Laserfiche WebLink
ALL STAIR STRINGERS <br />AND TREADS TO BE <br />#2 SYP (MIN.) <br />THREADS, RISERS, AND <br />3/4" PLYWOOD NOT <br />SHOWN IN DETAIL FOR <br />CLARITY <br />ALL WOOD TO WOOD <br />CONNECTIONS TO BE <br />GLUED (PL 200) AND <br />NAILED (MIN. (2)16d). <br />13/4x11 <br />VL <br />2x4 UNDER STRINGER - <br />GLUED AND NAILED TO <br />LANDING <br />2x4 UNDER STRINGER GLUED A <br />NAILED TO LANDING BLOCKING <br />D <br />2x4 PT NOTC <br />INTO STRINGER <br />H D <br />—2x8 BLOCKING FOR STRAP <br />L-1x4 blocking <br />SIMPSON MSTA21 w/ (16) 10d NAILS E <br />FLAT STRAP NAILED TO RISER AND <br />THEN WRAPPED AROUND STUD - <br />PLAN VIEW <br />SCALE: " = T-0" <br />E: <br />THESE DETAILS ARE NOT PLAN <br />SPECIFIC. THEY ARE PROVIDED TO <br />YOU AS A STANDARD TO CONSTRUCT <br />STAIRS. REFER TO PLAN DETAILS <br />1171'1M MOO: AAIM MI IAI IAIC/'%MRAATIrIAI <br />3/4" RISER CUT TO FIT <br />MAINTAIN BETWEEN 1/4" <br />AND 1/2" GAP TOP AND <br />BOTTOM, GLUED AND <br />NAILED TO STRINGER <br />2x12 TREAD <br />GLUED AND <br />NAILED <br />2X4 PT NOTCHED INTO <br />STRINGER AND TAPCONED\ <br />INTO FLOOR WITH GLUE--' <br />AT STRINGER CONTACT <br />POINTS <br />E-� <br />2X4 SPF NOSING GLUED AND <br />NAILED MATCH NOSING ON <br />OTHER TREADS <br />2X4 SYP BLOCKING <br />FOR STRAP (SIMPSON <br />` L`2x8 SYP DRYWALL STOP MUST <br />NOT TOUCH STRINGERS <br />2x4 BLOCK IN KNEEWALL FOR 2x12 NAILING <br />\ Lx4 GLUED AND NAILED TO STRINGER <br />FOR DRYWALL SPACING <br />H SECTION VIEW <br />SCALE: " = 1'-0" <br />JOIST <br />SYP <br />2x8 SYP <br />STRINGER MUST MAKE FULL / <br />CONTACT WITH LANDING <br />SIMPSON A35 OR / <br />LSC EACH <br />STRINGER <br />I <br />�A <br />ALIGN THIS STUD WITH <br />FACE OF 2ND RISER <br />--2x SYP CUT TO FIT I ' <br />BEARS IN WALL I <br />B <br />-------2x12 SYP <br />BEARS IN WALL I I <br />'--2x6 SYP / 1 <br />2x4 SYP BLOCKING <br />2x4 PT NOTCHED INTO STRINGER FOR STRAP <br />AND NAILED TO FLOOR WITH GLUE (SIMPSON MTS12 w/ <br />AT STRINGER CONTACT POINTS \ NAILS)d x 1 1/2" / <br />2x4 CUT ON BEVEL <br />DOES NOT BEAR IN <br />WALL GLUED TO <br />2x8 <br />F <br />—3/4" RISER CUT TO FIT <br />MAINTAIN BETWEEN" <br />AND J" GAP TOP AND <br />BOTTOM, GLUED AND <br />NAILED TO STRINGER <br />2x4 BEHIND RISER <br />BLOCKING FOR <br />—1x4 GLUED AND NAILED TO STRINGER STRAP GLUED TO <br />2x12 SYP SCAB 2x4 GLUED AND NAILED (EACH <br />STRINGER SIDE) TO BOTTOM EDGE OF 2x12 <br />STRINGER <br />2x4 DRAFT RISER AND TREAD <br />STOPZ77 <br />// <br />,,r2x8 SYP DRYWALL STOP NOT TOUCH SMUST <br />STRINGERS / <br />�I <br />.