Laserfiche WebLink
b <br />a <br />— — — — — — <br />I <br />I <br />I <br />I <br />I <br />— — — — — — — <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />L— — — — — — — <br />I <br />— — — — — — — — <br />2x8 P.T. BUCK -CONNECT TO BLOCK <br />W/ 1/4" x 31/4" TAPCON (1 1/4" MIN. <br />EMBEDMENT INTO BLK.) <br />1 X 4 FURRING <br />BLOCK HEADER <br />1/2" DRYWALL <br />8d NAILS AT 8" O.C. AT BUCK <br />2 x 8 45" DIAGONAL (4)10d NAILS INTO <br />BRACE(S) 2 x 8 BRACE/ BLKG. ' <br />7/16" OSB <br />BUILT UP PLWD. BUCK ARCH PANEL CUT HOLE IN O.S.B. FOR <br />SCRIBE (NOTCH) POLY -CELL IN THIS AREA <br />BACKSIDE TO FIT ARCH (4)10d NAILS INTO 2 x 8 <br />CONNECT W/ 8d NAILS BRACE/ BLKG. <br />INSTALL WDW. SCREW ANCHOR- x 4 SOLID BLKG. (FULL WIDTH OF WALL) BTWN. OSB <br />INTO ARCH BLKG. PER ARCH FACES W (4) 10d NAILS THRU OSB INTO 2 x 8 <br />INSTALLATION DETAILS A -A PROVIDE TAPCON PER WDW. INSTALLATION DETAILS OR THRU ­\ <br />1-1/2" THK. OR MORE BUCK WITHIN 6" MIN. OF START OF ARCH <br />ARCH DETAIL ,1 <br />SCALE: N.T.S. SS <br />DOOR JAMB (REFER 1X4 1/2" DRYWALL <br />DOOR JAMB (REFER 1 X 4 1/2" DRYWALL <br />DOOR JAMB (REFER <br />1 X 4 1/2" DRYWALL <br />TO SHT. SDW2-K1 <br />P.T. <br />TO SHT. SDW2-Ki <br />TO SHT. SDW2-K1 <br />FOR CONN. DETAILS <br />FOR CONN. DETAILS <br />FOR CONN. DETAILS 1 X 4 <br />1 X 4 <br />3-1/4" LONG X 3/16"0 <br />1 X 4 <br />FURRING <br />3/16"0 X 3" LONG FURRING <br />TAPCONS <br />3/16"0 X 3-1/2" LONG <br />FURRING <br />TAPCON. INTO <br />STAGGERED @ 16 <br />TAPCONS STAGGEREDLlX8 <br />yX8 <br />BLOCK@ SPACING „ <br />1X8 P.T. <br />O.C. 2-ROWS INTO <br />STAGGERED @ 16" O.C. <br />PER MANUFACTURE <br />MASONRY THROUGH 1-1 /2" DETAIL <br />MASONRY THROUGH <br />3�1 DETAIL <br />1x4 P.T. & 1x8 P.T. <br />1x8 P.T. & 2x8 P.T. <br />3/16" x 3 -1/2" <br />TAPCON @ 16" <br />O.C. & 4" FROM <br />iX4 P.T. <br />3/16" x 3 -1/2" <br />DOOR JAMB (REFER <br />1 X 4 1/2" DRYWALL <br />DOOR JAMB (REFER <br />EACH END W/ MIN <br />DOOR JAMB (REFER TAPCON <br />TO SHT. SDW2-K1 FOR <br />TO SHT. SDW2-K1 <br />2" EDGE DIST. <br />TO SHT. SDW2-K1 <br />CONN. DETAILS <br />FOR CONN. DETAILS <br />FOR CONN. DETAILS <br />10d @ 12" O.C. <br />1 X 4 <br />FURRING <br />2X8 P.T. WITH 3/16"0 X 3" <br />2x P.T. AS REQ'D <br />2X8 P T <br />LONG TAPCONS <br />STAGGERED @ 16" O.C. <br />2X8 <br />2x DETAIL <br />2 1/4" DETAIL <br />2-ROWS INTO MASONRY <br />3-1/4" DETAIL <br />BUILDOUT OVER SIZE DOOR -WINDOW ROUGH OPENINGS CC <br />SCALE: N.T.S. SS <br />BLOCK HEADER <br />1 X 4 FURRING <br />8d NAILS @ 8" O.C. AT BUCK <br />PROVIDE 2 x 8 DIAG. BRACE BT <br />VERT. BRACES WHEN HGT. OF <br />BRACE EXCEEDS 24" <br />2 x 8 VERT. BRACE(S) <br />BUILT UP PLWD. BUCK - <br />SCRIBE (NOTCH) BACKSIDE <br />TO FIT ARCH CONNECT W/ <br />8d NAILS <br />INSTALL WDW, SCREW---' <br />ANCHOR INTO ARCH BLKG. <br />PER INSTALLATION DETAILS <br />1 /4" MAX <br />SOLID BLKG. AT TOP BTWN. <br />ARCH BLKG. & BUCK <br />2'-0" <br />2 x 8 BUCK - CONNECT TO BLOCK <br />WITH 1/4" x 31/4" TAPCON (1 1/4" MIN. <br />1/4" MAX EMBEDMENT INTO ) 2 0 <br />SOLID BLKG. AT TOP BTWN. ARCH <br />BLKG. & BUCK <br />2 x 8 VERT. W/ (2)10d <br />NAILS AT EA. END -IF, <br />LEAVE A CUT OUT IN O.S.B. ON T <br />INSIDE TO ALLOW FOR INSULATION <br />TO BE INSTALLED <br />7/16" OSB ARCH PANEL <br />2 x 4 SOLID BLKG. (FULL WIDTH OF WALLS) <br />BTWN. OSB ARCH FACES W/ (4)1 Od NAILS EQUAL <br />THRU OSB INTO 2 x 8 <br />6_B ARCH DETAIL K <br />SCALE: N.T.S. SS <br />GLASS BLOCK INSTALLATION NOTES <br />A) COVER SILL AREA WITH A HEAVY COAT OF ASPHALT EMULSION. ALLOW EMULSION TO DRY <br />AT LEAST 2 HOURS BEFORE PLACING MORTAR. <br />B) ADHERE EXPANSION STRIPS TO JAMBS AND HEAD. MAKE CERTAIN EXPANSION STRIP <br />EXTENDS TO SILL. <br />C) SET A FULL MORTAR BED JOINT, APPLIED TO SILL. <br />D) SET LOWER COURSE OF BLOCK. MAINTAIN A UNIFORM JOINT WIDTH OF 3/8" PLUS OR MINUS <br />1/8". ALL MORTAR JOINTS MUST BE FULL AND NOT FURROWED. ALL MORTAR SHALL BE <br />TYPE "S" OR "N". STEEL TOOLS MUST NOT BE USED TO TAP BLOCKS INTO POSITION. (PLACE <br />A RUBBER CRUTCH TIP ON END OF TROWEL TO TAP BLOCK INTO POSITION.) DO NOT <br />REALIGN, TAP, OR OTHERWISE MOVE BLOCK AFTER INITIAL PLACEMENT. FOR SOLID GLASS <br />BLOCK IT MAY BE NECESSARY TO USE WEDGES IN THE MORTAR JOINTS OF THE LOWER <br />COURSES TO PREVENT THE MORTAR FROM BEING "SQUEEZED" OUT. <br />E) INSTALL PANEL REINFORCING IN EVERY OTHER MORTAR BED HORIZONTALLY AND IN JOINTS <br />IMMEDIATELY ABOVE AND BELOW ALL OPENINGS WITHIN PANELS. (THE SAME SPACING <br />SHALL APPLY TO PANEL ANCHORS WHEN USED AT JAMBS AND HEADS IN LIEU OF CHANNEL <br />OR CHASE SURROUNDS.) RUN REINFORCING CONTINUOUSLY FROM END TO END OF PANELS. <br />LAP REINFORCING NOT LESS THAN 6 INCHES WHENEVER IT IS NECESSARY TO USE MORE <br />THAN ONE LENGTH. DO NOT BRIDGE EXPANSION JOINTS WITH REINFORCING. INSTALL <br />REINFORCING AS FOLLOWS: <br />* PLACE LOWER HALF OF MORTAR IN BED JOINT. DO NOT FURROW. <br />* PRESS PANEL REINFORCING INTO PLACE. <br />* COVER PANEL REINFORCING WITH UPPER HALF OF MORTAR BED AND TROWEL <br />SMOOTH. DO NO FURROW. <br />F) PLACE FULL MORTAR BED FOR JOINTS NOT REQUIRING PANEL REINFORCING - DO NOT <br />FURROW. MAINTAIN UNIFORM JOINT WIDTH. <br />G) SET SUCCEEDING COURSE OF BLOCKS. SPACE AT HEAD OF PANEL AND JAMBS MUST <br />REMAIN FREE OF MORTAR. <br />H) STRIKE JOINTS SMOOTH WHILE MORTAR IS STILL PLASTIC AND BEFORE FINAL SET. AT THIS <br />TIME RAKE OUT ALL SPACES REQUIRING SEALANT TO A DEPTH EQUAL TO THE WIDTH OF THE <br />SPACES. REMOVE SURPLUS MORTAR FROM FACES OF GLASS BLOCKS AND WIPE DRY. <br />TOOL JOINTS SMOOTH AND CONCAVE, BEFORE MORTAR TAKES FINAL SET. (REMOVE <br />WEDGES FROM LOWER COURSES OF SOLID BLOCKS AND POINT THE VOIDS WITH MORTAR.) <br />1) AFTER FINAL MORTAR SET (APPROX. 