My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
35989 Saddle Palm Way
Zephyrhills
>
Building Department
>
Building Plans
>
35989 Saddle Palm Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 2:25:43 PM
Creation date
2/19/2025 8:44:59 AM
Metadata
Fields
Template:
Building Plans
Street #
35989
Location
Saddle Palm Way
Contractor
Lennar Homes LLC
Building Plans - Permit #
20428
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL INSTALLATION NOTES <br />1. PROVIDE FULL MORTAR BED AND HEAD JOINTS. 8. CAST -IN -PLACE CONCRETE MAY BE PROVIDED IN <br />COMPOSITE LINTEL IN LIEU OF CONCRETE MASONRY <br />2. SHORE FILLED LINTELS AS REQUIRED. UNITS, <br />3. INSTALLATION OF LINTEL MUST COMPLY WITH THE 9. SAFE LOAD RATING BASED ON RATIONAL DESIGN <br />ARCHITECTURAL AND/OR STRUCTURAL DOCUMENTS. ANALYSIS PER ACI 318 AND ACI 530 <br />4. U-LINTELS ARE MANUFACTURED WITH 5 1 /2" LONG 10. THE EXTERIOR SURFACE OF LINTELS INSTALLED IN <br />NOTCHES AT THE ENDS TO ACCOMMODATE VERTICAL EXTERIOR CONCRETE MASONRY WALLS SHALL HAVE A <br />CELL REINFORCING AND GROUTING. COATING OF STUCCO APPLIED IN ACCORDANCE WITH <br />ASTM C-296 OR OTHER APPROVED COATING. <br />5. REFERENCE THE CAST-CRETE LOAD DEFLECTION <br />GRAPH BROCHURE FOR LINTEL DEFLECTION 11. LINTELS LOADED SIMULTANEOUSLY WITH VERTICAL <br />INFORMATION. (GRAVITY OR UPLIFT) AND HORIZONTAL (LATERAL) LOADS <br />SHOULD BE CHECKED FOR THE COMBINED LOADING <br />6. BOTTOM FIELD ADDED REBAR TO BE LOCATED AT WITH THE FOLLOWING EQUATION: <br />THE BOTTOM OF THE LINTEL CAVITY. <br />APPLIED VERTICAL LOAD APPLIED HORIZONTAL LOAD <br />+ <br />7. 7/32" DIAMETER WIRE STIRRUPS ARE WELDED TO SAFE VERTICAL LOAD SAFE HORIZONTAL LOAD <br />THE BOTTOM STEEL FOR MECHANICAL ANCHORAGE. <br />12. ADDITIONAL LATERAL LOAD CAPACITY CAN BE <br />OBTAINED BY THE DESIGNER BY PROVIDING ADDITIONAL <br />REINFORCED CONCRETE MASONRY ABOVE THE LINTEL. <br />SEE DETAIL AT RIGHT:oil <br />GENERAL CONCRETE LINTEL SCHEDULE <br />• • <br />• <br />•• <br />8F8-1B/1T 8F8-OB/1T 8RF6-OB/1T <br />• • <br />O SF12-1B/1T O O • • • • <br />8RF14-1B/1T 8RF14-OB/IT 8F16-OB/1T 8F16-1B/1T <br />• • • • • • <br />O O O O 8F20-OB/1T BF20-1B/1T 8F20-1B/8T <br />O O O <br />8F44-1B/1T BF40-OB/1T 8RF40-OB/1T 8F32-1B/1T BF32-OB/1T 8RF30-1B/1T 8F28-0B/1T 8F28-1B/1T BF24-OB/IT BF <br />(MIN.) <br />II II <br />I- ' U., <br />I II <br />Li II <br />II <br />I I (MIN.) <br />�------� I <br />G(MIN.) I ------I I <br />I I II <br />I I II <br />I I II <br />(MIN.) <br />I I II <br />� — I I O(MIN.)T, ;f <br />II IIlu <br />II IL — <br />II I C <br />—J L—� <br />L---- <br />E (MIN.) OELI <br />(MINJ O(MIN.) <br />O <br />— — — — — — — — — — — — — — — _ — — — — — — — — — -� - — — — — — — — — - <br />- — — — — — — — — — — — — — — — — — — — — — — — — — �Ir — — — — — — — — — — — — — — — — — — — <br />I �� <br />II II j� II I I 11 <br />� I <br />II II II I <br />II II II <br />II I II I <br />L� I <br />IF-J ] C-1 F—J —I� I I OIMIN.) <br />(MIN.) <br />I� �I II II I I <br />I II <br />OIMIN) J I I I I <br />II f �i II II I I <br />II I I <br />II <br />11 I I <br />--� I �------- IL-------J I <br />c=1=-------------- I I ------- I <br />II I I I II II II II <br />JI II II 11 <br />I I I I I (MIN.) <br />II II II 11 <br />II II it 11 <br />II II II 11 <br />(MIN.) I I I I I I <br />II II II 11 <br />II II II 11 <br />II II II 11 <br />�I II II 11 <br />� L: I I I I 1 1 <br />II II II II 11 <br />II II II II 11 <br />II II II II 11 <br />(MIN.) (MIN.) (MIN.) <br />LINTEL PLAN - A <br />SCALE: 1/4" - I'-0" <br />Li 2 <br />i <br />DAVIS BEWS <br />DESIGN GROVP <br />150 STATE S7RFET EAST <br />OLD6MAR, A.ARIDA 39677 <br />813.925.1,300 TEL <br />813. 925. 1800 FAX <br />W W W.DAVISBEWS�COM <br />TAMPA • DElVVER. <br />� EST. 199� �-^� <br />VORTEX ENGINEERING, I.I.C. <br />607 S. ALEXANDER ST., SUITE 103 <br />PLANT CITY, FLORIDA 33563 <br />813.704.4842 <br />COA 28035 <br />PAUL D. KIDWELL, P.E. #52683 <br />ANDREW J. MEISHEID, P.E. #83217 <br />I HEREBY CERTIFY THAT I HAVE REVIEWED THE <br />ATTACHED DESIGN, AND FIND IT TO BE IN COMPLIANCE <br />WITH SECTION R301 OF THE FLORIDA BUILDING CODE, <br />RESIDENTIAL6TH EDITION (2017). <br />THE ENGINEER HAS NOT REVIEWED THE <br />PRE-ENGINEERED TRUSS MANUF. LAYOUT TO <br />DETERMINE ANY LOAD BEARING CONDITIONS AND <br />RESERVES THE RIGHT TO MAKE ANY CHANGES AFTER <br />TRUSS LOAD INFORMATION IS SUPPLIED TO THE <br />ENGINEER. <br />SEALED FOR STRUCTURE ONLY <br />0 <br />O <br />Z (V <br />O aJ � <br />M <br />Q � -v � <br />Q � LL � <br />z� �� <br />wo <br />w <br />oZ <br />�o <br />Za <br />Z <br />w Q � � <br />vZOp <br />ZWww <br />►►►�yyy � z z <br />a��o <br />o� <br />Zo <br />a <br />�w <br />Z � a� <br />O � z �oo <br />z � W vvY <br />J � m <br />J a�a <br />O C ] J <br />/� U� Q Q <br />Q I..1 J � O a Z W �' <br />N 17 �a�o <br />Z N � Z o�o� <br />Z N I� Zo <br />J � N J �a�a <br />�Qgo <br />w w Z <br />Zg <br />z z �O� <br />00 Z Z w � <br />m a a a <br />SCALE : AS NOTED <br />DATE : 7/17/2018 <br />VERSION N0. <br />SHEET N0. <br />