Laserfiche WebLink
THESE DETAILS ARE GENERIC AND <br />MEANT TO SHOW GENERAL FLASHING <br />AND WATERPROOFING METHODS TO <br />BE USED. <br />318" CEMENT <br />PIASTER <br />12 MIL DRYL OK , <br />CMU - MASONRY BLOCK <br />EXTREME -- ---,\ <br />WINDOW <br />FASTENER -- <br />' 1) SEA1_At4T AT <br />4),EAL.AN I JOINT <br />WINDOW BUCK <br />OUTSIDE EDGE OF <br />' MASONRY <br />WINDOW BUCK <br />2) SEALANT JOIN <br />5) SEALANI f k IM <br />INSIDE EDGE C}F <br />,•i <br />WINDOW Ff;At 1!. <br />�` ' WINnnW BUCK <br />ACROSS WINDOW BUCK <br />/ <br />AND EXTEND TO <br />WINDOW FRAME'. <br />MASONRY- -�.__ _ <br />ATTACHED <br />PER COE <br />6) TOOLED SEALAN 1 <br />REOUIRDMENTS <br />BEAD BRIDGING <br />CLADDING AND WINDOW -' <br />rRAME <br />3) SEALANT WINDOW Fr' <br />WINDOW BUCK ALL T Hi <br />AJIUUND. INCLUDING GILL. <br />SCS 06_,05 CMU INSTALLATION 6 POINT BUCK AN <br />FENEST HATION INSTALLATION AND INTERFACE <br />JAMB, SILL AND HEAD DETAIL <br />APPROVED SHEATHING <br />APPROVED HOUSEWRAP <br />STRUCTALATH TWIN TRACK 2.5 <br />N4" CEMENT PLASTER <br />I? MIL (min) DRYLOK EXTREME <br />APPROVED FLASHING I APE <br />"V" SEALANT SOCKET WITH <br />TOOLED APPROVED SEAL ANT <br />WEATHER <br />7 RESISITIVE <br />t. BARRIER <br />'OLD UP WEATHER <br />!ESISTIVE BARRIER a �- �,VFATIIFR RESISTIVE <br />TEMPORARILY SECURE BARRIER <br />� 'NOOn FRAMTT CnNSTR �.,. <br />`-EXTERIOR :E_L,F-ADHERL;D FLASHINI; .; <br />SHEATHNNC:, 3Y LAPPING DOWN -- <br /><)VER RIM JOIS-1 AND Ill <br />'TALL BY 6 IN <br />� - WFATHFR / <br />RESISITIVE <br />BARRIER JtAL IUPbUt-JVIbIJ--.\ <br />UNDER DECKING <br />ADHERED FLASHING (SEE DETAIL WP07) , <br />:e <br />HEAD FLASHING TIE-IN INSTRUXTIONS: <br />1. Cut, fold up R temporarily secure weather <br />resistive bamer above header to allow for <br />flashing installation <br />Self -adhered flashing plus head flashing under <br />weather resistive barrier i <br />3 Fold weather resistive barrier back over head <br />flashing and seal with tape <br />SELF -ADHERED FLASHING Scale N <br />FLANGED WINDOW <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />ExII RIOR ; HI A11IIN' <br />REFER TO TECHNICAL <br />LETTER ON CHEMICAL <br />COMPATIBILITY <br />SELF -ADHERED FLASHING <br />NO FI-AQII OVER <br />T I UM NAILING <br />ANGE <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />SCS 06 02 WINDOW FIN INTFRFACF WITI I <br />FXTRI IDFD SI 1OI_ll DFR <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS <br />WATER RESISTIVE BARRIERS ARE REOUIRED BEHIND STUCCO <br />PER THE FBC RESIDENTIAL 7TH EDITION (2020) <br />Detail Instructions <br />Refer to the nurribei marked as #,J in each detail that corresponds to the <br />numbered items In the list of Instructions below: <br />1. Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water shedding <br />laps <br />3. Self -adhered flashing can be substituted for building paper <br />4 Split the release paper using the ripcord (Split release on demand, <br />embedded In the adhesive layer) - for ease of Installation and to <br />minimize scoring cuts <br />5. Hernove all release paper per standard installation instructions and <br />adhere to substrate using a square piece of flashing material (6" x 6" <br />Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to <br />fit tight to corner <br />R. Mechanically fasten as nPc Pssmy <br />NAILING FLANGE <br />SINGLE J) <br />% JOIST -.- <br />SELF -ADHERED <br />FLASHING <br />FLASHING <br />SELF -ADHERED FLASHING <br />DECK JOIST <br />SELI ADiIFRL0FLASl0i(. <br />U <br />2� <br />8 <br />V Y P 0 `-t <br />DOUBLE <br />JOIST <br />/ WOOD BEAM <br />E3FI OW <br />;j <br />SELF -ADHERED <br />FLASHING <br />2x FRAMEWALL <br />TILE FINISH <br />112" DUROCK <br />WP07 <br />1'4" PER PLAN <br />V-0" PER PLAN <br />SLOPE _ <br />8" CMU ------ - _ _ <br />4"OR8"CMU <br />(PER SEAT DEPTH) - <br />FILL WITH GROUT <br />---T ..4 <br />SLOPED MUD BEDS N . <br />VINYL SHOWER PAN <br />' °'. <br />SHOWER SEAT <br />WINDOW UNIT FLASHING REQUIREMENTS <br />-DOOR ROUGH OPE NIN1_, SLOPE <br />0 3 in : 12.0 in R703.1 General. Exterior walls shall provide the building with a weather -resistant exterior a°,all envelope. The exterior wall envelope shall <br />3a4"-1" BEAD of CONS (0.6 cm: 30.5 cm) Include flashing as described in Section R703.4. <br />ADHESIVE EAi -: -- SFL.F-ADHERED FLASHING <br />RErURN UrD CId rHrar.sl lc)L I:3 +^II <br />JAMB 6". 