 - FL15332.5 <br />+40.0/-40.0 psf <br />PGT <br />Series 5570 <br />FL251.10 <br />C. SECTIONAL <br />Clopay Building Products <br />Residential WindCode Doors W5 (8X7) <br />FL15279:37 <br />+30.0/-32.0 psf <br />Clopay Building Products <br />Residential WindCode Doors W5 (16X7} <br />FL15279.53 <br />+30.0/-30.0 psf <br />Clopay Building Products <br />Residential WindCode Doors W6 (8X7) <br />FL15279.85 <br />+38.0/-42.0 psf <br />Clopay Building Products <br />Residential VndCode Doors VJ8 (18X7) <br />FL15279.102 <br />+37.0/-41.0 psf <br />D. METAL LOUVERED DRS <br />Curries Division of AADG, Inc <br />807,707,727,747,and 847 Single &Pairs of Doors <br />FL11537.1 <br />N/A (see inst sht) <br />2. WINDOWS <br />A. SINGLE HUNG <br />MI Windows and Doors <br />Series 185 <br />FL17499.2 <br />+50.0l-55.0 psf <br />PGT <br />Series 5500 <br />FL239.7 <br />B. HORIZONTAL SLIDER <br />MI Windows and Doors <br />Series 188 <br />FL15351.1 <br />+40.0/-50.0 psf <br />C. FIXED <br />MI Windows and Doors <br />Series 185 <br />FL15349.1 <br />+40.0/-00.0 psf <br />PGT <br />Series 5520 <br />FL243:9 <br />D. MULLION <br />MI Windows and Doors <br />Series 5764 <br />FL15353.2 <br />N/A <br />PGT <br />Series 5500 <br />FL261.1 <br />N/A <br />E. OTHER <br />3. PANEL WALL <br />A. SIDING <br />James Hardie Building Prod. <br />Cemplank Lap Siding and HardiePlank Lap Siding <br />FL13192.1 - FL13192.2 <br />N/A <br />B. SOFFITS <br />Alside <br />Solid and Vented Soffit <br />FL15272.1 - FL15272.2 <br />+70.0/-70.0 psf <br />C. OTHER <br />4. ROOFING PRODUCTS <br />A. ASPHALT SHINGLES <br />GAF <br />3 Tab, Dimensional <br />FL10124.1 <br />N/A <br />B. UNDERLAYMENTS <br />Tamko <br />151b Felt Underlayment <br />FL12328.6 <br />N/A <br />C. ROOFING FASTENERS <br />NOT USED <br />D. ROOF VENTILATORS <br />Thompson Arch Metal Comp. <br />Off Ridge Vents <br />FL16918.1 - FL16918.4 <br />N/A <br />Florida Metal Products, Inc <br />Vent RV10 <br />FL21580.3 <br />N/A <br />Lomanco, Inc <br />DA-4 Exahust Vent <br />FL17202.t <br />N/A <br />E. ROOFING TILES <br />Boral Tile <br />Villa 900 <br />FL7849.27 - FL7849.28 <br />N/A <br />Boral Tile <br />Saxony 900 <br />FL7849.16 - FL7849.20 <br />N/A <br />F. METAL ROOF <br />Gulf Coast Supply &Manufacturing, LLC <br />0.032" Aluminum GulfLok 16" wide roof panel <br />FL11651.2 R3 <br />NIA <br />S. SHUTTERS <br />A. STORM PANELS <br />Global Protection Products <br />Galvanized Steel Storm Panels <br />FL15076.1 - FL15076.2 <br />N/A <br />All American Shutters &Glass <br />Galvanized Steel Storm Panels <br />FL17669.1 <br />N/A <br />6. STRUCTURAL <br />COMPONENTS <br />A. WOOD CONNECTORS! <br />USP Structural Conn, <br />see chart <br />ANCHORS <br />Simpson Strong -Tie <br />see chart <br />B. TRUSS PLATES <br />ITW Building Components <br />Alpine Truss Plates <br />FL1999.1 - FL1999.4 <br />N/A <br />MiTek Industries, Inc. <br />Truss Plates <br />FL2197.1 - FL2197.5 <br />N/A <br />C. ENGINEERED LUMBER <br />Weyerhaeuser <br />Rim Board, LVL, PSL, LSL <br />FL8527.1 - FL6527.5 <br />N/A <br />D. MATERIAL <br />Cast -Crete Corp. <br />High Strength Concrete Lintels <br />FL158.1 <br />N/A <br />Commercial Concrete Products, Inc. <br />High Strength Concrete Lintels <br />FL1774 <br />N/A <br />The products listed below did not demonstrate product approval at plan review. I understand that at the time of inspection of these products, the following information must be available to the inspector on the <br />jobsite; 1) copy of the product approval, 2} the performance characteristics which the product was tested and certified to comply with, 3) copy of the applicable manufacturers installation requirements. Further, I <br />understand these products may have to be removed if approval cannot be demonstrated during inspection. <br />APPLICANT SIGNATURE <br />DATE <br />