CONCRETE: <br />1, ALL C❑Nr_RETE SHALL BE NORMAL WEIGHT (145 PCF). USING <br />TYPE 1 PORTLAND CEMENT, HAVING A MINIMUM OF 28 DAY <br />COMPRESSIVE STRENGHT OF 3,000 PSI. <br />2. APPLICABLE CODES AND STANDARDS FOR CONCRETE SHALL BE <br />ACI PUBLICATI❑NS, 301-72, 318-77, 347-68, AND SP-5 <br />CONCRETE MIX SHALL BE ACCORDANCE WITH ACI 318-77 AND ACI <br />301-72. <br />3, REINFORCING STELL SHALL MEET ASTM A615. GRADE 40. <br />4, CONCRETE COVER FOR REINFORCING STEEL SHALL BE AS <br />FOLLOWS: <br />BEAMS ABOVE GRADE 1 J' <br />SLAB ON GROUND CENTERED <br />FOOTINGS 3'SIDES & 3' BOTTOM GRADE BEAMS 1 �' TOPS, 2' <br />SIDES 3' BOTTOMS <br />COLUMNS 1 J' <br />STRUCTURAL SLAB' <br />5. WELDED WIRE FABRIS REINFORCEMENT SHALL BE IN <br />ACCORDANCE WITH ASTM A185, <br />6, ALL REINFORCEMENT SHALL BE LAPPED A MINIMUM OF 36 BAR <br />DIAMETERS UNLESS ❑THERWISE NOTED ON THE STRUCTRAL <br />DRAWINGS, <br />7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL BRACING <br />AND SHORING AND THE DESIGN OF THE SAME DURING <br />CONSTRUCTION, <br />8,-CONSTRUCTI❑N JOINTS SHALL BE LOCATED AS PER THE <br />DRAWINGS. <br />9. ALL REINFORCEMENT SHALL BE HELD SECURELY IN P❑SITION <br />WITH STANDARD ACCESSORIES DURING PLACING OF CONCRETE. <br />10, SEE BUILDING, MECHANICAL, ELECTRICAL AND PLUMBING <br />DRAWINGS FOR THE EXACT LOCATION AND ARRANCEMENT OF ANY <br />PADS, SUPPORT FRAMS ETC, REQUIRED FOR MECHANICAL AND <br />ELECTRICAL EQUIPMENT AND NOT SHOWN ON THE STRUCTRIAL <br />DRAWINGS. GENERAL CONTRACTOR SHALL COORDINATE WITH <br />OTHER TRADES CONCERNING PLATES, ANCHORS, NOTCHES, ETC. <br />TO BE PLACED IN CONCRETE. <br />11. ANY CONFLICTS BETWEEN STRUCTRAL DRAWINGS AND/OR <br />SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE <br />ENGINEER PRI❑R TO PRECEEDING WITH THE WORK AFFECTED. <br />16' f <br />THRU CONTINUOUS <br />DOTER <br />4'/3000 PSI CONCRETE SLAB <br />W/ 6'x6' #10-10 WWM OVER <br />6 MIL POLYFILM W/EDGES LAPPED 6' <br />&TAPED, OVER CLEAN COMPACTED <br />TERMITE TREATED SOIL POURED SIMULTANEOUSLY <br />WITH FOOTERS W/2 #5 REBAR C❑NTINUOUS <br />AND WITH PIERS PER PLAN AND PIER DETAILS <br />WF-1 TYPICAL FOOTER DETAIL <br />FOOTING NOTES: <br />BOTTOM MAT] r <br />1 10, - <br />BOTTOM MA <br />4' - 0' <br />3/4" DIA <br />ASTMA-307 STEEL <br />BOLTS EMBEDDED <br />18" (MIN 2 1/2" <br />ANCHOR <br />INT❑ PIER <br />PR❑JECTI❑N) <br />#5 HAIRPIN <br />4'x 4' x 3' DP 3000 PSI <br />CONCRETE PIER <br />WITH TWO LAYERS OF #5 REBARS EACH <br />WAY ' EQ SPACED W/ 3" MIN CVR <br />3/4" DIA <br />ASTMA-307 STEEL ANCHOR <br />BOLTS EMBEDDED INT❑ PIER <br />18" (MIN 2 1/2" PR❑JECTI❑N) <br />44 <br />----------- ---------------- <br />x 4` x 2' DP 3000 PSI <br />C❑NCRETE PIER <br />---- - J WITH TWO LAYERS ❑F #5 REBARS EACH <br />WAY EQ SPACED W/ 3" MIN CVR <br />4'-0' <br />r.���ffd2[�Wlllvr0=1»� <br />3/4" DIA <br />ASTMA-307 STEEL ANCHOR <br />BOLTS EMBEDDED INT❑ PIER <br />18" (MIN 2 1/2" PR❑JECTI❑N) <br />44 <br />---------------------------------- <br />3 x3 x2 DP 3000 PSI <br />Cu ° I -----CONCRETE PIER <br />---- - WITH TWO LAYERS OF #5 REBARS EACH <br />WAY EQ SPACED W/ 3" MIN CVR <br />3' - 0' <br />CP-3 TYPICAL EDDTER <br />MARK <br />FOOTING SIZE <br />REINFORCEMENT <br />REMARKS <br />CF-1 <br />4'-0" X 4'-0" X 3' <br />#-5 @ 6" O.C. <br />#5 HAIR PINS PER PLAN <br />CF-2 <br />4'-0" X 4'-0" X 2' <br />#-5 @ 6" O.C. <br />CF-3 <br />S-O" X 3'-0" X 2' <br />#-5 @ 6" O.C. <br />WF-1 <br />12" W