Laserfiche WebLink
*DIAGONAL SPACED <br />AT 15'-0" O.C. MAX <br />CONTINUOUS LATERAL <br />BRACING- NAIL OVER <br />X-BRACE AS SHOWN - <br />INSTALL BLKG. AT TRUSS <br />WEBS FOR NAILING -- <br />SEE ROOF <br />PLAN SHEATHING <br />---BLOCKING <br />2X4 BLOCKING <br />BETWEEN TRUSSES <br />SECT. A -A <br />X-BRACING - 2x4 SPF OR <br />SYP w/ 2-16d @ EACH TRUSS <br />WEB <br />CROSS BRACING DETAIL (TYP.) <br />SCALE: 1/2" = V-0" <br />G.T. <br />ADD 2X4 ALONGSIDE <br />TOP CHORD WHEN REQ'D <br />TO PREVENT PLYWOOD <br />SPAN FROM EXCEEDING <br />MAX 24" SPAN (EITHER <br />SIDE OR BOTH IF REQ'D) <br />PROVIDE 2X4 MIN. BLOCKING AT <br />OF HIP/RIDGE, TYP.BETWEEN <br />TRUSSES W/ (2) 12D NAILS EACH <br />END TO TRUSS TOP CHORD <br />TYP. <br />�A TRUSS <br />SSES <br />(2) 12D NAILS —� <br />AT 12" O.C. MAX <br />HIP/RIDGE BLOCKING DETAIL <br />TRUSS <br />NOTES. <br />TYP. HAND FRAMING ABOVE TRUSS <br />FRAMED RIDGE 2X4 STUDS & PLATES AT <br />CON1. <br />WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TP1-2014 <br />MAY B <br />MAY BE NAILED EACH DIRECTION TYP. U.N.O. <br />U.N.O. <br />(TRUSS PLATE INSTITUTE NOTE THAT THE COMBINED WIND AREA IS GREATER <br />) <br />w/ MIN. (4) 12d WHEN <br />BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE <br />IT LANDS NEXT TO <br />INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST <br />PRE-ENG. TRUSS 2x8 BLKING. NAILED @ EACH <br />COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES <br />OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD <br />SIDE w/ (3) 12d NAILS REQUIRED w! (2) NAILSWH <br />WHEN <br />WHN HTS20 <br />SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & <br />W/ (14) - 10d X 1 1/2" EACH <br />SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION <br />OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED <br />ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER <br />A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. <br />at <br />2. <br />ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS <br />LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTURER ALL LATERAL BRACING <br />SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'-0" <br />O.C. MAXIMUM. <br />3. <br />ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED W/ 2-16D <br />NAILS AT EACH TRUSS INTERSECTION. <br />Cg <br />4. <br />ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS <br />DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT <br />TB <br />ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. <br />pg <br />g <br />5. <br />PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS <br />DEPTH EXCEEDS STANDARD HEEL HEIGHT. SEE TYP. TRUSS BLOCKING DETAILS <br />PRE-ENG. TRUSS <br />2X4 BLOCKING <br />2X4 DIAGONAL AT 8'-0" O.C. BETWEEN EA. TRUSS <br />CONT. ROOF SHEATHING AT TRUSS TOP <br />MAX &EACH END ALTERNATE <br />DIRECTION TYP. -� <br />A <br />CHORD AT ALL HAND FRAMED AREAS TYP. <br />SCALE: 1 /2"= V-0" <br />HIP <br />G.T <br />VERTICAL SCAB <br />2 x 6 #2 SPF 48" D.C. <br />W/ (4) 10d TOP & <br />BOTTOM OR SIMPSON H2.5A <br />W/ (10) 8d NAILS <br />COLLAR TIE <br />EVERY 3rd <br />RAFTER <br />2x4 SPF 2 <br />(2) #7X 3-1/2" WOOD <br />SCREW EACH TRUSS <br />OR SIMPSON H2.5A @ 48" O.C. <br />BEVEL CUTS <br />(OPTIONAL) <br />DIAGONAL 2x8 #2 SPF RIDGE BEAM <br />AT 8'-0" WOOD <br />MAX TRUSS iC -jt 2x6 #2 SYP RAFTERS FOR SPANS 4FT <br />TO 8FT 2X4 RAFTERS FOR SPANS LESS <br />THAN 4FT @ 2'-0"O.C. MAX. w/ (3) 10d <br />COMMON TOENAILS TO RIDE BEAM <br />2X4 CONT. AT--/ — CONC. MASONRY <br />T & B CHORD STEEL OR WOOD <br />BEARING SUPPORT <br />A -A ALTERNATE BLOCKING <br />DETAIL a� INTERIOR BEARING 3 <br />WOOD TRUSS SCALE: 1/2" = 1'-0" <br />A PROVIDE BLOCKING AT ALL TRUSS BEARING <br />SUPPORT WHERE TRUSS DEPTH EXCEEDS <br />STANDARD HEEL HEIGHT <br />TYP. WOOD TRUSS BLOCKING DETAIL <br />SCALE: 1 /2"=V-0" <br />2 x P.T. BLOCKING BY FRAMER FOR <br />_ <br />PLYWOOD EDGE NAILING w/ (2) 1/4"x3" TITEN2 <br />PROVIDE 25" LAP <br />(2) SIMPSON SDWC15600 SCREWS @ <br />EACH TRUSS TO LEDGER <br />- <br />SPLICE @ F.C. REBAR <br />1/2" GYP. WB <br />OR 3/8" PLYWOOD/ TYPE 2-M-W <br />OSB (DRAFTSTOPPING) TO BE NAILED W/8d <br />TOP -CHORD BEARING <br />COMMON @ 6" O/C TO ONE SIDE OF THE <br />FLOOR TRUSSES @ <br />FLOOR TRUSS FOR AN <br />24" O.C. <br />AREA 5 1000 SQ. FT. OF <br />FLOOR AREA & SEALED <br />PENETRATION AREA W/ <br />FOAM. DRAFTSTOPPING <br />SHALL DIVIDE THE - <br />CONCEALED SPACE INTO _..___._ <br />APPROX. EQUAL AREAS. <br />- <br />2) 2x8 SYP #2 P.T. <br />LEDGER ATTACHED TO <br />MASONRY w/ (2) ROWS <br />5/8" SIMPSON TITEN HD, <br />MIN. 5" EMBEDMENT @ <br />24" O.C. STAGGERED @ <br />- <br />_ <br />= <br />12" O.C. <br />DOUBLE KNOCK -OUT <br />BLOCK w/ (1) #5 CONT. <br />IN EACH COURSE. <br />FLOOR CONNECTION @EXTERIOR WALL <br />SCALE: 3/4" = V-0" <br />LAP SPLICE <br />1'-0" 6" 6" 1'-00, 6" 6" 1'-0" <br />TYP. TYP. <br />o O I O o O o <br />I SPLICE <br />o O I O o o O <br />Z_p� SPLICE BEYOND Z_p" <br />PART. ELEV. VIEW <br />1 all n <br />0 <br />DBL. KO. BLOCK MIN. <br />0 <br />MIN. TYP. <br />F <br />I <br />24"MIN. <br />(2) 2x8 P.T. <br />ATTACHED <br />(2) 2x8 SYP #2 P.T. CONT. <br />LEDGER w/ (2) ROWS OF 5/8" <br />TITEN HD STAGGERED @ 24" <br />O.C. w/ 5" EMBEDMENT & 6" <br />EACH SIDE OF SPLICE & <br />EACH END. <br />LEDGER <br />LAP SPLICE TOGETHER w/ <br />PART. PLAN VIEW (2) ROWS OF 10d @ 6" D.C. <br />LEDGER SPLICE DETAIL 54 <br />SCALE: 3/4" = V-0" <br />PROVIDE 30" LAP SPLICE <br />@ F.C. REBAR. <br />(2) ROWS OF 10d NAILS @ 4" O.C. <br />ore <br />':-. <br />FLOOR TRUSSES <br />@ 24" O.C. <br />Ic'SI <br />DOUBLE KNOCK -OUT <br />BLOCK W/ (1) #5 ALTERNATE: <br />CONT. IN