My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36002 Saddle Palm Way
Zephyrhills
>
Building Department
>
Building Plans
>
36002 Saddle Palm Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 2:54:20 PM
Creation date
2/19/2025 8:45:35 AM
Metadata
Fields
Template:
Building Plans
Street #
36002
Location
Saddle Palm Way
Contractor
Lennar Homes LLC
Building Plans - Permit #
20430
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />NEMA 1 <br />200 AMP <br />#14 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to. WH <br />#10-3 copper to Dryer <br />MAIN <br />O2/0 <br />or 4/0 SER Alu <br />200 amp <br />150 amp <br />POWER CO. FEED <br />INTERSYSTEM <br />JuL <br />Bare Cu Ground <br />BONDINGUNDING <br />WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 14, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />rn <br />3v <br />K;�-- <br />HALF -SWITCHED DUPLEX OUTLET <br />0 <br />v <br />SPECIAL PURPOSE OUTLET <br />o <br />DUPLEX OUTLET IN FLOOR <br />0 <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />I <br />°O <br />24 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />N <br />CEILING MOUNTED LIGHT FIXTURE <br />0 <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />N} <br />o <br />,I' <br />WALL MOUNTED LIGHT FIXTURE <br />� <br />o <br />J <br />' <br />RECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />LO <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />Q <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />N <br />c <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />a <br />o <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />`v <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />y <br />TELEPHONE (OPTIONAL) <br />T© <br />TELEVISION (OPTIONAL) <br />o <br />� 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />.o <br />ELECTRIC METER <br />ELECTRIC PANEL <br />J <br />DISCONNECT SWITCH <br />o <br />® <br />SPEAKER (OPTIONAL) <br />cV <br />04 <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />t„ <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />68 <br />(1) PHONE LINE, (1) DATA PORT <br />r---------------------------------------------------------------------------------------------� <br />I i <br />I i <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I i <br />I I <br />I i <br />I I <br />I i <br />I I <br />I I <br />I i <br />I i <br />I I <br />I i <br />i <br />I I <br />I <br />I i <br />I I <br />I I <br />I I <br />I <br />I <br />I I <br />I I <br />I I <br />I I <br />I I I I I I I I I I <br />I I L f f h� LIGHT W/ <br />I I B L NWI ICI I I I SWITCH IN <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />— — — — — — — — — — — — J <br />UPPER ELECTRICAL PLAN <br />SCALE: %4"= V-0" <br />i <br />Z M <br />_ o <br />Z <br />Z <br />Z <br />V <br />c�7 <br />�Uj <br />�V — <br />OW <br />E <br />_=) <br />U <br />nr- <br />m N <br />W E <br />F — <br />m M cM <br />N -00 M <br />Soi <br />pso <br />1 N <br />Od <br />L a: M <br />Q rn <br />mom= o <br />U) o- o <br />0 <br />� <br />rn ¢ d <br />Al® <br />B D® <br />N C 8 D C <br />��_ea.uYmo <br />N N <br />ca c� <br />Z W Ri.r 0�OZ w� Z�,6.] <br />U) <br />W <br />W V ¢ CLLL L <br />N v = <br />z N p <br />a <br />LLLU <br />OC CID <br />c) <br />oU U o <br />WWW.FDSENG.COM <br />0 <br />N <br />O <br />N <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />4600 W. Cypress St, Suite 2001 Tampa, FL 33607 <br />www.LennarTampa.com <br />oZ <br />¢f <br />�r <br />Uz80 <br />z w Y <br />E=ZZ <br />z�ZW <br />d 1 <br />OLLJLLN <br />/ \ <br />j <br />F <br />CL� <br />Zo <br />>- 8 <br />f <br />o <br />Z <br />2 <br />//��.�� <br />fu <br />` ' <br />V <br />_U <br />(4z3 <br />F <br />a� <br />lU <br />U <br />Z <br />0 <br />Nr <br />W <br />9Z <br />U <br />Ul <br />N <br />J <br />Uj <br />> 9 <br />°00 <br />o' <br />M <br />IoC <br /><YP <br />J "'Y <br />LU <br />LL <br />w5md <br />P CL <br />�0. � <br />CL <br />wWa <br />LL <br />Q <br />Ln <br />0-0 <br />opi90 <br />Z <br />N <br />WSXLL <br />Z <br />�o''0'!j <br />LU <br />LU <br />¢wu-7 <br />�2 Z o <br />�--I <br />LU <br />Z <br />z <br />0 <br />Cal—' <br />(7C7 <br />LU <br />� Z <br />4 w <br />,-+ <br />a <br />V) <br />o <br />SCALE : AS NOTED <br />DATE : 6/20/2018 <br />TECH: MJAM ES <br />VERSION NO. 4ol <br />SHEET NO. <br />4.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.