Laserfiche WebLink
42" KNEE WALL WITH <br />36" CAP &CASING OR <br />36" RAILING <br />3/4" PLYWOOD <br />DECKING <br />16_ - <br />- ---15 <br />- --.14_ <br />- 3 - -- - - - <br />13 <br />- - PRE-ENG FLOOR <br />_ 121I TRUSS <br />10 a lx TREAD (TYP.) -� <br />3/4" PLYWOOD <br />_- 9 1 <br />DECKING <br />2x6 LANDING--,- <br />8'-� 1 <br />- 7 1 1x RISERS (TYP.) - <br />2x4 FRAMING <br />-_- 6 1 r; <br />5 42" KNEE WALL WITH F- <br />4 1x8 CAP & CASING OR <br />3 36" RAILING <br />2 2x4 THRUST <br />i BLOCK <br />7r, <br />ON HANDRAIL <br />36" H. CONT. RETURN T O <br />GRASPABLE <br />RAILING <br />*WALL DETAIL. <br />�r <br />- - - -- -- - SCALE: NTS <br />6'-7" <br />2x4 THRUST _ <br />BLOCK � <br />60 <br />(3) 2x12 <br />STRINGERS 1 <br />3/4" PLYWOOD D2 H1 (D <br />DECKING TYP. @ 6 <br />2x6 LANDING i0 CORNERS (2) 25-SH D2 <br />2x4 FRAMING EGRESS <br />TYP. STAIR SECTION <br />STAIR CALCULATIONS: SCALE: 1/4" = 1'-0" <br />TOTAL RISE = 1 U-0 3/4" <br />(16) RISERS AT 7 -9/16" <br />10" TREADS wl 3/4" NOSING <br />Stairway construction shall conform to the FBC Residential 6th Edition (2017) sections R311.7, R312 and R302.7. <br />Riser height: <br />The riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading edges of the <br />adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Tread depth: <br />The tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the vertical planes of <br />the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The greatest tread depth within any <br />flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Winders: <br />Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the foremost <br />projection of adjacent treads at the intersections with the walkline. Winder treads shall have a tread depth of not less than 6 <br />inches at any point within the clear width of the stair. <br />Nosings: <br />The radius of curvature at the nosing shall be not greater than 9/16 inch. A nosing projection not less than 3/4 inch and not <br />more than 11/4 inches shall be provided on stairways with solid risers. The greatest nosing projection shall not exceed the <br />smallest nosing projection by more than 3/8 inch between two stories, including the nosing at the level of floors and landings. <br />Beveling of nosings shall not exceed 1/2 inch. <br />Handrails: <br />Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more risers. Handrail <br />height measured vertically from the sloped plane adjoining the tread nosing, or finish surface of ramp slope, shall be not less <br />than 34 inches and not more than 38 inches. Handrails for stairways shall be continuous for the full length of the flight, from a <br />point directly above the top riser of the flight to a point directly above the lowest riser of the flight. Handrail ends shall be <br />returned or shall terminate in newel posts or safety terminals. Handrails adjacent to a wall shall have a space of not less than <br />11/2 inches between the wall and the handrails. <br />Grip -size: <br />Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater than 2 inches <br />or provide