My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36339 Well HIll Way
Zephyrhills
>
Building Department
>
Building Plans
>
36339 Well HIll Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 9:26:23 AM
Creation date
2/19/2025 8:45:58 AM
Metadata
Fields
Template:
Building Plans
Street #
36339
Location
Well Hill Way
Contractor
Lennar Homes LLC
Building Plans - Permit #
6704
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METAL LATH <br />WALL SHEATHING <br />I'i Ir'I I`1 <br />[ Imo........... <br />E <br />...... ................... ................ .. .... . .... <br />16GAxl-1\2" LONG (3/4"-1" CROWN) g'. J.. <br />STAPLES @ 6" O.C. VERT BETWEEN M4X................................ „ „- „ <br />is _::..... 16GAx1-1/2 LONG (3/4 1 <br />STUDS (NOTED THUS:—) - OFFSET CROWN) STAPLES @ 6" <br />STAPLES BETWEEN STUDS AS SHOWN O.C. VERT INTO STUDS <br />(NOTED THUS:—) <br />METAL LATH ATTACHMENT DETAIL <br />REV. 09.24.21 SCALE: 3/4" = V-0" <br />*DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 703.7.1 LATH* <br />**ONLY APPLIES TO LENNAR TPA/JAX** <br />10'-0" <br />TANK -LESS W/H <br />CORNER OF <br />HOME H C G <br />GARAGE SIDE O O O <br />5'-0" <br />STUB -OUT FOR 1 �_� o 0 0 <br />LO <br />GAS METER O o <br />U <br />O {_ <br />N z0 <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />**ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-Y <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16-5" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'4' <br />(2) 16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'-4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" or 7/el <br />5000s 1.8/1.7 <br />wood panels <br />Two 3/4" wood panels or 2 x _ <br />P <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 314" wood panel <br />1-1/8" or two 1/2" <br />:65:0:Os 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />60 2.0 <br />wood panels <br />2x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />1/8" gap ° <br />x � <br />.r <br />FILL CELL <br />Cn <br />w <br />C> STD. 90° <br />CONT. #5 <br />HOOK <br />BAR <br />STD. 90° HOOK <br />BOND BEAM <br />SIMPSC <br />wl (22) <br />NAILS 1 <br />CONT. #5 <br />BAR <br />#5 CONT. <br />5/8"0 <br />THRU <br />BOLT <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM STEP <br />BOND BEAM <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />Q <br />BEARING COLUMN <br />SEE PLAN FOR REQ'D <br />PLYWOOD FLOOR <br />COLUMN AND <br />SHEATHING PER PLAN <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING(fJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br /># OF 2nd FLOOR <br />Solid block all posts from <br />STUDS <br />above to bearing below. <br />SECTION @ INT. BRG. WALL <br />N.T.S. <br />118" min. <br />2" max <br />) Small gap 2" min. <br />• � 4 max. <br />y <br />_ a <br />Clinch nails <br />when <br />possible <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4) Place joists together and nail from each side with 2 rows of 10d nails 2x4/Plywood/OSB web stiffener 2" min. <br />4" <br />required when indicated r <br />max. <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite qio <br />OF THE JOIST ASA REQUIRED LEAVING)/8" GAP TOP sides b 6". -Hangers with side nailing. <br />@ Y- Hangerswithsidesnotcontaining WEB STIFFENER <br />t. <br />DOUBLE JOIST CONNECTION topflange ofcuts <br />- Birdsmouthth cuts.. <br />N.T.S. <br />Under 2nd floor Cnh,mn ,er/ InnHe <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />* Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />wall or beam below.* <br />consideration. Check <br />local building <br />code for appropriate <br />details in <br />One 10d box <br />areas=20 of high <br />or=20 sinker <br />lateral load. <br />nail each side <br />at bearing. <br />Squash block / <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />NO HOLES (EXCEPT <br />KNOCKOUTS) ALLOWED <br />IN BEARING ZONES —7 <br />DO NOT cut, notch <br />or drill flanges <br />Boise Joist Blocking <br />Use 3" (10d) nails at 6" o.c. <br />Load bearing walls <br />higher than 15001b <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or_tz <br />Web Stiffener Fastener Schedule <br />Joist Bearing Location <br />Series I Depth I End Intermediate <br />01 <br />BCI5000 <br />9-1/2" <br />2-8d <br />I 2-8d <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />I 5-8d <br />BC16000s® <br />BC16500s® <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />! 