My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
35981 Saddle Palm Way
Zephyrhills
>
Building Department
>
Building Plans
>
35981 Saddle Palm Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 1:55:09 PM
Creation date
2/19/2025 8:44:19 AM
Metadata
Fields
Template:
Building Plans
Street #
35981
Location
Saddle Palm Way
Contractor
Lennar Homes LLC
Building Plans - Permit #
20424
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- - - - - - - - - - - - - <br />I � <br />WEATHER <br />RESISITIVE <br />BARRIER <br />TAPE <br />(ASSEMBLED WINDOW) <br />I <br />HEAD FLASHING TIE-IN INSTRUXTIONS: <br />1. Cut, fold up & temporarily secure weather resistive <br />THESE DETAILS ARE GENERIC AND barrier above header to allow for flashing <br />installation <br />FOLD UP WEATHER <br />RESISTIVE BARRIER & <br />TEMPORARILY SECURE <br />EXTERIOR <br />SHEATHING <br />WEATHER <br />RESISITIVE <br />BARRIER <br />ED FLASHING <br />WOOD FRAME CONSTR. <br />SELF -ADHERED FLASHING <br />BY LAPPING DOWN -� <br />OVER RIM JOIST AND UP <br />WALL BY 6 IN. <br />SEAL TOPS OF JOISTS <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />WEATHER RESISTIVE <br />BARRIER <br />DOOR ROUGH OPENING <br />3/4"-1" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHERPROOF CAULKING <br />SELF -ADHERED FLASHING <br />SUBFLOOR <br />RIM JOIST <br />WINDOW UNIT <br />C11 r%mr- <br />icm) <br />RED FLASHING <br />gPER <br />NTH <br />MEANT TO SHOW GENERAL FLASHING 2. Self -adhered flashing plus head flashing under 1 1 <br />AND WATERPROOFING METHODS TO weather resistive barrier <br />BE USED. 3. Fold weather resistive barrier back over head 2 2 .4 = Q <br />flashing and seal with tape <br />SELF -ADHERED FLASHING Scale: NITSSELF-ADHEREDFLASHING <br />FLANGED WINDOW WPO 1 EXTERIOR SELF -ADHERED FLASHING \/\/P02 WP43 <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER OR DOOR WITH DECK - SECTION A V V CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER <br />EXTERIOR SHEATHING MECHANICALLY FASTEN IF RUBBERIZED RUBBERIZED ASPHALT <br />3/4"-V BEAD OF CONSTR. NEEDED IN CORNERS ADHESIVE <br />EXTERIOR SHEATHING INSTALL SELF -ADHERED THROUGH SELF -ADHERED ASPHALT ADHESIVE <br />ADHESIVE TO BE APPLIED UNDER FLASHING JAMB & HEAD THRESHOLD OF DOOR AND RETURN FLASHING, SEE FLASHING SELF -ADHERED FLASHING <br />:....:. <br />UP JAMB 6". USE LIQUID NAIL BRAND FLANGED WINDOW <br />„• OR EQUAL WEATHER PROOF CAULKING (SEE DETAIL WP01) <br />REFER TO TECHNICAL . ... <br />LETTER ON CHEMICAL """"' SCORED <br />COMPATIBILITY '' ' RELEASE PAPER <br />SELF -ADHERED FLASHING (BEFORE FOLDING, SCORE <br />SELF -ADHERED FLASHING, "' <br />EXTEND A MINIMUM 6" RELEASE PAPER TO EXPOSE <br />VERTICALLY FROM ADHESIVE AS SHOWN) <br />Z.... .. .......... .. <br />BOTTOM OF <br />.... O THRESHOLD <br />SECTION -A (SEE DETAIL WP02) <br />DO NOT FLASH OVER <br />BOTTOM NAILING <br />FLANGE <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />r LF1J�IIIVu <br />SELF -ADHERED FLASHING <br />DECK JOIST <br />NOT USED <br />NAILING FLANGE <br />1- L/YJ 1 111 V la <br />SELF -ADHERED FLASHING <br />WP10 <br />SELF -ADHERED FLASHING <br />SEAL TOPS OF JOISTS <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />SHEATHING <br />SELF -ADHERED FLASHING <br />OUTSIDE CORNER <br />NOT USED <br />SELF -ADHERED FLASHING <br />PATCH <br />• <br />l�l3fl <br />SELF -ADHERED FLASHING <br />INSIDE CORNER <br />Ground <br />FOUNDATION WEEP SCREED <br />NOT USED <br />Water Resistant Barrier <br />Lath <br />Sheathing <br />Stucco <br />WP12 <br />FLASHING REQUIREMENTS <br />R609.1 Flashing, Sealants and Weatherstripping. Flashing and sealants for exterior windows shall comply with Section R703.8 <br />R703.2 Weather -resistant sheathing paper. One layer of No.15 asphalt felt, free from holes and breaks, complying with ASTM D 226 for Type 1 felt or <br />other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 inches (51 mm). Where joints occur, felt shall be lapped not less than 6 inches (152 <br />mm). The felt or other approved