Laserfiche WebLink
— — — — — — <br />I <br />- I <br />I <br />I <br />I <br />I <br />I <br />— — — — — — — <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />L--------------- <br />I <br />I <br />I <br />_I <br />2x8 P.T. BUCK -CONNECT TO BLOCK <br />W/ 1/4" x 3 1/4" TAPCON ( 1 1/4" MIN. <br />EMBEDMENT INTO BILK.) <br />1 X 4 FURRING <br />BLOCK HEADER <br />1/2" DRYWALL <br />8d NAILS AT 8" O.C. AT BUCK <br />2 x 8 45" DIAGONAL (4) 10d NAILS INTO \ — <br />BRACE(S) 2 x 8 BRACE/ BLKG. <br />7/16" OSB X\\ <br />BUILT UP PLWD. BUCK ARCH PANEL CUT HOLE IN O.S.B. FOR <br />SCRIBE (NOTCH) POLY -CELL IN THIS AREA <br />BACKSIDE TO FIT ARCH (4)10d NAILS INTO 2 x 8 <br />CONNECT W/ 8d NAILS BRACE/ BLKG. <br />INSTALL WDW. SCREW ANCHO\_2 x 4 SOLID BLKG. (FULL WIDTH OF WALL) BTWN. OSB <br />INTO ARCH BLKG. PER ARCH FACES W (4) 10d NAILS THRU OSB INTO 2 x 8 <br />INSTALLATION DETAILS A -A PROVIDE TAPCON PER WDW. INSTALLATION DETAILS OR THRU --\\ <br />1-1/2" THK. OR MORE BUCK WITHIN 6" MIN. OF START OF ARCH <br />ARCH DETAIL J <br />SCALE: N.T.S. SS <br />DOOR JAMB (REFER 1X4 1/2" DRYWALL <br />DOOR JAMB (REFER <br />1 X 4 1/2" DRYWALL <br />DOOR JAMB (REFER <br />TO SHT. SDW2-K1 <br />1 X 4 1/2" DRYWALL <br />TO SHT. SDW2-K1 <br />P.T. <br />TO SHT. SDW2-Ki <br />FOR CONN. DETAILS <br />FOR CONN. DETAILS <br />FOR CONN. DETAILS <br />1 X 4 <br />1 X 4 <br />3-1/4" LONG X 3/16"� <br />1 X 4 <br />FURRING <br />3/16" 0 X 3" LONG <br />TAPCONS <br />FURRING <br />3/16"0 X 3-1/2" LONG <br />FURRING <br />TAPCON. INTO <br />STAGGERED @ 16"1X8 <br />TAPCONS STAGGERED <br />2X8 <br />BLOCK@ SPACING „ <br />1 <br />DETAIL <br />O.C. 2-ROWS INTO <br />P.T. <br />STAGGERED @ 16" O.C. <br />2-ROWS INTO <br />iX8 <br />PER MANUFACTURE <br />MASONRY THROUGH 1-1/2" DETAIL <br />MASONRY THROUGH <br />3�1 DETAIL <br />lx4 P.T. & lx8 P.T. <br />1x8 P.T. & 2x8 P.T. <br />3/16" x 3 -1/2" <br />TAPCON @ 16" <br />O.C. & 4" FROM <br />1X4 P.T. <br />3/16" x 3 -1/2" <br />DOOR JAMB (REFER <br />1 X 4 1/2" DRYWALL <br />DOOR JAMB (REFER <br />EACH END W/ MIN <br />DOOR JAMB (REFER <br />TAPCON <br />TO SHT. SDW2-K1 FOR <br />TO SHT. SDW2-Kl <br />2" EDGE DIST. <br />TO SHT. SDW2-K1 <br />CONN. DETAILS <br />FOR CONN. DETAILS <br />FOR CONN. DETAILS <br />10d @ 12" O.C. <br />1 X 4 <br />FURRING <br />2X8 P.T. WITH 3/16"0 X 3" <br />2x P.T. AS REQ'D <br />2X8 P T <br />LONG TAPCONS <br />STAGGERED @ 16" O.C. <br />2X8 <br />2x DETAIL <br />2 1/4" <br />DETAIL <br />2-ROWS INTO MASONRY <br />3-1/4" DETAIL <br />BUILDOUT @ OVER SIZE DOOR -WINDOW ROUGH