My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
35982 Saddle Palm Way
Zephyrhills
>
Building Department
>
Building Plans
>
35982 Saddle Palm Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 2:15:06 PM
Creation date
2/19/2025 8:44:36 AM
Metadata
Fields
Template:
Building Plans
Street #
35982
Location
Saddle Palm Way
Contractor
Lennar Homes LLC
Building Plans - Permit #
20605
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />NEMA1 <br />200 AMP <br />MAIN <br />0 <br />200 amp <br />150 amp <br />copper to lights & outlets <br />copper to 20 amp ckts <br />-2 copper to WH <br />-3 copper to Dryer <br />or 4/0 SER Alu <br />DisconneE#4GROUNDING <br />POWER CO. FEED <br />INTERSYSTEM are Cu Ground AC PAD <br />BONDING WIRE <br />TERMINATION PER WITH CODE APPROVED <br />NEC 14, 250.94 J CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />---------------------------------------------- <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station cc alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FEPP <br />DUPLEX OUTLET ABOVE COUNTER <br />w P <br />WEATHERPROOF DUPLEX OUTLET <br />LG.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />I� <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />Q <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />�2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />l�l <br />THERMOSTAT <br />ELECTRIC METER <br />owl <br />ELECTRIC ELECTRIC PANEL <br />_WEI <br />DISCONNECT SWITCH <br />(� <br />SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />ENTRY LIGHT — <br />AS PER SPECS <br />WP DISC. E)PAD <br />(Ili r-IIr-tl <br />VERIFY METER <br />LOCATION WITH <br />BUILDER <br />MAIN FLOOR ELECTRICAL PLAN - <br />SCALE: %4'=1' <br />Z M <br />_ o <br />Zco <br />Z <br />o_ <br />U) Z <br />nL/)Ur <br />'' <br />co) <br />�W W <br />�V — <br />O W <br />� <br />F- <br />E- <br />(A <br />Ln <br />o <br />C) <br />o ti <br />Fn N <br />W <br />p —E <br />8 <br />N M <br />M <br />`�N <br />O`oo <br />C) N <br />U_00 <br />o <br />Q rn <br />n o <br />0Qv <br />rn Q d <br />Al I ®® <br />NC-B-D,C <br />N �D <br />N <br />Op <br />p MN a.,� W <br />N � <br />LUqj N <br />n <br />Z > III: 5 a <br />L <br />b <br />O 2 4:: <br />O <br />vi m oCNQ <br />z <br />LLZ�� <br />W N d M :E q� <br />N <br />o <br />El 171 <br />WWW.FDSENG.COM <br />00 <br />0 <br />N <br />0 <br />ch <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />aZ <br />0 <br />�F <br />Z <br />Wa�� <br />Q <br />Uzoo <br />= O W <br />Z <br />W <br />Q <br />a��ao <br />OLU <br />�LLN <br />o <br />_ <br />Zo <br />Ci <br />} <br />O <br />U <br />g <br />W <br />\../ <br />fu <br />W <br />o <br />CU <br />> <br />T� <br />�W <br />in <br />M <br />M <br />-� <br />000 <br />F- 0 <br />0 <br />J <br />LL_ <br />< o � <br />r <br />z <br />52md <br />U CL <br />r%4 <br />Q <br />O <br />Z<Za <br />h <br />Wc'a� <br />Q <br />Ln <br />o o <br />Z <br />N <br />2o�2 <br />Z <br />714 <br />L <br />� a � � <br />LL <br />W <br />J <br />/ <br />rl <br />t Ll <br />Lij <br />. <br />to o u� a <br />�~o <br />oll <br />Q <br />Z <br />tZ <br />Z <br />azo <br />0 <br />Gn <br />W <br />Z <br />Q <br />= <br />J to <br />¢ X <br />SCALE : AS NOTED <br />DATE : 3/7/2018 <br />TECH: JMUROSKI <br />VERSION NO. <br />3.0 <br />SHEET NO. <br />4.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.