equivalent grasp -ability in compliance with Section R311.7.8.3. <br />Guards: <br />Guards shall be located along open -sided walking surfaces, including stairs, ramps and landings, that are located more than 30 <br />inches measured vertically to the floor or grade below at any point within 24 inches horizontally to the edge of the open side. <br />equired guards at open -sided walking surfaces, including stairs, porches, balconies or landings, shall be not less than 36 <br />inches in height as measured vertically above the adjacent walking surface or the line connecting the leading edges of the <br />reads. Required guards shall not have openings from the walking surface to the required guard height that allow passage of a <br />sphere 4 inches in diameter. <br />nder-stair protection: <br />nclosed accessible space under stairs shall have walls, under -stair surface and any soffits protected on the enclosed side <br />ith 1/2-inch gypsum board. <br />L SEE PLAN FOR LANDING DEPTH <br />MIN. (3) 2x STUDS R <br />@ END OF LANDINC <br />BELOW HDR. BEAM <br />STANDARD (3) 2x1; <br />STRINGERS w/ <br />SIMPSON A35/USP <br />MP34 CLIP TO <br />FLOOR SYSTEM 01 <br />LANDING FRAMINC <br />(2) 2x HDR. <br />REQ'D @ ENE <br />LANDING FOF <br />STRINGERS l <br />CONNECT TC <br />PLY SHEATHING OVER <br />LANDING ATTACHED PER <br />GENERAL FLOOR <br />CONSTRUCTION NOTES <br />2x8 #2 SYP JOISTS @ LANDING <br />@ 16"O.C. w/ SIMPSON A35/USP <br />MP34 OR LUS26 HANGER ON <br />EA. SIDE <br />MASONRY OR WOOD WALL, <br />SEE PLAN <br />2x8 #2 SYP (P.T. IF MASONRY <br />WALL) CONTINUOUS LEDGER <br />w/ (3) 16d NAILS @ 16" O.C. MAX. <br />TO EA. STUD. ((2) 1/4"X3 1/2" <br />TITENS @ 16" O.C. MAX. FOR <br />MASONRY WALL) <br />GENERAL LANDING FRAMING INFO. <br />SCALE: N.T.S. 9'-0" MAX LANDING LENGTH <br />3 <br />D2 <br />Sim. w/(1) <br />MSTAM36 <br />@ BASE <br />CO <br />1 <br />L1 <br />3 <br />D2 <br />SIM, w/ (1) <br />MSTAM36 <br />@ BASE <br />3 <br />D2 <br />SIM. w/ (1) <br />MSTAM36 <br />@ BASE <br />25' <br />O(D <br />�� @ 2x4 #2 SPF STUDS @ 16" <br />O.C. TYP. 2nd FLOOR <br />Oco <br />_ _ f /� <br />2468 - O. BA H k <br />° <br />8 0' FLAT C G <br />G.T. o R/SH <br />N - 48x42 <br />- - - RECE <br />7­177-- <br />TR ;t <br />I <br />TILE TC <br />�"-� <br />- <br />- - <br />OWNER'S <br />36"x22" <br />ATTIC IC <br />h <br />SUITE <br />io <br />ACCESS g'_0" FL T CLG <br />I� N <br />-- _ <br />CAR T <br />- c� <br />8'-0" FLAT CLG <br />2468 <br />I <br />TP <br />CARPET <br />- - - <br />L- <br />4068 <br />B.F. <br />------------ <br />R/SH <br />■NTAIWSI <br />.+ `I4'-81 4" <br />BEDROOM 2 <br />8'-1 FLAT CLG <br />CARPET <br />16 <br />42" H 1/2 WALL <br />5068 <br />OR RAILING PER <br />SPECS <br />B. F. <br />15 <br />14 <br />13 <br />N <br />--------------- <br />r2668 <br />R/SH <br />12 <br />j <br />I TECH 60 <br />o <br />11 <br />I CENTER <br />- <br />'�0) <br />10 <br />3'-3" 5'-8" <br />5 7" in <br />g <br />8 <br />co <br />`'I' <br />� r <br />ti6� H <br />+_, $ 0'FLATCL <br />TILE TO <br />TA. F.F. <br />7 <br />L - --- <br />� 2868 _T�LT_ <br />6 <br />Qo <br />M N <br />00 <br />C° <br />4-SH �/ <br />BEDROOM 3 <br />N <br />8'-0" FLAT CLG <br />G.T. <br />-- - - - - -- <br />- <br />- <br />I <br />-- - <br />CARPET <br />- -- --- <br />11'-2" <br />2'-4' <br />i-'- <br />I <br />1 V-6" <br />----- G.T. <br />- <br />- <br />0o <br />T�U, <br />r <br />BEDROOM 4 <br />8'-0" FLAT CLG <br />1 <br />c7 <br />CARPET <br />I <br />0 <br />I <br />=I <br />�I <br />�� <br />m <br />1/2 33 SH <br />I <br />H1 B <br />25-SH 25-SH 9 <br />�GRESS 42 22 EGRESS <br />D2 <br />HH D1 H1 O <br />2-11" 13'-6" Z-11" 2'-10" 2'-10" <br />An' A.. C+ O.. <br />25'-0" I <br />� I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I--------------------------------------J <br />TEMP. GL. <br />ENCL. ON 42" <br />HIGH KNWL. <br />3 <br />D2 <br />SIM. w/ (1) <br />MSTAM36 <br />@ BASE <br />fn <br />U) <br />Lu <br />6 <br />in 12� <br />(N w D2 0 <br />O H1 <br />"v <br />TYP. @ 2 <br />STORY. SEE <br />JJ/S6 FOR <br />STEM WALL <br />OPT. <br />3 <br />D2 <br />SIM. w/ (1) <br />MSTAM36 <br />@ BASE <br />SIM. w/ (1) <br />MSTAM36 <br />@ BASE <br />3 <br />D2 <br />REVISION NOTES 12/17/2009: <br />1. ALL CLOSETS THAT ARE NOT WALK-IN CLOSETS <br />ARE TO BE FRAMED DOWN TO 8'-0" A.F.F. <br />2. ALL BLOCK WALL FURRING IS TO BE 24" O.C. <br />EXCEPT IN WET AREAS. SPACE WET AREA <br />FURRING AT 16" O.C. <br />3. NO RECESSES FOR SHOWERS. SHOWERS ARE <br />TO BE PANNED WITH A PRE-FAB, BASE. <br />4. ALL VANITY HEIGHTS ARE 36" A.F.F. <br />5. SLIDING GLASS DOORS ARE TO HAVE A 1-1/2" <br />RECESS. REFER TO MASON'S SCOPE FOR <br />RECESS WIDTH. <br />6. ALL BATHROOMS HAVE ONE MEDICINE CABINET <br />7. ALL 50' PLANS. FRAME BAR TOP AT 40-1/2" A.F.F. <br />8. ALL TUB DECKS ARE SIZED AS FOLLOWS; <br />40' PRODUCT LINE - MIN. 48" x 64" <br />50' PRODUCT LINE - MIN. 48" x 76" <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) - 1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2950 <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2950 <br />(2) - 2X4 #2 SYP W/ 1/2" <br />Follow Q/S4. See Plan for <br />RAG <br />FLITCH PLATE <br />Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE "C" <br />�A <br />+29.7 / -32.2 <br />© <br />+29.7 / -39.7 <br />© <br />+28.3 / -30.8 <br />CD <br />+28.3 / -37.0 <br />OE <br />+26.6 / -29.1 <br />OF <br />+26.6 / -33.5 <br />Q <br />SEE SN SHEET SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />+29.7 / -39.7 <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20 X 26 <br />181 X 251 <br />S.H. <br />13 <br />20 X 38 g <br />18' X 37 3 <br />S.H. <br />14 <br />20X505 <br />181X50 <br />S.H. <br />15 <br />20X63 <br />182X622 <br />S.H. <br />16 <br />20X72 <br />182X711 <br />S.H. <br />11-12 <br />271/4X26 <br />26X252 <br />S.H. <br />1H3 <br />271/4X383 <br />26x373 <br />S.H. <br />1H4 <br />274X50' <br />26x50 <br />S.H. <br />1H5 <br />274X63 <br />26X621/2 <br />S.H. <br />1H6 <br />274X72 <br />26X711/2 <br />S.H. <br />22 <br />37 d X 26 <br />36 z X 25 1/2 <br />S. H. <br />23 <br />37 4 X 38 s <br />3612 X 37 314 <br />S.H. <br />24 <br />37 J X 50 a <br />36 � X 50 <br />S.H. <br />25 <br />37 3 X 63 <br />36 ' X 62 1/2 <br />S. H. <br />26 <br />37 d X 72 <br />36 z X 71 1/2 <br />S.H.