OPENINGS <br />SCALE: N.T.S. <br />BLOCK HEADER <br />1 X 4 FURRING <br />8d NAILS @ 8" O.C. AT BUCK <br />PROVIDE 2 x 8 DIAG. BRACE BT <br />VERT. BRACES WHEN HGT. OF <br />BRACE EXCEEDS 24" <br />2 x 8 VERT. BRACE(S) <br />BUILT UP PLWD. BUCK - — <br />SCRIBE (NOTCH) BACKSIDE <br />TO FIT ARCH CONNECT W/ <br />8d NAILS <br />INSTALL WDW, SCREW--' <br />ANCHOR INTO ARCH BLKG. <br />PER INSTALLATION DETAILS <br />1 /4" MAX 2'-0- <br />SOLID BLKG. AT TOP BTWN. <br />ARCH BLKG. & BUCK <br />2 x 8 BUCK - CONNECT TO BLOCK <br />WITH 1/4" x 31/4" TAPCON (1 1/4"MIN. <br />�1/4" MAX EMBEDMENT INTO .) 2-0" <br />SOLID BLKG. AT TOP BTWN. ARCH <br />BLKG. & BUCK <br />2 x 8 VERT. W/ (2)10d <br />NAILS AT EA. END <br />LEAVE A CUT OUT IN O.S.B. ON T <br />INSIDE TO ALLOW FOR INSULATION <br />TO BE INSTALLED <br />7/16" OSB ARCH PANEL <br />2 x 4 SOLID BLKG. (FULL WIDTH OF WALLS) <br />BTWN. OSB ARCH FACES W/ (4)1Od NAILS EQUAL <br />THRU OSB INTO 2 x 8 <br />B-B ARCH DETAIL K <br />SCALE: N.T.S. SS <br />GLASS BLOCK INSTALLATION NOTES <br />A) COVER SILL AREA WITH A HEAVY COAT OF ASPHALT EMULSION. ALLOW EMULSION TO DRY <br />AT LEAST 2 HOURS BEFORE PLACING MORTAR. <br />B) ADHERE EXPANSION STRIPS TO JAMBS AND HEAD. MAKE CERTAIN EXPANSION STRIP <br />EXTENDS TO SILL. <br />C) SET A FULL MORTAR BED JOINT, APPLIED TO SILL. <br />D) SET LOWER COURSE OF BLOCK. MAINTAIN A UNIFORM JOINT WIDTH OF 3/8" PLUS OR MINUS <br />1/8". ALL MORTAR JOINTS MUST BE FULL AND NOT FURROWED. ALL MORTAR SHALL BE <br />TYPE "S" OR "N". STEEL TOOLS MUST NOT BE USED TO TAP BLOCKS INTO POSITION. (PLACE <br />A RUBBER CRUTCH TIP ON END OF TROWEL TO TAP BLOCK INTO POSITION.) DO NOT <br />REALIGN, TAP, OR OTHERWISE MOVE BLOCK AFTER INITIAL PLACEMENT. FOR SOLID GLASS <br />BLOCK IT MAY BE NECESSARY TO USE WEDGES IN THE MORTAR JOINTS OF THE LOWER <br />COURSES TO PREVENT THE MORTAR FROM BEING "SQUEEZED" OUT. <br />E) INSTALL PANEL REINFORCING IN EVERY OTHER MORTAR BED HORIZONTALLY AND IN JOINTS <br />IMMEDIATELY ABOVE AND BELOW ALL OPENINGS WITHIN PANELS. (THE SAME SPACING <br />SHALL APPLY TO PANEL ANCHORS WHEN USED AT JAMBS AND HEADS IN LIEU OF CHANNEL <br />OR CHASE SURROUNDS.) RUN REINFORCING CONTINUOUSLY FROM END TO END OF PANELS. <br />LAP REINFORCING NOT LESS THAN 6 INCHES WHENEVER IT IS NECESSARY TO USE MORE <br />THAN ONE LENGTH. DO NOT BRIDGE EXPANSION JOINTS WITH REINFORCING. INSTALL <br />REINFORCING AS FOLLOWS: <br />* PLACE LOWER HALF OF MORTAR IN BED JOINT. DO NOT FURROW. <br />* PRESS PANEL REINFORCING INTO PLACE. <br />* COVER PANEL REINFORCING WITH