material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner <br />to meet the requirements of the exterior wall envelope as described in Section R703.4 <br />Exception: Omission of the water -resistive barrier is permitted in the following situations: <br />1. In detached accessory buildings. <br />2. Under exterior wall finish materials as permitted in Table R703.4 <br />3. Under Paperbacked stucco lath when the paper backing is an approved water -resistive barrier. <br />R703.4 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into thewall cavity or <br />penetration of water to the building structural framing components. Self -adhered membranes used as flashing shall comply with AAMA 711. The <br />flashing shall extend to the surface of the exterior wall finish. Approved corrosion -resistant flashings shall be installed at all of the following locations: <br />1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of he exterior wall finish or to the <br />water -resistive barrier for subsequent drainage. Flashing at exterior window and door openings shall be installed in accordance with one or more of the <br />following or other approved method: <br />1.1 The fenestration manufacturer's written flashing instructions. <br />1.2 The flashing manufacturer's written installation instructions. <br />1.3 In accordance with FMA/AAMA 100, FMA/AAMA 200, or FMA/WDMA 250. <br />1.4 In accordance with the flashing method of a registered design professional. <br />2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under stucco copings. <br />3. Under and at the ends of masonry, wood or metal copings and sills. <br />4. Continuously above all projecting wood trim. <br />5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />6. At wall and roof intersections. <br />7. At built-in gutters. <br />R703.6.2.1 Weep Screeds <br />A Minimum 0.019-inch (No. 26 Galy. sheet gage), corrosion -resistant weep screed or plastic weep screed, with a minimum vertical attachment flange of <br />3 1/2" shall be provided at or below the foundation plate line on exterior stud walls in accordance with ASTM C 926. <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS <br />TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND <br />ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2.1 <br />Detail Instructions <br />Refer to the number marked as Oin each detail that corresponds to the numbered items in the list of <br />instructions below: <br />1. Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water shedding laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, embedded in the adhesive layer) - <br />for ease of installation and to minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and adhere to substrate using a square <br />piece of flashing material (6" x 6" Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to fit tight to corner <br />8. Mechanically fasten as necessary <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />Cement <br />Plaster <br />over block <br />1 st floor <br />- 7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />- Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />-7/16" O.S.B. <br />sheathing <br />Metal <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain <br />Bottom of <br />Weep Screed <br />1 1/2" to 2" <br />Above Roof <br />Sheathing <br />Note: <br />The building paper and metal lath must be <br />installed over the top of the weep screed. <br />WEEP SCREED DETAIL <br />SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />_Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside corner will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />0 <br />0 <br />Z fV <br />O au N <br />ZQ <br />F-1 a-+ o <br />>(AMo <br />M <br />t] �_ L0 <br />Vi L N <br />< L- U- <br />CL �M <br />oC U OC) m <br />a c0 <br />Q <br />z� �v <br />WJ <br />O� <br />d" <br />Z <br />U. <br />0 <br />0 <br />CL <br />F- <br />SCALE : <br />AS NOTED <br />DATE : <br />05-07-2018 <br />SHEET NO. <br />W P <br />
The URL can be used to link to this page
Your browser does not support the video tag.