---�-2x4 BLOCKING FOR 2x12 <br />2x4 PT UNDER 2x12 ' <br />1 ROVIDE MOISTURE <br />\ PROTECTION <br />LZAA ALL COMPONENTS <br />/ IR TO CONC. Wl 4" X / <br />CONS @ MAX. 32" O.C. <br />'---ATTACH ALL COMPONENTS 1x4 GLUED AND <br />OF STAIR TO CONC. W/T" X \ NAILED TO STRINGER <br />2" TAPCONS @ MAX. 32" O.C. \ / <br />SECTION VIEW "A" SECTION VIEW "B" <br />SCALE: 1" = 1'-0" SCALE: 1" = 1'-0" <br />2x8 STRINGER MUST MAKE ALIGN THIS STUD WITH FACE OF 2nd RISER <br />SYP FULL CONTACT WITH LANDING � ^ -- -� <br />/ \ <br />__�D <br />G.1 <br />TOP OF \ <br />STRINGER <br />1x4 GLUED AND NAILED TO STRINGER <br />2x4 DRAFT <br />STOP <br />2x8 SYP DRYWALL STOP <br />MUST NOT TOUCH <br />/Z44Lta <br />2x SYP CUT TO FIT 1 STRINGERS <br />BEARS IN WALL <br />2x12 SYP BEARS <br />IN WALL I 2x4 BLOCKING FOR 2x12 \ <br />I SIMPSON A35 <br />2x4 PT UNDER 2x12 OR LSC EACH <br />SIMPSON A35 OR <br />LSC EACH <br />STRINGER�Zzz/z/ <br />2X4 CUT ON BEVEL <br />DOES NOT BEAR IN \ <br />WALL <br />1 2x6 SYP STRINGER <br />/ <br />\ 2x4 SYP BLOCKING OPTION: 2X4 CUT ON <br />FOR STRAP BEVEL GLUED AND <br />\ (SIMPSON MTS12 w/ NAILED TO SUPPORT <br />2x4 PT NOTCHED INTO STRINGER (14) 10d x 1 1/2" <br />AND NAILED TO FLOOR WITH GLU NAILS) W/ SIMPSON H3 — <br />/ AT STRINGER CONTACT POINTS \ <br />SECTION VIEW "D" <br />FILLER STRIPS ADDED <br />GLUED & SCREWED TO <br />PLYWOOD DECKING <br />SCALE: 1" = 1'-0" <br />PLYWOOD <br />2x SYP CUT TO FIT <br />BEARS IN WALL <br />--2x12 SYP <br />BEARS IN WALL <br />BULLNOSE DETAIL <br />SCALE: 1" = 1'-0" <br />2x4 GLUED <br />AND NAILED <br />SECTION D-D <br />-3/4 PLYWOOD <br />ON DECK <br />—2x8 SYP GLUED <br />AND NAILED TO <br />FRAMING <br />2x4 DRAFT 2x12 <br />STOP TREAD <br />GLUED <br />AND <br />2X4 PT NOTCHED INTO <br />STRINGER AND TAPCONED\ <br />INTO FLOOR WITH GLUE — <br />AT STRINGER CONTACT <br />POINTS <br />SCALE: 1" = 1'-0" <br />f2x8 SYP DRYWALL STOP MUST <br />NOT TOUCH STRINGERS <br />LX4/GLUED AND NAILED TO STRINGER <br />AeOR DRYWALL SPACING <br />H <br />SECTION VIEW "E" <br />SCALE: 1" = V-0" <br />—� NOTE: 2x8 l <br />\ DRYWALL STOP <br />\ NOT SHOWN <br />E SECTION VIEW <br />- STAIR CONSTRUCTION DETAILS <br />SCALE: " =1'-0" (IF 11X17 REDUCE SCALE .5) SCALE: AS NOTED <br />SECTION VIEW "C" <br />SCALE: 1" = T-0" <br />FLOOR TRUSS OR CONN. TO BOTTOM NEWEL POST LET INTO <br />GIRDER, FIELD VERIFY OF NEWEL POST THE BLOCK <br />PER CONTRACTOR <br />PROVIDE <br />\ / I BLOCKING <br />2X8 BLOCKING <br />FOR NEWEL POST <br />TO ANCHOR