X 16" H <br />2 - #5 CONT. <br />NOTES: ALL TH'D W/NUT <br />& 1/4" X3"X3" <br />ALL ANCHOR BOLTS TO BE LOCATED AS SPECIFIED ON SHEET F1 ANCHOR BOLT PLAN SQ WASHERS <br />ALL ANCHOR BOLTS TO BE 3/4" X 15" EMBEDMENT MINIMUM <br />BASE ANGLE TO BE FASTENED @ 24" O.C. W/ DRIVE PINS <br />DETA1�-g ' <br />F , I ,HER4ERYI �E:F7IFY THAT I HAVE <br />~`REViEWEb Tl}I . AN AND FIND IT TO <br />❑ L`I0CE WITH THE <br />1. THE MINIMUM SOIL BEARING CAPACITY REQUIRED TO SUPPORT THIS <br />STRUCTURE IS 1,000 PSF. <br />2. A PERMANENT SIGN WITH IDENTIFIES THE TERMITE TREATMENT PROVIDER <br />AND NEED FOR RE -INS AND TREATMENT CONTRACT RENEWAL SHALL BE <br />PROVIDED. THE SIGN SHALL BE POSTED NEAR THE WATER HEATER OR <br />ELECTRIC PANEL FBC 104.26 <br />3. TO PROVIDE FOR INSPECTION FOR TERMITE INFESTATION, BETWEEN WALL <br />'COVERING AND FINAL EARTH GRADE SHALL NOT BE LESS THAN 6 INCHES <br />EXCEPTION PAINT OR DECORATIVE CEMENTATION FINISH LESS THAN 8" THICK <br />ADHERED DIRECTLY TO THE FOUNDATION WALL. <br />4. INITIAL TREATMEANT SHALL BE DONE AFTER ALL EXCAVATION AND BACK <br />FILL IS COMPLETED. <br />5. SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RETREATED <br />INCLUDING SPACES BOXED OF FORMED. <br />6. BOXED AREAS IN CONCRETE FLOORS AND FOR SUBSEQUENT INSTALLATION <br />OF TRAPS, ETC. SHALL BE MADE IN PERMANENT METAL OR PLASTIC FORMS. <br />PERMANENT FORMS MUST BE OF A SIZE & DEPTH THAT WILL ELIMINATE THE <br />DISTRUBANCE OF SOIL AFTER THE TREATMENT. <br />7. MINIMUM 6 MIL POLYFILM MUST BE INSTALLED TO PROTECT AGAINST <br />RAINFALL DILUTION IF RAINFALL OCCURS BEFORE POLYFILM PLACEMENT. <br />RETREATMENT IS REQUIRED. <br />8. CONCRETE OVERPOUR AND MORTOR ALONG THE FOUNDATION PERIMETER <br />MUST BE REMOVED BEFORE EXTERIOR SOIL TREATMENT. <br />9. AN EXTERIOR VERTICAL CHEMICAL BARRIER MUST BE INSTALLED AFTER <br />CONSTRUCTION IS COMPLETE INCLUDING LANDSCAPING AND IRRIGATION ANY <br />SOIL DISTRUBED AFTER THE VERTICAL BARRIER IS APPLIED SHALL BE <br />RETREATED. <br />10. ALL BUILDINGS ARE REQUIRED TO HAVE PRE -CONSTRUCTION TREATMENT. <br />11. A CERTIFICATE OF COMPLIANCE MUST BE ISSUED TO THE BUILDING <br />DEPARTMENT BY LICENSED PEST CONTROL COMPANY BEFORE A CERTIFICATE <br />OF OCCUPANCY WILL BE ISSUED. THE CERTIFICATE OF COMPLIANCE SHALL <br />STATE THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE <br />PREVENTION OF SUBTERRANEAN TERMITES AND THAT THE TREATMENT IS IN <br />ACCORDANCE WITH THE RULES AND LAW OF THE FLORIDA DEPARTMENT OF <br />AGRICULTURE AND CONSUMER SERVICE. <br />12. AFTER ALL WORK IS COMPLETED LOOSE WOOD AND FILL MUST ME <br />REMOVED FROM BELOW AND WITHIN ONE FOOT OF THE BUILDING. THIS <br />INCLUDES ALL GRADE STAKES, TUB TRAP BOXES, FORMS, OR OTHER CELLULOSE <br />CONTAINING MATERIAL. <br />13. NO WOOD, VEGETATION STUMP, CARDBOARD, TRASH, ETC. SHALL BE <br />BURIED WITHIN 15 FEET OF ANY BUILDING OR PROPOSED BUILDING. <br />FLO YV 3CrILD:N DDE 017 6TH EDITI❑N <br />PAATE F <br />r� <br />DAVID W, SMITH,M.S., P,E.#53608 <br />D.. .SM-1TH,M.S.9P.E <br />FLORIDA PROFESSIONAL ENGINEER LICENSE NUMBER 53608 <br />Consulting Projects Engineer <br />9909_WALLAST❑N DRIVE-DADE CITY, FLORIDA 33525 <br />PHONE/TEXT:813-469-2289 E-MAIL: dwsflpe@earthllnk,net <br />PROJECT STORAGE BUILDING <br />M <br />PROJECT PARK PLACE LOT 113 B CORREIA DR. <br />ADDRESS ZEPHYRHILLS, FL 33542 <br />FOUNDATION PLAN <br />DESIGN: DWS I DRAFT: DWS I CK: DWSFLPE <br />DATE:6/15/2020 I SHEET F2 OF <br />