Laserfiche WebLink
— — — — — — — — — — — — — <br />I I <br />I I <br />_ I I <br />I I <br />I I <br />I I <br />I I <br />I <br />I <br />I I <br />I I <br />I <br />1----------------1 <br />INSULATION REQ. <br />LOCATION <br />R-VALUE / TYPE <br />EXT CONIC WALL <br />R-4.1 HIGH PERM <br />EXT FRAME 2X4 <br />R-11/R-13 KRAFT FACED <br />EXT FRAME 2X6 <br />R-19 KRAFT FACED <br />CONDITIONED CEILING <br />R-30 BLOWN -IN <br />(INSTALL BAFFLES AT EAVE) <br />GARAGE SEPARATION <br />(GARAGE / LIVING) <br />R-11/R-13 KRAFT FACED <br />(2) SHEET METAL <br />SCREWS PER <br />BRACKET <br />(4) HURRICANE <br />BRACKETS <br />3/8" DIAMETER CEMENT II <br />ANCHORS, TYP 3" TO 5" <br />LONG <br />A/C PAD <br />A/C UNIT HOLD DOWN <br />SCALE: N.T.S. <br />10'-0" <br />TANK -LESS W/H <br />=1=1=L1=1= <br />u <br />H C G <br />CORNER OF 00 O <br />HOME <br />GARAGE SIDE c� o <br />STUB -OUT FOR 1'-0" o ' <br />GAS METER O O <br />U <br />N 0 <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />**ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2) 16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />1 SIMPSON HTS20 OR 3 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />1 SIMPSON HTS20 OR 4 16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />164" <br />(1) SIMPSON HTS20 OR (3) 16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />W <br />J <br />m <br />ROOF DIAPHRAGM NAILING SCHEDULE <br />RIDGE LINE <br />+ <br />+ + + + + + + + <br />+ + + + + - + + + + <br />+ <br />+ + + + + + + + o <br />+ + + + + F + + + + <br />t + <br />+ <br />+ + + + + -1- + f + + f. <br />; -I- <br />+ <br />E i- + + -F f- + -+- 1- + <br />a- + -I- + -+- + -+ i- - +- -F + + -+- <br />+ + <br />+ + <br />+ <br />+ + <br />+ - <br />-0" (TYP.) <br />6'-0" <br />+ <br />s'-o° <br />+ 4 <br />+ <br />+ <br />+ -+. <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ {- <br />! <br />T <br />+ <br />+ <br />+ <br />- <br />+ <br />+ + <br />+ + + + + _ + +- <br />+ + + + -1- + + --pp <br />+ .� <br />+ + + _ _ <br />+ + + T + <br />+ <br />+ <br />+ <br />+ + + + + + + + -o <br />+ <br />+ + + + + + + + + + <br />+ + <br />+ <br />+ + <br />+ r <br />c3' <br />—RIDGE LINE <br />3 SECOND GUST EXPOSURE "C" WIND ZONE ( 3 SECOND GUST EXPOSURE "C" WIND ZONE <br />15/32" CDX <br />PLYWOOD OR <br />7/16" OSB <br />^,-� l: + �•�. <br />END WALL OR GABLE TRUSS <br />OU RINU JfIAI'M IVAILJ L O V.V. CUUCJ Ce <br />8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE <br />a <br />0.113 INCH NOMINAL SHANK DIAMETER <br />0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH <br />16 TO 20 RINGS PER INCH <br />0.280 INCH FULL ROUND HEAD DIAMETER <br />0.280 INCH FULL ROUND HEAD DIAMETER <br />2 INCH NAIL LENGTH <br />2 INCH NAIL LENGTH <br />NOTE: <br />FOR 8d RING SHANK NAILS 0.113x 2x 3/8" RING SHANK COIL GUN NAILS MAYBE USED <br />1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. <br />2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. <br />3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING <br />CONSISTS <br />OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Series <br />Thickness <br />Filler Block Thickness <br />3/4" or 7/8" <br />5000s 1.8l1.7 <br />wood panels <br />Two 3/4" wood panels or 2 x _ <br />1-1/8" or two 1!2" <br />6000s 1.8/1.7 <br />wood panels <br />2x - + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x - + 5/8" or 3/4" wood panel <br />1- 1/8" or two 1/2" <br />602.0 <br />wood panels <br />2x - + 5/8" or 3/4" wood panel <br />902.0 <br />2 x - lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />1/8" gap <br />8 <br />FILL CELL <br />W <br />C> STD. 90° <br />CONT. #5 <br />HOOK <br />BAR <br />STD. 900 HOOK i- BOND BEAM <br />CONT. #5 <br />BAR <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />if <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN SEE PLAN FOR REPLYWOOD FLOOR <br />Q'D �C �- .