0,,! I R703.1-1 Water resistance The exterior wall envelope srlall be designed and constructed in a manner that prevents the accumulation of water <br />NAIL BRAND OR ECwAl- w;F ,• EX l"ERIOR within the wall assemblyb providing a water-resistant barrier behind the exterior cladding as required b Section R703.2 and a means of <br />PROOF CAULKING - -CE M I FIN- Y P g 9 q Y <br />BUILDING PAPER draining to the exterior water that penetrates the exterior cladding. <br />�:-Al I R F I ATIi R703.2 Water -resistive barrier. One layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D226 for Type 1 Telt or other <br />SUBFLOOR i approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls No 15 asphalt felt shall be applied horizontally <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A <br />d I k,! it , I )NSTR. <br />ADHLSIVE T1.1BE: APPLIEC <br />THRESHOLD OF DOOR At• <br />UP JAMB 6". USE LIQUID r <br />OR EQUAL WFAT'HEN. H:c <br />Sr CTION-A (SE E Df: T AIL WI'i <br />:iLLf -AUHE RLP Ft-AS4iING <br />SEAL TOPS OF JOISTS <br />UNDER DECKING <br />(SEE DETAIL. WP07) <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />SFLF ADHFR <br />SELF -ADHERED FLASHING <br />all 1 SIf )f (_:t �hNf I; <br />y <br />I Z <br />g_J <br />a <br />cr <br />W <br />Q <br />CL <br />F- <br />V) <br />w <br />0 <br />LU <br />W <br />UJ <br />a <br />WP11 <br />_77 <br />_ with the upper layer lapped over the lower layer not less than 2 inches. Where joints occur, felt shall be lapped not less than 6 inches. Other <br />ZL approved materials shall be installed in accordance with the water -resistive barrier manufacturer's installation instructions. The No. 15 asphalt <br />t felt or other approved water resistive barrier material shall be continuous to the top of walls and terminated at penetrations and building <br />appendages In a manner to meet the requirements of the exterior wall envelope as described in Section R703.1. <br />-- R703.7.3 Water -resistive barriers Water -resistive barriers shall be installed as required in Section R703.2 and, where applied over wood -based <br />Sheathing, shall include a water -resistive vapor -permeable barrier with a performance at least equivalent to two layers of Grade D paper. The <br />ndividual layers shall be installed independently such that each layer provides a separate continuous lane and an flashing Installed in <br />--^ - � Y P Y Y P P P Y 9 C <br />,_--•,_ __ -_ __ accordance with Section R703.4) intended to drain to the water -resistive barrier is directed between the layers. <br />/, SELF -ADHERED FLASHING , ,� `r-, <br />�; J !� EMT FINISH SILL; POTSHELF/ CHIMNEY SHOULDER VV r-" , Exception: Where the water -resistive barrier that is applied over wood -based sheathing has a water resistance <br />equal to or greater than that of 60-minute Grade D paper and is separated from the stucco by an intervening, <br />r� rI3-Rl�i . t substantially nonwater-absorbing layer or designed drainage space. <br />NEEDED IN CORNERS AI <br />LASHING <br />I ,I..I ,I�� `' hr�I°IIIII r AnFIE aIVE �703.4 Flashing. Approved metal flashing, vtn I flashing self -adhered membranes and mechanically attached flexible flashing shall be applied <br />THROUGH SELF -ADHERED LASIiINI, ,A��>I . g PP 9, Y 9 Y g PP <br />A; W-D ,I` , FLASHING SELF•ADHERED FLASHING -=,hingle-fashion or in accordance with the manufacturer's instructions. Metal flashing shall be corrosion resistant. Fluid -applied membranes <br />aNr,t uwlNc,,.r,. <br />EEDETAIL WPUt used as flashing shall be applied in accordance with the manufacturer's Instructions. All flashing shall be applied in a manner to prevent the <br />SCORED entry of water into the wall cavity or penetration of water to the building structural framing components. <br />W i RELEASE PAPER Self -adhered membranes used as flashing shall comply with AAMA 711. All exterior fenestration products shall be sealed at the juncture with <br />f-LF ,1.,,1! id I] f LASHING- '� I ($£FORE FOLDING •,� ��.,>: the building wall with a sealant complying with AAMA 800 or ASTM C920 Class 25 Grade NS or greater for proper joint expansion and <br />XTEND A RELEASE PAPER TO I -: <br />ADHESIVE ASSHCWN. contraction, ASTMC1281, AAMA 812, or other approved standard as appropriate for the type of sealant. Fluid -applied membranes used as <br />ERTICA^_ t F Pi rn <br />uTTara ;I flashing in exterior walls shall comply with AAMA 714. The flashing shall extend to the surface of the exterior wall finish. Approved flashings <br />RE''"`'' shall be installed at the following locations: <br />1. 