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 � WIDE <br />S.H. <br />32 <br />54 X 26 <br />5212 X 25 2 <br />S. H. <br />33 <br />54 X 38 g <br />52 1 X 37 a <br />S.H. <br />34 <br />54 X 50 a <br />52 1X 50 <br />S.H. <br />35 <br />54 X 63 <br />521 X 621 <br />S.H. <br />36 <br />54 X 72 <br />52 z X 71 2 <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />SECOND FLOOR PLAN - ELEV-B <br />SCALE: X"=V-0" <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic , crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above flr. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />MASONRY HGT. @ 8'-0" A.F.F. <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO <br />UPLIFT CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />FIRST FLOOR LIVING AREA 952 S.F. <br />SECOND FLOOR LIVING AREA 1121 S.F. <br />TOTAL LIVING AREA 2073 S.F. <br />GARAGE 396 S.F. <br />LANAI 104 S.F. <br />ENTRY 32 S.F. <br />TOTAL SQ. FT. 2605 S.F. <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 R-19 KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION jR-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />N <br />o <br />cue <br />CW <br />CD <br />ti a� M <br />cs ca N <br />a m � <br />.. c u- ra-. <br />� C%; <br />cn ®go <br />d <br />CU <br />co � <br />E <br />CD <br />� U <br />,. <br />at4 i`„rsnpg. <br />J <br />1 : fl. <br />LO <br />F <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions <br />of the drawing pages bearing <br />Engineer's signature and seal. <br />r. <br />Wt�,., <br />F <br />Co E <br />P + <br />s <br />O M O <br />.a <br />0 <br />p NV o <br />+�+ _ W Q N_ W <br />rn N <br />CD IJi <br />w up <br />ILL wa <br />+ Z <br />s m a <br />0 z <br />W <br />o 0 g N o <br />Ile <br />W <br />Z <br />m <br />0 <br />L0 N Z Q <br />CO <br />J <br />N O o <br />a z <br />U ¢ <br />0 C4 <br />�) W <br />❑❑ <br />V M � <br />z N M <br />o <br />z <br />zoo <br />Jc :2:,N <br />cif <br />' <br />M <br />z <br />/1 C <br />W <br />\J O <br />+-1 <br />- <br />O <br />N <br />w o <br />�N <br />U <br />~ - E <br />�I <br />U O <br />N <br />m <br />o <br />� <br />J� <br />w <br />E� <br />F@ r6 <br />0 o <br />a E <br />co <br />�< <br />a O <br />g, <br />Z <br />.= <br /><o <br />o <br />1 J <br />lJJr aa <br />c <br />o <br />< <br />m 0 <br />of <br />a C <br />N <br />O 6 <br />"m <br />Z F <br />m <br />az <br />� <br />¢ <br />ap <br />ZZ <br />Z <br />go <br />NOR <br />in <br />A > <br />7 <br />< 0 <br />a <br />y W <br />2 k <br />O <br />w r <br />O <br />zl< <br />o 3 <br />.N Ip <br />J <br />>M <br />0 <br />Ca <br />c� <br />N <br />d' <br />T <br />Q <br />^ <br />U <br />o <br />N <br />m <br />_ <br />LO <br />co <br />Cn <br />-� <br />n CD <br />LO <br />W <br />E <br />N <br />M <br />o <br />Z <br />� V <br />iri Ln <br />Z <br />E r <br />U) <br />CU <br />@ <br />a <br />E <br />U <br />Q p <br />c <br />JOB <br />NO: <br />23-06112 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />1.2 <br />