UPPER HALF OF MORTAR BED AND TROWEL <br />SMOOTH. DO NO FURROW. <br />F) PLACE FULL MORTAR BED FOR JOINTS NOT REQUIRING PANEL REINFORCING - DO NOT <br />FURROW. MAINTAIN UNIFORM JOINT WIDTH. <br />G) SET SUCCEEDING COURSE OF BLOCKS. SPACE AT HEAD OF PANEL AND JAMBS MUST <br />REMAIN FREE OF MORTAR. <br />H) STRIKE JOINTS SMOOTH WHILE MORTAR IS STILL PLASTIC AND BEFORE FINAL SET. AT THIS <br />TIME RAKE OUT ALL SPACES REQUIRING SEALANT TO A DEPTH EQUAL TO THE WIDTH OF THE <br />SPACES. REMOVE SURPLUS MORTAR FROM FACES OF GLASS BLOCKS AND WIPE DRY. <br />TOOL JOINTS SMOOTH AND CONCAVE, BEFORE MORTAR TAKES FINAL SET. (REMOVE <br />WEDGES FROM LOWER COURSES OF SOLID BLOCKS AND POINT THE VOIDS WITH MORTAR.) <br />1) AFTER FINAL MORTAR SET (APPROX. 24 HOURS), INSTALL PACKING TIGHTLY BETWEEN <br />GLASS BLOCK PANEL AND JAMB AND HEAD CONSTRUCTION. LEAVE SPACE FOR SEALING. <br />J) APPLY SEALANT EVENLY TO THE FULL DEPTH OF RECESSES IN ACCORDANCE WITH THE <br />MANUFACTURER'S APPLICATION MANUAL AND INSTRUCTIONS. <br />K) A MAXIMUM OF 60 SQUARE FEET OF GLASS BLOCK MAY BE INSTALLED IN ANY OPENING. <br />FOR WIND SPEEDS UP TO 110 MPH*, PER PITTSBURG CORNING RECOMMENDATIONS FOR <br />INSTALLATION OF GLASS BLOCK. <br />SECTION <br />A -A <br />8" <br />1/4" x 31/4" TAPCONS <br />LEAVE A CUT OUT IN O.S.B. ON THE <br />INSIDE TO ALLOW FOR INSULATION <br />TO BE INSTALLED <br />2 x 8 45 DrAGONAL BRACE AT EA. <br />FACE OF ARCH W/ (3) 10d NAILS <br />AT EA. END <br />PROVIDE TAPCON WITHIN <br />4" MIN. OF BRACE <br />START OF ARC <br />4' MAX. RAD. <br />SECTION <br />B-B <br />8" <br />EQUAL <br />PROVIDE 2x <br />PROVIDE (2) MIN. CONT. W/ (3) <br />TAPCON AT EA. SIDE 12d NAILS <br />BUCK - (1) WITHIN 4" <br />MIN. OF START OF <br />ARCH <br />START OF ARC <br />4' MAX. RAD. <br />EXPANSION STRIP <br />N.T.S. <br />2X6 SYP #2 CONT. (MATCH TRUSS DEPTH <br />IF TRUSSES USED) W/ (3) #6 X 4Y2WOOD <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY <br />WALL USE (3)1/4" X 31/2" TAPCONS AT 16" <br />O.C. <br />JACK TRUSS PROVIDED BY <br />TRUSS COMPANY OR <br />2x6 #2 SYP @ 24" O.C. <br />ROOF SHEATHING ATTACHED <br />PER NAILING SCHEDULE <br />(5)12d NAILS <br />2X6 TO 2X4 , <br />GLASS BLOCK SHALL BE INSTALLED PER THE FLORIDA BUILDING CODE RESIDENTIAL SECTION R160 <br />PROPER INSTALLATION MAX. 8" <br />FILL SOLID <br />BOTH CELLSVIL-V <br />1. <br />#5 REBj <br />(TYP,) <br />STD. 90 <br />HOOK (1 <br />Ella <br />7/ <br />t <br />15" <br />NOTCH WEB AT <br />FIRST 2 COURSI <br />12 <br />SEE <br />PLAN <br />JACK TRUSS PROVIDED BY—/ <br />TRUSS COMPANY OR 2x4 <br />#2 SYP @ 24" O.C. <br />SIMPSON <br />H2.5A w/ (10) <br />8d NAILS <br />4'-0" MAX SEE PLAN <br />2X4 SYP #2 CONT. (MATCH TRUSS DEPTH <br />IF TRUSSES USED) W/ (2) #6 X 4%" WOOD <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY <br />WALL USE (2) 1/4" X 31/2" TAPCONS AT 16" <br />O.C. <br />SECTION @ ENTRY L <br />SCALE: 3/4" =1'-0" SS <br />MASONRY WALL. SEE PLAN FOR <br />REINFORCING. PROVIDE LOWER <br />HOOKED DOWEL <br />W.W.M. AT PERIMETER <br />(1) #5 BARS CONT. WHERE THIS CONDITION <br />TOP WITH MIN. 3' OCCURS <br />COVER 6'-0" F.F. <br />P D <br />III <br />_III- <br />P III <br />—II—II <br />GRADE <br />N ° 'P <br />M e z <br />(2) #5 REBAR. MIN. 3" <br />16" MIN. Of COVER EA. WAY <br />SECTION AT DEEP MONO FOUNDATION <br />SCALE: 3/4" = V-0" <br />FILLED CELL PER <br />FOUNDATION PLAN <br />kR <br />YP.) <br />ME <br />:S <br />X <br />TRUSS <br />2X4 SYP — <br />EACH TRUSS <br />CONNECTOR <br />SEE LINTEL- <br />SCHED. <br />PRECAST LINTEL <br />UNACCEPTABLE INSTALLTION <br />DO NOT DO THIS <br />#5 REBAR (TYP) <br />�ST.90" HOOK (TYP.) <br />FILLED CELL INSTALLATION <br />SCALE: N.T.S. <br />2 X 4 #2 SYP SCAB TO SIDE OF <br />TRUSS AS SHOWN FOR O.H. UP TO 2'-6" <br />* DOUBLE 2x4 SCAB FOR 2'-6" TO 4'-0" O.H. <br />(2) 10d NAILS @ 8" O.C. <br />4N ` TO TRUSS TOP CHORD <br />FHO'T/y PLYWOOD SHEATHING <br />+ BLOCKING AS <br />+ REQUIRED <br />TO SUPPORT <br />+ SOFFIT <br />+ +rl <br />SEE ELEVATION <br />FOR OVER HANG <br />(MAX. 4'-0") <br />SECTION @ ROOF EXTENSION M <br />SCALE: 3/4" =1'-0" SS <br />Q= cuGGT n2 AND <br />FOR <br />SIMPSON HTT4 w/ (18) 10d x 1 <br />1/2" NAILS TO STUDS & (1) - <br />5/8" DIA. ALL THREAD ROD <br />EPDXIED w/ SIMPSON "SET" <br />EPDXY MIN. 6" EMBEDMENT & <br />3" MIN. EDGE DISTANCE <br />RETROFIT FOR MISSING MSTAM STRAP <br />SCALE: 3/4" = V-0" <br />IOTCN'�CB @ FIRST COURSE <br />H <br />SS <br />2"x BOT. PLATE W/ (2)10d @ 6" O.C. <br />3/4" PLYWOOD DECKING GLUED — <br />AND NAILED W/ 8d COMMON @ <br />6" O.C. EDGES AND 12" O.C. FIELD <br />ATTACHED WALL SHEATHING TO <br />2X BOTTOM PLATE W/ 8d @ 4" <br />O.C., 2 ROWS STAGGERED <br />�---2x BAND JOIST W/ FACE NAIL 1 Od <br />@ TOP & BTTM CHORD, AND (8) <br />FACE NAILS 10d @ TRUSS VERT. <br />WEB <br />METAL SEAT PLATE <br />NOTE: <br />LAP SHEATHING TO <br />BOTTOM OF BAND <br />JOIST TYPICAL <br />SIMPSON HGAM10KTA @ 12" O.C. <br />w/ (4)1/4x1 1/2" SIDS SCREWS <br />INTO BAND JOIST & (4)1/4"x2 3/4" <br />TITEN INTO K.O. BLOCK <br />RETROFIT FOR MISSING EMBEDDED STRAP <br />SEE TYP. 2-STORY WALL SECTION FOR ADDL. INFO <br />FILL 4 COURSES <br />SOLID <br />WiGROUT <br />FOR OVERHANGS BETWEEN OVER 1 1/2" <br />CONTACT ENGINEER OF RECORD FOR <br />FURTHER INSTRUCTIONS. <br />OVERRAN ' .;' •� .