2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BC160s® <br />11-7/8" <br />2-8d <br />3-8d <br />14' <br />16" <br />2-8d <br />2-8d <br />_ 5-8d <br />6-8d <br />BCI90s® <br />11-7/8" <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />SIMPSC <br />wl (22) <br />NAILS 1 <br />R TRUSS <br />OP PLATE <br />�.0 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON META12 / <br />Plumbing META12 TSS INSTALLATION <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />Joist <br />�When joists meet over wall, provide <br />1 3/4" minimum bearing for each. I -Joist can be offset <br />Provide adequate bearing for each lapped joist. Use 10dx3" nails at 6"o.c. for all joist <br />J <br />blocking panel *Non -stacking walls <br />@ INT. BRG. WALL require additional consideration. <br />10d nails SECTION — <br />N.T.S. <br />MINIMUM SPACING = 2x GREATEST <br />D DIMENSION OF LARGEST HOLE <br />(see table below) (KNOCKOUT EXEMPTS) D <br />(see table below) <br />C ❑ co <br />6„ A 1)/2" ROUND HOLE MAY 6„ 6" DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1)/2" <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1y2' <br />.Any 166'joist . _ <br />- - spa_c�? - <br />T-9' <br />VA" <br />1 Z' <br />1 _2,° <br />1'-3" 1, 3' <br />V-7" <br />4 -1'1" <br />mil" <br />2' <br />3-2' <br />3-7' <br />12 <br />T4Y' <br />1,_1,. <br />1, 2 <br />1 2" <br />1, 3' T-9' <br />2'-4" <br />2'-11,. <br />3- 7 <br />4! Z' <br />4-9- <br />9-4" <br />16 <br />T-t)'° <br />T-I" <br />1, Z' <br />.1, �,. <br />1, 7"° 2-6 <br />3-2' <br />3'_10" <br />4'-9" <br />S'-7" <br />6-4. <br />7 2'" <br />20 <br />T-a' <br />1'-1„ <br />1, <br />1, 2" <br />2'-a. 3-a- <br />4-t)" <br />4' 10" <br />6-11,. <br />6-11" <br />7'-11" <br />8'-1T <br />24 <br />V-a' <br />T-1,. <br />1, -2° <br />V-3" <br />2` 3-7" <br />4-9° <br />5'-10,. <br />7"-2" <br />S'-4` <br />1 9-6" <br />1C)' <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN, SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1%" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE 1%" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALL SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />up to 3' to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S. <br />Jc <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />00 <br />FINISH GRADE <br />Backer block (12" wide min.) I i _ <br />Nail with 10-10d nails. - — <br />Install tight to top flange. <br />SLEEVE THRU STEM •' <br />SEE PLAN FOR 4.— <br />FOUNDATION INFO ` G <br />STEM FOUNDATION <br />\ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gap <br />I <br />1 <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />eb stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />0.6 X Joist <br />" `depth <br />t0j <br />o� <br />I -JOISTS BUCKETS <br />N.T.S. <br />GRADE <br />REINF. SEE PLAN <br />rvu Unmx 1+ rvu <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />:�v <br />LOCATION OF <br />SECOND H10A <br />° ° �° <br />(WHEN <br />SIMPSON H10A <br />° <br />REQUIRED) <br />w/ (18) 10d x 1 1/2" <br />NAILS <br />UPLIFT = 1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4' 0" <br />CENTERED @ PIPE <br />PENETRATION <br />, ® . . a <br />i111=111_ll A A. <br />" -I j l <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />4 d <br />d °A-►Ililll��, <br />ul <br />SEE FND. PLN. <br />SIZE & REINF. <br />12" BELOW PIPE VERTICAL THRU FND. <br />GRADE <br />TOP (2) #5's x 4' 0" <br />CENTERED @PIPE <br />PENETRATION <br />O A <br />a <br />PVC OR SCH40 SLEEVE <br />r— PLUMBING LINE <br />d <br />A / <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION PLUMBING LINE <br />, Q A <br />C <br />d Aa. A Aa G <br />d <br />I —I a a I I —III —I I; <br />-I 15111-1 a ° I -I- <br />I <br />a <br />SEE FND. PLN. <br />SIZE & REINF. <br />cry <br />N <br />O <br />C2 :�i <br />v �r <br />mvCQ <br />--$�,,< <br />C Ct <br />.Jf <br />ciz- ro <br />� CD <br />C E <br />o <br />� v <br />v G r . M <br />`N <br />v <br />x <br />!4 `•rlkP�lfEt�rl�i <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />U! <br />* W <br />NAM I-8 <br />4 <br />, N <br />O C. <br />N <br />S' ° <br />UJ o <br />- <br />U LL <br />77 J <br />r` r; <br />M <br />a <br />a rd 7i w ° <br />��N' <br />Z <br />O <br />t V <br />W <br />iT z <br />_Z <br />LL <br />00 O < O zu <br />'N � Z <br />4 <br />ao <br />U � H <br />0 o00 <br />W <br />o o <br />z ID N <br />z o <br />Q <br />— <br />E3 <br />to <br />z <br />t'13 <br />ry <br />U <br />O,,, <br />Vcn <br />un <br />o <br />n <br />usa <br />ru <br />U <br />U <br />_U� <br />a <br />=Yv <br />U 'o y <br />° <br />C U) <br />w® <br />W <br />� <br />M <br />p <br />Z <br />< <br />6 <br />co E <br />o o <br />E O <br />wZ <br />ze <br />oLa <br />rC6 <br />00 <br />O ie <br />¢ <br />C <br />0Wz <br />40 o <br />� <br />nd z <br />o <br />Z <br />�w <br />¢o <br />mo <br />�mQw <br />zm� <br />o< <br />go <br />to <br />T <br />aLL <br />dZ <br />W <br />W <br />m <br /><� <br />5E <br />�3 <br />o <br />w <br />wa <br />;o <br />NJ <br />o <br />ol< <br />,o <br />>M <br />ON <br />1 <br />2 <br />` <br />L <br />t6 O <br />O <br />Cfl <br />0 <br />VJ ° <br />N <br />LCL <br />r <br />m <br />O <br />CV)O <br />CQ <br />M N <br />LO <br />N <br />Q <br />c,) <br />*` <br />(0 <br />M M <br />o <br />Z <br />M <br />z <br />7 <br />E O <br />vi LO <br />co <br />c <br />d <br />U <br />_0 p <br />JOB <br />NO : <br />23-0610 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />SIN 1 <br />�I <br />— — -- - - - <br />
The URL can be used to link to this page
Your browser does not support the video tag.