EACH = (2)2x8 SYP #2 P.T. <br />COURSE LEDGER ATTACHED TO MASONRY W/ <br />(2) 5/8" DIA. TITEN HD MIN. 5" <br />EMBEDMENT PER 54/D1 SPACING <br />SIMPSON HGAM10 @ <br />4'-0" O.C. T & B <br />FLOOR ATTACHMENT 50 <br />SCALE: 3/4" = V-0" <br />WOOD TRUSS <br />DETAIL - ADJACENT TO TRUSSES <br />OPTIONAL 6" WIDE BOARD <br />BATTEN STRIPS TO <br />ELIMINATE 3/4" AIR SPACE. <br />SEE MANUFACT. SPECS. <br />FOR INSTALLATION. —� <br />PRE-ENGINEERED ROOF —� <br />TRUSSES AT 24" O.C. MAX <br />(2) LAYERS 1"X24" PROPRIETARY TYPE <br />"X" GYP. PANELS INSERTED BETWEEN <br />2" FLOOR & CLG. RUNNERS W/ 2" <br />STEEL H STUDS BETWEEN ADJACENT <br />PAIRS OF GYP. PANELS. <br />2" FLOOR RUNNER <br />W/ 3/16" DIA. x 1 3/4" <br />TITEN2 @ 16" O.C. <br />FIRE CAULK <br />RUNNER TO BLOCK <br />WALL EACH SIDE <br />NOTES: <br />1. SEPARATION WALL IN THE <br />ROOF SYSTEM PROVIDES <br />2-HRS. PROTECTION PER <br />GA FILE ASW 1002. <br />6" WIDE 1/2" DENSARMOR PLUS FIREGUARD-C OR <br />TOUGHROCK FIREGUARD-C GYPSUM BOARD <br />MASO <br />SEE P <br />GA FILE ASW 0810 SCALE: 3/4"=V-0" <br />/7\ In.d T/1CKIAILS <br />2X6 P.T. CONT. <br />LEDGER T&B W/ (2) <br />1/4" X 3" TITEN2 @ 24" <br />O.C. T&B <br />TRUSS <br />(6) .162" x 3 1/2" NAILS <br />TRUSS TO LEDGER & <br />(4) .148" x 1 1/2" <br />LEDGER DETAIL <br />SCALE: 3/4" = V-0" <br />MASONRY WA <br />SEE FLO( <br />PLAN FOR MOI <br />INF <br />STRUCTURAL SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />VARIES W/ <br />ROOF SLOPE <br />IN. 2x4 #2 SPF P.T. <br />ONT. W/ (2) J"x3" <br />ITEN2 SCREWS @ <br />ill O.C. <br />TRUSS OR <br />ROOF SYSTEM <br />SHEAR TRANSFER <br />EXTERIOR. WALL r5_2"*� <br />SCALE: 3/4" = V-0" <br />PROVIDE 2x BLOCKING W/ (2) 12d NAILS EA. END BETWEEN <br />TRUSSES 4'-0" FROM SEPARATION WALL. SOLID BLOCKING <br />12 BETWEEN TRUSSES TO BOTTOM SIDE OF PLYWOOD. BLOCK <br />SEE MUST BE "PITCH CUT" (SEE ELEVATIONS) TO PROVIDE AS <br />NO MINIMUM AIR SPACE <br />W/ BATTEN STRIPS <br />ELEV. MUCH CONTACT AS POSSIBLE TO UNDER SIDE OF ROOF <br />DECK. ALL JOINTS AROUND BLOCKING MUST BE CAULKED <br />1" DENSGLASS ULTRA <br />�' WITH APPROVED FIRE CAULKING. <br />SHAFT LINER <br />2X4 BLOCKING @ 48" O.C. MAX. W/ <br />0 LB FELT (SHINGLES) <br />(2) 16d TOE NAILS @ EACH END <br />FIRE RESISTANT OSB 7116" <br />2" CLG. RUNNER FIRE CAULK <br />SHEATHING 4' ON EA. SIDE <br />RUNNER TO SHEATHING <br />ABOVE AT EACH SIDE <br />OF WALL NOT STAGGERED <br />OVER PARTY WALL <br />CEILING BOARD <br />2x4 LEDGER @ 48" O.C. <br />MAX VERTICALLY NAILED <br />SEE ROOF PLAN <br />FOR STRAP INFO. <br />-- <br />TO TRUSS WEBS W/ (2) 8d <br />BASE BOARD PER SPECS <br />STD 909 HOOK <br />2. MASONRY WALL PROVIDES (1) #5 VERT. IN FILL CELLS <br />2-HRS PROTECTION PER (SEE FILL CELL PLAN FOR <br />UL-U905 (see sht 9) LOCATIONS) <br />2 x P.T. BLOCKING BY FRAMER FOR PLYWOOD EDGE