My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36002 Saddle Palm Way
Zephyrhills
>
Building Department
>
Building Plans
>
36002 Saddle Palm Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 2:54:20 PM
Creation date
2/19/2025 8:45:35 AM
Metadata
Fields
Template:
Building Plans
Street #
36002
Location
Saddle Palm Way
Contractor
Lennar Homes LLC
Building Plans - Permit #
20430
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
O <br />35-SH <br />0 <br />0 <br />N <br />LO <br />4- <br />02 <br />TYP @ 2 STORY <br />J <br />S6 <br />co <br />co <br />E <br />0 <br />00 <br />-r;n'_n" <br />4'-8" 8'-6" <br />V-10" <br />11'-6" <br />9'-6" <br />7-0" <br />O <br />O <br />O <br />AO <br />4. <br />O <br />AC PAD <br />H.B. 35-SH <br />6068 <br />S.G.D. <br />TEMP. <br />25-SH <br />EGRESS <br />25-SH <br />23-SH <br />TEMP. <br />FAMILY R M <br />8'-8" CLG. <br />CARPET <br />(4) 2 X 4 #2 SPF <br />STUDS W/ 5/8" <br />ANCHOR BOLT & <br />(18) 10d NAILS <br />MASTER <br />SUITE <br />" <br />8 -8 CLG. <br />CARPET <br />17'-7$' <br />rn o <br />_ U) <br />ow gZ <br />X °°o ° <br />M �' m co <br />TB <br />� o <br />ASTER <br />AT H R <br />8'-8" CLG, <br />TILE <br />-- CIO <br />868 <br />3'- <br />oo <br />M <br />Ao <br />C T <br />00 <br />60b <br />q' <br />G <br />S3 <br />W/#2SPF <br />@ 12" O.C. <br />r <br />2668 <br />BI-FOLD <br />w �o <br />Z _ <br />mod,°° <br />i� <br />i <br />to <br />N <br />FIELD VERIFY HEIGHT <br />PER MECHANICAL <br />CONTRACTOR <br />� CO <br />I <br />20' 4$' <br />(3) 2 X 4 #2 SPF <br />STUDS W/ HTT45 <br />W/ 5/8"ANCHOR <br />5'-11$" <br />2868 3' 11" <br />3'-6" 4'-3" <br />V-3" <br />12'-5" <br />I <br />5' 4" 2 12 <br />C <br />NOAILS <br />+42" SLOPING <br />HALF WALL <br />& (18) 10d <br />T C <br />G C <br />S3 H1 <br />R.A.G. <br />T H2 <br />AU <br />? 8'-8" <br />DRY <br />LG. <br />I bN <br />�* <br />1 <br />I HANSON <br />I <br />I j <br />v l 1 <br />I I <br />L-- <br />I <br />BO <br />--- <br />R&S <br />I <br />1 06 <br />I <br />W.I.C. I <br />8'-8" CLG. I <br />I <br />I <br />--------J <br />�6'd' <br />HU <br />CAFE <br />�� <br />8TILELG <br />�� <br />Cl) <br />UP <br />16R <br />E LATFO <br />MS <br />I <br />1 <br />I <br />I <br />I <br />I <br />1 <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I GG <br />I S3 <br />I H1 <br />110 <br />I <br />11 <br />I <br />12 <br />I <br />13 <br />I <br />14 <br />I <br />15 <br />I <br />16 <br />I <br />17 <br />I <br />18 <br />I <br />1g <br />=1N <br />~ <br />- <br />5'-0" <br />3. "X7P.L.1BE <br />W.H. <br />CC <br />S3 a <br />BUILDER TO PROVIDE <br />APPLIANCE <br />PROTECTION WHEN <br />REQUIRED PER FBC <br />- - <br />52" GG o <br />T <br />S3 - <br />I H2 GG <br />1 S3 <br />I -8 C <br />00 -1 <br />N <br />H2 <br />2868 <br />- - - - <br />1 12 <br />- - - - - - <br />1113__ <br />111 _ <br />1�15 <br />1116- <br />I I <br />o Q <br />(3) 2 X 4 #2 SPF <br />STUDS W/ HTT45 <br />W/ 5/8" ANCHOR <br />BOLTS&(18)10d <br />CC NAILS <br />EDGE OF SLAB 2" <br />BEYOND WALL <br />DRYER VENT <br />THRU WALL <br />QI <br />0 °0I <br />0 Q I <br />I _ <br />- <br />_ <br />- <br />N <br />C_o <br />5 W <br />BOLTS <br />NAI <br />UM <br />5/8" <br />S <br />G <br />B <br />W/ <br />9 <br />HTT <br />n I <br />m I <br />l <br />A <br />(1 <br />CHO <br />10d <br />1) <br />o <br />- - - - - - <br />.. .. <br />m I <br />t <br />1 <br />I <br />__- <br />- - - - - <br />r---� <br />D.W. <br />a <br />L---J <br />- - - - - - <br />ze <br />O <br />- <br />(4)2X4#2SPF <br />STUDS W/ (4) 16d <br />NAILS @ BASE <br />it <br />_ <br />HZ <br />CC <br />S3 <br />l <br />s' <br />3'-8" <br />3 CAR GARAGE <br />8'-8" CLG. <br />20'-0" <br />KITCHEN4 <br />SINK wl DISP <br />8'-8"CLG. <br />TILE <br />I OPT. <br />REF. <br />1 <br />I <br />N <br />d� <br />00 <br />1 <br />5'-271,-5'-111- <br />14'-10" <br />RANGE 1 <br />1 <br />' <br />1 - 27 27 <br />is <br />a N 66 <br />wLLJ PANTR r rr kL4' <br />�, C 8' 8„ - <br />f TIE 1 0 <br />-_IH_DR_A_T_81I'-0" _ <br />IWIMilliN J. _1 _ L <br />SIN <br />- <br />CC <br />S3 <br />r----------------------- <br />I <br />I <br />I <br />o <br />' <br />00 <br />T <br />--------- <br />I <br />I <br />5 <br />16" DDEEEP <br />r F 0 R <br />' <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />6-82" 5'-72' V-78" <br />5'- 14' <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />16 x 7 OVERHEAD DOOR <br />I <br />I <br />FLEX <br />8 -8 CLG. <br />CARPET <br />°0I <br />�I <br />OP <br />- <br />_ <br />0 <br />D <br />I S3 i <br />1 8 x 7 OVERHEAD DOOR I <br />---------------------- <br />---------------------- <br />O <br />-------- <br />-------- <br />H <br />NOTE: FINISHED WALLS <br />TO BE FLUSH. VERIFY IN <br />I <br />FIELD. <br />o O <br />I <br />TYP <br />O O <br />25-SH 25-SH <br />EGRESS <br />"' I <br />I <br />ENTRY_____ <br />GARAGE <br />_ <br />3'-10" 3' 10" 7'-8" <br />4'-0" <br />2 0" " 8'-0" <br />1'-4" <br />'-0" <br />16'-0" <br />V-8" <br />16 4" <br />6-0" <br />10'-0" <br />18'-8" <br />50'-0" <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H 1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2600 PSI <br />H6 <br />(2) - 1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2600 PSI <br />H7 <br />(2) - 1 314" X 16" <br />LVL 2.0E Fb=2600 PSI <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2600 PSI <br />Follow Q/S4. See n for <br />- 2X4 SYP W/ 1/2" <br />R.A.G. <br />FIL Bearing Wall Cal Out When <br />FLITCH PLATE <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />TYP @ 2 STORY <br />J <br />S6 <br />.(3)2X4#2SPF <br />STUDS W/ HTT45 <br />W/ 5/8" ANCHOR <br />BOLTS & (18) 10d <br />NAILS <br />TYP @ 2 STORY <br />J <br />S6 <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection. <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection. Openings from a private garage <br />directly into a room used for sleeping purposes shall not be <br />permitted. Door between garage and residence shall be equipped <br />with solid doors not less than 1 3/8" in thickness, solid or <br />honeycomb -core steel doors not less than 1 3/8" thick, or <br />20-minute fire -rated doors. <br />R302.5.2 Duct Penetration. Ducts in the garage and ducts <br />penetrating the walls or ceilings separating the dwelling from the <br />garage shall be constructed of a minimum No. 26 gage (0.48 mm) <br />sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl <br />duct board, or other approved material and shall have no openings <br />into the garage. <br />R302.5.3 Other Penetrations. Penetrations through the separation <br />required in Section R302.6 shall be protected as required by <br />section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated from the dwelling as per the <br />following: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies- Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills. <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 ni above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools, Section R4501.17.1.9 <br />All doors and windows providing direct access from the home to <br />the pool shall be equipped with an exit alarm complying with UL <br />2017 that has a minimum sound pressure rating of 85 db at 10 <br />feet. Any deactivation switch shall be located at least 54 inches <br />above the threshold of the access. Separate alarms are not <br />required for each door or window if sensors wired to a central <br />alarm sound when contact is broken at any opening. <br />M1507.2 Recirculation of Air. <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />recirculated within a residence or to another dwelling unit and shall <br />be exhausted directly to the outdoors. Exhaust air from bathrooms <br />and toilet rooms shall not discharge into an attic, crawl space or <br />other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />OPENING PRESSURES <br />ENCLOSED-EXPOSURE"C" <br />OA <br />+29.7 / -30.8 <br />© <br />+29.7 / -39.2 <br />+28.3 I -30.8 <br />�D <br />+28.3 / -36.4 <br />O <br />+26.6 / -28.0 <br />O <br />+26.6 / -32.2 <br />O <br />SEE SN SHEET O SEE SN SHEET <br />'140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />+34.0 / -44.8 <br />WALL LEGEND <br />j11111111111111111MASONRY@8& <br />TYP. 2x FRAME WALL <br />r BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR BEARING <br />ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND <br />REQUIRES NO UPLIFT CONNECTORS TO FLOOR <br />SYSTEM <br />AREA TABULATION "A" <br />1ST FLOOR LIVING AREA 1880 <br />2ND FLOOR LIVING AREA <br />1375 <br />LIVING TOTAL 3255 <br />GARAGE 679 <br />ENTRY 36 <br />TOTAL AREA 3970 <br />INSULATION REQ. <br />LOCATION <br />R-VALUE / TYPE <br />EXT CONC WALL <br />R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 <br />R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 <br />R-19 KRAFT FACED <br />FIRST FLOOR PLAN E L E V (INSTALL <br />A CONDITIONED CEILING RBLOWN-IN <br />BAFFELS AT EAVE) <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />SCALE: J4"=1 r-01 (GARAGE / LIVING) <br />o <br />C', <br />0 <br />Z N <br />13 <br />:* <br />t,l 0 <br />W cn <br />a--+ W <br />p <br />DOOf <br />�� r--- <br />o <br />i6 U <br />�� <br />m <br />W <br />i -E <br />CDM <br />0) (M <br />a m M <br />_ <br />O o 0 <br />C) <br />' I o <br />z: " o <br />o <br />¢ conv <br />� 0 <br />Qv <br />M < o <br />Al <br />B D• <br />N C 8 D•C <br />N �D <br />�01 zit� oo <br />gN�4�z <br />_Z IW <br />u�, z° Isss <br />U) <br />UA <br />imYJ <br />Z CU <br />sissisO <br />WLZ,* <br />`\j, <br />4r,\ 4 0g4 <br />LU <br />LU <br />U ^'! <br />•. <br />G�F <br />% J J <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seat is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />L NA <br />4600 W. Cypress St, Suite 200 Tampa, FL 33607 <br />www.LennarTampa.com <br />Ozo <br />�Q <br />z a <br />f a <br />F <br />Lu < W_ <br />UZOO <br />FzF-UZZ <br />s O w <br />z <br />Q <br />O <br />0 <br />J <br />O N <br />o <br />0-zz <br />LU <br />ass <br />c <br />r o <br />2:z <br />-a <br />o <br />CZL <br />Z <br />fu <br />N` <br />O <br />\1' <br />Y <br />(n <br />v <br />J <br />L <br />U <br />�n <br />N <br />T <br />o00 QUA <br />.:,..`.,. <br />Z o < <br />cV <br />a 0 <br />z< <br />Z<Z� <br />a<U2 <br />N <br />-Dz� <br />Z <br />Z <br />Uj <br />CV <br />Ln <br />LU <br />cca2�i <br /><,Qz U, <br />J <br />ri <br />WC <br />�oY <br />O~ <br />M <br />G <br />Q <br />Q <br />Z <br />8 <br />�¢Z <br />zi� <br />ZS <br />ao <br />m <br />06 <br />2 <br />g <br />LU <br />= <br />�z <br />< Lu <br />a <br />V) <br />s <br />SCALE : AS NOTED <br />DATE : 6/20/2018 <br />TECH: MJAM ES <br />VERSION N0. 4ol <br />SHEET NO. <br />1.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.