� <br />SHEATHING PER PLAN <br />COLUMN AND <br />CONNECTION ' � � i" �'� � -' �- <br />��'�� TJI TO BE CUT TO ALLOW <br />f FOR BLOCKING/TJI <br />::�:MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />' BLOCKING TO MATCH <br />- Solid block all posts from # OF 2nd FLOOR <br />above to bearing below. STUDS <br />SECTION @ INT. BRIG. WALL <br />N.T.S. <br />k <br />1/8" min. )Small gap 2" min. <br />* 2" max. <br />4" max. <br />- U i <br />Clinch nails <br />when <br />possible f <br />�r n <br />web -flange a connection. g 9 P 9- _..__.....__._.._..__._ <br />1 Support back of web Burin nailing to prevent damage to <br />2) Block solid between joists for full length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4) Place joists together and nail from each side with 2 rows of 10d nails 2x4/Plywood/OSB web stiffener 2" min. <br />required when indicated or 4" max. <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite -Hangers with side nailing. — — <br />OFTHE JOIST ASA REQUIRED LEAVING Y" GAP @TOP sides by 6". - Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />DOUBLE JOIST CONNECTION - Birdsmouthcuts. N.T.S. <br />-- - -- ----- ----- - Under 2nd floor column w/ loads <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />* Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />wall or beam below.* <br />consideration. Check <br />local building <br />code for appropriate <br />]Lor=20 <br />1/16" <br />details in <br />One 10d box <br />areas=20 of high <br />sinker <br />lateral load. <br />nail each side <br />at bearing. <br />Squash block <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />NO HOLES (EXCEPT <br />KNOCKOUTS) ALLOWED <br />IN BEARING ZONES —� <br />DO NOT cut, notch <br />or drill flanges <br />Boise Joist Blocking <br />Use 3" (10d) nails at 6" o.c. <br />Load bearing walls <br />Web Stiffener Fastener Schedule <br />r Joist Bearing Location <br />End Intermediate <br />Series _ 9 <br />11/2 <br />2 ga <br />2-8d <br />BCI 5000s <br />_._.._ ;. _- <br />1 114/8 <br />3-8d <br />2- <br />2-8d <br />5- 8d <br />9-1/2" <br />2-8d _ <br />2-8d <br />BC16000s®111-7/8" <br />2-8d <br />BCI 6500s® <br />14" <br />2-8d i <br />__3-8d <br />5 8d <br />- <br />16" <br />2-8d <br />- 6-8d <br />BCI 60s® <br />11-7/8" <br />14 <br />2-8d <br />2-8d <br />I 3-8d <br />1 5-8 d _- <br />16 <br />2-8d1 <br />6 8d <br />11_-7/8" <br />3-16d <br />3-16d ___ i <br />BCI 90s® <br />�. _ 14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : for vertical load transfer Plumbing <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over _ <br />blocking and wall or beam below.* — <br />It Joist <br />�When joists meet over wall, provide <br />13/4" minimum bearing for each. I -Joist can be offset <br />Provide adequate bearing <br />for each lapped joist. Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />nails require additional consideration. <br />SECTION @ INT. BRIG. WALL <br />— <br />N.T.S. <br />MINIMUM SPACING = 2x GREATEST <br />D DIMENSION OF LARGEST HOLE <br />(see table below) (KNOCKOUT EXEMPTS) D <br />(see table below) <br />zo <br />6„ A 1Y" ROUND HOLE MAY 6„ 6„ DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN1Y' <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Y" <br />" <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1Y" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE 1Y" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />up to 3 to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S <br />Backer block (12" wide min.) <br />Nail with 10-10d nails. <br />Install tight to top flange. <br />Joist hanger <br />1 <br />l <br />Filler block. <br />Nail with <br />,7 I 10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />F_ kuBacker <br />- - <br />/4"-2" gap- <br />- <br />Block - <br />'Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4%2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />1- <br />+ 0.6 X Joist <br />depth <br />\ a <br />I -JOISTS BUCKETS <br />N.T.S. <br />SIMPSON MGT <br />w/(22)10d <br />NAILS TYP. <br />GIRDER TRUSS <br />2 x TOP <br />• PLATE <br />5/8"o <br />THRU <br />BOLT <br />2"x BUILT <br />UP COLUMN <br />SIMPSON MGT <br />w/ (22) 10d <br />NAILS TYP. <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON <br />LUS/HUS/HUC INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON HETA20 / <br />HETAL20 INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />SLEEVE THRU STEM-/ ° <br />a. <br />SEE PLAN FOR---'°• a .. • <br />FOUNDATION INFO < a ° <br />STEM FOUNDATION <br />r-GRADE <br />WV %,nmorz 4 rvu <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON HETA20 / HETAL20 <br />INSTALLATION AT MID SPAN <br />SIMPSON I <br />w/ (18) 10d <br />NAILS <br />UPLIFT =1 <br />TYPICAL SIMPSON <br />H10A INSTALLATION <br />DOTE: <br />)PLIFT VALUE <br />3 BASED ON <br />>. P. F. <br />LOCATION OF <br />SECOND H10A <br />(WHEN <br />REQUIRED) <br />TYPICAL SIMPSON <br />MTS/HTS INSTALLATION <br />TOP (2) #5's x 4' 0" <br />CENETERED @ PIPE <br />PENETRATION <br />d" .. ° <br />d <br />:III I I=1 5d\1N <br />1=1 <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />a <br />i-- SEE FND. PLN. <br />SIZE & REINF. <br />12" BELOW PIPE VERTICAL THRU FND. <br />GRADE <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENETERED @ PIPE PLUMBING LINE <br />PENETRATION <br />° d d <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENETERED @ PIPE <br />PENETRATION PLUMBING LINE <br />° °. d <br />d d°. d dC G <br />d <br />d <br />I —I � I— <br />HV <br />SEE FND. PLN. <br />SIZE & REINF. <br />!0®Illltlll///® <br />VV. O_JRV <br />•. A <br />CID o• <br />CC <br />® :UJC e <br />'® <br />t <br />®• Z. <br />12 <br />8t t tlq®`�'S�� <br />Z 0 0w <br />F w 0 w� N Q N Z <br />O cG z = j z w 0 <br />wOp_ 1- O7g <br />2U�n o�F-z� W <br />-,0 0 rz°ate ~ <br />az U <br />=owl o�¢aow <br />I�— <br />H <br />Q <br />LLc° wCwo=pw rr <br />P:zaz zID 0 <br />Uood wz za z�o <br />F- w - W <br />2 v K w C Q <br />w <br />Q3 a� <br />m � <br />V 00 r' <br />l0 N <br />m N m <br />o m Ln 00 <br />0 <br />Z D— Mn w w <br />Mtiti W Ln ar o w w <br />Z w OJ o °N° v=i <br />o " r` q '�' <br />Y <br />-1 <br />Z a r'i o <br />LJJ w U 0-4 <br />X a z < S <br />F V) Q a- = <br />ne <br />0 N. I a <br />> <br />11 <br />D <br />ON <br />Z <br />O � <br />N <br />'-' 4_J O <br />(n M D <br />M <br />Q <br />Q U-) <br />a Lnz 'L CC' <br />2: Ln <br />Q U_ <br />M <br />0Y V ,-t <br />fu <br />WCD <br />WH <br />CD <br />0 <br />ui <br />0 <br />Q <br />UJ <br />0� <br />0 <br />n <br />U z <br />a <br />SCALE : AS NOTED <br />DATE : 05-07-2018 <br />SHEET NO. <br />SN 1 <br />