NAILING <br />W/ (2) 1/4"x3" TITEN2 <br />(2) SIMPSON SDWC15600 SCREWS @ EACH <br />TRUSS TO LEDGER <br />(2) 2x8 SYP #2 P.T. CONT. LEDGER w/ (2) ROWS OF 5/8" <br />TITEN HD STAGGERED @ 24" O.C. w/ 4" EMBEDMENT & 6" <br />EACH SIDE OF SPLICE AND EACH END SEE 54/D1 <br />3/4" PLYWOOD DECKING GLUED AND <br />NAILED W/ 8d COMMON AT 6" O.C. <br />EDGES AND 12" O.C. FIELD <br />1/2" GYP. WB. OR 3/8" PLYWOOD/TYP 2-M-W <br />OSB (DRAFTSTOPPING) TO BE NAILED W/ <br />8d COMMON AT 6" O.C. TO ONE SIDE OF , TOP CHORD SRG. <br />FLOOR TRUSS FOR AN AREA < 1000 S.F. rLOO /$YSTEM <br />AND SEALED PENETRATION AREAS W/ <br />FOAM. DRAFTSTOPPING SHALL DIVIDE <br />THE CONCEALED SPACE INTO APPROX. <br />EQUALAREAS <br />(1) LAYER 1/2" HIGH STRENGTH OR 5/8" GYP. <br />(OR 5/8" GYP. TYPE "X" @ GARAGE W/ A <br />HABITABLE ROOM ABOVE) W/ 1 3/8" <br />DRYWALL NAILS OR DRYWALL SCREWS 7" <br />O.C. CEILING, 8" O.C. WALLS & 4" O.C. <br />EDGES <br />(1) #5 VERT. IN FILL CELLS (SEE <br />FOUNDATION PLAN FOR LOCATIONS) <br />8" CONC. BLOCK (TYP.) PER UL905 — <br />1x P.T. BASE NAILER <br />6x6 W1.4xW1.4 WWF. --� <br />(TYP.) <br />EXTEND BURN CLIPS AS PER 2 x P.T. BLOCKING BY FRAMER <br />FIRE WALL MFG. FOR PLYWOOD EDGE NAILING <br />R30 INSUL. MIN. SPECIFICATIONS NAILED INTO �// (2) 1/4"x3" TITEN2 <br />2x4 LEDGER ONLY AT EACH <br />SIDE OF STEEL "H" STUD. <br />- (2) SIMPSON SDWC15600 <br />(1) LAYER 1/2" HIGH STRENGTH SCREWS @ EACH TRUSS TO <br />OR 5/8" GYP. WB. W/ 1 3/8" LEDGER <br />DRYWALL NAILS OR DRYWALL <br />SCREWS 7" O.C. EDGES. <br />SIMPSON RBC @ 36" O.C. W/(6) 10d X 1 1/2" NAILS 3/4" FLOOR <br />INTO TRUSS BOTTOM CHORD/SCAB & (3) 1/4" X 2-3/4" SHEATHING <br />TITEN SCREWS INTO MASONRY. NOTE: RBC CLIPS <br />TO BE INSTALLED PRIOR TO FURRING STRIPS <br />INSTALLATION (TYP. ON BOTH FACES OF WALL) <br />1x P.T. NAILER INSTALLED <br />_ AFTER INSTALLING RBC'S <br />1/2" GYP. WB OR 3/8" <br />_ <br />8"x8"x16" CONC. KNOCKOUT <br />PLYWOOD/ <br />— BLK. W/ 1 #5 ROD CONT. <br />TYPE 2-M-W OSB <br />FILLED W/ GROUT <br />(DRAFTSTOPPING) <br />4"x4" INSPECTION PORT AT <br />0 BE NAILED W/8d <br />_- <br />EACH FILLED CELL (TYP.) <br />COMMON @ 6" O/C TO <br />1x P.T. BASE NAILER <br />ONE SIDE OF THE <br />STD. 909 HOOK <br />FLOOR TRUSS FOR AN <br />(SEE DETAIL) <br />AREA 5 1000 SQ. FT. OF <br />NAIL FLOOR TRUSS TO LEDGER W/ <br />FLOOR AREA & SEALED <br />PENETRATION AREA W/ <br />4 10d TOENAILS (TYP.) EA. SIDE <br />FOAM. DRAFTSTOPPING <br />2) SIMPSON SDWC15600 SCREWS <br />SHALL DIVIDE THE <br />( @ <br />CONCEALED SPACE INTO <br />EACH TRUSS TO LEDGER <br />APPROX. EQUAL AREAS. <br />TOP CHORD BRG. <br />FLOd# SYSTEM, <br />PRE-ENGINEERE <br />FLOOR TRUSS' AT <br />— <br />24" O.C. <br />GYP. BOARD CLG. <br />DOUBLE KNOCKOUT BLOCK W/ (1) #5 ROD <br />CONT. IN EA. COURSE FILLED W/ GROUT <br />SEE 53/D1 FOR <br />LEDGER CONNECTIONS <br />1" P.T. NAILER <br />L—R-3 <br />MIN. INSUL. PER. FBC. <br />1/2" GYP. BD. <br />GYP. WB. <br />(2)-1 X 4 P.T. BASE <br />NAILER <br />— <br />BASE BOARD <br />TYP. "S" MORTAR (TYP.) <br />PER SPECS. <br />U_ <br />CONC. SLAB <br />-' <br />ga <br />. W <br />SEE FOUND. PLAN <br />N � <br />6 MIL VISQUEEN <br />NSPECTION PORT. AT <br />-�EACHIFILLED CELL (TYP.) <br />0 <br />• <br />(4) #5 C0NT. STD. 909 HOOK <br />ON 3" CHAIR 8" 2'_p" 8" (SEE DETAIL) <br />2-STORY PARTY WALL SECTION (PWO <br />SCALE: 3/4"=1'-0" <br />TREATED; <br />SEE PLAN <br />TOP OF PLATE <br />TOP COURSE W/ <br />LINTEL SEE <br />U <br />PLAN <br />= SEE PLAN <br />TOP OF WINDOW — <br />WINDOW PER PLAN <br />8" C.M.U. WALL <br />10'-8" <br />DOUBLE KNOCK -OUT <br />W/ (1) #5 CONT. IN. <br />EACH COURSE <br />REINFORCING W/ MATCHING <br />#5 DOWELS IN SOLID <br />GROUTED CELL W/ MIN. 25" <br />LAP SPLICE MIN. <br />�— 8" C.M.U. WALL <br />JP OF SLAB 0'-0" <br />F.F. <br />oo <br />VARIES WITH <br />N SITE GRADES <br />SEE PLAN <br />(V <br />3 #5 CONT. 20" <br />TYP. 2 STORY WALL SECTION <br />SCALE: 3/4" = V-0" <br />REV. 08.20.21 <br />N <br />-V- p <br />co e <br />3 W <br />, <br />J a CM <br />C r0 L7 N <br />—•z,mx <br />N M C L <br />y C <br />.q N Y <br />3 a,s a <br />d <br />m y W <br />J OJ <br />•- <br />= T <br />N (Z <br />c E <br />c0 p <br />6. J <br />tlllllllll <br />\\\ <br />�- <br />N <br />N <br />U �p *C cl . <br />:is FL4� <br />.... <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal Is only for <br />the structural <br />engineering portions of the drawing pages bearing <br />Engineer's <br />signature and seal. <br />E <br />Q g 8 <br />o <br />p ,e-M 93 <br />S <br />C3 4k li <br />M 2Sz <br />N V - <br />C�p J LL o. <br />J U S o. <br />_= 13lit <br />i' <br />=m=o rn a <br />� <br />W cc P o <br />o <br />W i�iM4'°i m <br />_ �Z a K <br />,^ N <br />Z Ov U o <br />W ❑ ❑ <br />z � <br />z o <br />Q v <br />2 <br />N <br />U) z <br />0 <br />v <br />�N LL <br />4-J U3 <br />U <br />OLLl O <br />ups <br />c <br />r <br />NV) <br />Cn <br />U d <br />c <br />w <br />U o <br />Q 0 <br />N <br />em <br />ti <br />Q <br />o <br />,. <br />Q <br />zu <br />E: <br />RS fp <br />i � <br />V o <br />g0& <br />Zo& <br />N ru <br />K O <br />w ? <br />Z <br />_j � <br />J <br />b <br />LL <br />�l <br />W <br />O <br />ild <br />a'� <br />U i <br />o O <br />NU <br />F- <br />o <br />C4 <br />Co <br />CV � <br />T <br />LO <br />c��l <br />T <br />CrCV CL <br />LO <br />60 <br />m U <br />N <br />00 <br />F _ <br />O <br />LO <br />t-- <br />n N <br />LO <br />00 o <br />rn <br />CD <br />O LO N <br />cD N <br />Ln <br />�— <br />m <br />M T_o <br />L6 iri N <br />Z <br />Z <br />E O <br />o' <br />a <br />E <br />U � 'a p <br />JOB <br />NO : 22-12493-12498 <br />SCALE : AS NOTED <br />SHEET NO. <br />D 1 <br />