My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36813 Yesler Dr (2)
Zephyrhills
>
Building Department
>
Building Plans
>
36813 Yesler Dr (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 8:49:00 PM
Creation date
2/19/2025 8:48:19 AM
Metadata
Fields
Template:
Building Plans
Street #
36813
Location
Yesler Dr
Contractor
K Hovanian Co LLC
Building Plans - Permit #
3083
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SEE <br />SOFFIT AT RAKE (BEYOND) <br />ROOF PLAN <br />REFER TO PLANS <br />= <br />FINISH PER PLAN <br />- <br />7/8 STUCCO OVER LATH <br />_____=_ <br />W/ 60 MIN. GRADE D PAPER BACKED <br />LATH OVER BARRICADE PLUS WRB <br />(OR APPROVED EQUAL) <br />BENT METAL FLASHING <br />REFER TO "L" FLASHING DETAIL <br />2X LEDGER BOARD <br />TOP OF C.M.U. <br />(REFER TO ELEV.) <br />INSULATION AS <br />2X ALUM WRAPPED FASCIA <br />PER SPECS. <br />----- <br />BD. w/ALUM DRIP EDGE <br />PRE-ENGINEERED <br />SOFFIT INSTALLED PER <br />GABLE END ROOF <br />MANUF. SPECS <br />TRUSS - REFER TO <br />2X PT BLOCKING <br />STRUCTURALS <br />HURRICANE STRAP - REFER TO <br />STRUCTURALS <br />1/2" (MIN.) CLG. BD. <br />MASONRY LINTEL - REFER TO <br />STRUCTURALS <br />TYP. HIPPED PENT <br />ROOF DETAIL <br />SCALE: 1/2" = 1'-0" <br />1-STORY - MASONRY WALL <br />ROOF SHINGLES OVER <br />TWO LAYERS OF ASTM D226 TYPE II <br />OR <br />SYNTHETIC UNDERLAYMENT COMPLYING <br />WITH ASTM D226 TYPE II INSTALLED PER <br />t2 <br />R905.1.1.1 (SEE SHEET CS2) <br />12 <br />SEE ROOF <br />PRE-ENGINEERED ROOF <br />SEE ROOF <br />PLAN <br />TRUSSES AT TYP. 24" O.C. <br />PLAN <br />BOTTOM CHORD VARIES. REFER <br />TO TRUSS MFGR. DRAWINGS. <br />HURRICANE STRAP EACH END <br />OF TRUSS - REFER TO <br />�ononn. c) <br />STRUCTURAL. <br />TOP OF C.M.U. <br />(REFER TO ELEV.) <br />INSULATION PER <br />2x6 ALUM WRAPPED FASCIA <br />COMMUNITY SPEC. <br />EE BD. w/ALUM DRIP EDGE <br />SEE ENERGY CALCS. <br />1/2" (MIN.) CLG. BD. <br />1/2" (MIN.) <br />SOFFIT INSTALLED PER <br />CLG. BD. <br />1x PT DRAPE BLKG <br />MANUF. SPECS <br />(r TYPE'X' GYP. BD. <br />ABOVE WINDOWS 1/2" <br />2X PT BLOCKING <br />TO BE PROVIDED <br />G.W.B. <br />WHEN LIVING SPACE <br />SEE STRUCTURAL <br />IS ABOVE GARAGE) <br />WINDOW PER PLAN <br />PLAN <br />GYP.BD. <br />WINDOW SILL <br />1/2" GYP. BD. OVER RADIANT PRECAST WIN. SILL <br />BARRIER INSULATION (R-4.1) <br />ATTACHED TO ix2 PT. <br />FURRING @ 24" O.C. LOPE GRADE AWAY <br />BASE BOARD /ROM HOUSE <br />Y—" <br />FIN. FL. <br />FOUNDATION <br />PER STRUCTURAL DRAWINGS <br />TYP. 1—STORY WALL @ WINDOW <br />SCALE: 1/2" = 1'-0" <br />ATTIC OR <br />SECOND FLOOR <br />LIVING SPACE <br />REFER TO PLANS <br />PROVIDE 2X4— <br />FRAMED <br />ENCLOSURE FOR <br />ELECTRICAL <br />PANEL, FINISH W/ <br />1" GYPSUM <br />BOARD <br />ELECTRIC METER <br />LOCATION - SEE <br />PLANS. VERIFY <br />INSTALLATION IN <br />FIELD <br />STUCCO <br />FINISH <br />EXTERIOR <br />CMU BLOCK <br />WALL <br />NOTE: ELECTRICAL <br />PANEL IS TO BE <br />INSTALLED ACCORDING <br />TO ALL APPLICABLE <br />LOCAL, STATE AND <br />NATIONAL CODES. <br />VERIFY PANEL <br />DIMENSIONS PRIOR TO <br />CONSTRUCTION. <br />GRADE <br />GYPSUM <br />GYPSUM <br />BOARD <br />BOARD Z <br />3 1/2" a. <br />k GYPSL <br />w <br />GARAGE a - <br />BOARD <br />NICHE F( <br />ELECTRII <br />PANEL & <br />WIRING <br />M <br />ELECTRICAL <br />PANEL <br />ELECTRII <br />PANEL <br />N <br />`O <br />EXTERIO <br />co <br />Ir <br />CMU BLC <br />WALL <br />tt <br />CONCRETE "' CONCRE' <br />CURB REFER CURB RE <br />TO PLANS TO PLAN; <br />CONCRETE <br />SLAB ON <br />a i - GRADE AT <br />GARAGE <br />FLOOR <br />ROOF SHINGLES OVER <br />TWO LAYERS OF ASTM D226 TYPE II OR <br />SYNTHETIC UNDERLAYMENT COMPLYING <br />WITH ASTM D226 TYPE II INSTALLED PER <br />R905.1.1.1 (SEE SHEET CS2) <br />PRE-ENGINEERED ROOF <br />TRUSSES AT TYP. 24" O.C. <br />BOTTOM CHORD VARIES. REFER <br />TO TRUSS MFGR. DRAWINGS. <br />HURRICANE STRAP EACH END <br />OF TRUSS - REFER TO <br />STRUCTURAL. <br />OL TOP OF C.M.U. <br />(REFER TO ELEV.) <br />2x6 ALUM WRAPPED FASCIA <br />BD. w/ALUM DRIP EDGE <br />SOFFIT INSTALLED PER <br />MANUF. SPECS <br />2X PT BLOCKING <br />SEE STRUCTURAL <br />PLAN <br />8" CMU BLOCK <br />W/ CEMENTITIOUS <br />FINISH (BEYOND) <br />EXPANSION JOINT <br />GARAGE SLAB, 4„ SPECS DRIVEWAY PER COMMUNITY <br />SEE STRUCTURAL <br />PLANS h 0'-0" <br />SLOPE SSE FIN. FL. <br />•. <br />`—FOUNDATIONM I PER STRUCTURAL DRAWINGS <br />WALL SECTION @) GARAGE DOOR <br />SCALE: 1 /2" = 1'-O" <br />ATTIC OR SECOND <br />FLOOR LIVING SPACE <br />REFER • PLANS• <br />_- <br />' Post, <br />T„ar,x»7, <br />ELECTRICAL PANEL NICHE AT CMU BLOCK WALL <br />NOTE: THESE DETAILS DEPICT <br />ARCHITECTURAL SPECIFICATIONS AND <br />FINISHES ONLY. REFER TO STRUCTURAL <br />DRAWINGS FOR STRUCTURAL INFORMATION <br />fY <br />W <br />}2� <br />Z O � <br />O }. <br />W OcQO <br />�p <br />(AVWW <br />Q�W f- <br />cn W W <br />a cc cr_ <br />YOI-Z <br />�Ii00U) <br />ZZZ~Z <br />=gQm_3 <br />w a. = cr a <br />Jcna00 <br />= Z LL (n <br />�I-QZp <br />cz <br />a <br />n <br />ro Q <br />O <br />gH <br />2 <br />0 <br />V <br />O <br />J <br />0 <br />O <br />O0-0 <br />0-i <br />< <br />w <br />U U <br />w <br />�w <br />mmmm <br />IL <br />a(1) <br />U) <br />l< <br />w <br />w <br />X <br />U) <br />Z <br />0 <br />U <br />G <br />Ck <br />i <br />i <br />i <br />i <br />i <br />N <br />G <br />r, <br />No 77824 ' <br />STATE OF % i <br />Rc C R1V.' <br />CO UN1 <br />LINKS AT CALUSA <br />SPRINGS <br />PLAN # 6100 <br />RELEASED: 10/5/21 <br />SHEET i <br />A5•21 <br />
The URL can be used to link to this page
Your browser does not support the video tag.