1.Extenor window and door openings. Flashing at exterior window and door openings shall extend to the surface of the exterior wall <br />-� finish or to the water -resistive barrier ;omplying with Section 703.2 for subsequent drainage. Mechanically attached flexible flashings <br />shall comply with AAMA 712. Flashing at exterior window and door openings shall be installed in accordance with one or more of the <br />following: <br />5 1.1 The fenestration manufacturer's installation and flashing instructions, or for applications not addressed in the fenestration <br />manufacturer's instructions, in accordance with the flashing manufacturer's instructions Where flashing instructions or details are <br />not provided, pan flashing shall be installed at the sill of exterior window and door openings. Pan flashing shall be sealed or <br />sloped in such a manner as to direct water to the surface of the exterior wall finish or to the water resistive barrier for subsequent <br />drainage. Openings using pan flashing shall incorporate flashing or protection at the head and sides <br />1.2 1.2. In accordance with the flashing design or method of a registered design professional. <br />1.3 1.3. In accordance with other approved methods. <br />WPO SELF -ADHERED FLASHING 1.4 In accordance with FMAIAAMA 100, FMA/ AAMA 200, FMA/WDMA 250, FMA/AAMA/ WDMA 300 or FMA/AAMA/WDMA 400. <br />i LJ" � INSIDE CORNER � I- �J <br />2.2.At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under <br />stucco copings. <br />► Ground �► - 3.3.Under and at the ends of masonry, wood or rretal copings and sills. <br />y I 4. 4. Continuously above all projecting wood trim. <br />5.5.Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />tU <br />0 <br />U <br />> <br />y <br />QJ <br />CU <br />I <br />Q <br />0 <br />L_ <br />r�...Y <br />C lJ <br />-� <br />U <br />cn <br />CU <br />0 <br />O <br />� <br />O <br />O <br />L <br />U) <br />_O <br />r_ <br />Ffe n 3 4?3 <br />`1 pfa llirtual V <br />6. E At wall and roof intersections. <br />7.7.At built-in nutters for co ns Re y/ew c evi gss/str- <br />vv , ' f, t t L' n► I nip <br />_LF-ADHERED FLASHING �• <br />kTCH <br />It iFRF;:i FI ASH!Nk <br />�1 <br />F$ <br />r. <br />i <br />P®$ FOUNDATION WEEP SCREED <br />I-W OF �Af <br />. )rIAINAL�E PLANt WRb <br />I <br />-- BOND BREAK WRB <br />i <br />Si- LA 1 H <br />WRAP DP WRB ON IC' <br />THE VERTIC.Al <br />I <br />SURFACE TO FOP OF <br />`S FLANGEE, AS AN AIR <br />/ BARRIER <br />INCH FL.ANGF <br />- - <br />PLASTER STOP -- I ilti (!AP Iti A RESULT Of <br />r1A i !!f (AL SHRINKAGE. <br />DO NOT SEAL <br />CON I INUOUS bAt <br />ROD& SEALANT -- t fli :;(A0.1 .) PLAS I Il, <br />tA; <br />SOFFI r/CANTILEVER <br />W <br />a er asas .. <br />Lath <br />Sheathing <br />Stucco <br />LEGEND <br />--0 0 <br />UftAlNAlit PLANE (UP) WEATHER RESISTANT <br />BARRIER (WRB) <br />BOND BREAK WEATHER RESISTANT BAHRILR - <br />SELF FURRING (SF) LATH -- <br />Pt ASTER ACCESSORY . .. ___. <br />--STRUCTURAL FRAMIN( <br />tI I <br />'r ` STRUCTURALSHEATHIrJ,'. <br />,..•--STRIP OF SAF <br />URAINA6L PLANE WRB <br />( -.BOND P,RFAK WRB <br />-SF LATH <br />A;;TERsI,I' <br />ON1 INI InI IR RAC'KFR ROD <br />,f At ANT <br />EMEN II I`IOUS F 1NiSH <br />1WP10 <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL <br />FLASHING AND WATERPROOFING METHODS TO BE USED. <br />7/8" Cement Plaster <br />,ante With t eted and a <br />Y t7ebra gnne it �FgO jt <br />X?300 <br />//8" Cement Plaster <br />in accordance with <br />AS1 MC926 <br />Felt backed metal <br />lathe In accordance <br />with ASTMC 1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs <br />112" Cementitious <br />Decorative Finish <br />All inside and <br />outside cornet will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />-4 <br />Q3 <br />Q <br />o <br />0 <br />n <br />LJLJ <br />I <br />SHEET NO. <br />WP1.0 <br />