TO. <br />(2) LAYER" EDGE GOLD PROVIDE SOLID BLOCKING (GLUED AND NAILED) <br />OSB OR PLYWOOD BELOW ALL NEWEL POST <br />"X16" LVL FROM JOIST TO JOIST. USE <br />OR 1 <br />ATTACHED W/ 12d NAILS 2 X 12 BLOCKS, GLUED AND FLOOR <br />@ 6" O.C. TOP, BOTTOM NAILED TO JOIST. TRUSSES <br />AND VERT. <br />NEWEL POST <br />SECTION VIEW "G" <br />SCALE: 1" = T-0" <br />BLOCKING <br />F SECTION VIEW <br />SCALE:" =1'-0" <br />SCALE: 1" = 1'-0" <br />JOINT <br />-TO <br />)ISTS) <br />NAILED AND <br />TOP PLATE <br />NTO RIM BAND, <br />ID NAILED TO <br />WALL BELOW <br />JOINT <br />-TO <br />)ISTS) <br />H <br />2X STRINAR <br />2X BLLOCKING <br />PSON MTS12 w/ <br />10d x 1 1/2"AILS <br />\D OR N2X BLOCKING <br />3 / <br />RISC / <br />VARIE <br />ECTION VIEW "H" <br />SCALE: 1" = 1'-0" <br />C" <br />N <br />O <br />? o <br />o <br />= m w C-4 <br />►°O'er <br />U- o.. <br />M o .- <br />N 'O <br />O <O <br />Q N N <br />d d <br />> <br />a> o -Ci <br />cG w g cc <br />C ° d <br />�dM <br />'Qa <br />� o <br />o. w <br />w <br />:-) 1r� $ F chr <br />fW <br />ESSIO <br />� <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />E � NN <br />Q `o <br />I-N N 0 N� <br />0 � _ 8 � ik <br />(a <br />ILM <br />m <br />0 <br />Wu-ii a <br />z <br />Z @ �Y, O = <br />0w� r m9 o 0 <br />1i 5 N G m J Q <br />°' °' z <br />W Go <br />Z U)I z <br />OU ❑❑❑ <br />Z <br />W <br />Z ,QN, n <br />Z <br />z <br />¢ v <br />J <br />Q_ lA <br />N <br />- <br />z 49 <br />QX <br />L .s <br />a <br />to <br />U <br />_ <br />OW <br />�( <br />U � <br />W J <br />r— E <br />z� <br />c <br />�Q <br />o <br />V> <br />M <br />y <br />Z <br />z <br />M <br />N E <br />a 0 <br />E u <br />O � <br />- 0s K <br />w� <br />= <br />)Z <br />Q n <br />z® <br />os <br />its <br />O E <br />o <br />�< <br />a <br />�o <br />01 <br />z <br />d � <br />�p <br />0 <br />K Z <br />�w <br />1 <br />C <br />¢❑ <br />a <br />9x <br />m0 <br />�Z. <br />z <br />m J <br />tim <br />a� <br />z <br />aw <br />8 3 <br />0 <br />zz <br />5° <br />Waz <br />T <br />W. <br />M <br />v <br />w� <br />05 <br />�O <br />3 <br />N O <br />�L <br />hi <br />rn <br />m <br />n7 <br />L <br />O <br />Co to <br />T <br />0' ca <br />T <br />�: <br />to <br />l.() <br />OCO <br />� <br />N <br />0) <br />CO <br />M Q4 <br />L.() <br />r <br />cM N <br />r <br />m <br />W <br />CO � <br />cM CM <br />7 O W LO <br />o <br />Z <br />E T— to <br />- <br />cc <br />c <br />c <br />a <br />ai <br />U Q p <br />JOB <br />NO: 23-06104 <br />SCALE: AS NOTED <br />SHEET NO. <br />ST <br />