24 HOURS), INSTALL PACKING TIGHTLY BETWEEN <br />GLASS BLOCK PANEL AND JAMB AND HEAD CONSTRUCTION. LEAVE SPACE FOR SEALING. <br />J) APPLY SEALANT EVENLY TO THE FULL DEPTH OF RECESSES IN ACCORDANCE WITH THE <br />MANUFACTURER'S APPLICATION MANUAL AND INSTRUCTIONS. <br />K) A MAXIMUM OF 60 SQUARE FEET OF GLASS BLOCK MAY BE INSTALLED IN ANY OPENING. <br />FOR WIND SPEEDS UP TO 110 MPH*, PER PITTSBURG CORNING RECOMMENDATIONS FOR <br />INSTALLATION OF GLASS BLOCK. <br />— SECTION <br />A -A <br />8" <br />1/4" x 31/4" TAPCONS <br />—LEAVE A CUT OUT IN O.S.B. ON THE <br />INSIDE TO ALLOW FOR INSULATION <br />TO BE INSTALLED <br />2 x 8 45 DrAGONAL BRACE AT EA. <br />FACE OF ARCH W/ (3) 10d NAILS <br />AT EA. END <br />PROVIDE TAPCON WITHIN <br />4" MIN. OF BRACE <br />START OF ARC <br />4' MAX. RAID. <br />SECTION <br />B-B <br />8" <br />EQUAL <br />20 ga. PANEL <br />ANCHOR <br />PROVIDE 2x <br />PROVIDE (2) MIN. CONT. W/ (3) <br />TAPCON AT EA. SIDE 12d NAILS <br />BUCK- (1) WITHIN 4" <br />MIN. OF START OF <br />ARCH <br />START OF ARC <br />4' MAX. RAD. <br />EXPANSION STRIP <br />1/4" EXPANSION BOLT (2 <br />PER ANCHOR) <br />EXPANSION STRIP <br />6" MIN. LAP SPLICE W/ <br />REINFORCING PANEL <br />N.T.S. <br />2X6 SYP #2 CONT. (MATCH TRUSS DEPTH <br />IF TRUSSES USED) W/ (3) #6 X 4%" WOOD <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY <br />WALL USE (3) 1/4" X 31/2" TAPCONS AT 16" <br />O.C. <br />JACK TRUSS PROVIDED BY <br />TRUSS COMPANY OR <br />2x6 #2 SYP @ 24" O.C. <br />ROOF SHEATHING ATTACHED <br />PER NAILING SCHEDULE <br />(5)12d NAILS <br />2X6 TO 2X4 , <br />6" MIN. LAP / <br />SPLICE NOTE: <br />SEE GLASS BLOCK INSTALLATION NOTES. <br />`— SEALANT <br />GLASS BLOCK DETAIL <br />GLASS BLOCK SHALL BE INSTALLED PER THE FLORIDA BUILDING CODE RESIDENTIAL SECTION R160 <br />e <br />PROPER INSTALLATION MAX. 8 <br />FILL SOLID <br />BOTH CELLSFIL <br />#5 REB <br />(TYP,) <br />STD. 90' <br />HOOK (1 <br />11L <br />ola <br />71 <br />*5A <br />NOTCH WEB AT <br />FIRST COURSI <br />12 <br />SEE <br />PLAN <br />JACK TRUSS PROVIDED BY—/ <br />TRUSS COMPANY OR 2x4 <br />#2 SYP @ 24" O.C. <br />SIMPSON <br />H2.5A w/ (10) <br />8d NAILS <br />4'-0" MAX SEE PLAN <br />2X4 SYP #2 CONT. (MATCH TRUSS DEPTH —/ <br />IF TRUSSES USED) W/ (2) #6 X 4%" WOOD <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY <br />WALL USE (2) 1/4" X 31/2" TAPCONS AT 16" <br />O.C. <br />SECTION @ ENTRY L <br />SCALE: 3/4" = l'-0" SS <br />MASONRY WALL. SEE PLAN FOR <br />REINFORCING. PROVIDE LOWER <br />HOOKED DOWEL <br />W.W.M. AT PERIMETER <br />WHERE THIS CONDITION <br />(1) #5 BARS CONT. OCCURS <br />TOP WITH MIN. 3" <br />COVER 6'-0" <br />F.F. <br />g°. ••�• I —III —I 11=1 11=1 11=1 11-' <br />MII1=1I1—I II1— ' -- <br />° 111=111=11 <br />• • ' 11I ITI I II <br />HE <br />1=III=1 1 <br />GRADE °• " .p . ° 111 T� 1 I- <br />m °. <br />N ° 'R <br />M - z <br />r <br />(2) #5 REBAR. MIN. 3" <br />16" MIN. 71, COVER EA. WAY <br />SECTION AT DEEP MONO FOUNDATION <br />SCALE: 3/4" = l'-0" <br />FILLED CELL PER <br />FOUNDATION PLAN <br />UNACCEPTABLE INSTALLTION <br />♦♦ DO NOT DO THIS >� <br />♦♦ #5 REBAR (TYP,) <br />1R ♦ ♦ ,, <br />♦♦♦ � <br />♦♦ STD. 90` HOOK (TYP.) <br />YP.) ♦ t7— <br />, <br />♦♦ <br />I <br />NOTCH' ;�RSTCOURSE <br />THE ,,, ♦♦♦ <br />S .� ♦' <br />FILLED CELL INSTALLATION H <br />SCALE: N.T.S. SS <br />X <br />+ + <br />+ + <br />+ + <br />+ + <br />+ <br />TRUSS <br />2X4 SYP — <br />EACH TRUSS <br />CONNECTOR <br />SEE LINTEL- <br />SCHED. <br />PRECAST LINTEL <br />2 X 4 #2 SYP SCAB TO SIDE OF <br />TRUSS AS SHOWN FOR O.H. UP TO 2'-6" <br />* DOUBLE 2x4 SCAB FOR 2'-6" TO 4'-0" O.H. <br />(2)1 Od NAILS @ 8" O.C. <br />TO TRUSS TOP CHORD <br />'TN PLYWOOD SHEATHING <br />SEE ELEVATION <br />FOR OVER HANG <br />(MAX. 4'-0") <br />BLOCKING AS <br />REQUIRED <br />TO SUPPORT <br />SOFFIT <br />SECTION @ ROOF EXTENSION M <br />SCALE: 3/4" = V-0" SS <br />CFF CHFFT n2 AND <br />FOR <br />SIMPSON HTT4 w/ (18)10d x 1 <br />1/2" NAILS TO STUDS & (1) - <br />5/8" DIA. ALL THREAD ROD <br />EPDXIED w/ SIMPSON "SET" <br />EPDXY MIN. 6" EMBEDMENT & <br />3" MIN. EDGE DISTANCE <br />RETROFIT FOR MISSING MSTAM STRAP <br />SCALE: 3/4" =1'-O" <br />Ix <br />z <br />O <br />Q <br />2 <br />U- <br />O <br />W <br />Q <br />U <br />2"x BOT. PLATE W/ (2)10d @ 6" O.C. <br />3/4" PLYWOOD DECKING GLUED — <br />AND NAILED W/ 8d COMMON @ <br />V O.C. EDGES AND 12" O.C. FIELD <br />ATTACHED WALL SHEATHING TO <br />2X BOTTOM PLATE W/ 8d @ 4" <br />O.C., 2 ROWS STAGGERED <br />—2x BAND JOIST W/ FACE NAIL 1Od <br />@ TOP & BTTM CHORD, AND (8) <br />FACE NAILS 1Od @ TRUSS VERT. <br />WEB <br />METAL SEAT PLATE <br />NOTE: <br />LAP SHEATHING TO <br />BOTTOM OF BAND <br />JOIST TYPICAL <br />SIMPSON HGAMIOKTA @ 12" O.C. <br />w/ (4)1/4x1 1/2" SIDS SCREWS <br />INTO BAND JOIST & (4)1/4"x2 3/4" <br />TITEN INTO K.O. BLOCK <br />RETROFIT FOR MISSING EMBEDDED STRAP <br />SEE TYP. 2-STORY WALL SECTION FOR ADDL. INFO <br />FILL 