�" <br />RETROFIT WALL OVERHANG DETAIL (NTS <br />FOR OVERHANGS BETWEEN 3X' TO 1 1/2" <br />NOTE: FOR OVERHANGS LESS THAN 3/4" - NO REPAIR REQ'D. <br />1'-0" 5'-0" <br />SCALE: N.T.S. <br />#5 BAR <br />D . , 1011 CENTERED W/ <br />p H b° <br />IN TOP c <br />KNOCKOUT/ c� <br />° CHAIR BLOCK <br />MONO FOOTING <br />SIZE AND REINF. PER PLAN p °. <br />AND SECTION DETAILS -I <br />CLEAN FILL <br />DIRT r; Z <br />STANDARD c <br />96 HOOK N <br />#5 BAR IN <br />FILLED CELL t,° <br />'s v °s <br />STEMWALL FOOTING SIZE AND <br />MONO TO STEMWALL FOOTING REINF. PERLAN AND STEMWALL <br />SECTION DETAILS <br />SCALE: 3/4" =1'-0" <br />OTE: IF RETROFIT FILLED CELL CONDITIONS EXCEED (3) PER PROJEC' <br />ONTACT ENGINEER OF RECORD FOR ADDITIONAL INSTRUCTION. <br />EXISTING BOND BEAM. <br />DRILL 3/4"x5" MIN. HOLE SET BAR IN <br />EPDXY CAP TO PREVENT LEAKAGE <br />TOP SPACE BETWEEN EXISTING GROUT & NEW GROUT <br />MUST BE PACKED WITH NON -SHRINK GROUT (USUALLY t 2") <br />#5x6' EMBEDDED INTO EXISTING BOND BEAM <br />FILL CELL FULL HEIGHT W/ <br />NON SHRINK GROUT. <br />#5x6' EMBEDDED INTO <br />EXISTING FOOTING <br />DRILL 3/4"x5" MIN. HOLE <br />SET BAR IN EPDXY <br />EXISTING FOOTING <br />RETROFIT FILLED CELL DETAIL <br />(2) #5x6' IN CONC. <br />FILLED CELL <br />4" <br />A SECTION <br />1 SCALE: N.T.S. <br />SCALE: N.T.S. <br />w <br />zw <br />z C. W w <br />w a 0 O Q ri = J <br />F=-aoz w�,naF Z <br />000^ F'oozc) 0 <br />?�v�n o0}Fzo Lu <br />O¢ wR <br />w.>,Lm >iJZUE <br />Z w <br />-OLL w z�na¢O W <br />¢ w= H O w- 2 a 'U P <br />w Ln <br />LLz2Q ¢OOhac <br />¢..y � W W J=� <br />,w O <br />-_z_ <br />w- <br />U v i z ui Z z w 2¢ <br />a W o w w V <br />w o 6 w w z K H- 0 Lu <br />wo <br />==G ~�ww a <br />-ate owe N <br />a� <br />U � N <br />Nm <br />-4m Ln oo <br />T u u <br />ON Z = m LLi Lu <br />a a <br />mom & "' Q N <br />mom W 0 d <br />�mm W N= dam' 0 W w <br />_Z w O�ao 3 m <br />W -i N <br />0 u- ^ Q Lu <br />Y <br />CN <br />Z a o G <br />Luuj0 � <br />K a z 3 <br />LAJ IN Q � <br />o Z <br />O �° a <br />i <br />O <br />O <br />Z " <br />O�I� <br />4 <br />r>-i�MO <br />M <br />Q o Ln <br />• a In 2 V_ <br />Q LL <br />uM <br />00 <br />Z co <br />ww0F' <br />J0 <br />d- <br />U) <br />ui <br />ou) <br />uj <br />0 <br />V Z <br />Q <br />SCALE : AS NOTED <br />DATE : 05-07-2018 <br />SHEET NO. <br />ss <br />