2" PVC CONDUIT <br />2-2/0 COPPER <br />0 OR COPPER <br />OR <br />2-4/O ALUMINUM 150 AMP 4,, <br />IVIETER 1-3/0 ALUMINUM CIRCUIT <br />MAIN <br />CIRCUIT <br />#4 COPPER OR ALUM. BREAKER <br />1/2" PVC <br />CONCRETE ENCASED <br />GROUNDED ELECTRODE <br />T <br />II <br />ELECTRICAL RISER DIAGRAM <br />NOT TO SCALE <br />ELECTRICAL <br />METER (V.I.F.) <br />FIRST FLOOR ELECTRICAL PLAN <br />SCALE: 1 /4"=1'-0" <br />ELECTRICAL KEY <br />I DUPLEX CONVENIENCE OUTLET <br />WEATHERPROOF DUPLEX OUTLET <br />F GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />220 VOLT OUTLET <br />USB COMBO OUTLET <br />WALL SWITCH <br />9 THREE-WAY SWITCH <br />4 FOUR-WAY SWITCH <br />-¢- KEYLESS LIGHT FIXTURE <br />-�- CEILING MOUNTED LED LIGHT FIXTURE <br />�- WALL MOUNTED INCANDESCENT LIGHT FIXTURE <br />VAPOR PROOF LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN <br />FLUORESCENT LIGHT FIXTURE <br />f� EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />EI CHIMES (OPTIONAL) <br />E] PUSHBUTTON SWITCH (OPTIONAL) <br />@ COMBINATION SMOKE / CO2 DETECTOR <br />C) SMOKE DETECTOR <br />F< TELEPHONE (OPTIONAL) <br />[l TELEVISION (OPTIONAL) <br />01 ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />C) JUNCTION BOX <br />�-� STANDARD ELECTRICAL LINE <br />NOTES: <br />1. PROVIDE AND INSTALL GROUND FAULT <br />CIRCUIT-INTERUPTERS (GFI) AND ARC FAULT CIRCUIT <br />INTERRUPTERS (AFCI) PER 2017 NEC 210.12 <br />2. UNLESS OTHERWISE INDICATED, INSTALL SWITCHES & <br />RECEPTACLES AT THE FOLLOWING HEIGHTS ABOVE FINISH <br />FLOOR: <br />SWITCHES ........... 42" <br />OUTLETS.............14" <br />ABOVE COUNTER OUTLETS ...... 46" <br />TELEPHONE ......... 14" <br />TELEVISION .......... 14" <br />3. ALL SMOKE DETECTORS SHALL BE HARDWIRED INTO AN <br />ELECTRICAL POWER SOURCE AND SHALL BE EQUIPPED WITH <br />A MONITORED BATTERY BACKUP. PROVIDE AND INSTALL <br />LOCALLY CERTIFIED SMOKE DETECTORS. <br />4. OUTLET AND LIGHTING RECEPTACLES FOR ALL DWELLING <br />ROOMS, WITH THE EXCEPTION OF KITCHENS, BATHROOMS, <br />AND GARAGES, SHALL REQUIRE AFCI PROTECTION. <br />5. IT IS THE RESPONSIBILITY OF THE LICENSED <br />ELECTRICIAN TO INSURE THAT ALL ELECTRICAL WORK IS <br />IN FULL COMPLIANCE WITH 2O17 NFPA 70, FLORIDA <br />RESIDENTIAL CODE 2020, AND ALL APPLICABLE <br />LOCAL STANDARDS, CODES, AND ORDINANCES. <br />6. ALL RECEPTACLES SHALL BE TAMPER RESISTANT PER NEC <br />406.12. <br />7. CIRCUIT NUMBERS ARE FOR REFERENCE ONLY. <br />8. LUMINIAIRES IN CLOTHES CLOSETS SHALL BE INSTALLED <br />PER THE PROVISIONS OF 2017 NEC 410.16(A) & (B) <br />9. RECESSED LIGHTING TO BE AIR TIGHT AND IC RATED <br />10. A MIN OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED <br />FIXTURES SHALL BE HIGH -EFFICIENCY LAMPS <br />11. GFCI DEVICES SHALL BE READILY ACCESSIBLE <br />12. REFER TO ENERGY CALCULATIONS FOR ADDITIONAL <br />INFORMATION. <br />13. PROVIDE THE REQUIRED CLEARANCES AROUND <br />PANELS AND DISCONNECTS IN COMPLIANCE WITH <br />NEC 110,26. <br />14. THE BRANCH CIRCUIT SUPPLYING THE RECEPTACLE(S) IN <br />A GARAGE SHALL NOT SUPPLY OUTLETS OUTSIDE OF THE <br />GARAGE AND NOT LESS THAN ONE RECEPTACLE OUTLET <br />SHALL BE INSTALLED FOR EACH MOTOR VEHICLE SPACE <br />!Y <br />W <br />�O>_F_ <br />1- <br />>oCQO <br />W <br />cnUWw <br />Q�WI— <br />_ > J <br />Z) It <br />LL <br />z0®W <br />z <br />a- _ <br />U) 0 0 Q <br />� H Q z ❑ <br />Q <br />c <br />Q o <br />O <br />� a <br />Q <br />l� <br />V <br />0 <br />0 <br />°° <br />o a <br />w <br />00� <br />J <br />LL. U <br />0 <br />"- <br />0� <br />U) 1-0 <br />w <br />0� <br />u <br />rL <br />w <br />U) <br />j <br />uw <br />z <br />0 <br />IL <br />A <br />O_ <br />LLI <br />cw <br />O <br />i-- <br />COMMUNITY: <br />LINKS @ CALLISA SPRINGS <br />PLAN # 6101 <br />RELEASED: 10/6/21 <br />SHEET <br />Elel <br />