1st 4 COURSES <br />SOLID W/GROUT <br />FOR OVERHANGS BETWEEN OVER 1 1/2" <br />CONTACT ENGINEER OF RECORD FOR <br />FURTHER INSTRUCTIONS. <br />OVERHAN <br />RETROFIT WALL OVERHANG DETAIL (NTS <br />FOR OVERHANGS BETWEEN 3/4" TO 1 12' <br />NOTE: FOR OVERHANGS LESS THAN 3/4" - NO REPAIR REQ'D. 771 <br />1'-0" 5'-0" <br />NISH <br />SCALE: N.T.S. <br />#5 BAR <br />Loft <br />p o CENTERED W/ <br />90' H ° IN TOP 9 <br />° KNOCKOUT / it <br />CHAIR BLOCK <br />MONO FOOTING_ <br />SIZE AND REINF. PER PLAN p ° <br />AND SECTION DETAILS -I <br />CLEAN FILL <br />DIRT Z <br />STANDARD o <br />o N <br />#5 BAR IN 90' HOOK <br />FILLED CELL o , -; iv , -, <br />IV <br />ss- - <br />-s. <br />STEMWALL FOOTING SIZE AND <br />MONO TO STEMWALL FOOTING REINF. PERLAN AND STEMWALL <br />SECTION DETAILS <br />SCALE: 3/4" =1'-0" <br />OTE: IF RETROFIT FILLED CELL CONDITIONS EXCEED (3) PER PROJEC' <br />ONTACT ENGINEER OF RECORD FOR ADDITIONAL INSTRUCTION. <br />EXISTING BOND BEAM. <br />DRILL 3/4"x5" MIN. HOLE SET BAR IN <br />EPDXY CAP TO PREVENT LEAKAGE <br />TOP SPACE BETWEEN EXISTING GROUT & NEW GROUT <br />MUST BE PACKED WITH NON -SHRINK GROUT (USUALLY t 2") <br />#5x6' EMBEDDED INTO EXISTING BOND BEAM <br />FILL CELL FULL HEIGHT W/ <br />NON SHRINK GROUT. <br />#5x6' EMBEDDED INTO <br />g EXISTING FOOTING (2) #5x6' IN CONC. <br />cQn N FILLED CELL <br />DRILL 3/4"x5" MIN. HOLE <br />SET BAR IN EPDXY <br />�4' SAW CUT <br />EXISTING FOOTING A SECTION <br />1 SCALE: N.T.S. <br />RETROFIT FILLED CELL DETAIL <br />SCALE: N.T.S. <br />�,�orlisrrr/i <br />00 <br />Z • •® �c ;- <br />a. 4C,-) .� <br />Cc . s . <br />® ®, " " <br />,ram �� .®••• ®® �� ,�, <br />��rrrla 'k %1�k <br />W <br />>- <br />Z� oQwx <br />o <br />=aa Z <br />w Q O 0 O <br />U 2 Q E <br />aZJw0W <br />� p <br />wZjno <br />u3gz�LL <br />ago a <br />�wO Zv'�iwa0Z <br />a LL� a�aOQ CQcz <br />H� <br />LLa°P w�w�xOLL 0 <br />H Z m z Z w> Z O <br />W (.JKU W Z C— I.L <br />>wol7 w wlz—.7w=a 0 <br />mo <br />wzZH_ <br />n J <br />wp� =w�wwx <br />~ <br />= <br />U a H W ¢ <br />-ate owe N <br />a� w <br />lD N <br />�.+ m N M <br />o Ln 00 <br />� (' w L" �# 4M <br />mmm mZ Zm w w <br />mmmm lot <br />mm W � Ln <br />Lu J <br />Vf "I m0 w w <br />0 vI <br />'Z w - o N 2 <br />v 0 LL ^ Q <br />Y <br />'i <br />Z aroo <br />L u w 0 o 0 0 <br />x a Z Q 3 <br />Lu N J D_ cr- <br />ag o a Z <br />O a <br />i <br />L# <br />O <br />z cV <br />0 � <br />aJ <br />>U�o <br />z <br />M <br />Q -gyp Lo <br />CL NLn <br />Ln <br />Q LL <br />cl� U <br />< - � <br />E <br />W O <br />w <br />JkD <br />d- <br />ui <br />O <br />uj <br />0 <br />V Z <br />SCALE : AS NOTED <br />DATE : 05-07-2018 <br />SHEET NO. <br />